BERcut-SDH
-
2
1.
……………………………………………………………………………………………………….42.
………………………………………………………………………………………53.
…………………………………………………………………………..64.
………………………………………………………………………………………..74.1.
………………………………………………………………………………..74.2.
………………………………………………………………………………………………74.3.
………………………………………………………………….84.4.
…………………………………………………………………………………………………..85.
…………………………………………………………………………………..105.1.
…………………………………………10
5.1.1………………………………………………………………………………………………..105.2.
RJ48
…………………………………………………………………………………….105.3.
BNC……………………………………………………………………………………..105.4.
SFP…………………………………………………………………..105.5.
SMA……………………………………………………………………………………..115.6.
LED……………………………………………………………………………………………………….116.
…………………………………………………………………………………………….137.
…………………………………………………………………………………………………….147.1.
………………………………………………………………………………………147.2.
PDH……………………………………………………………………167.2.1. TX Set >
Hierarchy…………………………………………………………………………….167.2.2.
TX Set >
Interface……………………………………………………………………………..167.2.3.
TX Set >
Payload………………………………………………………………………………177.2.4.
TX Set > Pattern
……………………………………………………………………………….197.3. PDH
……………………………………………………………………………………….217.3.1.
RX Set > Hierarchy
……………………………………………………………………………217.3.2.
RX Set >
Interface……………………………………………………………………………..217.3.3.
RX Set >
Payload………………………………………………………………………………227.3.4.
RX Set >
Pattern……………………………………………………………………………….237.4.
SDH……………………………………………………………………247.4.1.
TX Set >
Hierarchy…………………………………………………………………………….247.4.2.
TX Set >
Interface……………………………………………………………………………..257.4.3.
TX Set > Structure
…………………………………………………………………………….267.4.4.
TX Set >
Payload………………………………………………………………………………277.4.5.
TX Set > Pattern
……………………………………………………………………………….287.5.
SDH………………………………………………………………………297.5.1.
RX Set > Hierarchy
……………………………………………………………………………297.5.2.
RX Set >
Interface……………………………………………………………………………..307.5.3.
RX Set >
Structure…………………………………………………………………………….327.5.4.
RX Set >
Payload………………………………………………………………………………327.5.5.
RX Set >
Pattern……………………………………………………………………………….327.6.
……………………………………………………………………….337.6.1.
…………………………………………………………………………..337.6.2.
…………………………………………………………………………347.6.3.
…………………………………………………………………………….367.6.4.
…………………………………………………………………….378.
…………………………………………………………………………………………………..388.1.
PDH
…………………………………………………………………………………….388.1.1. Results >
Summary……………………………………………………………………………388.1.2.
Results > Error/Alarm ( 1)
……………………………………………………..398.1.3.
Results > Event
Log…………………………………………………………………………..418.1.4.
Results >
Signal………………………………………………………………………………..428.1.5.
Results >
Analysis……………………………………………………………………………..438.1.6.
Results >
Histograms…………………………………………………………………………43 -
38.1.7. Results > Bar
……………………………………………………………………………………468.2.
SDH
…………………………………………………………………………………….478.2.1. Results >
Summary……………………………………………………………………………478.2.2.
Results > Errors/Alarms (
1)…………………………………………………..478.2.3.
Results > Event
Log…………………………………………………………………………..538.2.4.
Results > Signal ( 1)
…………………………………………………………….548.2.5.
Results > Histogram ( 1)
……………………………………………………….558.2.6.
Results > Graph Bar
……………………………………………………………………608.2.7.
…………………………………………………………………………619.
/………………………………………………………………………………….689.1.
……………………………………………………………………..689.2.
………………………………………………………………………………………6910.
SDH………………………………………………………………………………………………..7210.1.
SDH Functions > Overhead Analyzer
………………………………………………………..73
10.1.20…………………………………………………………………………………………….9010.2.
SDH Functions > Overhead
Generator………………………………………………………9110.3.
SDH Functions > Pointer
Tasks………………………………………………………………..9310.4.
SDH Functions > Trace
Identifier………………………………………………………………96
10.4.3………………………………………………………………………………………………9810.5.
SDH Functions > Payload Labels
……………………………………………………………..98
10.5.3………………………………………………………………………………………………9910.6.
SDH Functions > Overhead BERT
………………………………………………………….10010.7.
SDH Functions > APS est
……………………………………………………………………100
10.7.3…………………………………………………………………………………………….10210.8.
SDH Functions > Tandem Connection Monitoring (TCM) ….10210.9.
SDH Functions > Tributary Scan
…………………………………………………………….102
11.
1………………………………………………………………………………………………10411.1.
PDH Functions > E1 / E3 Pulse Mask
……………………………………………………..104
11.1.1…………………………………………………………………………………………….10511.3.
PDH Functions > E1 APS est ( )
……………………………………..10511.4. PDH Functions
> E1 Frame
Words………………………………………………………….10511.4.1
………………………………………………………………………………………………..10612.
…………………………………………………………………………………………………..10713.
…………………………………………………………………………………………10813.1.
……………………………………………………………………………….10813.2.
…………………………………………………………………………………………..108
13.2.1…………………………………………………………………………………………….10813.3.
………………………………………………………………………………………………..10813.4.
……………………………………………………………………………………………..10913.5.
…………………………………………………………………………………………..10913.6.
……………………………………………………………………………………………10914.
………………………………………………………..11015.
…………………………………………………………………………………………..112…………………………………………………………………………..112
……………………………………………………………………………………………..112
…………………………………………………………………………………………..112
……………………………………………………………………………..113
……………………………………………………………………………………..113SDH
…………………………………………………………………………………………………………..113 -
41. ,
, , — . — , — BERcut-SDH, — , , , .
, , , . — . . — web-, — .
(c) Copyright 2006-2009 METROTEK. .
-
52.
BERcut-SDH. , —
. , — , — , PDH SDH. — web- METROTEKwww.metrotek.ru.
— , email . -. , , — .
:: + 8 495 961 00 71Email: [email protected]:
www.metrotek.ru -
63.
. , — , , , -. , . METROTEK — , — .
BERcut-SDH —
, , — . :
1. — .
2. SFP , . — SFP, , — 1- , , .
3. — , .
. —
, — .
-
74. 4.1.
PDH/SDH. , , . , . -, , . — , ( ). , , .
-. , . , 10 , .
4.2. :
4.2.1 Home. —
. Print.
. USB .
-
8 , , METROTEK.
Store. — . , . — — . , , -, .
History. — (LED) . LED, , LED.
Help. , -.
Arrow. — (, , , ). — Enter Escape.
Enter. . , .
Escape. — . — .
4.3. (LCD) —
. — , , . — , , .. , — . LCD , — , . -. -. , :
, ;
, , ., ;
. .
4.4. — —
, .
-
9 , — . — , . , — . , , . .
-
10
5. , —
: 10/100 T, USB 2.0 — USB 2.0. — .
. -, , METROTEK.
5.1. BERcut-SDH —
.
5.1.15.2. RJ48
— TX RX E1 T1 -. 120 E1 100 T1.
5.3. BNC- 75- TX RX E1, E3, DS3, E4
STM-1E .5.4. SFP
— (TX/RX), — (MSA). — SFP -. . SFP LC .
-
11
, ( — UPC) , . — SFP, , -, , SDH . , SFP — . ROHS — , — SFP
.5.5. SMA- NRZ 2,048
/ 2,048 . 1,544 / 1,544 TX, T1 .
5.6. LED BERcut-SDH
(LED) LED .
5.6.1LED Power . LED ,
. LED , — . LED , — . — , — . — . — 6-7 , , -.
LED Signal , — PDH SDH . LED , — . LED , PDH SDH .
LED Frame , PDH SDH — . LED -, , , .
LED Pattern , -. LED , , , .
-
12
LED ALM/ERR . LED , — . LED , , -. . — LED , , -/, — (O ->
O). -
13
6.
6.1 —
Home . ,
. , —
BERcut-SDH, LAN .
— , . , , — .
-
14
7. —
. — .
7.1 —
PDH, SDH T-. , .
7.1.
-. TX RX , — , — . , — . , . , LED , .
— TX RX, -. TX RX .
, — .
TX RX -, -. , TX — (PRBS)
-
15
223-1 VC-12, STM-4, RX PRBS 223-1 PDH 2M/.
HIERARCHY PDH SDH , , .
INTERFACE — . SDH, SDH (STM-1) PDH . — .
STRUCTURE SDH — .
PAYLOAD SDH PDH ( -) .
PATTERN SDH PDH -. — (PRBS), -T, 24- . .
,
. , .
7.1.1
-
16
7.2. PDH7.2.1. TX Set > Hierarchy
Hierarchy, TX. , , 2M E1. .
7.2.1.1NETWORK TYPE: PDH .HIGH RATE: 2, 34 45 /.
7.2.2. TX Set > Interface Interface, —
TX, .
7.2..2.1
-
17
ES PORT: PDH .
LINE CODE:- E1 HDB3
AMI. E1 HDB3, AMI .
— E3 HDB3.- E4 CMI.- DS1 B3ZS
AMI.- DS3 B3ZS.CLOCK SOURCE: :- Internal clock:
. 3.5 , G.812.
— External clock: 2/ 2 , SMA.
— From RX: -, .
— Offset: , Internal. , 25,000 .
BALANCED: RJ45. — 120. , , — 75- BNC TX.
7.2.3. TX Set > Payload Payload, —
TX.
-
18
7.2.3.1RATE: 2M 2M N x 64, :- 2M:
2,048 /;- N x 64:
N M 64 / ( ).
E3 (34 /) 34M. E4 (140 /) 140M. DS1 (1.544 /) 1.544M. DS3 (45 /)
45M.FRAMING: E1 , PCM31,PCM31C, PCM30 PCM30C. — G.704 G.706 :
— : (FAS) (MFAS);
— PCM31: (FAS) ;- PCM31C: (FAS)
CRC-4 ;- PCM30: (FAS)
(MFAS)- PCM30C: (FAS)
(FAS) CRC-4 .
E3 G.751 (PCM480).
-
19
E4 G.751 (PCM1920).
DS1 , D4 (SF) ANSI T1.107 (ESF).
DS3 , M13 C-Parity. Nx64, :
7.2.3.2FRAMING: PCM31, PCM31C, PCM30 PCM30C
G.704 G.706, E1, .
: n x 64, , — .
UNUSED: () — (AIS), .
TIMESLOT SELECTION: , . , -.
: 1-31 1-31, — PCM-31. — PCM-30 1-15 1-15, 17-31 16-30. — 16
.7.2.4. TX Set > Pattern Pattern, —
TX, . — PDH SDH, -T
-
20
, .
7.2.4.1PATTERN: Pattern
, . — (PRBS), -T 0.150 0.151, 24- .
INVERT: PRBS. — .
. 0.150 -T — :
PDH — 0.150 -T
PRBS
29 1 8 14,400 /211 1 10
n64 / & 64 /215 1 15
1, 1, 3 DS3220 1 14
1, 1, 3 DS3223 1 23 3
4231 1 31 3, DS3 4
-
21
7.3. PDH7.3.1. RX Set > Hierarchy
Hierarchy, RX.
7.3.1.1NETWORK TYPE: PDH .HIGH RATE: 2, 34 45 /.
7.3.2. RX Set > Interface Interface,
RX, .
7.3.2.1ES PORT: PDH,
.
-
22
TERMINATION: (PMP) -. :
— Terminated: 75 120- , . , .e. — 120 .
— Monitor: , (PMP) . PMP 20 26 . BERcut-SDH — -T G.772 ,
PMP.— Bridge: E1. — E1 . E1 .
LINE CODE: — RX , TX. RX, , TX.
7.3.3. RX Set > Payload Payload, —
RX.
7.3.3.1RATE: , , .FRAMING: , , . Nx64, —
:
-
23
7.3.3.2FRAMING: , , .. —
, , — .
UNUSED: () — (AIS), .
TIMESLOT SELECTION: , , .
7.3.4. RX Set > Pattern Pattern, —
RX, .
7.3.4.1
-
24
OUT OF SERVICE: , , . , , — , — — (LSS).
PATTERN: , , .INVERT: , , .
7.4. SDH
SDH. — TX RX .7.4.1. TX Set > Hierarchy
Hierarchy, TX:
7.4.1.1NETWORK TYPE: —
SDH.TEST RATE: 155M, 622M 2.5G ( TM-
1, STM-4 STM-16 ).MAPPING: AU-4 AU-3
G.707. , VC-4-64C TX300.
-
25
7.4.1.27.4.2. TX Set > Interface
Interface TX, . , .
-
26
7.4.2.1S PORT: :- STM-1, STM-4 STM-
16;- STM-1.CLOCK SOURCE: , —
PDH, .7.4.3. TX Set > Structure
Structure TX, TX.
7.4.3.1VC MAPPING: VC12 VC3.
-
27
BULK: . VC — -T 0.181.
TRIBUTARY: 2M Bulk -.
CHANNEL SELECTION: TX, STM-N, TUG-3, TUG-2 TU-12 .
.- TUG: ,
. , , TUG-2 3TU-12, TUG-3 7TUG-2.
— TU-12: TU-12 36 , 4 9 . 8000 2.304 / — 2.048 /. 63TU-12s STM-1
VC-4., , -T G.707.
C, B, A — :
— C: AUG-4 1 4;- B: AUG-1 1 4;- A: AU-3 1 3. SDH :- STM-16: [C,
B, A];- STM-4: [B, A];- STM-1 AU-3: [A]- STM-1 AU-4: [0]. K, L, M
—:- K: TUG-3 1 3;- L: TUG-2 1 7;- M: TU-11, TU12 TUG-2 1 4.
7.4.4. TX Set > Payload Payload TX,
TX.
-
28
7.4.4.1RATE: 2M 34M, VC,
.FRAMING: :- 2M (E1)
PCM30, PCM31, PCM30C PCM31C. . — .
— 34M (E3) — G.751.
7.4.5. TX Set > Pattern Pattern TX,
TX.
7.4.5.1
-
29
PATTERN: Pattern, — , . (PRBS), -T 0.181, 24- .
INVERT: PRBS. — .
. SDH — — -T G.707. (TSS) — -T 0.181 (Out of Service — OOS) —
SDH. TSS PRBS .(TSS) -T 0.181 PRBS SDHTSS1 223 1 C4 ,
(HP)TSS2 215 1 C3 ,
(HP)TSS3 223 1 C3 ,
(LP)TSS4 215 1 C12 ,
(LP)TSS5 223 1 PDH, 4TSS6 215 1 PDH, 3;
(HP)TSS7 223 1 PDH, 3;
(LP)TSS8 215 1 PDH, 12;
(LP)TSS9 223 1 4-4 —
4-16TSS10 215 1 2-4 —
4-167.5. SDH
7.5.1. RX Set > Hierarchy Hierarchy,
RX. RX , TX, .
-
30
7.5.1.17.5.2. RX Set > Interface
Interface, RX. RX , TX, , , .
7.5.2.1. , ,
SFP, . SFP TX RX 1550 , , SFP.
-
31
7.5.2.1 STM-1/4(155/622 /) STM-1/4/16 (155/622/2468 /)
A1310-IR A-1310-LR A-1550-LR B-1310-IR B-1310-LR B1550-LR
-, ,,/
131015
622LC
NRZ
131040
622LC
NRZ
155080
622LC
NRZ
131015
2488LC
NRZ
131040
2488LC
NRZ
155080
2488LC
NRZ
,, ,
Fabry Perot12741356
2.5-15-8
DFB12801335
1-3+2
DFB14801580
1-3+2
DFB12701360
1-50
DFB1280335
1-2+3
DFB15001580
1-2+3
—,: 155/ 622/ 2488/ ,
PIN
-28-8-28-8
N/A12601600
PIN
-28-8-28-8
N/A12601600
PIN
-28 to-8-28 to-8
N/A12601600
PIN
-23-10-220-180
12701600
APD
-30-15 -29-9-27-9
12701600
APD
-30-15-29-9-28-9
12701600
-
32
7.5.3. RX Set > Structure Structure,
RX. RX , TX, .
7.5.3.17.5.4. RX Set > Payload
Payload, — RX. RX , TX, .
7.5.4.17.5.5. RX Set > Pattern
Pattern, — RX. — RX , TX, , — Out of Service, , ,
-
33
. — , , .
7.5.5.17.6.
Measurements, — , .
7.6.17.6.1.
. MODE: , — .
— Manual: Start/Stop .
-
34
— Timed: . , , . Start /Stop .
— Auto: . , , . Start , , .
. , — M.2100 M.2101.
7.6.2. —
-T, . (None), G.821, G.826, G.828, G.829, M.2100 M.2101. .
7.6.2.1
— G.821: , (ISDN).
(OOS) ;
, ; 30 ; ,
.- G.826: —
. —
(OOS) ;
-
35
, ;
30 .- G.828 : —
. SDH; —
(OOS) , ;
30 .- G.829 :
SDH. SDH; ; , .
— M.2100: PDH.
, PDH; , ; (BIS)
(OOS) (ISM); 15 , 2 24 ; 15- ; PDH,
(RPO).- M.2101. : —
SDH. , SDH; , ; (BIS)
(OOS) (ISM); 15 , 2 24 ; 15- .
. . M.2100 M.2101 -. , — .
7.6.2.1 PDH SDH
G.B21 TSE, —
-
36
3.826 ( -)
TSE,
3.826 (-)
B1, B2, B3, LP-BIP, E1 /E3/E4 FAS,E1 CRC
3.828 (-)
B1, B2, TSE
G.329 (-)
B1, B2, B3, LP-BIP, TSE
M.2100 E1/E3/E4 FAS, E1 CRC, TSEM.2101 B1, B2, B3 HP, LP-BIP,
TSE7.6.3. General —
APS .
7.6.3.1- Audible Alarm: On Off.
.- APS Protocol: .
, (K1/K2) — (APS) SDH — SDH. , APS.
-
37
7.6.4. .
7.6.4.1 Auto-Config BERcut-
SDH. SDH PDH — , . — -, (PMP).
Procedure Start, .
, , -, . -, PASS ( ).
— : ( /
).- Mapping: , —
. 1. 2.5G(STM-16) AU-4.
— Payload: , -T ANSI. -, .
PDH signals: s . 2M, 64 /,BERcut-SDH — .
-
38
8. , —
Results . , .
8.18.1. PDH
8.1.1. Results > Summary Summary .
, -, . — ( ).
8.1.1.1
-
39
8.1.2. Results > Error/Alarm ( 1) Error/Alarm , —
. 1 4 , . , , / .
, , . , :
— : ;- : —
;- : .
, — .
8.1.2.1. ,
, .
Results > Error/Alarm ( 2) 2 4 ,
, . -. , , 100 .
-
40
8.1.2.2Results > Error/Alarm ( 3) 3 4 , —
, . -.
8.1.2.3Results > Error/Alarm ( 4) 4 4 (BERT), —
.
-
41
8.1.2.48.1.3. Results > Event Log
Event log , . — :
— Number (#): , ;- Type: ;- Start: , ;- Dur/Count: ,
, () (). : :::;
— s: , .
8.1.3.1
-
42
8.1.4. Results > Signal Signal
.
8.1.4.1FREQUENCY: —
. E1 — 120-, 75- .
— Current: ;- Offset: —
;- M ( ): —
, ;- Max ( ):
, ; M ( ) Max ( )
, , . -, .
8.1.4.1 PDH —
E1 PDH 2048 / 112 / (54,6 )E3 PDH 34368 / 846 / (24,6 —
)E4 PDH 139264 / 2730 / (19,6
)DS1 T- 1544 / 57 / (36,6 )DS3 T- 44736 / 1101 / (24,6 —
-
43
)
LEVEL: . — -, .
8.1.4.2 PDH — G.703
—
1 2/
HDB3 75 -BNC120 -RJ45
: — 2,37: 2,37: — 3,0: 3,0 c 20 26
3 34/
HDB3 75 -BNC
: — 1,0: 1,0 c 20 26
4 140/
CMI 75 -BNC
: — 1,0: 1,0 c 20 26
8.1.5. Results > Analysis -, :-T G-: ,
, ;-T M-: —
(BIS) .
— .8.1.6. Results > Histograms
Histograms , — , . , BER. , — .
-
44
8.1.6.1 —
. -, . — , + -. , , -.
8.1.6.1 1
LOS AIS LOF LOMF PDI
E1.
-
45
8.1.6.2 8.1.6.2 1
CODE (HBD3, AMI)FAS CRC REI
BER .
8.1.6.3 8.1.6.3BERT
LSS Bit
-
46
8.1.7. Results > Bar Bar ,
, . . , .
8.1.7.1 ,
, . — , + .
e, . , -. .
-
47
8.1.7.28.2. SDH
8.2.1. Results > Summary Summary —
. , — , -, SDH . ( ).
8.2.1.18.2.2. Results > Errors/Alarms ( 1)
Errors/Alarms , — .
1 , . — , , / .
, , . , :
— : ;- : —
;- : .
, .
-
48
8.2.2.1. ,
, .
(LED) . 8.2.2.1
SDHRS MS AU HP TU LP E1 2 / ( )Pat (PRBS, , —
)
-TG.707 0.150.
8.2.2.2 BER
LOS LOS , (STM-N) , BER 1-3. — , — . LOS ,
TSE
-
49
LSS — PRBS , , — , , — . , -, :1) > 0,20 —
— LOF
, OOF 3 . OOF , — , OOF , SDH () -. OOF B1 , B1 byte(BIP-8)
STM-N. , — —MS-AIS , 6,7,8 K2 «111» MS-RDI , 6,7,8 K2 «110» MS-REI STM-1 ,
M1, — TS #3, STM-4/16 , M1, — TS #7, B2 , B2 (BIP-24x N) STM-N. N x
24 — ,— AU-AIS
, H1 H2
AU-LOP , N — , N = 8, 9 10, — 1001 (NDF)AU-
NDF
(HO) —
-
50
HP-UNEQ
HO, C2 «00H» — HP-RDI , 5, 6, 7 G1 — 100 111
HP-TIM (TIM) , J1 . , TIMHP-PLM ,
B3 C VC-3, VC-4 , B3 byte(BIP-8) VC-N (N = 3, 4). , -HP-RE1 ,
1-4 G1 — 0001 1000TU-AIS
, V1 V2 000
TU-LOP , N (N >6
-
51
PDH .Results > Errors/Alarms ( 2) 2 SDH, —
, . . [ET] . , , .
8.2.2.2Results > Errors/Alarms ( 3) 3 RS MS, —
, . . [ET], , .
8.2.2.3
-
52
, [RS] [MS] , .
Results > Errors/Alarms ( 4) 4 [HP], —
, . .
8.2.2.4Results > Errors/Alarms ( 5) 5 [LP], —
, . .
8.2.2.5Results > Errors/Alarms ( 6)
-
53
6 PDH, — , . -.
8.2.2.6
Results > Errors/Alarms ( 7) 7 PDH,
. -.
8.2.2.78.2.3. Results > Event Log
Event log — , . —
-
54
; , , , , () (). , — .
8.2.3.18.2.4. Results > Signal ( 1)
Signal . 1 ( ) STM-1E ( ) STM-10, STM-40 STM-160.
(LOS) , .
8.2.4.1Results > Frequency ( 2)
-
55
. SDH (BNC) — (SFP) .
8.2.4.2 ,
, -. — , . — , BERcut-SDH — (PMP). , , , — . SDH .
8.2.4.1 SDH
, / , 155520 < 4,6622080 < 4,6
2366320 < 4,6
8.2.5. Results > Histogram ( 1) Histogram , —
. — , BER.
1 , (SOH).
-
56
8.2.5.1. —
. -, . — , — + .
Results > Histogram ( 2) 2 , (SOH).
8.2.5.2Results > Histogram ( 3) 3 , —
(AU). :- AU-AIS (AU );- AU-LOP (AU ).
-
57
8.2.5.3Results > Histogram ( 4) 4 ,
(HP). :- HP-UNE (HP );- HP-PLM (HP );- HP-TIM (HP );- HP-RDI (HP
);- B3 ;- HP-REI (HP ).8.2.5.4Results > Histogram ( 5) 5 ,
(TU). ;- TU-LOM (TU );
-
58
— TU-AIS (TU );- TU-LOP (TU ).
8.2.5.5Results > Histogram ( 6) 6 ,
(LP). :- LP-UNE (LP );- LP-PLM (LP );- LP-TIM (LP );- LP-RDI (LP
);- LP-RFI (LP );- LP-BIP (LP );- LP-REI (LP )8.2.5.6Results > Histogram ( 7)
-
59
7 , . .
8.2.5.7Results > Histogram ( 8 , . —
.
8.2.5.8Results > Histogram ( 9) 9 , —
.
-
60
8.2.5.98.2.6. Results > Graph Bar
Bar , — , . — :
— FAS;- B1;- B2;- MS-REI;- B3;- HP-REI;- LP-BIP;- LP-REI;- PDH,
. , —. , .
-
61
8.2.6.18.2.7.
-T G.821
n x 64 / — .
ES, SES, AS UAS :- FAS (FAS 2, FAS 34, FAS 140);- CRC;- E;- ( —
TSE). ,G.821 (TSE):- ;- n x 64 /;- ;- E1, E2, F1, F2, D1-D3 D4-D12;- /
—0,1 100%.. -T G.821 ,
, . G.821 , — .
: (ES): ,
. (SES):
, 10-3.
-
62
(UAS): SES. , (SES).
(AS): , — .
8.2.7.1 -T G.826 G.826
, .
: ES, SES, BE, BBE UAS. / —
0,1 100%. (ISM)
. (OOS) ,
.: (ES): ,
. (SES):
, 30 % . (BE): . (BBE): ,
SES.
-
63
(UAS): SES. , (SES).
. G.821 G.826 30 .
8.2.7.2 -T G.828G.828 —
G.826.- ES, SES, BBE, UAS SEP.- / —
0,1 100%. G.828 :- B1;- B2;- MS-REI;- B3;- HP-REI;- LP-BIP;-
LP-REI;- (TSE). ,, REI. :- ;- ;- E1/E2 (), F1/F2 ( ), D1-D3
D4-D12 (DCC) SDH (SOH POH).. , G.828 —
.
-
64
8.2.7.3 -T G.829G.829 —
. ES, SES, BBE UAS. G.829 :- B1;- B2;- MS-REI;- (TSE). ,
, REI. :- ;- ;- E1/E2 (), F1/F2 ( ), D1-D3
D4-D12 (DCC) SDH (SOH POH).
-
65
8.2.7.4 -T M.2100M.2100 —
. 15- 24- . , — .
ES, SES UAS. / —
S1 S2 ES SES. S1 S2:- : 0,1 100 %;- (BISO): 0,1
100. M.2100 :- FAS (FAS2, FAS34, FAS140);- CRC-4;- EBIT;- (TSE).
—PCM-30/31 CRC. :- ;- ;- n x 64 /;- E1, E2, F1, F2, D1-D3 D4-D12.
M.2100 , —.
-
66
8.2.7.5 -T M.2101 M.2101 M.2100 ,
SDH. ES, SES, BBE, SEP UAS. / —
S1 S2 ES, SES, BBE SEP. S1 S2:- : 0,1 100 %;- (BISO): 0,1
100. M.2101 :- B1;- B2;- MS-REI;- B3;- HP-REI;- LP-BIP;-
LP-REI;- (TSE). ,, REI. :- ;- ;- E1/E2 (), F1/F2 ( ), D1-D3
D4-D12 (DCC) SDH (SOH POH).. M.2101 , —
.
-
67
8.2.7.6
-
68
9. / —
. Alarm/error,
. , . — PDH SDH.
9.19.1.
PDH T-:
PDH:- E1: LOS, LOF, AIS, RDI;- E3: LOS, LOF, AIS, RDI;- E4: LOS,
LOF, AIS, RDI;- DS1: AIS, Yellow, idle, LOS, LOF;- DS3: LOS, LOF,
OOF, AIS, .: (/). SDH:
-
69
9.1.1 SDH:- STM-1/4/16 ( ): LOS, LOF, MS-AIS, MS-
RDI, RS-TIM, AU-LOP, AU-AIS, HP-UNEQ, HP-PLM, HP-RDI, HP-TIM,
TU-LOM, TU-LOP, TU-AIS, LP-UNEQ, LP-PLM, LP-RDI, LP-RFI,
LP-TIM;— ( ):2M-AIS, 2M-LOF, 2M-RDI, 34M-AIS, 34M-LOF, 34M-RDI,
45M-AIS;: (/) .
9.2. SDH, PDH T-:
9.2.1 PDH T-: PDH:
-
70
— E1: Code, FAS, CRC, REI, E-bit, Bit;- E3: Code, FAS, Bit;- E4:
Code, FAS, Bit;- DS1: Code, FAS, Bit;- DS3: Code, FAS, Bit. SDH:
SDH:- STM-1/4/16: FAS, B1, B2, MS-REI, B3, HP-REI, LP-BIP, LP-REI,- : 2M-FAS, 2M-CRC, 2M-REI,
34M-FAS, 45M-FAS, 1.5M-FAS. .
:- Single: ,
;- Count:
, ;- Rate: 110-3 510-6. —
, SDH PDH .
9.2.2Alarm Generation / Error Insertion ( ) —
, .
-
71
9.2.3
-
72
10. SDH SDH . —
SDH Functions, .SDH Functions > Shortcuts
10.1Overhead Analyzer: (SOH)
(POH) .Overhead Generator: —
(SOH) (POH) .Pointer Tasks: AU TU
AU TU. , — -T G.783, .
Trace Identifier: — J0, J1 J2 -, G.831.
Payload Labels: C2 V5, VC .
Overhead BERT: BERT — DCC ( D1-D4 D5-D12), E1 E2 F1.
APS sting: (APS). , — .
TCM Tasks: — N1 N2 TCM — .
-
73
Tributary Scan: — . VC-12.
10.1. SDH Functions > Overhead Analyzer Overhead Analyzer,
OH,. :- SOH RX, , —
(RS MS);- POH RX, , —
;- Summary, (J0, J1, J2), APS (K1,
K2), (S1) HP (C2) LP(V5).
10.1.1 —
, — . — .
SOH
. A1/A2:- A1/A2 STM-1 —
: A1 : 11110110 (Hex F6); A2 : 00101000 (Hex 28);
— A1 A2 ;
-
74
— STM-N (3 x N) A1 — (3 x N) A2
10.1.2 J0 (RS-Trace):- ;- 16 64 ()
( CRC-7), , — ;
— -.
B1 (RS-BIP):- 8-
.- STM-1 —
;- RS
STM-1 .
-
75
10.1.3 E1 ( RS):- ,
, . F1 ( RS):- ;- —
;- .
10.1.4 D1/D2/D3 (RS DCC):- (DCC);- D1, D2 D3 192
/ , (OAM);- ;- BER.
-
76
H1/H2/H3 ( AU):- STM-1 STM-n —
MS.
10.1.5 B2 (MS-BIP):- 24- ,
, -;
— STM-1, — ;
— MSOH STM-1.
10.1.6
-
77
K1 ( APS):- —
;- APS -T G.783
;- 1-4 ( G.783):
1111 ; 1110 ; 1101 , ( 1:n); 1100 , ; 1011 , (
1:n); 1010 , ; 1000 ; 0110 ; 0100 ; 0010 ( —
); 0001 ; 0000 ; ;
— 5-8 , APS: 0000 ; 00011110 1 14; 1111 .
10.1.7 K1 ( APS):
-
78
— — ;
— APS -T G.841 ;
— 1-4 G.841: 1111 ; 1110 (); 1101 (); 1100 (); 1011 (); 1010 ();
1001 (); 1000 (); 0111 (); 0110 (); 0101 ; 0100 (); 0011 (); 0010
(); 0001 (); 0000 ;— 5-8 ID: 0000 ; 00011110 1 14; 1111 .
K2 ( APS):- -T G.783;- —
;-
(AIS) (RDI);- 1-4 ;- 5 APS:
1+1; 1:n;
— 6-8: MS-RDI; MS-AIS;
— . K2 ( APS):- -T G.841;- —
;
-
79
— l(AIS) (RDI);
— 1-4 ID;- 5 — :
— — ;
— 6-8: ; ; ; MS-RDI; MS-AIS;
— .
10.1.8 D4-D12 (MS-DCC)- (DCC) —
576 / , — (OAM);
— BER.
-
80
10.1.9 S1 ( ):-
, , — ;
— 1-4 ;- 5-8:
0000 ; 0010 G.811 PRC; 0100 G.812 ; 1000 G.812 ; 1011 G.813 ;
1111 ;— .
-
81
10.1.10 E2 ( MS):- 64
/;- ,
;- , .
10.1.11 POH
. J1 ( HP):- VC-N ;- ,
SDH ,
-
82
— ;
— 15- (CRC-7), — ;
— 64- ;- VC-4.
10.1.12 B3 (HP BIP):- , ;- VC-
4;- B3 .
10.1.13
-
83
C2 ( HP):- VC-n;- C2.
C2 -T G.7071-4
5-9
— —
0000 0000 00 0000 0001 01 0000 0010 02 TUG0000 0011 03 TU-n0000
0100 04 34 /45 / C30001 0010 12 140
/ C40001 0011 13 ATM0001 0100 14 DQDB ( —
) (AN)0001 0101 15 FDDI (-
)0 001 1000 18 HDLC/LAPS0001 1010 1A 10 Gigabit Ethernet (IEEE
802.3)0001 1011 IB (GFP)0001 1100 1C 10 Gigabit0010 0000 20 —ODU-k1111 0000 FE , —
— 0.1811111 1111 FF VC-AIS (TCM)
-
84
10.1.14 G1 ( HP):- ;- —
, ;
— 1-4: (HP-REI) , B3;
— 5: (HP-RDI), 1, ;
— 6-7: RDI (HP-PLM), (HP-TIM, HP-UNQ) — (HP-AIS, LOP).
F2 ( HP)- ;- VC-4 —
.
-
85
10.1.15 H4 ( TU):- ;- —
. F3 ( LP)- ,
.
10.1.16 K3 (HP APS):- 1-4 VC-3/4.- 5-8 . N1 (HP TCM):
-
86
— — (HP) — VC-4, VC-4 VC-3.
— 1-4: — (IEC) G.707;
— 5: TC-REI , —
— 6: OEI , — VC-n;
— 7-8: 76 . 10.1.1 N1 — G.707
1 2 3 4 5 6 7 8 IEC TC-REI OEI TC-API, TC-RDI,
ODI, —
: 1-8 > (FAS). 9-72 > —
(TC-API). 73-76 > TC-RDI,
. 74 > ODI, —
, — — AU-n/TU-n AU/TU-AIS.
73-76 > .
10.1.17
-
87
V5 ( LP):- , —
;- —
;- 1-2 (BIP-2);- 3 LP-REI (0 = , 1 = );- 4 LP-RFI (0 = , 1 = );-
5-7 VC-12:000 ; 001 ( ); 010 011 — 100 — 101 010 (TSS4), .181; 111
VC-AIS;— 8 LP-RDI, 0, 1 — VC12 (AIS).
10.1.2 V5 — G.707
1 2 3 4 5 6 7 8BIP-2 LP-REI LP-RFI TC-REI LP-RDI
J2 ( LP):- 16- —
, — ;
— , J0 J1.
10.1.18
-
88
N2 (LP TCM):- LP (LP-
TCM) VC-2, VC-11 VC-12.- 1-2: BIP-2
;- 3: 1;- 4: AIS (0 = ; 1 = —
);- 5: TC-REI, —
;- 6: OEI VC-n ;- 7-8: 76 . 10.1.3 N2 — G.707
1 2 3 4 5 6 7 8BIP-2 1 I-AIS TC-REI OEI TC-API, TC-RDI,
ODI, —
: 1-8 > (FAS). 9-72 > —
(TC-API). 73-76 > TC-RDI,
. 74 > ODI, —
, — — AU-n/TU-n AU/TU-AIS.
73-76 > .
-
89
10.1.19 K4 ( LPl):- 5-7 V5 101 ( = 5),
K4 , : 32- ; 1 ; 2 ; 3 4 LP
APS; 5, 6, 7 ; 8 ; 12-19 32- , —
. 10.1.2
K4 — G.7071 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
22 23 24 25 26 27 28 29 30 31—
0 R R R R R R R R R R R
10.1.3 K4 — G.707
1 2 3 4 5 6 7 8 —
—
Summary
-
90
Summary , SDH:
— Column #1 — ;- Column #2 ( —
);- Column #3 (,
)..- (SP) —
;- , —
. C2 PLM( ), .e. — .
10.1.20
-
91
10.2. SDH Functions > Overhead Generator
10.2.1 Overhead Generator,
OH, . :- SOH TX, , —
. J0, K1, K2, S1:
; —
; . —
.. —
OH; — , , — , APS, TCM BERT. .
-
92
10.2.2- POH TX, , —
. J1, C2,H4, G1, K3, J2, V5 K4:
; —
; . —
.. —
OH; — , , — , APS, TCM BERT. .
-
93
10.2.3- Summary, (J0, J1,
J2), APS (K1, K2), (S1), HP(C2) LP (V5). , Overhead
Analyzer.10.3. SDH Functions > Pointer Tasks Pointer Tasks, —
.
10.3.1 .- SDH —
. — , . (AU)
-
94
(TU) , — :
AU:- SS 5 6 H1 SDH [10],
SONET [00], [01] [11];- H1 H2 () —
AU-n;- LOP ( );- PJE NJE;- NDF ( ). NDF , 3
4 1001, , 3 0110;
— ; TU:- ;- LOP ( );- PJE NJE;- NDF ( );- .
10.3.2- Generator —
: AU:- SS: 5 6 H1,
SDH [10], SONET [00] [01] [11];- : —
NDF ( ) . AU-3/4 0 782;
-
95
— (INC) (DEC) — ;
TU:- : 0 784 (TU-3)
0 139 (TU-12);- (INC) (DEC) —
.
10.3.3- G.783 Sequences ( )
. -T G.783:- 87-3: 87
, -;
— 43-44: 43 , — 44 — , , ;
— 86-4: 86 , -.
-
96
10.3.4.1.
, — . — , , .
2. , 30- .
10.4. SDH Functions > Trace Identifier Trace Identifier,
—, . () .
10.4.1 (TX)- J0 [RS]: e : 1 16 —
;- J1 [HP]: :
-
97
16 64 ;
VC-4;- J2 [LP]: : 16 64
..
Trace, — QWERTY.
10.4.2 (RX)- J0 [RS]: e : 1 16
; TIM ( —
);- J1 [HP]: : 16 64
; TIM ( —
);- J2 [LP]: : 16 64
; TIM ( —
);.
Trace, — QWERTY.
-
98
10.4.310.5. SDH Functions > Payload Labels
C2 V5, VC -.
10.5.1 Payload Label,
. — .
C2 [HP]: VC-n;
-
99
TX RX ;
RX PLM ( ).
10.5.2- V5 [LP]: TX RX
;
RX PLM ( ).
10.5.3
-
100
10.6. SDH Functions > Overhead BERT . —
BERT DCC ( D1-D4 D5-D12), — E1 E2 F1.
10.6.110.7. SDH Functions > APS est
— (APS) . APS — SDH . — K1 K2 .
10.7.1 APS SDH
-T G.783 G.841 —
-
101
. , 50 . — :
— (SF) (LOS), MS-AIS, BER>1 x 103;
— (SD) , BER . , 10 5 109.
:1. BERcut-SDH —
, — SDH.
2. , , .
3. , — (AIS) (TSE) 10 4.
4. BERcut-SDH , — AIS TSE , , — .
AIS BER > 2 10-4
AIS BER > 2 10-4
APS 200
APS 200
APS 400
APS 400
10.7.2 APS est,
APS, . :- Sensor: ,
APS. MS-AIS, AU-AIS, TU-AIS TSE ( ).- Switch Time Limit: 50 200
, 50-.
-
102
— Gate Time: 500 4 . , .
— Start: , .
10.7.310.8. SDH Functions > Tandem Connection Monitoring
(TCM).
10.8.110.9. SDH Functions > Tributary Scan
VC12 — , .
-
103
10.9.1
/ (ADM) . -, , STM-1 63 VC-12, aSTM-4 252 VC-12 , .
BERcut-SDH BER SDH ( C12) AU-4, AU-3. , SDH, — . :
— K.L.M.: -T;- : (OK);- J2: , LP;- : V5.
-
104
11. PDH PDH . —
PDH Functions, , .
11. 111.1. PDH Functions > E1 / E3 Pulse Mask
E1(2,048 M/) E3 (34,368 M/). , : , — .
— , -T G.703. — . , , -. -, .e. , . E1, BERcut-SDH — 120 — 75 .
, 75 120 — , : — 75- 2,37 10%, — 120- 3,0 10%.G.703 E1 , — , , , , — c . BERcut-SDH, , — TX (PMP) —
-
105
. , .
11.1.111.3. PDH Functions > E1 APS est ( )
.11.4. PDH Functions > E1 Frame Words
, E1 . NFAS o p -.
11.4.1, (NFAS)
1 2 3 4 5 6 7 8Si (M) 1 A Sa4 Sa5 Sa6 Sa7 Sa8
— 1: (M — CRC PCM30C PCM31C).
— 2: 1 FAS.- 3: .- 4 8: Sa4 Sa8 .TX: Sa4 Sa8 —
. Sa 1, — .
RX: Sa4 , , .
-
106
11.4.1
-
107
12. , —
‘Profiles’. PDH SDH — . Profiles, .
12.1 PDH SDH, —
, Save as New. — . -, , — (PDH SDH). — .
-
108
13. 13.1.
, .
13.1.113.2.
, .
13.2.1
13.3. , .
-
109
13.4. , .
13.4.113.5.
, .13.6.
, .
-
110
14. : , —
. — , LCD, , LCD ( , ,SFP, USB, ) (1) .
: METROTEK , — . METROTEK, , —
, ,
, , , METROTEK — (30) .
: METROTEK , . — METROTEK, ,
/ , —
, , , , METROTEK — (30) .
, METROTEK -, , , — -. METROTEK , — . , — , ( ) , .
: , (, / ).
: METROTEK , o, -. :
; —
() METROTEK; ; , —
, ;
-
111
.
-
112
15.
RJ-48 (120 ) : 1,544 /, AMI B8ZS () 2,048 /, H3 AMI BNC (75 ) :
2,048 /, H3 & AMI 34,368 /, H3 44,736 /, B3ZS () 139,264 /, CMI
() 155,520 /, CMI () ITU-T G.703, G.823, G.824, G.825, G.772 ANSI
T1.102 ITU-T G.703 : 2.048 / (E1); : 6 ( ) (PMP): 26 (20 , 6 ) : 6
( ) 34,368 / (E3); : 12 ( ) (PMP): 26 (20 , 6 )1.544 / (DS1); : 6 ( ) (PMP): 26 (20 , 6 ) : 6 ( ) 44,736 /
(DS3); Terminate: 6 ( ) Monitor (PMP): 26 (20 , 6 ) 139,264 / (E4)
155,520 / (STM-1E); : 12.7 ( ) (PMP): 26 (20 , 6 )l: 2,048/, 3.5 ppm stability per ITU-T G.812 : 2,048 / SMA :
2,048 ( TTL) : 2,048 / (H3) Tx: -
113
25,000 ppm 0.1 ppm —
Small Form Factor Pluggable (SFP)
Multi Source Agreement (MSA) ROHS compliant and Lead Free per
Directive 2002/95/EC : -10C to 70C : Class 1, FDA/CDRH, EN (IEC)
60825 EN (IEC) 60950 ITU-T G.957 SDH : 2, 1SDH
SOH
STM-1 ( VC-n); PDH (
ITU-T 0.150) STM-4 ( VC-n); PDH (
ITU-T 0.150) Bulk TSS (per ITU-T 0.181) STM-16 ( VC-n); PDH
(ITU-T 0.150) Bulk TSS (per ITU-T 0.181) ( ITU-T G.707) C-12 (
E1,-) C-3 ( E3 DS3)
AU-3 AU-4 C-4 (E4) C-4-4c (STM-4 STM-16) C-4-16c (STM-16)
-
114
C-11 ( DS1)
PRBS: 211-1, 215-1, 220-1, 223-1, 231-1: —
: 0000, 1111, 1010, 1000 1100 : 24
O : FAS, B1, B2, MS-REI, B3, HP-REI, LP-REI, LP-BIP, slips : (1
x 10-3 5 x 10-6) : FAS, B1, B2, MS-REI, B3, HP-REI, LP-BIP,
LP-REI,: LOS, LOF, MS-AIS, MS-RDI, RS-TIM, AU-LOP, AU-AIS, HP-UNEQ,
HP-PLM, HP-RDI, HP-TIM, TU-LOM, TU-LOP, TU-AIS, LP-UNEQ, LP-PLM,
LP-RDI, LP-RFI, LP-TIM, 2M AIS, 2M LOF, 2M RDI : (/) : LOS, LOF,
OOF, RS-TIM, MS-AIS, MS-RDI, AU-AIS, AU-LOP,HPUNEQ, HP-PLM, HP-TIM, HP-RDI, TU-LOM, TU-AIS, TU-LOP, LPUNEQ,
LP-PLM, LP-TIM, LP-RDI, LP-RFI/, —
, — ITU-T G.707, G.703, 0.151 0.181
( G.783) ( G.841) — SOH/POH
, ASCII S1 C2 HP J0 (16 ) ASCII J1 (16 64 ) ASCII J2 (16 64 )
ASCII K1, K2 APS V5 LP RSOH: -
115
J0 : 1 16 — ASCII CRC-7
MSOH: K1, K2 APS ITU-T G.783 G.841 S1 HO-POH (VC-4, VC-3): J1 :
16 ASCII CRC-7 64ASCII C2 H4 / G1 ( 5) — ( RDI) K3 ( 1-4) APS LO-POH (VC-3): J1 :
16 ASCII CRC-7 64ASCII C2 G1 ( 5) — ( RDI) K3 (1-4) APS LO-POH (VC-12, VC-11): V5
( 5-7) LP J2 : 16 ASCII CRC-7 64ASCII K4 ( 3-4) LP APS
BERT : PRBS DCC ( D1-D3 D4-D12)
E1, E2, F1, N1 N2 PRBS: 223 -1, 220 -1, 215 -1, 211 -1 ( —
) ,
, , —
, , New Data Flags (NDF) (ppm AU/TU)
, ,
/ VC-12 ,
BER
-
116
PDH
( E1) ( E1, DS1 )
2,048 / (E1) / CRC ITU-T G.704 (PCM30, PCM30C, PCM31, PCM31C)
N/M x 64 / N=1-30 34,368 / (E3) ITU-T G.751 1,544 / (DS1) SF (D4),
ESF ANSITelcordia N x 64 /, N x 56 / N=1-24 44,736 / (DS3) M13 C-Bit
ParityITU-T G.752 ITU-T G.704 139,264 / (E4) ITU-T G.751
:
PRBS: 211-1, 215-1, 220-1, 223-1, 231-1: : 0000, 1111, 1010,
1000 and 1100 : 24:
2,048 / (E1): Code, FAS, CRC, EBIT, 34,368 / (E3): Code, FAS, 2M
FAS, 2M, ( 1 x 10-3 5 x 10-6) 1,544 / (DS1): Code, FAS, Bit, Frame,
CRC 44,736 / (DS3): Code, FAS, MFAS, P/C-Parity, 139,264 / (E4):
Code, FAS,: 2,048 / (E1): Code, FAS, CRC, E-BIT 34,368 / (E3): Code, FAS,
(DS1, DS3 and E4) Code, FAS, MFAS, 2M CRC, P/C-Parity, -
117
: 2,048 / (E1): LOS, AIS, LOF, RDI 34,368 / (E3): LOS, AIS, LOF,
RDI, 2M LOF, 2M RDI : (/)1,544 / (DS1): AIS, , idle, LOS, LOF 44,736 / (DS3): LOS, LOF,
OOF, AIS, Parity 139,264 / (E4): AIS, FAS RDI: 2,048 / (E1): LOS, AIS, LOF, LOMF, RDI LSS 34,368 / (E3): LOS,
AIS, LOF, RDI LSS (T-Carrier DS1/DS3) LOS, AIS, LOF, OOF, IDLE,
YELLOW LSS, ES, %ES, SES, %SES, UAS, %UAS, EFS, %EFS,AS, %AS, : , :
ITU-T G.821: ES, EFS, SES, DM, UAS HRP 1% 100%
ITU-T G.826: EB, BBE, ES, EFS, SES, UAS. HRP 1% 100%.
(ISM) B1, B2, B3, FAS, CRC Code (E1).
(OOS) (TSE) ITU-T G.828: ES, EFS, SES, BBE, SEP, UAS HRP 1%
100% ITU-T G.829: ES, EFS, SES, BBE, UAS RSOH (B1),
MSOH (B2) TSE ITU-T M.2100: ES, EFS, SES, UAS HRP 1% 100%.
(MTCE)(BIS). ITU-T M.2101: ES, EFS, SES, BBE, SEP, UAS HRP
1% 100%. (MTCE)
(BIS). TSE, HP-BIP (B3), MS-BIP (B2),
RS-BIP (B1) LP-BIP (V5)
: , —
, ,
-
118
: / ppm : 1Hz TIE
: : 1. 10 : 1 1 U.I.
: , ,
, , —
/ SDH/PDH / —
SDH/PDH PDH
: 2,048 / (E1) 34,368 / (E3) : : : , —
, : G.703 T-Carrier : 1,544 / (DS1) 44,736 / (DS3) C: G.703,
ANSI T1.102, T1.403, T1.404(APS) SDH PDH : PDH (E1), SDH : 1 10 : 1 : MS-AIS, AU-AIS,
TU-AIS, B2 APS (K1/K2) — LOS, LOF, AIS, TSE : , , -
119
ITU-T G.783
TANDEM CONNECTION MONITORING (TCM) N1 N2 : TC-IEC, TC-BIP,
TC-REI, OEI : TC-RDI, TC-UNEQ, TC-LTC, TC-AIS, TC-ODI , , : TC-IEC,
TC-AIS, TC-REI, TC-RDI, TC-OEI, TC-LTC, TC-UNEQ, TC-ODI, TC-TIM
APId (Access Point Identifier)210 x 100 x 55 ( x x ) 1. Li-Ion > 3 AC : 100-240 AC, 50-60
Hz15 DC, 3.5A -10C to 50C : -20C to 70C 5% 95% : 3.5QVGA 320×240 :
1m2. 3. 4. 4.1. 4.2. 4.3. 4.4.
5. 5.1. 5.1.15.2. RJ485.3. BNC5.4. SFP5.5. SMA5.6. LED
6. 7. 7.1. 7.2. PDH7.2.1. TX Set > Hierarchy7.2.2. TX Set
> Interface7.2.3. TX Set > Payload7.2.4. TX Set >
Pattern7.3. PDH7.3.1. RX Set > Hierarchy7.3.2. RX Set >
Interface7.3.3. RX Set > Payload7.3.4. RX Set > Pattern7.4. SDH7.4.1. TX Set > Hierarchy7.4.2. TX Set >
Interface7.4.3. TX Set > Structure7.4.4. TX Set >
Payload7.4.5. TX Set > Pattern7.5. SDH7.5.1. RX Set > Hierarchy7.5.2. RX Set >
Interface7.5.3. RX Set > Structure7.5.4. RX Set >
Payload7.5.5. RX Set > Pattern7.6. 7.6.1. 7.6.2. 7.6.3. 7.6.4.
8. 8.1. PDH8.1.1. Results > Summary8.1.2. Results >
Error/Alarm ( 1)8.1.3. Results > Event Log8.1.4. Results >
Signal8.1.5. Results > Analysis8.1.6. Results >
Histograms8.1.7. Results > Bar8.2. SDH8.2.1. Results > Summary8.2.2. Results >
Errors/Alarms ( 1)8.2.3. Results > Event Log8.2.4. Results >
Signal ( 1)8.2.5. Results > Histogram ( 1)8.2.6. Results >
Graph Bar8.2.7.9. /9.1. 9.2.
10. SDH10.1. SDH Functions > Overhead Analyzer 10.1.2010.2.
SDH Functions > Overhead Generator10.3. SDH Functions >
Pointer Tasks10.4. SDH Functions > Trace Identifier 10.4.310.5.
SDH Functions > Payload Labels 10.5.310.6. SDH Functions >
Overhead BERT10.7. SDH Functions > APS est 10.7.310.8. SDH
Functions > Tandem Connection Monitoring (TCM) 10.9. SDH
Functions > Tributary Scan 11. 111.1. PDH Functions > E1 / E3
Pulse Mask 11.1.111.3. PDH Functions > E1 APS est ( )11.4. PDH
Functions > E1 Frame Words11.4.113. 13.1. 13.2. 13.2.113.3. 13.4. 13.5. 13.6.
14. 15. SDH
- Home
- Documents
- Manual BERcut SDH
BERcut-SDH Анализатор параметров цифровых трактов РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
- Download
Embed Size (px)
TRANSCRIPT
-
BERcut-SDH
-
2
1.
……………………………………………………………………………………………………….42.
………………………………………………………………………………………53.
…………………………………………………………………………..64.
………………………………………………………………………………………..74.1.
………………………………………………………………………………..74.2.
………………………………………………………………………………………………74.3.
………………………………………………………………….84.4.
…………………………………………………………………………………………………..85.
…………………………………………………………………………………..105.1.
…………………………………………10
5.1.1………………………………………………………………………………………………..105.2.
RJ48
…………………………………………………………………………………….105.3.
BNC……………………………………………………………………………………..105.4.
SFP…………………………………………………………………..105.5.
SMA……………………………………………………………………………………..115.6.
LED……………………………………………………………………………………………………….116.
…………………………………………………………………………………………….137.
…………………………………………………………………………………………………….147.1.
………………………………………………………………………………………147.2.
PDH……………………………………………………………………167.2.1. TX Set >
Hierarchy…………………………………………………………………………….167.2.2.
TX Set >
Interface……………………………………………………………………………..167.2.3.
TX Set >
Payload………………………………………………………………………………177.2.4.
TX Set > Pattern
……………………………………………………………………………….197.3. PDH
……………………………………………………………………………………….217.3.1.
RX Set > Hierarchy
……………………………………………………………………………217.3.2.
RX Set >
Interface……………………………………………………………………………..217.3.3.
RX Set >
Payload………………………………………………………………………………227.3.4.
RX Set >
Pattern……………………………………………………………………………….237.4.
SDH……………………………………………………………………247.4.1.
TX Set >
Hierarchy…………………………………………………………………………….247.4.2.
TX Set >
Interface……………………………………………………………………………..257.4.3.
TX Set > Structure
…………………………………………………………………………….267.4.4.
TX Set >
Payload………………………………………………………………………………277.4.5.
TX Set > Pattern
……………………………………………………………………………….287.5.
SDH………………………………………………………………………297.5.1.
RX Set > Hierarchy
……………………………………………………………………………297.5.2.
RX Set >
Interface……………………………………………………………………………..307.5.3.
RX Set >
Structure…………………………………………………………………………….327.5.4.
RX Set >
Payload………………………………………………………………………………327.5.5.
RX Set >
Pattern……………………………………………………………………………….327.6.
……………………………………………………………………….337.6.1.
…………………………………………………………………………..337.6.2.
…………………………………………………………………………347.6.3.
…………………………………………………………………………….367.6.4.
…………………………………………………………………….378.
…………………………………………………………………………………………………..388.1.
PDH
…………………………………………………………………………………….388.1.1. Results >
Summary……………………………………………………………………………388.1.2.
Results > Error/Alarm ( 1)
……………………………………………………..398.1.3.
Results > Event
Log…………………………………………………………………………..418.1.4.
Results >
Signal………………………………………………………………………………..428.1.5.
Results >
Analysis……………………………………………………………………………..438.1.6.
Results >
Histograms…………………………………………………………………………43 -
38.1.7. Results > Bar
……………………………………………………………………………………468.2.
SDH
…………………………………………………………………………………….478.2.1. Results >
Summary……………………………………………………………………………478.2.2.
Results > Errors/Alarms (
1)…………………………………………………..478.2.3.
Results > Event
Log…………………………………………………………………………..538.2.4.
Results > Signal ( 1)
…………………………………………………………….548.2.5.
Results > Histogram ( 1)
……………………………………………………….558.2.6.
Results > Graph Bar
……………………………………………………………………608.2.7.
…………………………………………………………………………619.
/………………………………………………………………………………….689.1.
……………………………………………………………………..689.2.
………………………………………………………………………………………6910.
SDH………………………………………………………………………………………………..7210.1.
SDH Functions > Overhead Analyzer
………………………………………………………..73
10.1.20…………………………………………………………………………………………….9010.2.
SDH Functions > Overhead
Generator………………………………………………………9110.3.
SDH Functions > Pointer
Tasks………………………………………………………………..9310.4.
SDH Functions > Trace
Identifier………………………………………………………………96
10.4.3………………………………………………………………………………………………9810.5.
SDH Functions > Payload Labels
……………………………………………………………..98
10.5.3………………………………………………………………………………………………9910.6.
SDH Functions > Overhead BERT
………………………………………………………….10010.7.
SDH Functions > APS est
……………………………………………………………………100
10.7.3…………………………………………………………………………………………….10210.8.
SDH Functions > Tandem Connection Monitoring (TCM) ….10210.9.
SDH Functions > Tributary Scan
…………………………………………………………….102
11.
1………………………………………………………………………………………………10411.1.
PDH Functions > E1 / E3 Pulse Mask
……………………………………………………..104
11.1.1…………………………………………………………………………………………….10511.3.
PDH Functions > E1 APS est ( )
……………………………………..10511.4. PDH Functions
> E1 Frame
Words………………………………………………………….10511.4.1
………………………………………………………………………………………………..10612.
…………………………………………………………………………………………………..10713.
…………………………………………………………………………………………10813.1.
……………………………………………………………………………….10813.2.
…………………………………………………………………………………………..108
13.2.1…………………………………………………………………………………………….10813.3.
………………………………………………………………………………………………..10813.4.
……………………………………………………………………………………………..10913.5.
…………………………………………………………………………………………..10913.6.
……………………………………………………………………………………………10914.
………………………………………………………..11015.
…………………………………………………………………………………………..112…………………………………………………………………………..112
……………………………………………………………………………………………..112
…………………………………………………………………………………………..112
……………………………………………………………………………..113
……………………………………………………………………………………..113SDH
…………………………………………………………………………………………………………..113 -
41. ,
, , — . — , — BERcut-SDH, — , , , .
, , , . — . . — web-, — .
(c) Copyright 2006-2009 METROTEK. .
-
52.
BERcut-SDH. , —
. , — , — , PDH SDH. — web- METROTEKwww.metrotek.ru.
— , email . -. , , — .
:: + 8 495 961 00 71Email: [email protected]:
www.metrotek.ru -
63.
. , — , , , -. , . METROTEK — , — .
BERcut-SDH —
, , — . :
1. — .
2. SFP , . — SFP, , — 1- , , .
3. — , .
. —
, — .
-
74. 4.1.
PDH/SDH. , , . , . -, , . — , ( ). , , .
-. , . , 10 , .
4.2. :
4.2.1 Home. —
. Print.
. USB .
-
8 , , METROTEK.
Store. — . , . — — . , , -, .
History. — (LED) . LED, , LED.
Help. , -.
Arrow. — (, , , ). — Enter Escape.
Enter. . , .
Escape. — . — .
4.3. (LCD) —
. — , , . — , , .. , — . LCD , — , . -. -. , :
, ;
, , ., ;
. .
4.4. — —
, .
-
9 , — . — , . , — . , , . .
-
10
5. , —
: 10/100 T, USB 2.0 — USB 2.0. — .
. -, , METROTEK.
5.1. BERcut-SDH —
.
5.1.15.2. RJ48
— TX RX E1 T1 -. 120 E1 100 T1.
5.3. BNC- 75- TX RX E1, E3, DS3, E4
STM-1E .5.4. SFP
— (TX/RX), — (MSA). — SFP -. . SFP LC .
-
11
, ( — UPC) , . — SFP, , -, , SDH . , SFP — . ROHS — , — SFP
.5.5. SMA- NRZ 2,048
/ 2,048 . 1,544 / 1,544 TX, T1 .
5.6. LED BERcut-SDH
(LED) LED .
5.6.1LED Power . LED ,
. LED , — . LED , — . — , — . — . — 6-7 , , -.
LED Signal , — PDH SDH . LED , — . LED , PDH SDH .
LED Frame , PDH SDH — . LED -, , , .
LED Pattern , -. LED , , , .
-
12
LED ALM/ERR . LED , — . LED , , -. . — LED , , -/, — (O ->
O). -
13
6.
6.1 —
Home . ,
. , —
BERcut-SDH, LAN .
— , . , , — .
-
14
7. —
. — .
7.1 —
PDH, SDH T-. , .
7.1.
-. TX RX , — , — . , — . , . , LED , .
— TX RX, -. TX RX .
, — .
TX RX -, -. , TX — (PRBS)
-
15
223-1 VC-12, STM-4, RX PRBS 223-1 PDH 2M/.
HIERARCHY PDH SDH , , .
INTERFACE — . SDH, SDH (STM-1) PDH . — .
STRUCTURE SDH — .
PAYLOAD SDH PDH ( -) .
PATTERN SDH PDH -. — (PRBS), -T, 24- . .
,
. , .
7.1.1
-
16
7.2. PDH7.2.1. TX Set > Hierarchy
Hierarchy, TX. , , 2M E1. .
7.2.1.1NETWORK TYPE: PDH .HIGH RATE: 2, 34 45 /.
7.2.2. TX Set > Interface Interface, —
TX, .
7.2..2.1
-
17
ES PORT: PDH .
LINE CODE:- E1 HDB3
AMI. E1 HDB3, AMI .
— E3 HDB3.- E4 CMI.- DS1 B3ZS
AMI.- DS3 B3ZS.CLOCK SOURCE: :- Internal clock:
. 3.5 , G.812.
— External clock: 2/ 2 , SMA.
— From RX: -, .
— Offset: , Internal. , 25,000 .
BALANCED: RJ45. — 120. , , — 75- BNC TX.
7.2.3. TX Set > Payload Payload, —
TX.
-
18
7.2.3.1RATE: 2M 2M N x 64, :- 2M:
2,048 /;- N x 64:
N M 64 / ( ).
E3 (34 /) 34M. E4 (140 /) 140M. DS1 (1.544 /) 1.544M. DS3 (45 /)
45M.FRAMING: E1 , PCM31,PCM31C, PCM30 PCM30C. — G.704 G.706 :
— : (FAS) (MFAS);
— PCM31: (FAS) ;- PCM31C: (FAS)
CRC-4 ;- PCM30: (FAS)
(MFAS)- PCM30C: (FAS)
(FAS) CRC-4 .
E3 G.751 (PCM480).
-
19
E4 G.751 (PCM1920).
DS1 , D4 (SF) ANSI T1.107 (ESF).
DS3 , M13 C-Parity. Nx64, :
7.2.3.2FRAMING: PCM31, PCM31C, PCM30 PCM30C
G.704 G.706, E1, .
: n x 64, , — .
UNUSED: () — (AIS), .
TIMESLOT SELECTION: , . , -.
: 1-31 1-31, — PCM-31. — PCM-30 1-15 1-15, 17-31 16-30. — 16
.7.2.4. TX Set > Pattern Pattern, —
TX, . — PDH SDH, -T
-
20
, .
7.2.4.1PATTERN: Pattern
, . — (PRBS), -T 0.150 0.151, 24- .
INVERT: PRBS. — .
. 0.150 -T — :
PDH — 0.150 -T
PRBS
29 1 8 14,400 /211 1 10
n64 / & 64 /215 1 15
1, 1, 3 DS3220 1 14
1, 1, 3 DS3223 1 23 3
4231 1 31 3, DS3 4
-
21
7.3. PDH7.3.1. RX Set > Hierarchy
Hierarchy, RX.
7.3.1.1NETWORK TYPE: PDH .HIGH RATE: 2, 34 45 /.
7.3.2. RX Set > Interface Interface,
RX, .
7.3.2.1ES PORT: PDH,
.
-
22
TERMINATION: (PMP) -. :
— Terminated: 75 120- , . , .e. — 120 .
— Monitor: , (PMP) . PMP 20 26 . BERcut-SDH — -T G.772 ,
PMP.— Bridge: E1. — E1 . E1 .
LINE CODE: — RX , TX. RX, , TX.
7.3.3. RX Set > Payload Payload, —
RX.
7.3.3.1RATE: , , .FRAMING: , , . Nx64, —
:
-
23
7.3.3.2FRAMING: , , .. —
, , — .
UNUSED: () — (AIS), .
TIMESLOT SELECTION: , , .
7.3.4. RX Set > Pattern Pattern, —
RX, .
7.3.4.1
-
24
OUT OF SERVICE: , , . , , — , — — (LSS).
PATTERN: , , .INVERT: , , .
7.4. SDH
SDH. — TX RX .7.4.1. TX Set > Hierarchy
Hierarchy, TX:
7.4.1.1NETWORK TYPE: —
SDH.TEST RATE: 155M, 622M 2.5G ( TM-
1, STM-4 STM-16 ).MAPPING: AU-4 AU-3
G.707. , VC-4-64C TX300.
-
25
7.4.1.27.4.2. TX Set > Interface
Interface TX, . , .
-
26
7.4.2.1S PORT: :- STM-1, STM-4 STM-
16;- STM-1.CLOCK SOURCE: , —
PDH, .7.4.3. TX Set > Structure
Structure TX, TX.
7.4.3.1VC MAPPING: VC12 VC3.
-
27
BULK: . VC — -T 0.181.
TRIBUTARY: 2M Bulk -.
CHANNEL SELECTION: TX, STM-N, TUG-3, TUG-2 TU-12 .
.- TUG: ,
. , , TUG-2 3TU-12, TUG-3 7TUG-2.
— TU-12: TU-12 36 , 4 9 . 8000 2.304 / — 2.048 /. 63TU-12s STM-1
VC-4., , -T G.707.
C, B, A — :
— C: AUG-4 1 4;- B: AUG-1 1 4;- A: AU-3 1 3. SDH :- STM-16: [C,
B, A];- STM-4: [B, A];- STM-1 AU-3: [A]- STM-1 AU-4: [0]. K, L, M
—:- K: TUG-3 1 3;- L: TUG-2 1 7;- M: TU-11, TU12 TUG-2 1 4.
7.4.4. TX Set > Payload Payload TX,
TX.
-
28
7.4.4.1RATE: 2M 34M, VC,
.FRAMING: :- 2M (E1)
PCM30, PCM31, PCM30C PCM31C. . — .
— 34M (E3) — G.751.
7.4.5. TX Set > Pattern Pattern TX,
TX.
7.4.5.1
-
29
PATTERN: Pattern, — , . (PRBS), -T 0.181, 24- .
INVERT: PRBS. — .
. SDH — — -T G.707. (TSS) — -T 0.181 (Out of Service — OOS) —
SDH. TSS PRBS .(TSS) -T 0.181 PRBS SDHTSS1 223 1 C4 ,
(HP)TSS2 215 1 C3 ,
(HP)TSS3 223 1 C3 ,
(LP)TSS4 215 1 C12 ,
(LP)TSS5 223 1 PDH, 4TSS6 215 1 PDH, 3;
(HP)TSS7 223 1 PDH, 3;
(LP)TSS8 215 1 PDH, 12;
(LP)TSS9 223 1 4-4 —
4-16TSS10 215 1 2-4 —
4-167.5. SDH
7.5.1. RX Set > Hierarchy Hierarchy,
RX. RX , TX, .
-
30
7.5.1.17.5.2. RX Set > Interface
Interface, RX. RX , TX, , , .
7.5.2.1. , ,
SFP, . SFP TX RX 1550 , , SFP.
-
31
7.5.2.1 STM-1/4(155/622 /) STM-1/4/16 (155/622/2468 /)
A1310-IR A-1310-LR A-1550-LR B-1310-IR B-1310-LR B1550-LR
-, ,,/
131015
622LC
NRZ
131040
622LC
NRZ
155080
622LC
NRZ
131015
2488LC
NRZ
131040
2488LC
NRZ
155080
2488LC
NRZ
,, ,
Fabry Perot12741356
2.5-15-8
DFB12801335
1-3+2
DFB14801580
1-3+2
DFB12701360
1-50
DFB1280335
1-2+3
DFB15001580
1-2+3
—,: 155/ 622/ 2488/ ,
PIN
-28-8-28-8
N/A12601600
PIN
-28-8-28-8
N/A12601600
PIN
-28 to-8-28 to-8
N/A12601600
PIN
-23-10-220-180
12701600
APD
-30-15 -29-9-27-9
12701600
APD
-30-15-29-9-28-9
12701600
-
32
7.5.3. RX Set > Structure Structure,
RX. RX , TX, .
7.5.3.17.5.4. RX Set > Payload
Payload, — RX. RX , TX, .
7.5.4.17.5.5. RX Set > Pattern
Pattern, — RX. — RX , TX, , — Out of Service, , ,
-
33
. — , , .
7.5.5.17.6.
Measurements, — , .
7.6.17.6.1.
. MODE: , — .
— Manual: Start/Stop .
-
34
— Timed: . , , . Start /Stop .
— Auto: . , , . Start , , .
. , — M.2100 M.2101.
7.6.2. —
-T, . (None), G.821, G.826, G.828, G.829, M.2100 M.2101. .
7.6.2.1
— G.821: , (ISDN).
(OOS) ;
, ; 30 ; ,
.- G.826: —
. —
(OOS) ;
-
35
, ;
30 .- G.828 : —
. SDH; —
(OOS) , ;
30 .- G.829 :
SDH. SDH; ; , .
— M.2100: PDH.
, PDH; , ; (BIS)
(OOS) (ISM); 15 , 2 24 ; 15- ; PDH,
(RPO).- M.2101. : —
SDH. , SDH; , ; (BIS)
(OOS) (ISM); 15 , 2 24 ; 15- .
. . M.2100 M.2101 -. , — .
7.6.2.1 PDH SDH
G.B21 TSE, —
-
36
3.826 ( -)
TSE,
3.826 (-)
B1, B2, B3, LP-BIP, E1 /E3/E4 FAS,E1 CRC
3.828 (-)
B1, B2, TSE
G.329 (-)
B1, B2, B3, LP-BIP, TSE
M.2100 E1/E3/E4 FAS, E1 CRC, TSEM.2101 B1, B2, B3 HP, LP-BIP,
TSE7.6.3. General —
APS .
7.6.3.1- Audible Alarm: On Off.
.- APS Protocol: .
, (K1/K2) — (APS) SDH — SDH. , APS.
-
37
7.6.4. .
7.6.4.1 Auto-Config BERcut-
SDH. SDH PDH — , . — -, (PMP).
Procedure Start, .
, , -, . -, PASS ( ).
— : ( /
).- Mapping: , —
. 1. 2.5G(STM-16) AU-4.
— Payload: , -T ANSI. -, .
PDH signals: s . 2M, 64 /,BERcut-SDH — .
-
38
8. , —
Results . , .
8.18.1. PDH
8.1.1. Results > Summary Summary .
, -, . — ( ).
8.1.1.1
-
39
8.1.2. Results > Error/Alarm ( 1) Error/Alarm , —
. 1 4 , . , , / .
, , . , :
— : ;- : —
;- : .
, — .
8.1.2.1. ,
, .
Results > Error/Alarm ( 2) 2 4 ,
, . -. , , 100 .
-
40
8.1.2.2Results > Error/Alarm ( 3) 3 4 , —
, . -.
8.1.2.3Results > Error/Alarm ( 4) 4 4 (BERT), —
.
-
41
8.1.2.48.1.3. Results > Event Log
Event log , . — :
— Number (#): , ;- Type: ;- Start: , ;- Dur/Count: ,
, () (). : :::;
— s: , .
8.1.3.1
-
42
8.1.4. Results > Signal Signal
.
8.1.4.1FREQUENCY: —
. E1 — 120-, 75- .
— Current: ;- Offset: —
;- M ( ): —
, ;- Max ( ):
, ; M ( ) Max ( )
, , . -, .
8.1.4.1 PDH —
E1 PDH 2048 / 112 / (54,6 )E3 PDH 34368 / 846 / (24,6 —
)E4 PDH 139264 / 2730 / (19,6
)DS1 T- 1544 / 57 / (36,6 )DS3 T- 44736 / 1101 / (24,6 —
-
43
)
LEVEL: . — -, .
8.1.4.2 PDH — G.703
—
1 2/
HDB3 75 -BNC120 -RJ45
: — 2,37: 2,37: — 3,0: 3,0 c 20 26
3 34/
HDB3 75 -BNC
: — 1,0: 1,0 c 20 26
4 140/
CMI 75 -BNC
: — 1,0: 1,0 c 20 26
8.1.5. Results > Analysis -, :-T G-: ,
, ;-T M-: —
(BIS) .
— .8.1.6. Results > Histograms
Histograms , — , . , BER. , — .
-
44
8.1.6.1 —
. -, . — , + -. , , -.
8.1.6.1 1
LOS AIS LOF LOMF PDI
E1.
-
45
8.1.6.2 8.1.6.2 1
CODE (HBD3, AMI)FAS CRC REI
BER .
8.1.6.3 8.1.6.3BERT
LSS Bit
-
46
8.1.7. Results > Bar Bar ,
, . . , .
8.1.7.1 ,
, . — , + .
e, . , -. .
-
47
8.1.7.28.2. SDH
8.2.1. Results > Summary Summary —
. , — , -, SDH . ( ).
8.2.1.18.2.2. Results > Errors/Alarms ( 1)
Errors/Alarms , — .
1 , . — , , / .
, , . , :
— : ;- : —
;- : .
, .
-
48
8.2.2.1. ,
, .
(LED) . 8.2.2.1
SDHRS MS AU HP TU LP E1 2 / ( )Pat (PRBS, , —
)
-TG.707 0.150.
8.2.2.2 BER
LOS LOS , (STM-N) , BER 1-3. — , — . LOS ,
TSE
-
49
LSS — PRBS , , — , , — . , -, :1) > 0,20 —
— LOF
, OOF 3 . OOF , — , OOF , SDH () -. OOF B1 , B1 byte(BIP-8)
STM-N. , — —MS-AIS , 6,7,8 K2 «111» MS-RDI , 6,7,8 K2 «110» MS-REI STM-1 ,
M1, — TS #3, STM-4/16 , M1, — TS #7, B2 , B2 (BIP-24x N) STM-N. N x
24 — ,— AU-AIS
, H1 H2
AU-LOP , N — , N = 8, 9 10, — 1001 (NDF)AU-
NDF
(HO) —
-
50
HP-UNEQ
HO, C2 «00H» — HP-RDI , 5, 6, 7 G1 — 100 111
HP-TIM (TIM) , J1 . , TIMHP-PLM ,
B3 C VC-3, VC-4 , B3 byte(BIP-8) VC-N (N = 3, 4). , -HP-RE1 ,
1-4 G1 — 0001 1000TU-AIS
, V1 V2 000
TU-LOP , N (N >6
-
51
PDH .Results > Errors/Alarms ( 2) 2 SDH, —
, . . [ET] . , , .
8.2.2.2Results > Errors/Alarms ( 3) 3 RS MS, —
, . . [ET], , .
8.2.2.3
-
52
, [RS] [MS] , .
Results > Errors/Alarms ( 4) 4 [HP], —
, . .
8.2.2.4Results > Errors/Alarms ( 5) 5 [LP], —
, . .
8.2.2.5Results > Errors/Alarms ( 6)
-
53
6 PDH, — , . -.
8.2.2.6
Results > Errors/Alarms ( 7) 7 PDH,
. -.
8.2.2.78.2.3. Results > Event Log
Event log — , . —
-
54
; , , , , () (). , — .
8.2.3.18.2.4. Results > Signal ( 1)
Signal . 1 ( ) STM-1E ( ) STM-10, STM-40 STM-160.
(LOS) , .
8.2.4.1Results > Frequency ( 2)
-
55
. SDH (BNC) — (SFP) .
8.2.4.2 ,
, -. — , . — , BERcut-SDH — (PMP). , , , — . SDH .
8.2.4.1 SDH
, / , 155520 < 4,6622080 < 4,6
2366320 < 4,6
8.2.5. Results > Histogram ( 1) Histogram , —
. — , BER.
1 , (SOH).
-
56
8.2.5.1. —
. -, . — , — + .
Results > Histogram ( 2) 2 , (SOH).
8.2.5.2Results > Histogram ( 3) 3 , —
(AU). :- AU-AIS (AU );- AU-LOP (AU ).
-
57
8.2.5.3Results > Histogram ( 4) 4 ,
(HP). :- HP-UNE (HP );- HP-PLM (HP );- HP-TIM (HP );- HP-RDI (HP
);- B3 ;- HP-REI (HP ).8.2.5.4Results > Histogram ( 5) 5 ,
(TU). ;- TU-LOM (TU );
-
58
— TU-AIS (TU );- TU-LOP (TU ).
8.2.5.5Results > Histogram ( 6) 6 ,
(LP). :- LP-UNE (LP );- LP-PLM (LP );- LP-TIM (LP );- LP-RDI (LP
);- LP-RFI (LP );- LP-BIP (LP );- LP-REI (LP )8.2.5.6Results > Histogram ( 7)
-
59
7 , . .
8.2.5.7Results > Histogram ( 8 , . —
.
8.2.5.8Results > Histogram ( 9) 9 , —
.
-
60
8.2.5.98.2.6. Results > Graph Bar
Bar , — , . — :
— FAS;- B1;- B2;- MS-REI;- B3;- HP-REI;- LP-BIP;- LP-REI;- PDH,
. , —. , .
-
61
8.2.6.18.2.7.
-T G.821
n x 64 / — .
ES, SES, AS UAS :- FAS (FAS 2, FAS 34, FAS 140);- CRC;- E;- ( —
TSE). ,G.821 (TSE):- ;- n x 64 /;- ;- E1, E2, F1, F2, D1-D3 D4-D12;- /
—0,1 100%.. -T G.821 ,
, . G.821 , — .
: (ES): ,
. (SES):
, 10-3.
-
62
(UAS): SES. , (SES).
(AS): , — .
8.2.7.1 -T G.826 G.826
, .
: ES, SES, BE, BBE UAS. / —
0,1 100%. (ISM)
. (OOS) ,
.: (ES): ,
. (SES):
, 30 % . (BE): . (BBE): ,
SES.
-
63
(UAS): SES. , (SES).
. G.821 G.826 30 .
8.2.7.2 -T G.828G.828 —
G.826.- ES, SES, BBE, UAS SEP.- / —
0,1 100%. G.828 :- B1;- B2;- MS-REI;- B3;- HP-REI;- LP-BIP;-
LP-REI;- (TSE). ,, REI. :- ;- ;- E1/E2 (), F1/F2 ( ), D1-D3
D4-D12 (DCC) SDH (SOH POH).. , G.828 —
.
-
64
8.2.7.3 -T G.829G.829 —
. ES, SES, BBE UAS. G.829 :- B1;- B2;- MS-REI;- (TSE). ,
, REI. :- ;- ;- E1/E2 (), F1/F2 ( ), D1-D3
D4-D12 (DCC) SDH (SOH POH).
-
65
8.2.7.4 -T M.2100M.2100 —
. 15- 24- . , — .
ES, SES UAS. / —
S1 S2 ES SES. S1 S2:- : 0,1 100 %;- (BISO): 0,1
100. M.2100 :- FAS (FAS2, FAS34, FAS140);- CRC-4;- EBIT;- (TSE).
—PCM-30/31 CRC. :- ;- ;- n x 64 /;- E1, E2, F1, F2, D1-D3 D4-D12.
M.2100 , —.
-
66
8.2.7.5 -T M.2101 M.2101 M.2100 ,
SDH. ES, SES, BBE, SEP UAS. / —
S1 S2 ES, SES, BBE SEP. S1 S2:- : 0,1 100 %;- (BISO): 0,1
100. M.2101 :- B1;- B2;- MS-REI;- B3;- HP-REI;- LP-BIP;-
LP-REI;- (TSE). ,, REI. :- ;- ;- E1/E2 (), F1/F2 ( ), D1-D3
D4-D12 (DCC) SDH (SOH POH).. M.2101 , —
.
-
67
8.2.7.6
-
68
9. / —
. Alarm/error,
. , . — PDH SDH.
9.19.1.
PDH T-:
PDH:- E1: LOS, LOF, AIS, RDI;- E3: LOS, LOF, AIS, RDI;- E4: LOS,
LOF, AIS, RDI;- DS1: AIS, Yellow, idle, LOS, LOF;- DS3: LOS, LOF,
OOF, AIS, .: (/). SDH:
-
69
9.1.1 SDH:- STM-1/4/16 ( ): LOS, LOF, MS-AIS, MS-
RDI, RS-TIM, AU-LOP, AU-AIS, HP-UNEQ, HP-PLM, HP-RDI, HP-TIM,
TU-LOM, TU-LOP, TU-AIS, LP-UNEQ, LP-PLM, LP-RDI, LP-RFI,
LP-TIM;— ( ):2M-AIS, 2M-LOF, 2M-RDI, 34M-AIS, 34M-LOF, 34M-RDI,
45M-AIS;: (/) .
9.2. SDH, PDH T-:
9.2.1 PDH T-: PDH:
-
70
— E1: Code, FAS, CRC, REI, E-bit, Bit;- E3: Code, FAS, Bit;- E4:
Code, FAS, Bit;- DS1: Code, FAS, Bit;- DS3: Code, FAS, Bit. SDH:
SDH:- STM-1/4/16: FAS, B1, B2, MS-REI, B3, HP-REI, LP-BIP, LP-REI,- : 2M-FAS, 2M-CRC, 2M-REI,
34M-FAS, 45M-FAS, 1.5M-FAS. .
:- Single: ,
;- Count:
, ;- Rate: 110-3 510-6. —
, SDH PDH .
9.2.2Alarm Generation / Error Insertion ( ) —
, .
-
71
9.2.3
-
72
10. SDH SDH . —
SDH Functions, .SDH Functions > Shortcuts
10.1Overhead Analyzer: (SOH)
(POH) .Overhead Generator: —
(SOH) (POH) .Pointer Tasks: AU TU
AU TU. , — -T G.783, .
Trace Identifier: — J0, J1 J2 -, G.831.
Payload Labels: C2 V5, VC .
Overhead BERT: BERT — DCC ( D1-D4 D5-D12), E1 E2 F1.
APS sting: (APS). , — .
TCM Tasks: — N1 N2 TCM — .
-
73
Tributary Scan: — . VC-12.
10.1. SDH Functions > Overhead Analyzer Overhead Analyzer,
OH,. :- SOH RX, , —
(RS MS);- POH RX, , —
;- Summary, (J0, J1, J2), APS (K1,
K2), (S1) HP (C2) LP(V5).
10.1.1 —
, — . — .
SOH
. A1/A2:- A1/A2 STM-1 —
: A1 : 11110110 (Hex F6); A2 : 00101000 (Hex 28);
— A1 A2 ;
-
74
— STM-N (3 x N) A1 — (3 x N) A2
10.1.2 J0 (RS-Trace):- ;- 16 64 ()
( CRC-7), , — ;
— -.
B1 (RS-BIP):- 8-
.- STM-1 —
;- RS
STM-1 .
-
75
10.1.3 E1 ( RS):- ,
, . F1 ( RS):- ;- —
;- .
10.1.4 D1/D2/D3 (RS DCC):- (DCC);- D1, D2 D3 192
/ , (OAM);- ;- BER.
-
76
H1/H2/H3 ( AU):- STM-1 STM-n —
MS.
10.1.5 B2 (MS-BIP):- 24- ,
, -;
— STM-1, — ;
— MSOH STM-1.
10.1.6
-
77
K1 ( APS):- —
;- APS -T G.783
;- 1-4 ( G.783):
1111 ; 1110 ; 1101 , ( 1:n); 1100 , ; 1011 , (
1:n); 1010 , ; 1000 ; 0110 ; 0100 ; 0010 ( —
); 0001 ; 0000 ; ;
— 5-8 , APS: 0000 ; 00011110 1 14; 1111 .
10.1.7 K1 ( APS):
-
78
— — ;
— APS -T G.841 ;
— 1-4 G.841: 1111 ; 1110 (); 1101 (); 1100 (); 1011 (); 1010 ();
1001 (); 1000 (); 0111 (); 0110 (); 0101 ; 0100 (); 0011 (); 0010
(); 0001 (); 0000 ;— 5-8 ID: 0000 ; 00011110 1 14; 1111 .
K2 ( APS):- -T G.783;- —
;-
(AIS) (RDI);- 1-4 ;- 5 APS:
1+1; 1:n;
— 6-8: MS-RDI; MS-AIS;
— . K2 ( APS):- -T G.841;- —
;
-
79
— l(AIS) (RDI);
— 1-4 ID;- 5 — :
— — ;
— 6-8: ; ; ; MS-RDI; MS-AIS;
— .
10.1.8 D4-D12 (MS-DCC)- (DCC) —
576 / , — (OAM);
— BER.
-
80
10.1.9 S1 ( ):-
, , — ;
— 1-4 ;- 5-8:
0000 ; 0010 G.811 PRC; 0100 G.812 ; 1000 G.812 ; 1011 G.813 ;
1111 ;— .
-
81
10.1.10 E2 ( MS):- 64
/;- ,
;- , .
10.1.11 POH
. J1 ( HP):- VC-N ;- ,
SDH ,
-
82
— ;
— 15- (CRC-7), — ;
— 64- ;- VC-4.
10.1.12 B3 (HP BIP):- , ;- VC-
4;- B3 .
10.1.13
-
83
C2 ( HP):- VC-n;- C2.
C2 -T G.7071-4
5-9
— —
0000 0000 00 0000 0001 01 0000 0010 02 TUG0000 0011 03 TU-n0000
0100 04 34 /45 / C30001 0010 12 140
/ C40001 0011 13 ATM0001 0100 14 DQDB ( —
) (AN)0001 0101 15 FDDI (-
)0 001 1000 18 HDLC/LAPS0001 1010 1A 10 Gigabit Ethernet (IEEE
802.3)0001 1011 IB (GFP)0001 1100 1C 10 Gigabit0010 0000 20 —ODU-k1111 0000 FE , —
— 0.1811111 1111 FF VC-AIS (TCM)
-
84
10.1.14 G1 ( HP):- ;- —
, ;
— 1-4: (HP-REI) , B3;
— 5: (HP-RDI), 1, ;
— 6-7: RDI (HP-PLM), (HP-TIM, HP-UNQ) — (HP-AIS, LOP).
F2 ( HP)- ;- VC-4 —
.
-
85
10.1.15 H4 ( TU):- ;- —
. F3 ( LP)- ,
.
10.1.16 K3 (HP APS):- 1-4 VC-3/4.- 5-8 . N1 (HP TCM):
-
86
— — (HP) — VC-4, VC-4 VC-3.
— 1-4: — (IEC) G.707;
— 5: TC-REI , —
— 6: OEI , — VC-n;
— 7-8: 76 . 10.1.1 N1 — G.707
1 2 3 4 5 6 7 8 IEC TC-REI OEI TC-API, TC-RDI,
ODI, —
: 1-8 > (FAS). 9-72 > —
(TC-API). 73-76 > TC-RDI,
. 74 > ODI, —
, — — AU-n/TU-n AU/TU-AIS.
73-76 > .
10.1.17
-
87
V5 ( LP):- , —
;- —
;- 1-2 (BIP-2);- 3 LP-REI (0 = , 1 = );- 4 LP-RFI (0 = , 1 = );-
5-7 VC-12:000 ; 001 ( ); 010 011 — 100 — 101 010 (TSS4), .181; 111
VC-AIS;— 8 LP-RDI, 0, 1 — VC12 (AIS).
10.1.2 V5 — G.707
1 2 3 4 5 6 7 8BIP-2 LP-REI LP-RFI TC-REI LP-RDI
J2 ( LP):- 16- —
, — ;
— , J0 J1.
10.1.18
-
88
N2 (LP TCM):- LP (LP-
TCM) VC-2, VC-11 VC-12.- 1-2: BIP-2
;- 3: 1;- 4: AIS (0 = ; 1 = —
);- 5: TC-REI, —
;- 6: OEI VC-n ;- 7-8: 76 . 10.1.3 N2 — G.707
1 2 3 4 5 6 7 8BIP-2 1 I-AIS TC-REI OEI TC-API, TC-RDI,
ODI, —
: 1-8 > (FAS). 9-72 > —
(TC-API). 73-76 > TC-RDI,
. 74 > ODI, —
, — — AU-n/TU-n AU/TU-AIS.
73-76 > .
-
89
10.1.19 K4 ( LPl):- 5-7 V5 101 ( = 5),
K4 , : 32- ; 1 ; 2 ; 3 4 LP
APS; 5, 6, 7 ; 8 ; 12-19 32- , —
. 10.1.2
K4 — G.7071 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
22 23 24 25 26 27 28 29 30 31—
0 R R R R R R R R R R R
10.1.3 K4 — G.707
1 2 3 4 5 6 7 8 —
—
Summary
-
90
Summary , SDH:
— Column #1 — ;- Column #2 ( —
);- Column #3 (,
)..- (SP) —
;- , —
. C2 PLM( ), .e. — .
10.1.20
-
91
10.2. SDH Functions > Overhead Generator
10.2.1 Overhead Generator,
OH, . :- SOH TX, , —
. J0, K1, K2, S1:
; —
; . —
.. —
OH; — , , — , APS, TCM BERT. .
-
92
10.2.2- POH TX, , —
. J1, C2,H4, G1, K3, J2, V5 K4:
; —
; . —
.. —
OH; — , , — , APS, TCM BERT. .
-
93
10.2.3- Summary, (J0, J1,
J2), APS (K1, K2), (S1), HP(C2) LP (V5). , Overhead
Analyzer.10.3. SDH Functions > Pointer Tasks Pointer Tasks, —
.
10.3.1 .- SDH —
. — , . (AU)
-
94
(TU) , — :
AU:- SS 5 6 H1 SDH [10],
SONET [00], [01] [11];- H1 H2 () —
AU-n;- LOP ( );- PJE NJE;- NDF ( ). NDF , 3
4 1001, , 3 0110;
— ; TU:- ;- LOP ( );- PJE NJE;- NDF ( );- .
10.3.2- Generator —
: AU:- SS: 5 6 H1,
SDH [10], SONET [00] [01] [11];- : —
NDF ( ) . AU-3/4 0 782;
-
95
— (INC) (DEC) — ;
TU:- : 0 784 (TU-3)
0 139 (TU-12);- (INC) (DEC) —
.
10.3.3- G.783 Sequences ( )
. -T G.783:- 87-3: 87
, -;
— 43-44: 43 , — 44 — , , ;
— 86-4: 86 , -.
-
96
10.3.4.1.
, — . — , , .
2. , 30- .
10.4. SDH Functions > Trace Identifier Trace Identifier,
—, . () .
10.4.1 (TX)- J0 [RS]: e : 1 16 —
;- J1 [HP]: :
-
97
16 64 ;
VC-4;- J2 [LP]: : 16 64
..
Trace, — QWERTY.
10.4.2 (RX)- J0 [RS]: e : 1 16
; TIM ( —
);- J1 [HP]: : 16 64
; TIM ( —
);- J2 [LP]: : 16 64
; TIM ( —
);.
Trace, — QWERTY.
-
98
10.4.310.5. SDH Functions > Payload Labels
C2 V5, VC -.
10.5.1 Payload Label,
. — .
C2 [HP]: VC-n;
-
99
TX RX ;
RX PLM ( ).
10.5.2- V5 [LP]: TX RX
;
RX PLM ( ).
10.5.3
-
100
10.6. SDH Functions > Overhead BERT . —
BERT DCC ( D1-D4 D5-D12), — E1 E2 F1.
10.6.110.7. SDH Functions > APS est
— (APS) . APS — SDH . — K1 K2 .
10.7.1 APS SDH
-T G.783 G.841 —
-
101
. , 50 . — :
— (SF) (LOS), MS-AIS, BER>1 x 103;
— (SD) , BER . , 10 5 109.
:1. BERcut-SDH —
, — SDH.
2. , , .
3. , — (AIS) (TSE) 10 4.
4. BERcut-SDH , — AIS TSE , , — .
AIS BER > 2 10-4
AIS BER > 2 10-4
APS 200
APS 200
APS 400
APS 400
10.7.2 APS est,
APS, . :- Sensor: ,
APS. MS-AIS, AU-AIS, TU-AIS TSE ( ).- Switch Time Limit: 50 200
, 50-.
-
102
— Gate Time: 500 4 . , .
— Start: , .
10.7.310.8. SDH Functions > Tandem Connection Monitoring
(TCM).
10.8.110.9. SDH Functions > Tributary Scan
VC12 — , .
-
103
10.9.1
/ (ADM) . -, , STM-1 63 VC-12, aSTM-4 252 VC-12 , .
BERcut-SDH BER SDH ( C12) AU-4, AU-3. , SDH, — . :
— K.L.M.: -T;- : (OK);- J2: , LP;- : V5.
-
104
11. PDH PDH . —
PDH Functions, , .
11. 111.1. PDH Functions > E1 / E3 Pulse Mask
E1(2,048 M/) E3 (34,368 M/). , : , — .
— , -T G.703. — . , , -. -, .e. , . E1, BERcut-SDH — 120 — 75 .
, 75 120 — , : — 75- 2,37 10%, — 120- 3,0 10%.G.703 E1 , — , , , , — c . BERcut-SDH, , — TX (PMP) —
-
105
. , .
11.1.111.3. PDH Functions > E1 APS est ( )
.11.4. PDH Functions > E1 Frame Words
, E1 . NFAS o p -.
11.4.1, (NFAS)
1 2 3 4 5 6 7 8Si (M) 1 A Sa4 Sa5 Sa6 Sa7 Sa8
— 1: (M — CRC PCM30C PCM31C).
— 2: 1 FAS.- 3: .- 4 8: Sa4 Sa8 .TX: Sa4 Sa8 —
. Sa 1, — .
RX: Sa4 , , .
-
106
11.4.1
-
107
12. , —
‘Profiles’. PDH SDH — . Profiles, .
12.1 PDH SDH, —
, Save as New. — . -, , — (PDH SDH). — .
-
108
13. 13.1.
, .
13.1.113.2.
, .
13.2.1
13.3. , .
-
109
13.4. , .
13.4.113.5.
, .13.6.
, .
-
110
14. : , —
. — , LCD, , LCD ( , ,SFP, USB, ) (1) .
: METROTEK , — . METROTEK, , —
, ,
, , , METROTEK — (30) .
: METROTEK , . — METROTEK, ,
/ , —
, , , , METROTEK — (30) .
, METROTEK -, , , — -. METROTEK , — . , — , ( ) , .
: , (, / ).
: METROTEK , o, -. :
; —
() METROTEK; ; , —
, ;
-
111
.
-
112
15.
RJ-48 (120 ) : 1,544 /, AMI B8ZS () 2,048 /, H3 AMI BNC (75 ) :
2,048 /, H3 & AMI 34,368 /, H3 44,736 /, B3ZS () 139,264 /, CMI
() 155,520 /, CMI () ITU-T G.703, G.823, G.824, G.825, G.772 ANSI
T1.102 ITU-T G.703 : 2.048 / (E1); : 6 ( ) (PMP): 26 (20 , 6 ) : 6
( ) 34,368 / (E3); : 12 ( ) (PMP): 26 (20 , 6 )1.544 / (DS1); : 6 ( ) (PMP): 26 (20 , 6 ) : 6 ( ) 44,736 /
(DS3); Terminate: 6 ( ) Monitor (PMP): 26 (20 , 6 ) 139,264 / (E4)
155,520 / (STM-1E); : 12.7 ( ) (PMP): 26 (20 , 6 )l: 2,048/, 3.5 ppm stability per ITU-T G.812 : 2,048 / SMA :
2,048 ( TTL) : 2,048 / (H3) Tx: -
113
25,000 ppm 0.1 ppm —
Small Form Factor Pluggable (SFP)
Multi Source Agreement (MSA) ROHS compliant and Lead Free per
Directive 2002/95/EC : -10C to 70C : Class 1, FDA/CDRH, EN (IEC)
60825 EN (IEC) 60950 ITU-T G.957 SDH : 2, 1SDH
SOH
STM-1 ( VC-n); PDH (
ITU-T 0.150) STM-4 ( VC-n); PDH (
ITU-T 0.150) Bulk TSS (per ITU-T 0.181) STM-16 ( VC-n); PDH
(ITU-T 0.150) Bulk TSS (per ITU-T 0.181) ( ITU-T G.707) C-12 (
E1,-) C-3 ( E3 DS3)
AU-3 AU-4 C-4 (E4) C-4-4c (STM-4 STM-16) C-4-16c (STM-16)
-
114
C-11 ( DS1)
PRBS: 211-1, 215-1, 220-1, 223-1, 231-1: —
: 0000, 1111, 1010, 1000 1100 : 24
O : FAS, B1, B2, MS-REI, B3, HP-REI, LP-REI, LP-BIP, slips : (1
x 10-3 5 x 10-6) : FAS, B1, B2, MS-REI, B3, HP-REI, LP-BIP,
LP-REI,: LOS, LOF, MS-AIS, MS-RDI, RS-TIM, AU-LOP, AU-AIS, HP-UNEQ,
HP-PLM, HP-RDI, HP-TIM, TU-LOM, TU-LOP, TU-AIS, LP-UNEQ, LP-PLM,
LP-RDI, LP-RFI, LP-TIM, 2M AIS, 2M LOF, 2M RDI : (/) : LOS, LOF,
OOF, RS-TIM, MS-AIS, MS-RDI, AU-AIS, AU-LOP,HPUNEQ, HP-PLM, HP-TIM, HP-RDI, TU-LOM, TU-AIS, TU-LOP, LPUNEQ,
LP-PLM, LP-TIM, LP-RDI, LP-RFI/, —
, — ITU-T G.707, G.703, 0.151 0.181
( G.783) ( G.841) — SOH/POH
, ASCII S1 C2 HP J0 (16 ) ASCII J1 (16 64 ) ASCII J2 (16 64 )
ASCII K1, K2 APS V5 LP RSOH: -
115
J0 : 1 16 — ASCII CRC-7
MSOH: K1, K2 APS ITU-T G.783 G.841 S1 HO-POH (VC-4, VC-3): J1 :
16 ASCII CRC-7 64ASCII C2 H4 / G1 ( 5) — ( RDI) K3 ( 1-4) APS LO-POH (VC-3): J1 :
16 ASCII CRC-7 64ASCII C2 G1 ( 5) — ( RDI) K3 (1-4) APS LO-POH (VC-12, VC-11): V5
( 5-7) LP J2 : 16 ASCII CRC-7 64ASCII K4 ( 3-4) LP APS
BERT : PRBS DCC ( D1-D3 D4-D12)
E1, E2, F1, N1 N2 PRBS: 223 -1, 220 -1, 215 -1, 211 -1 ( —
) ,
, , —
, , New Data Flags (NDF) (ppm AU/TU)
, ,
/ VC-12 ,
BER
-
116
PDH
( E1) ( E1, DS1 )
2,048 / (E1) / CRC ITU-T G.704 (PCM30, PCM30C, PCM31, PCM31C)
N/M x 64 / N=1-30 34,368 / (E3) ITU-T G.751 1,544 / (DS1) SF (D4),
ESF ANSITelcordia N x 64 /, N x 56 / N=1-24 44,736 / (DS3) M13 C-Bit
ParityITU-T G.752 ITU-T G.704 139,264 / (E4) ITU-T G.751
:
PRBS: 211-1, 215-1, 220-1, 223-1, 231-1: : 0000, 1111, 1010,
1000 and 1100 : 24:
2,048 / (E1): Code, FAS, CRC, EBIT, 34,368 / (E3): Code, FAS, 2M
FAS, 2M, ( 1 x 10-3 5 x 10-6) 1,544 / (DS1): Code, FAS, Bit, Frame,
CRC 44,736 / (DS3): Code, FAS, MFAS, P/C-Parity, 139,264 / (E4):
Code, FAS,: 2,048 / (E1): Code, FAS, CRC, E-BIT 34,368 / (E3): Code, FAS,
(DS1, DS3 and E4) Code, FAS, MFAS, 2M CRC, P/C-Parity, -
117
: 2,048 / (E1): LOS, AIS, LOF, RDI 34,368 / (E3): LOS, AIS, LOF,
RDI, 2M LOF, 2M RDI : (/)1,544 / (DS1): AIS, , idle, LOS, LOF 44,736 / (DS3): LOS, LOF,
OOF, AIS, Parity 139,264 / (E4): AIS, FAS RDI: 2,048 / (E1): LOS, AIS, LOF, LOMF, RDI LSS 34,368 / (E3): LOS,
AIS, LOF, RDI LSS (T-Carrier DS1/DS3) LOS, AIS, LOF, OOF, IDLE,
YELLOW LSS, ES, %ES, SES, %SES, UAS, %UAS, EFS, %EFS,AS, %AS, : , :
ITU-T G.821: ES, EFS, SES, DM, UAS HRP 1% 100%
ITU-T G.826: EB, BBE, ES, EFS, SES, UAS. HRP 1% 100%.
(ISM) B1, B2, B3, FAS, CRC Code (E1).
(OOS) (TSE) ITU-T G.828: ES, EFS, SES, BBE, SEP, UAS HRP 1%
100% ITU-T G.829: ES, EFS, SES, BBE, UAS RSOH (B1),
MSOH (B2) TSE ITU-T M.2100: ES, EFS, SES, UAS HRP 1% 100%.
(MTCE)(BIS). ITU-T M.2101: ES, EFS, SES, BBE, SEP, UAS HRP
1% 100%. (MTCE)
(BIS). TSE, HP-BIP (B3), MS-BIP (B2),
RS-BIP (B1) LP-BIP (V5)
: , —
, ,
-
118
: / ppm : 1Hz TIE
: : 1. 10 : 1 1 U.I.
: , ,
, , —
/ SDH/PDH / —
SDH/PDH PDH
: 2,048 / (E1) 34,368 / (E3) : : : , —
, : G.703 T-Carrier : 1,544 / (DS1) 44,736 / (DS3) C: G.703,
ANSI T1.102, T1.403, T1.404(APS) SDH PDH : PDH (E1), SDH : 1 10 : 1 : MS-AIS, AU-AIS,
TU-AIS, B2 APS (K1/K2) — LOS, LOF, AIS, TSE : , , -
119
ITU-T G.783
TANDEM CONNECTION MONITORING (TCM) N1 N2 : TC-IEC, TC-BIP,
TC-REI, OEI : TC-RDI, TC-UNEQ, TC-LTC, TC-AIS, TC-ODI , , : TC-IEC,
TC-AIS, TC-REI, TC-RDI, TC-OEI, TC-LTC, TC-UNEQ, TC-ODI, TC-TIM
APId (Access Point Identifier)210 x 100 x 55 ( x x ) 1. Li-Ion > 3 AC : 100-240 AC, 50-60
Hz15 DC, 3.5A -10C to 50C : -20C to 70C 5% 95% : 3.5QVGA 320×240 :
1m2. 3. 4. 4.1. 4.2. 4.3. 4.4.
5. 5.1. 5.1.15.2. RJ485.3. BNC5.4. SFP5.5. SMA5.6. LED
6. 7. 7.1. 7.2. PDH7.2.1. TX Set > Hierarchy7.2.2. TX Set
> Interface7.2.3. TX Set > Payload7.2.4. TX Set >
Pattern7.3. PDH7.3.1. RX Set > Hierarchy7.3.2. RX Set >
Interface7.3.3. RX Set > Payload7.3.4. RX Set > Pattern7.4. SDH7.4.1. TX Set > Hierarchy7.4.2. TX Set >
Interface7.4.3. TX Set > Structure7.4.4. TX Set >
Payload7.4.5. TX Set > Pattern7.5. SDH7.5.1. RX Set > Hierarchy7.5.2. RX Set >
Interface7.5.3. RX Set > Structure7.5.4. RX Set >
Payload7.5.5. RX Set > Pattern7.6. 7.6.1. 7.6.2. 7.6.3. 7.6.4.
8. 8.1. PDH8.1.1. Results > Summary8.1.2. Results >
Error/Alarm ( 1)8.1.3. Results > Event Log8.1.4. Results >
Signal8.1.5. Results > Analysis8.1.6. Results >
Histograms8.1.7. Results > Bar8.2. SDH8.2.1. Results > Summary8.2.2. Results >
Errors/Alarms ( 1)8.2.3. Results > Event Log8.2.4. Results >
Signal ( 1)8.2.5. Results > Histogram ( 1)8.2.6. Results >
Graph Bar8.2.7.9. /9.1. 9.2.
10. SDH10.1. SDH Functions > Overhead Analyzer 10.1.2010.2.
SDH Functions > Overhead Generator10.3. SDH Functions >
Pointer Tasks10.4. SDH Functions > Trace Identifier 10.4.310.5.
SDH Functions > Payload Labels 10.5.310.6. SDH Functions >
Overhead BERT10.7. SDH Functions > APS est 10.7.310.8. SDH
Functions > Tandem Connection Monitoring (TCM) 10.9. SDH
Functions > Tributary Scan 11. 111.1. PDH Functions > E1 / E3
Pulse Mask 11.1.111.3. PDH Functions > E1 APS est ( )11.4. PDH
Functions > E1 Frame Words11.4.113. 13.1. 13.2. 13.2.113.3. 13.4. 13.5. 13.6.
14. 15. SDH
SDH Topologies — · PDF file10-2 Cisco ONS 15454 SDH Reference Manual, R4.0 March 2003 Chapter 10 SDH Topologies 10.2 Multiplex Section-Shared Protection Rings
SDH Manual
Operations Manual SDH-12 — mrclab.com · SDH-12 Operations Manual Chapter 1 Introduction ─ 1 ─ Chapter 1 Introduction The Denaturation and Hybridization System SDH-12 is a product
Configuring SDH — cisco.com · SDH Hierarchy SDH Frame Structure TheSTM-1frameisthebasictransmissionformatforSDH.Theframelastsfor125microseconds,therefore, thereare8000framespersecond.TheSTM-
SDH Topologies and Upgrades — cisco.com · 12-2 Cisco ONS 15454 SDH Reference Manual, R7.0 August 2012 Chapter 12 SDH Topologies and Upgrades 12.2 12.2 Multiplex Section-Shared Protection
НовыйанализаторИКМ BERcut-E1АнализаторBERcut-E1 • АнализИКМ–2 потока •G.821, G.826, M.2100 • Джиттер • Формаимпульса
爀 眀眀眀⸀洀攀琀爀漀琀攀欀⸀爀 — metrotek.rumetrotek.ru/wp-content/uploads/2017/09/Bercut-SDH.pdf · Awam,reavop BERcut-SDH MOXeT npvweHRTbcq He TOIlbKO B TPaAhUVlOHHblX
SDH Principles SDH Principles. Course Contents Chapter 1 Emergence of SDH What is SDH? —- Synchronous Digital Hierarchy —-It defines frame structure,
Cisco ONS 15454 SDH Reference Manual
Operation Manual for SDH
JEDNOSTKI ŚCIENNE SDH 14-026 W SDH 14-036 W SDH 14 ……JEDNOSTKI SDH 14-026 W SDH 14-036 W SDH 14-051 W SDH 14-065 W Zasilanie V/Ph/Hz 230/1/50 Wydajność chłodnicza kW 2,65 3,25
SDH Topologies — cisco.com · 10-2 Cisco ONS 15454 SDH Reference Manual, R4.0 March 2003 Chapter 10 SDH Topologies 10.2 Multiplex Section-Shared Protection Rings …
CONSOLAS — notice-facile.com · CONSOLAS Manual de Usuario Manuale di Istruzione Notice d’utilisation User Manual Manual de Instruções CONSOLAS SDH 20-025 NC SDH 20-035 NC SDH
Bedienungsanleitung User Manual Manual de Usuario … · WALL-MOUNTED UNITS SDH 17-025 NW SDH 17-035 NW SDH 17-050 NW SDH 17-065 NW Bedienungsanleitung User Manual Manual de Usuario
IP/PDH/SDH Series TO POINT IP/PDH/SDH Series … — · PDF fileIP/PDH/SDH Series IP/PDH/SDH Series IP/PDH/SDH Series IP/PDH/SDH Series IP/PDH/SDH Series IP/PDH/SDH/Ethernet Series IP/PDH/SDH
SDH Operating Manual
Instrukcja Obsługi — Saunier Duval · jednostka kasetonowa sdh 17 — 050 nk sdh 17 — 070 nk sdh 17 — 090 nk sdh 17 — 105 nk sdh 17 — 140 nk sdh 17 — 140t nk instrukcja obsługi pl
SDH Training Manual
Anexo 1. Manual equipo SDH
CONDUCTOS — sdclima.com · sdh 81-050d sdh 81-065d sdh 81-085d sdh 81-105d sdh 81-130d 2007. esp 2 1- Índice 1- Índice
Installation Manual Manual de Instalación Manuale per l …€¦ · Manuale per l’installatore Manual de Instalação IT ES EN PT. WALL-MOUNTED UNITS SDH 18-050 M2NW SDH 18-060
UPS MODELS: SDH 1000 NP – SDH 1500 NP — UPS · PDF fileUPS MODELS: SDH 1000 NP – SDH 1500 NP – SDH 2200 NP – SDH 3000 NP SDH 2200 ER NP – SDH 3000 ER NP
SDH 333H manual — GENTOS
SDH 14-051 M2NW SDH 14-061 M2NW ES SDH 14 …clientes.saunierduval.es/catalogo-digital/documentos/AA/S14_Multis… · Manual de Instalación MURALES SDH 14-051 M2NW SDH 14-061 M2NW
DTA-SDH/155 Operating Manual · 2018-03-19 · DTA-SDH/155 Operating Manual Shineway Technologies, Inc. 4 1. Instrument Profile . 1.1. Physical Characteristics . This chapter introduces
Универсальная тестовая платформа BERcut-SDH(M)‘рошюра-Bercut-SDHM.pdf · BERcut-SDH(M) поддерживает скорости OTN от OTU1
UPS MODELS: SDH 1000 NP – SDH 1500 NP – SDH 2200 NP – SDH … · SDH 1000 NP – SDH 1500 NP – SDH 2200 NP – SDH 3000 NP SDH 2200 ER NP – SDH 3000 ER NP . 2 INTRODUCTION
NAMC-SDH Technical Reference Manual — nateurope.com · The NAMC-SDH is a high performance standard Advanced Mezzanine Card, single width, mid-size, for SDH/Sonet applications. It
Manual de Instalación MURALES — Repuestos Saunier Duval … · PDF fileManual de Instalación MURALES SDH 14-026 W SDH 14-036 W SDH 14-051 W SDH 14-065 W 2010 ES
Connection-oriented Networks: SONET/SDH, ATM, …directory.umm.ac.id/Networking Manual/Connection-Oriented Network.pdf · Connection-oriented networks : SONET/SDH, ATM, MPLS, and
SDH 15-025 NW SDH 15-035 NW SDH 15-050 NW … — … · EN Installation Manual 2010 WALL UNITS SDH 15-025 NW SDH 15-035 NW SDH 15-050 NW SDH 15-065 NW
Manual Prosedur SDH
SDH Topologies and Upgrades — Cisco · 12-2 Cisco ONS 15454 SDH Reference Manual, R8.0 August 2012 Chapter 12 SDH Topologies and Upgrades 12.2 Multiplex Section-Shared Protection
Manual Para Configuracion de Laptops en Pruebas de Rutas Eth-SDH
Klimageräte für effektives Kühlen€¦ · SDH 17-025 NW SDH 17-035 NW SDH 17-050 NW Außeneinheit Multi-Split: SDH 17-060 MC2NO SDH 17-085 MC3NO SDH 17-085 MC4NO Klimageräte für
Предложите, как улучшить StudyLib
(Для жалоб на нарушения авторских прав, используйте
другую форму
)
Ваш е-мэйл
Заполните, если хотите получить ответ
Оцените наш проект
1
2
3
4
5
Назначение
Анализаторы цифровых потоков BERcut-SDH (далее — анализаторы) предназначены для формирования цифрового измерительного сигнала с заданной тактовой частотой и уровнем мощности или амплитудой импульсов, а также анализе структуры сигнала с заданной чувствительностью приемной части при тестировании цифровой аппаратуры, цифровых трактов и компонентов волоконно-оптических сетей связи на электрических и оптических интерфейсах плезиохронной (PDH), синхронной (SDH) цифровой иерархии, оптических транспортных сетей (OTN), сетей Ethemet/IP.
Описание
Принцип действия анализаторов основан на:
— воспроизведении эталонной частоты встроенным задающим генератором и формировании на оптическом или электрическом выходе различных цифровых испытательных сигналов с заданными параметрами, включая частоту следования и структуру последовательностей импульсных сигналов;
— логическом анализе структуры испытательных или рабочих цифровых сигналов, поступающих на вход анализатора, с преобразованием оптических сигналов в электрические сигналы, регистрации и анализе ошибок и аварийных сигналов в измерительном и рабочем структурированном сигнале в соответствии с рекомендациями Международного союза электросвязи G.821, G.826, G.828, G.829, M.2100/2101 (для PDH, SDH и OTN) и типовой методикой RFC2544 (для Ethernet). Результаты анализа (тестирования) отображаются на встроенном сенсорном цифро-графическом экране и сохраняются в энерго-независимой памяти..
Анализаторы выполняются в виде трех моделей:
BERcut-SDH — портативный анализатор для цифровых трактов PDH/SDH со скоростью до 2,5 Гбит/с (интерфейсы Е1, Е2, Е3, Е4; STM-^, STM-1/4/16);
BERcut-SDH(r) — универсальный анализатор для цифровых трактов PDH/SDH и Ethernet со скоростью до 11,1 Гбит/с: интерфейсы Е1, Е2, Е3, Е4; STM-^, STM-1/4/16/64, OTU1/2; Ethernet 10/100/1000Base-T, 1000Base^, 10GE (тип интерфейса в соответствии с заказом);
BERcut-SDH^) — универсальный анализатор для цифровых трактов PDH/SDH и Ethernet со скоростью до 40/100 Гбит/с. Анализатор модели BERcut-SDH^) состоит из базового блока (платформы), которая в соответствии с заказом комплектуется одним или несколькими вставными тестовыми модулями: 2.5G (до 2,666 Гбит/с); 1G (до 1 Гбит/с); 10G (до 11,095 Гбит/с); 40G (до 43 Гбит/с); 40/100G (до 100 Гбит/с), тип интерфейса в соответствии с заказом.
Некоторые функции анализаторов предоставляются по отдельному заказу. Анализаторы комплектуются оптическими приемопередатчиками XFP, SFP и/или CFP (вставными блоками), тип которых зависит от типа интерфейса, длины волны и длины подлежащей тестированию оптической линии (в соответствии с заказом).
Общий вид анализаторов показан на рисунке 1.
Схема защиты от несанкционированного доступа с помощью однократно используемой этикетки с предупреждающей надписью изображена на рисунке 2.
BERcut-SDH(T)
Рисунок 1
BERcut-SDH(T)
BERcut-SDH^)
BERcut-SDH
Рисунок 2
Программное обеспечение
Программное обеспечение (ПО) встроенное, с управляющими функциями. Идентификационные данные ПО следующие:
Наименование ПО |
Идентификационное наименование ПО |
Номер версии (идентификационный номер) ПО |
Цифровой идентификатор ПО (контрольная сумма исполняемого кода) |
Алгоритм вычисления цифрового идентификатора ПО |
BERcut-SDH |
TХ150е+Build |
4.01 |
— |
— |
BERcut-SDH^) |
RELEASE-7-3-1-0-RU1 |
1.0 |
— |
— |
BERcut-SDH^) |
RootFS |
1.0.20 |
— |
— |
Модули: |
Common |
03.01.02 |
— |
— |
— STM-x/OC-x/PDH |
UX400-2G5 |
01.00.01 |
— |
— |
— STM-64/ОС- 192/10GE |
UX400-10G |
03.06.00 |
— |
— |
— STM-256 |
UX400-40G |
01.01.07-revA |
— |
— |
— UX400-100G/40GE |
UX400-100G/40GE |
01.01.05-revB |
— |
— |
-10/100/1000-T/ 100-FX/1000-X/ 1/2/4G |
UX400-1GE |
01.00.04 |
Анализатор по уровню защиты ПО СИ от непреднамеренных и преднамеренных изменений относится к группе «С». Запись ПО осуществляется в процессе производства. Доступ к внутренним частям анализатора, включая процессор, защищен конструкцией анализатора и этикеткой. Модификация ПО возможна только в сервисных центрах изготовителя.
Характеристика |
Значение |
||||
Пределы допускаемой относительной погрешности тактовой частоты передаваемого сигнала |
±3,5-10-6 |
||||
Электрические интерфейсы |
Е1 |
Е2 |
Е3 |
Е4 |
STM-^ |
Тактовая частота, МГц |
2,048 |
8,448 |
34,368 |
139,264 |
155,520 |
Амплитуда импульсов (для Е1, Е2, Е3) или размах (для Е4, STM-^), В |
3,0/2,37 |
2,37 |
1,0 |
1,0 |
1,0 |
Допустимое отклонение амплитуды импульсов, % |
±10 |
||||
Сопротивление входа и нагрузки на выходе, Ом Затухание несогласованности входа на полутактовой частоте, дБ, не менее |
120/75 18 |
75 18 |
75 18 |
75 15 |
75 15 |
Максимальное затухание сигнала на входе относительно номинального уровня в режиме монитора, дБ |
26 |
||||
Оптические интерфейсы |
Тип блока |
Мощность на выходе, дБм |
Мин. чувствительность входа, дБм |
||
STM-0/1/4 (SFP) |
1310 нм (15 км) |
301-01-004G |
минус 15 — минус 8 |
-28 |
|
1310 нм (40 км) |
301-01-005G |
минус 3 — +2 |
-28 |
||
1550 нм (80 км) |
301-01-006G |
минус 3 — +2 |
-28 |
||
STM-0/1/4/16, OTU-1 (SFP) |
1310 нм (15 км) |
301-01-007G |
минус 5 — 0 |
-18 |
|
1310 нм (40 км) |
301-01-008G |
минус 2 — +3 |
-27 |
||
1550 нм (80 км) |
301-01-009G |
минус 2 — +3 |
-28 |
||
STM-64, OTU-2, OTU-1e, OTU-2e ^FP) |
1310 нм (10 км) |
301-04-002G |
минус 6 — минус 1 |
-13,4 |
|
1550 нм (40 км) |
301-04-003G |
минус 1 — +2 |
-15 |
||
1550 нм (80 км) |
301-04-004G |
0 — +4 |
-22 |
||
10GE LAN и WAN ^FP) |
850 нм (0,3 км) |
301-04-001G |
минус 5 — минус 1 |
— |
|
1310 нм (10 км) |
301-04-002G |
минус 6 — минус 1 |
— |
||
1550 нм (40 км) |
301-04-003G |
минус 1 — +2 |
— |
||
1550 нм (80 км) |
301-04-004G |
0 — +4 |
— |
||
1000Base^ (SFP) |
850 нм (0,3 км) |
301-01-001G |
минус 9 — минус 3 |
— |
|
1310 нм (10 км) |
301-01-002G |
минус 6 — минус 1 |
— |
||
1550 нм (80 км) |
301-01-003G |
0 — +5 |
— |
||
1000Base-FХ (SFP) |
1310 нм (2 км) |
301-01-013G |
минус 20 — минус 15 |
— |
|
1310 нм (15 км) |
301-01-014G |
минус 15 — минус 8 |
— |
||
STM-256 SYNC, STM-64 ASYNC (XFP) |
1550 нм (2 км) |
— |
0 — 3 |
-7 |
|
40GE/100GE/ OTU3/OTU4 (CFP) |
1310 нм (10 км) |
— |
минус (4,5- 4,3)/ поток |
— |
|
Общие характеристики |
BERcut-SDH |
BERcut-SDHCD |
BERcut-SDH^) |
||
Рабочие условия применения: — температура окружающей среды, °C — относительная влажность воздуха, %, не более |
от -10 до +50 85 |
от 0 до +45 85 |
Характеристика |
Значение |
||
Условия хранения, °С — температура окружающей среды, °С — относительная влажность воздуха, %, не более |
от минус 20 до +70 от 5 до 95 |
||
Питание: — от сети переменного тока напряжением, В, частотой, Гц |
100 — 240 50-60 |
||
Габариты (ширинахглубинахвысота), мм, не более |
BERcut-SDH |
BERcut-SDH(I) |
BERcut-SDH^) |
100x210x55 |
290x170x66 |
360x270x180 |
|
Масса, кг, не более |
1 |
3 |
15 |
По условиям эксплуатации анализаторы удовлетворяют требованиям, предъявляемым к аппаратуре по группе 3 ГОСТ 22261-94 с расширенным диапазоном рабочих температур (модели BERcut-SDH^) и BERcut-SDH^)) и по группе 4 (модель BERcut-SDH).
Знак утверждения типа
Знак утверждения типа наносится на заднюю панель анализатора в виде наклеиваемой этикетки и на руководство по эксплуатации типографским способом.
Комплектность
В комплект поставки входят:
— анализатор выбранной модели с выбранными аппаратными и программными опциями;
— сетевой адаптер;
— комплект принадлежностей, включающий измерительные шнуры;
— руководство по эксплуатации на русском языке;
— методика поверки.
Поверка
осуществляется по документу МП 53501-13 «Анализаторы цифровых потоков BERcut-SDH. Методика поверки», утвержденному ФГУП ЦНИИС в 2013 г.
Основные средства поверки:
— частотомер электронно-счетный Ч3-63/1: 0,1 Гц — 1500 МГц, ±5 10-7f ± 1 ед. счета;
— осциллограф универсальный двухканальный широкополосный С1-97: 0-350 МГц; 10 мВ-5 В, погрешность по оси Х и Y <3 %;
— магазин затуханий ТТ-4138/B, 50 Ом, 0-1,3 ГГц; 140 дБ ±1 дБ;
— измеритель средней мощности оптического излучения Алмаз-21: (800-1600) нм, (-60 — +3) дБм; ±0,4 дБм;
— аттенюатор оптический измерительный OLA-15: 1260-1650 нм, (3 — 60) дБ.
Сведения о методах измерений
«Анализаторы цифровых потоков BERcut-SDH. Руководство по эксплуатации». ДДГМ 411618 005РЭ
Нормативные и технические документы, устанавливающие требования к анализаторам цифровых потоков BERcut-SDH
ГОСТ 22261-94 Средства измерений электрических и магнитных величин. Общие технические условия.
ГОСТ 8.129-99 ГСИ. Государственная поверочная схема для средств измерений времени и частоты
ГОСТ 8.585-2005 ГСИ. Государственная поверочная схема для средств измерений длины и времени распространения сигнала в световоде, средней мощности, ослабления и длины волны для волоконно-оптических систем связи и передачи информации
ГОСТ Р 8.761-2011 ГСИ. Государственная поверочная схема для средств измерений импульсного электрического напряжения
Руководство по эксплуатации ДДГМ.411618.005РЭ.
Рекомендации к применению
выполнение работ по оценке соответствия средств связи установленным законодательством Российской Федерации обязательным требованиям и мероприятий государственного контроля (надзора) в сфере связи.
Принцип действия анализаторов основан на:
-
— воспроизведении эталонной частоты встроенным задающим генератором и формировании на оптическом или электрическом выходе различных цифровых испытательных сигналов с заданными параметрами, включая частоту следования и структуру последовательностей импульсных сигналов;
-
— логическом анализе структуры испытательных или рабочих цифровых сигналов, поступающих на вход анализатора, с преобразованием оптических сигналов в электрические сигналы, регистрации и анализе ошибок и аварийных сигналов в измерительном и рабочем структурированном сигнале в соответствии с рекомендациями Международного союза электросвязи G.821, G.826, G.828, G.829, M.2100/2101 (для PDH, SDH и OTN) и типовой методикой RFC2544 (для Ethernet). Результаты анализа (тестирования) отображаются на встроенном сенсорном цифро-графическом экране и сохраняются в энерго-независимой памяти..
Анализаторы выполняются в виде трех моделей:
BERcut-SDH — портативный анализатор для цифровых трактов PDH/SDH со скоростью до 2,5 Гбит/с (интерфейсы Е1, Е2, Е3, Е4; STM-^. STM-1/4/16);
BERcut-SDH(T) — универсальный анализатор для цифровых трактов PDH/SDH и Ethernet со скоростью до 11,1 Гбит/с: интерфейсы Е1. Е2. Е3. Е4; STM-^, STM-1/4/16/64. OTU1/2; Ethernet 10/100/1000Base-T, lOOOBase-Х. 10GE (тип интерфейса в соответствии с заказом);
BERcut-SDH^) — универсальный анализатор для цифровых трактов PDH/SDH и Ethernet со скоростью до 40/100 Гбит/с. Анализатор модели BERcut-SDH^) состоит из базового блока (платформы), которая в соответствии с заказом комплектуется одним или несколькими вставными тестовыми модулями: 2.5G (до 2,666 Гбит/с); 1G (до 1 Гбит/с); 10G (до 11,095 Гбит/с); 40G (до 43 Гбит/с); 40/100G (до 100 Гбит/с), тип интерфейса в соответствии с заказом.
Некоторые функции анализаторов предоставляются по отдельному заказу. Анализаторы комплектуются оптическими приемопередатчиками XFP, SFP и/или CFP (вставными блоками), тип которых зависит от типа интерфейса, длины волны и длины подлежащей тестированию оптической линии (в соответствии с заказом).
Общий вид анализаторов показан на рисунке 1.
Схема защиты от несанкционированного доступа с помощью однократно используемой этикетки с предупреждающей надписью изображена на рисунке 2.
BERcut-SDH
BERcut-SDH(M)
место установки этикетки с пломбирующим эффектом
BERcut-SDH
BERcut-SDH(M)