1U Fan Unit Table of contents Warning ………………………………2 Safety Instructions …………………………… 2 Operating Determinations ……………………….4 Connection with the mains……………………….4 Return Procedure …………………………..5 Claims ………………………………5 Description of the device …………………………6 Frontside…………………………….6 Backside …………………………….6 Installation ……………………………..
-
Page 3: Warning
Save the carton and all packing materials. In the event that a device must be returned to the factory, it is important that the device is returned in the original factory box and packing. Your shipment includes: ● DAP Audio 1U Fan Unit ● IEC powercable 1,5m ●…
-
Page 4
1U Fan Unit IMPORTANT: The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorized modification to the system. ● Always let the device cool down before cleaning or servicing. ●… -
Page 5: Operating Determinations
1U Fan Unit Operating Determinations This system is not designed for permanent operation. Consistent operation breaks will ensure that the system will serve you for a long time without defects. If this system is operated in any other way, than the one described in this manual, the product may suffer damages and the warranty becomes void.
-
Page 6: Return Procedure
1U Fan Unit Return Procedure Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility.
-
Page 7: Description Of The Device
1U Fan Unit Description of the device Features The DAP 1U Fan Unit is used for controlling temperature of your rack. The device has four built-in fans which can be switched on and off by the programmable temperature settings. ●…
-
Page 8: Installation
1U Fan Unit Installation Remove all packing materials from the DAP 1U Fan Unit. Check if all foam and plastic padding is removed. Secure the equipment into a 19″ rack if preferred. Connect all cables. Do not supply power before the whole system is set up and connected properly.
-
Page 9: Set The Temperature Limit
1U Fan Unit Increase button Press the button to increase the temperature limit, check the maximum temperature or scroll through the menu with the increase button. R button Press the button to check the exceeding temperature. Decrease button Press the button to decrease the temperature limit, check the minimum temperature or scroll through the menu with the decrease button.
-
Page 10: Warnings
Note: Press any key to shut down the alarm buzzer, the settings and display status will not change. Maintenance The DAP Audio 1U Fan Unit requires almost no maintenance. However, you should keep the unit clean. Disconnect the mains power supply, and then wipe the cover with a damp cloth. Do not immerse in liquid.
-
Page 11: Product Specifications
1U Fan Unit Product Specifications Model: DAP Audio 1U Fan Unit Power supply: 230V AC (±10%), 50/60 Hz Power connection: IEC power connector Rated power consumption: Dimensions: 483 x 290 x 44 mm (LxWxH) 19” x 1HE (LxH) Weight: 4,8 kg Inputs &…
-
Page 12
©2018 DAP Audio…
Актуально на 18.05.2023г.
Предназначен для дополнительного охлаждения активного серверного оборудования.
Доставка
Оплата
Наши услуги
- Описание
- Отзывы (0)
Устанавливается в телекоммутационный шкаф с посадочным местом на 1U. Предназначен для охлаждения активного оборудования.
Характеристики:
- Количество вентиляторов — 4 шт
- Напряжение питания — 220-240В
- Ток потребляемый одним вентилятором — 0.14А
- Скорость вращения — 2700 об/мин
- Покрытие — порошково-полимерное
- Цвет — черный
- Размер — 480 х 350 х 45 мм
Возможный аналог других производителей:
Cabeus JG03-BK, ZPAS WZ-5606-35-01-011, ZPAS WZ-5606-35-01-011-CW, ZPAS WZ-PW34-00-00-011
Вы смотрели
181
ACCESSORIES
wall mounting
PROline
EUROline
ECOline
SOHOline
SOHO Slimline
Part Number
Product Definition
WxDxH
(mm)
M11 HV1F W T
Cooling unit with 1 fan
+ thermostat controlled,
suitable for wall mounting
cabinets
350x190x44
X
X
X
X
X
X
X
X
X
M11 HV2F W T
Cooling unit with 2 fan
+ thermostat controlled,
suitable for wall mounting
cabinets
350x190x44
X
X
X
X
X
X
X
X
X
E44 HV2F T
19″ 1U rack mount
cooling unit with 2 fans +
thermostat controlled
483x150x44
X
X
X
X
X
X
X
X
X
E44 HV4F T
19″ 1U rack mount
cooling unit with 4 fans +
thermostat controlled
483x300x44
X
X
X
X
X
X
X
X
X
W=600 mm D=450 mm
W=600 mm D=560 mm
W=600 mm D=450+160 mm
W=600 mm D=450 mm
W=600 mm D=600 mm
W=600 mm D=450 mm
W=600 mm D=600 mm
W=292 mm D=300 mm 10»
W=520 mm D=300 mm 19»
W=520 mm D=400 mm 19»
W=475 mm D=500 mm H=140 mm 19”
Air Removals / Cooling Units — Thermostat controlled
COMPATIBILITY
Thermostat-air temperature controller Range: 0-35
degree, below set point fans does not activated
Above set point fan units start ventilation.
Complete with inner wiring.
Noise: 47 db ( lower noise is optional)
A fan provides 2,33 / min. Air removal, CFM: 80
Colour: RAL 7035 light grey or RAL 9005 black
PROline
EUROline
ECOline
SOHOline
SOHO Slimline
Part Number
Product Definition
WxDxH (mm)
M11 HV1F W DT
Cooling unit with 1 fan
+ DIGITAL thermostat
controlled, suitable for wall
mounting cabinets
350x190x44
+1U 19”
X
X
X
X
X
X
X
X
X
M11 HV2F W DT
Cooling unit with 2 fan
+ DIGITAL thermostat
controlled, suitable for wall
mounting cabinets
350X190x44
+1U 19”
X
X
X
X
X
X
X
X
X
E44 HV2F DT
19″ 1U rack mount cooling
unit with 2 fans + DIGITAL
thermostat controlled
483x150x44
+1U 19»
X
X
X
X
X
X
X
X
X
E44 HV4F DT
19″ 1U rack mount cooling
unit with 4 fans + DIGITAL
thermostat controlled
483x300x44
+1U 19»
X
X
X
X
X
X
X
X
X
W=600 mm D=450 mm
W=600 mm D=560 mm
W=600 mm D=450+160 mm
W=600 mm D=450 mm
W=600 mm D=600 mm
W=600 mm D=450 mm
W=600 mm D=600 mm
W=292 mm D=300 mm 10”
W=520 mm D=300 mm 19”
W=520 mm D=400 mm 19”
W=475 mm D=500 mm H=140 mm 19”
Air Removals / Cooling Units — Digital Thermostat controlled
COMPATIBILITY
Digital thermostat control unit: 1U, 19’’, possible to
mount any location in the cabinet as rack mount
Range 0-35 degree, below set point, fans does not
activated. Above set point fan unit start ventilation.
Complete with inner wiring.
Noise: 47 db ( lower noise is optional)
A fan provides 2,33 / min. Air removal, CFM:80
Colour: RAL 7035 light grey or RAL 9005 black
WALL MOUNTING
IEK ITK 19″ Вентиляторный модуль 1U 4 вентилятора с цифровым термостат
Ищете Розетки и выключатели недорого? Обратите внимание на товар «IEK ITK 19″ Вентиляторный модуль 1U 4 вентилятора с цифровым термостат».
В интернет-магазине Амперкин ру вы можете купить данную позицию с артикулом FM05-1U4TS по цене 14311.79 ₽/шт. Добавьте товар в корзину и оформите заказ прямо сейчас!
19″ вентиляторные модули предназначены для установки и использования в любых шкафах ITK и служат для организации принудительного охлаждения и вентиляции установленного в них активного оборудования.
Модули устанавливаются на 19″ монтажные профили над оборудованием, требующим локального охлаждения в конкретном месте шкафа, занимая при этом 1U высоты шкафа.
Обратиться за консультацией можно по телефону:
или отправив письменное сообщение на e-mail:
19-дюймовые вентиляторные модули предназначены для установки и использования в любых шкафах ITK и служат для организации принудительного охлаждения и вентиляции установленного в них активного оборудования.
Вентиляторные модули имеют два или четыре вентилятора, заключенных в единый металлический корпус черного цвета высотой 1U, комплектуются выключателем со светоиндикацией и цифровым термостатом с дисплеем. Диапазон регулировки температуры термостата: от 0 до 60°С. Номинальное рабочее напряжение: 230В. Частота тока: 50Гц. Минимальный срок службы: 50 тыс. часов. Подача рабочего напряжения на вентиляторный модуль осуществляется через встроенный кабель электропитания длиной 2 метра и вилкой немецкого стандарта (евровилка).
Модули устанавливаются на 19″ монтажные профили над оборудованием, требующим локального охлаждения в конкретном месте шкафа, занимая при этом 1U высоты шкафа.