- Manuals
- Brands
- TSI Incorporated Manuals
- Measuring Instruments
- DUSTTRAK DRX 8533
Manuals and User Guides for TSI Incorporated DUSTTRAK DRX 8533. We have 1 TSI Incorporated DUSTTRAK DRX 8533 manual available for free PDF download: Operation And Service Manual
Detail Specifications: 981/981713-dusttrak_drx_8533.pdf file (18 Jan 2023) |
Accompanying Data:
TSI Incorporated DUSTTRAK DRX 8533 Measuring Instruments PDF Operation And Service Manual (Updated: Wednesday 18th of January 2023 12:16:06 AM)
Rating: 4.7 (rated by 33 users)
Compatible devices: VelociCalc Plus 8384, AIRPRO AP500, 8710 DP-CALC, 8587A, CA-CALC, VELOCICALC 9525, Alnor CompuFlow 8570, 4040.
Recommended Documentation:
Text Version of Operation And Service Manual
(Ocr-Read Summary of Contents, UPD: 18 January 2023)
-
1, DUSTTRAK™ DRX AEROSOL MONITOR MODEL 8533/8534/8533EP OPERATION AND SERVICE MANUAL P/N 6001898, REVISION L DECEMBER 2014 DustTrak DRX 8533 Desktop and 8534 Handheld DustTrak DRX 8533EP Monitor
… -
36, TSI Incorporated DUSTTRAK DRX 8533 Chapter 3 26 Name User can rename calibration to a description name. Photometric Changes the factory calibration of particle signal, based on Arizona Road Dust, to actual aerosol being measured. See below for sets to set this calibration. Size Corr Changes the factory calibration of the particle distribution, based on Arizona Road Dust, to actual …
-
19, Unpacking and Parts Identification 9 Parts Identification for the DustTrak DRX Handheld Aerosol Monitor Model 8534 Figure 1-3: Features on Handheld Model On/Off Inlet Stylus Touchscreen Port Cover Power USB Device USB Host Filter Access Battery Access (Screw Lockdown)
… -
26, Chapter 2 16 TrakPro software contains a comprehensive installation guide. TSI recommends printing out this guide prior to starting the TrakPro software installation on your computer, so it may be consulted during the installation. The TrakPro Software manual is located in the “Help” file in TrakPro software. There is no separately printed TrakPro Data Analysis so…
-
34, TSI Incorporated DUSTTRAK DRX 8533 Chapter 3 24 Flow Cal Run Flow Cal to change the flow set point. The flow set point is factory set to 3 L/min total flow. 2 L/min of the total flow is measured aerosol flow. 1 L/min of total flow is split off, filtered, and used for sheath flow. There is an internal P flowmeter in the DustTrak DRX instrument that controls flow rate to ±5% if factory setpoint.…
-
47, TSI Incorporated DUSTTRAK DRX 8533 Operation 37 Language Switches between display languages. After changing the display language, reboot the instrument. Run Mode The RunMode tab brings up sampling mode options. Sampling mode options include Survey Mode, Manual Log, and Log Mode 1-5. Survey Survey Mode runs a real time, continuous active sample, but does not log data. Manual Manual…
-
56, Chapter 3 46 Data Label Pressing the data label will toggle between PM 1 , PM 2.5 , Resp, PM 10 and Total size segregated mass fractions. Data Region Pressing the data region will bring up a dialog to show TWA or Average lines. TWA: Will show a secondary line on the graph showing the time weighted average of the data. This line will not show…
-
63, Maintenance 53 c. Pull out single cylindrical filter from filter well. If filter well is visibly dirty, blow out with compressed air. Figure 4-6: Pull out Single Cylindrical Filter from Filter Well (Desktop Model) d. Put a new filer (P/N 801673) back into filter well and screw filter cap back into place. e. Open blue retention clip by pinching ends inward and pushin…
-
65, Maintenance 55 Notes Replacement filters (HEPA and 3-mm Filter Cassette with mesh filter) were shipped with the new instrument. Order additional filters from TSI under PN 801673. TSI does not supply any filter media for the filter cassette. Any commercially available 37-mm filter media may be used with the DustTrak II or DRX desktop instruments to collect gravimetric refer…
-
74, TSI Incorporated DUSTTRAK DRX 8533 Appendix A 64 Battery 8533: Up to 2 Removable Li-Ion External and Internal charging Life, 1 battery: >6.5 hours (9 hours typical for a new battery) for both internal and external pump Desktop DustTrak monitors Life, 2 battery: >13 hours 8534: 1 Removable Li-Ion External and Internal charging Life: 6 hours typical Analog out 8533 U…
-
45, Operation 35 Analog setup screen sets the parameters that will drive the analog out port. Applies to the 8533 Desktop model only. Analog out [On, Off] Turns analog out port on. Size Fraction Selects the size channel that will drive the analog out. Output Setting [V, mA] Select between 0 to 5 V and 4 to 20 mA. Lower Limit [mg/m 3 ] Mass …
Recommended Instructions:
T700SVD, Edge 540, VITODENS 200 WB2B, FLH20-0-BX
-
English Page 1 ® Instruction Sheet 85RF INTRODUCTION The 85RF High Frequency Probe is designed to convert a dc voltmeter into a high frequency (100 kHz to 500 MHz) ac voltmeter. Conversion from ac to dc is accomplished on a one-to-one basis and includes a range of 0.25 to 30V rms. The probe’s dc output is calibrated to be equivalent to the rms value of a s …
85RF 4
-
100%recyclingPaper.Bleachedwithoutchlorine.100%papierrecycleBlanchisanschlore.100 %Recycling-Papier.Chlorfreigebleicht.100 %[email protected] ImprintThese operating instructions are published by Conrad Electronic GmbH, Klaus-Conrad-Str. 1, 92240 Hirschau/GermanyNo reproduction (including translation) is permitted in whole or part e.g. pho …
EKM 265 26
-
—ABB MEASUREMENT & ANALYTICS | OPERATING INSTRUCTION | OI/ATS410-EN REV. A4690 SeriesTurbidity sensorAccurate, reliable turbiditymeasurementMeasurement made easyIntroductionThe 4690 sensor is a rugged, reliable instrument designed to measure the turbidity content of water. The sensor also has additional features including dry standard verification and auto …
4690 20
-
ZRM 6010Quick Start Guide & Product CertificatesKurzanleitung & Produktzertifikate Guide de Prise en Main & Certificats du produit Guida Breve & Certificati di prodotto Guía de Inicio Rápido & Certificados del productoGuia de Início Rápido & Certificados do produto Краткое руководство & Сертификаты продуктаクイックスタ� …
Zehntner ZRM 6010 20
Additional Information:
Popular Right Now:
Operating Impressions, Questions and Answers:
DustTrak 8533/8530 — Анализатор пыли с поверкой
Анализаторы пыли DustTrak 8533/8530 предназначены для измерения массовой концентрации аэрозольных частиц в атмосферном воздухе и воздухе рабочей зоны.
Анализатор пыли DustTrak 8530 оснащен сменными импакторами и циклоном для фракционного разделения взвешенных аэрозольных частиц, позволяющими производить измерения в стандартах РМ10, РМ4, РМ2,5, РМ1. Анализатор 8533 позволяет измерять все указанные фракции (РМ10, РМ4, РМ2,5, РМ1), а также содержание общей пыли одновременно, и не нуждается в смене насадок за счет оригинальных технических решений, позволивших воплотить в одном приборе оптический счетчик и нефелометр.
Комплект поставки анализатора DustTrak 8533/8530:
- анализатор пыли DustTrak — 1 шт;
- циклон РМ4.0 — 1 шт. (для анализатора пыли DustTrak 8530);
- набор импакторов РМ1.0, РМ2.5, РМ10 — 1 компл. (для анализатора пыли DustTrak 8530);
- набор фильтров — 1 шт;
- набор принадлежностей — 1 шт;
- зарядное устройство — 1 шт;
- аккумуляторная батарея — 1 шт;
- адаптер АС — 1 шт;
- кабель USB — 1 шт;
- кейс — 1 шт;
- руководство по эксплуатации — 1 экз;
- паспорт — 1 экз;
- методика поверки — 1 шт.
Технические характеристики анализатора пыли DustTrak 8533/8530:
Диапазон размеров регистрируемых частиц | 0,1-15 мкм |
Диапазон измерения массовой концентрации аэрозоля | 0,1–150 мг/м3 |
Диапазон показаний, мг/м3 | 0,001-150 мг/м3 |
Пределы допускаемой основной относительной погрешности измерений | ±20% |
Номинальный объемный расход пробы | 3 дм3/мин |
Габаритные размеры | (224 ⨯ 216 ⨯ 135) мм |
Масса | 1,6 кг (без батареи) 2,0 кг (с одной батареей) |
Электрическое питание | 12 В 220В, 50 Гц |
Средний срок службы | 6 лет |
Средняя наработка на отказ | 6000 часов |
Условия эксплуатации
Температура | +5…+50°C |
Давление | от 84 до 106,7 кПа |
Влажность | от 5 до 95% |