Дигитайзер agfa cr 15 x инструкция

AGFA CR 10-X User Manual

  1. Manuals
  2. Brands
  3. AGFA Manuals
  4. Measuring Instruments
  5. CR 10-X
  6. User manual

  • Contents

  • Table of Contents

  • Troubleshooting

  • Bookmarks

Quick Links

CR 10-X, CR 12-X, CR 15-X

5151/100

5151/200

5151/300

User Manual

2491E EN 20150409 1543

loading

Related Manuals for AGFA CR 10-X

Summary of Contents for AGFA CR 10-X

  • Page 1
    CR 10-X, CR 12-X, CR 15-X 5151/100 5151/200 5151/300 User Manual 2491E EN 20150409 1543…
  • Page 2: Table Of Contents

    2 | CR 10-X, CR 12-X, CR 15-X | Contents Contents Legal Notice …………….4 Introduction …………….5 Introduction to this Manual ……..6 Scope ………….7 About the safety notices in this document ..8 Disclaimer …………. 9 Introduction to CR 10-X, CR 12-X and CR 15-X ..

  • Page 3
    CR 10-X, CR 12-X, CR 15-X | Contents | 3 Troubleshooting …………59 Digitizer Remote Display ……60 Connection Problems ……..61 Cassette Could Not Be Identified ….62 Cassette release button pressed before end of cycle …………….63 Cannot read data on the image plate ….64…
  • Page 4: Legal Notice

    Agfa and the Agfa rhombus are trademarks of Agfa-Gevaert N.V., Belgium or its affiliates. CR 10-X, CR 12-X, CR 15-X, NX, ADC QS and ADC VIPS are trademarks of Agfa HealthCare N.V., Belgium or one of its affiliates. All other trademarks are held by their respective owners and are used in an editorial fashion with no intention of infringement.

  • Page 5: Introduction

    CR 10-X, CR 12-X, CR 15-X | Introduction | 5 Introduction Topics: • Introduction to this Manual • Introduction to CR 10-X, CR 12-X and CR 15-X 2491E EN 20150409 1543…

  • Page 6: Introduction To This Manual

    6 | CR 10-X, CR 12-X, CR 15-X | Introduction Introduction to this Manual Topics: • Scope • About the safety notices in this document • Disclaimer 2491E EN 20150409 1543…

  • Page 7: Scope

    CR 10-X, CR 12-X, CR 15-X | Introduction | 7 Scope This manual contains information for safe and effective operation of the CR 10-X , CR 12-X and CR 15-X digitizers, further referred to as the digitizer, unless the information applies to a specific type.

  • Page 8: About The Safety Notices In This Document

    8 | CR 10-X, CR 12-X, CR 15-X | Introduction About the safety notices in this document The following samples show how warnings, cautions, instructions and notes appear in this document. The text explains their intended use. DANGER: A danger safety notice indicates a hazardous situation of direct, immediate danger for a potential serious injury to a user, engineer, patient or any other person.

  • Page 9: Disclaimer

    CR 10-X, CR 12-X, CR 15-X | Introduction | 9 Disclaimer Agfa assumes no liability for use of this document if any unauthorized changes to the content or format have been made. Every care has been taken to ensure the accuracy of the information in this document.

  • Page 10: Intended Use

    10 | CR 10-X, CR 12-X, CR 15-X | Introduction Intended Use The digitizer is part of a CR system, further containing a cassette, image plate and modality workstation. The CR system is used in a radiological environment by qualified staff to read-out, process and route static X-ray radiographic images.

  • Page 11: Indications For Use

    CR 10-X, CR 12-X, CR 15-X | Introduction | 11 Indications for Use Agfa’s Computed Radiography (CR) System with CR 10-X, CR 12-X or CR 15-X digitizer is indicated for use in general projection radiographic applications to capture for display diagnostic quality radiographic images of human anatomy.

  • Page 12: Intended User

    12 | CR 10-X, CR 12-X, CR 15-X | Introduction Intended User This manual has been written for trained users of Agfa products and trained diagnostic X–ray clinical personnel who have received proper training. Users are those persons who actually handle the equipment and those who have authority over the equipment.

  • Page 13: Configuration

    CR 10-X, CR 12-X, CR 15-X | Introduction | 13 Configuration The system consists of: • the digitizer for scanning image plates retaining latent X-ray images. The digitizer accepts one cassette containing one image plate at a time. • cassette and plate system: •…

  • Page 14
    14 | CR 10-X, CR 12-X, CR 15-X | Introduction In case of power failure, the batteries of the UPS supply power to the digitizer, the NX workstation and monitor. Full Leg Full Spine Application Components • CR Full Body Cassette Holder •…
  • Page 15: Operation Controls

    CR 10-X, CR 12-X, CR 15-X | Introduction | 15 Operation Controls The digitizer interfaces with the user via: • a power button, • an erase button, • a status indicator, • a cassette release button. Power button Erase button…

  • Page 16
    16 | CR 10-X, CR 12-X, CR 15-X | Introduction Color Constant/ Status Action Blinking Blinking Busy with erasing Wait. and return of the IP into cassette Green Constant Standby mode Proceed. (Ready) Remove cassette. Cassette is ready for removal…
  • Page 17: System Documentation

    • CR 10-X, CR 12-X, CR 15-X User Manual (this document), document 2491. • AGFA CR Plates and Cassettes User Manual, document 2492. • Getting started with CR 10-X, CR 12-X and CR 15-X, document 2493. The NX User Documentation CD contains: • NX user documentation •…

  • Page 18: Training

    18 | CR 10-X, CR 12-X, CR 15-X | Introduction Training The user must have received adequate training on the safe and effective use of the system before attempting to work with it. Training requirements may vary from country to country. The user must make sure that training is received in accordance with local laws or regulations that have the force of law.

  • Page 19: Product Complaints

    If the device malfunctions and may have caused or contributed to a serious injury, Agfa must be notified immediately by telephone, fax or written correspondence to the following address: Agfa Service Support — local support addresses and phone numbers are listed on www.agfa.com Agfa — Septestraat 27, 2640 Mortsel, Belgium…

  • Page 20: Compatibility

    Compatibility The equipment must only be used in combination with other equipment or components if these are expressly recognized by Agfa as compatible. A list of such equipment and components is available from Agfa service on request. Changes or additions to the equipment must only be carried out by persons authorized to do so by Agfa.

  • Page 21: Compliance

    CR 10-X, CR 12-X, CR 15-X | Introduction | 21 Compliance Topics: • General • Safety • Laser Safety • Electromagnetic Compatibility • Environmental Compliance • Equipment Classification General • The product has been designed in accordance with the MEDDEV…

  • Page 22
    22 | CR 10-X, CR 12-X, CR 15-X | Introduction Equipment Classification This device is classified as following: Table 1: Equipment classification Class I equipment Equipment in which protection against electric shock does not relay on basic insulation only, but includes a power supply cord with protective earth conductor.
  • Page 23: Connectivity

    CR 10-X, CR 12-X, CR 15-X | Introduction | 23 Connectivity The digitizer is connected to the workstation via Ethernet connection and uses the DICOM protocol to communicate with the workstation. 2491E EN 20150409 1543…

  • Page 24: Installation

    24 | CR 10-X, CR 12-X, CR 15-X | Introduction Installation WARNING: When using the power supply, care must be taken to ensure that there is either a mains plug or an all-cable disconnecting device in the internal installation fitted near the device and that it is easily accessible in case of emergency.

  • Page 25
    CR 10-X, CR 12-X, CR 15-X | Introduction | 25 The classification of this product according to the medical electrical equipment standard IEC 60601-1 requires installation outside the patient vicinity. For definition of patient vicinity see dimensions below. Patient vicinity Patient vicinity patient_vicinity.cdr…
  • Page 26: Labels

    26 | CR 10-X, CR 12-X, CR 15-X | Introduction Labels Always take into account the markings and labels provided on the inside and outside of the machine. A brief overview of these markings and labels and their meaning is given below.

  • Page 27: Serial Number

    CR 10-X, CR 12-X, CR 15-X | Introduction | 27 Type label Date of manufacture Manufacturer Serial number WEE Symbol, see section about Environmental protection. This mark indicates how to insert the cassette in the slot, depending on the cassette size that is indicated in the mark (CR 15-X only).

  • Page 28
    28 | CR 10-X, CR 12-X, CR 15-X | Introduction divergence is 120 — 350 mrad. The laser beam’s deflection frequency is 70 1/s up to 90 1/s. Under normal operating conditions — device with all covers — there can be no laser radiation outside the digitizer.
  • Page 29: Cleaning And Disinfection

    CR 10-X, CR 12-X, CR 15-X | Introduction | 29 Cleaning and Disinfection All appropriate policies and procedures should be followed to avoid contamination of the staff, patients and device. All existing universal precautions should be taken to avoid that the digitizer and its accessories come into contact with potential contaminations.

  • Page 30: Patient Data Security

    30 | CR 10-X, CR 12-X, CR 15-X | Introduction Patient data security The user must ensure that the patients’ legal requirements are met and that the security of the patient data is guarded. The user must define who can access patient data in which situations.

  • Page 31: Maintenance

    CR 10-X, CR 12-X, CR 15-X | Introduction | 31 Maintenance Topics: • Preventive Maintenance • Cleaning the Optical Unit Preventive Maintenance No regular preventive maintenance is required other than described further in this chapter. The digitizer informs you when preventive maintenance is required and displays the following message «Maintenance interval expired.

  • Page 32: Recurrent Safety Tests

    32 | CR 10-X, CR 12-X, CR 15-X | Introduction Recurrent safety tests The device shall be tested according to IEC 62353* in a time interval of at least 36 months or less if local regulations are different. * Medical electrical equipment – Recurrent test and test after repair of medical electrical equipment.

  • Page 33: Environmental Protection

    CR 10-X, CR 12-X, CR 15-X | Introduction | 33 Environmental protection Figure 2: WEEE symbol Figure 3: Battery symbol WEEE end user notice The directive on Waste Electrical and Electronic Equipment (WEEE) aims to prevent the generation of electric and electronic waste and to promote the reuse, recycling and other forms of recovery.

  • Page 34: Safety Directions

    34 | CR 10-X, CR 12-X, CR 15-X | Introduction Safety Directions WARNING: To avoid risk of electric shock, this equipment must only be connected to a supply mains with protective earth. WARNING: Position the digitizer so that it is possible to disconnect it from the mains power if required.

  • Page 35: General Safety Instructions

    CR 10-X, CR 12-X, CR 15-X | Introduction | 35 CAUTION: The digitizer is not suitable for scanning imaging plates (IPs) exposed with a dose higher than 5000 µG and for CR HD5.0S General a dose higher than 2500 µG.

  • Page 36
    36 | CR 10-X, CR 12-X, CR 15-X | Introduction • Do not allow the digitizer to be subject to excessive vibration during operation, due to unstable ground (e.g. vibration of nearby equipment or footsteps). • Switch off the device before performing any maintenance work or repairs.
  • Page 37: Quality Control

    CR 10-X, CR 12-X, CR 15-X | Introduction | 37 Quality Control Quality control can be performed by means of the Auto QC2 tool. CAUTION: Unnoticed image quality degradation can cause false negative diagnosis. Apply regular quality control according local regulations.

  • Page 38: Getting Started

    38 | CR 10-X, CR 12-X, CR 15-X | Getting started Getting started Topics: • Starting the Digitizer • Basic Workflow • Stopping the Device 2491E EN 20150409 1543…

  • Page 39: Starting The Digitizer

    CR 10-X, CR 12-X, CR 15-X | Getting started | 39 Starting the Digitizer To start the Digitizer: 1. Make sure the digitizer is connected to the control PC and that the control PC is running the appropriate NX software.

  • Page 40: Basic Workflow

    40 | CR 10-X, CR 12-X, CR 15-X | Getting started Basic Workflow The main functions of the system are digitizing image plates and transmitting the digital image data to the image processing station, where you can perform an image quality control.

  • Page 41: Step 1: Select A Patient And Start The Exam

    CR 10-X, CR 12-X, CR 15-X | Getting started | 41 Step 1: Select a patient and start the exam At the NX workstation: 1. Open the Worklist window of NX. In the Worklist window, you can view and manage the exams that are scheduled via the Worklist pane.

  • Page 42: Step 2: Digitize The Image

    42 | CR 10-X, CR 12-X, CR 15-X | Getting started Step 2: Digitize the image At the digitizer: 1. Check that the digitizer is ready for operation: The status indicator on the digitizer constantly lights up in green. 2. Insert the cassette containing the exposed image plate into the cassette slot of the digitizer.

  • Page 43
    CR 10-X, CR 12-X, CR 15-X | Getting started | 43 Figure 6: Inserting 24 cm x 30 cm cassette using the cassette adapter Once the cassette is locked, the status indicator on the digitizer is blinking yellow. Note: The cassette is unidentified, so the digitizer will send a request to the NX station.
  • Page 44
    44 | CR 10-X, CR 12-X, CR 15-X | Getting started 4. As soon as the digitizer has received the complete identification data from the NX station (via Ethernet) it will start digitizing the image plate. The digitizer converts the information of the latent image to digital data.
  • Page 45: Step 3: Perform A Quality Control

    CR 10-X, CR 12-X, CR 15-X | Getting started | 45 Step 3: Perform a quality control At the NX workstation: 1. Select the image on which quality control is to be performed. 2. Prepare the image for diagnosis by using e.g. L/R markers or annotations.

  • Page 46: Step 4: Remove The Cassette And Insert The Next One

    46 | CR 10-X, CR 12-X, CR 15-X | Getting started Step 4: Remove the cassette and insert the next one At the digitizer: 1. When the digitizer has finished treating the cassette, the status indicator constantly lights up in green.

  • Page 47: Stopping The Device

    CR 10-X, CR 12-X, CR 15-X | Getting started | 47 Stopping the Device Topics: • Before Switching Off • Switching Off 2491E EN 20150409 1543…

  • Page 48: Before Switching Off

    48 | CR 10-X, CR 12-X, CR 15-X | Getting started Before Switching Off Check that the digitizer is not scanning an image plate. If the digitizer is scanning an image plate, the status indicator is blinking yellow. Note: A clamped cassette should be removed before switching off the device.

  • Page 49: Switching Off

    CR 10-X, CR 12-X, CR 15-X | Getting started | 49 Switching Off It is recommended to switch off the digitizer at the end of the day. To switch off, press the power button. Power button Note: After switch off, the device is still in stand-by mode. To remove the device from the mains supply disconnect the mains plug.

  • Page 50: Operating Cr 10-X, Cr 12-X And Cr 15-X

    50 | CR 10-X, CR 12-X, CR 15-X | Operating CR 10-X, CR 12-X and CR 15-X Operating CR 10-X, CR 12-X and CR 15- This chapter provides information about functions that are available in operator mode. Finally you will find some preventive maintenance and troubleshooting guidelines.

  • Page 51: Reading An Emergency Image Plate

    CR 10-X, CR 12-X, CR 15-X | Operating CR 10-X, CR 12-X and CR 15-X | 51 Reading an Emergency Image Plate Note: Reading an emergency image plate is a licensed functionality, necessary to facilitate the emergency cases and to improve the workflow.

  • Page 52: Re-Erasing An Image Plate

    52 | CR 10-X, CR 12-X, CR 15-X | Operating CR 10-X, CR 12-X and CR 15-X Re-erasing an Image Plate At the end of a normal or emergency digitizing cycle, the digitizer returns an erased image plate. However, in the following cases, you must re-erase the…

  • Page 53
    CR 10-X, CR 12-X, CR 15-X | Operating CR 10-X, CR 12-X and CR 15-X | 53 Figure 8: Inserting small cassette Figure 9: Inserting 24 cm x 30 cm cassette using the cassette adapter As a result, the digitizer starts erasing the image plate: the status indicator switches to the state “blue blinking”.
  • Page 54: Reading The Initialization Data Of An Image Plate

    54 | CR 10-X, CR 12-X, CR 15-X | Operating CR 10-X, CR 12-X and CR 15-X Reading the Initialization Data of an Image Plate The initialization data stored in the IP barcode can be read via the digitizer. Reading the initialization data of an image plate can be necessary in case you want to find a specific IP.

  • Page 55
    CR 10-X, CR 12-X, CR 15-X | Operating CR 10-X, CR 12-X and CR 15-X | 55 Make sure that the cassette is firmly pushed into the slot, so that it is locked (you should hear a click). Otherwise, the digitizer cannot read the image plate.
  • Page 56
    56 | CR 10-X, CR 12-X, CR 15-X | Operating CR 10-X, CR 12-X and CR 15-X Note: You can only remove the cassette from the cassette slot when the cassette is unlocked. Related Links Cassette formats on page 78…
  • Page 57: Expiry Of Image Plates

    CR 10-X, CR 12-X, CR 15-X | Operating CR 10-X, CR 12-X and CR 15-X | 57 Expiry of Image Plates Topics: • Upcoming Expiry of the Image Plate • Expired Image Plate 2491E EN 20150409 1543…

  • Page 58: Upcoming Expiry Of The Image Plate

    58 | CR 10-X, CR 12-X, CR 15-X | Operating CR 10-X, CR 12-X and CR 15-X Upcoming Expiry of the Image Plate The Digitizer Remote Display informs you about upcoming expiry of the image plate 90 and 30 days before the expiry date. Please replace the image plates before expiry to avoid reduced system performance.

  • Page 59: Troubleshooting

    CR 10-X, CR 12-X, CR 15-X | Operating CR 10-X, CR 12-X and CR 15-X | 59 Troubleshooting In case of a malfunction of the digitizer, consult the Digitizer Remote Display UI (User Interface) messages on the control PC. Error messages are displayed in a dialog box in the middle of the screen or in a fixed part of the screen.

  • Page 60: Digitizer Remote Display

    60 | CR 10-X, CR 12-X, CR 15-X | Operating CR 10-X, CR 12-X and CR 15-X Digitizer Remote Display Digitizer Remote Display is an application running on the NX PC. To verify if Digitizer Remote Display is running, check if the Digitizer Remote Display icon is present in the Windows taskbar: To start the Digitizer Remote Display, go to the Windows Start menu >…

  • Page 61: Connection Problems

    CR 10-X, CR 12-X, CR 15-X | Operating CR 10-X, CR 12-X and CR 15-X | 61 Connection Problems CAUTION: Operation failure of the device can cause delayed diagnosis. Check if Digitizer Remote Display is running. In case the status indicator of the digitizer is blinking red, the user should look at the “status”…

  • Page 62: Cassette Could Not Be Identified

    62 | CR 10-X, CR 12-X, CR 15-X | Operating CR 10-X, CR 12-X and CR 15-X Cassette Could Not Be Identified Details This error message is displayed on the NX PC: Cause A cassette has been inserted in the digitizer and the ID button was clicked directly afterwards.

  • Page 63: Cassette Release Button Pressed Before End Of Cycle

    CR 10-X, CR 12-X, CR 15-X | Operating CR 10-X, CR 12-X and CR 15-X | 63 Cassette release button pressed before end of cycle Details The following error message is displayed in the Digitizer Remote Display: Do not press the cassette release button before end of cycle.

  • Page 64: Cannot Read Data On The Image Plate

    64 | CR 10-X, CR 12-X, CR 15-X | Operating CR 10-X, CR 12-X and CR 15-X Cannot read data on the image plate Details The following error message is displayed in the Digitizer Remote Display: Error during read out of data on the image plate. Remove the cassette and press the confirm button.

  • Page 65: Image Plate Transport Problems

    CR 10-X, CR 12-X, CR 15-X | Operating CR 10-X, CR 12-X and CR 15-X | 65 Image Plate Transport Problems Details The following error message is displayed in the Digitizer Remote Display: Image plate is not erased! Remove the cassette and press the confirm button.

  • Page 66: Removing A Jammed Image Plate

    66 | CR 10-X, CR 12-X, CR 15-X | Operating CR 10-X, CR 12-X and CR 15-X Removing a Jammed Image Plate Note: The technical concept does not allow the user to remove the top cover. Note: The digitizer always reads and digitizes the plate first, then erases it and transports it back into the cassette.

  • Page 67
    CR 10-X, CR 12-X, CR 15-X | Operating CR 10-X, CR 12-X and CR 15-X | 67 7. Slide out the cassette unit with the cassette attached. WARNING: The cassette unit and/or the cassette falling down can cause injury of the operator.
  • Page 68
    68 | CR 10-X, CR 12-X, CR 15-X | Operating CR 10-X, CR 12-X and CR 15-X 2. Open the back of the device by turning the four fixation rings by 90 degrees: 3. Gently remove the image plate from the back of the digitizer.
  • Page 69
    CR 10-X, CR 12-X, CR 15-X | Operating CR 10-X, CR 12-X and CR 15-X | 69 Note: After removing a jammed image plate, erase the image plate before the next exposure. 2491E EN 20150409 1543…
  • Page 70: Behavior In Case Of Power Failure

    70 | CR 10-X, CR 12-X, CR 15-X | Operating CR 10-X, CR 12-X and CR 15-X Behavior in Case of Power Failure Note: The description below is only applicable if an uninterruptible power supply (UPS) is put into the CR system configuration.

  • Page 71: Cleaning The Optical Unit

    CR 10-X, CR 12-X, CR 15-X | Operating CR 10-X, CR 12-X and CR 15-X | 71 Cleaning the Optical Unit The only maintenance action which you must perform is checking the image quality. Refer to the User Manual of the NX software.

  • Page 72
    72 | CR 10-X, CR 12-X, CR 15-X | Operating CR 10-X, CR 12-X and CR 15-X Make sure to return the lever completely to the left, where it is locked in position. 3. Place back the cassette unit. Note that the protruding elements of the cassette unit should be…
  • Page 73: Technical Data

    CR 10-X, CR 12-X, CR 15-X | Technical Data | 73 Technical Data Topics: • Specifications • Cassette formats 2491E EN 20150409 1543…

  • Page 74: Specifications

    74 | CR 10-X, CR 12-X, CR 15-X | Technical Data Specifications Labelling 93/42 EEC ‘Medical Devices’ (Europe), EN 60601-1 (applicable only for equipment made in Germany) c NRTL us NRTL us certified, UL 60601-1 (North America) (applicable only for…

  • Page 75
    CR 10-X, CR 12-X, CR 15-X | Technical Data | 75 Mains fuse protection Europe: min. 10 A, max. 16 A USA & Japan: min. 10 A, max. 15 A Network connectivity Ethernet connector RJ45 female, 10/100 Mbit/s autosensing, shielding CAT5…
  • Page 76
    76 | CR 10-X, CR 12-X, CR 15-X | Technical Data Temperature -25 °C — +55 °C Environmental conditions (during transport) In line with IEC721-3-2 (1997): class 2K2 and 2M3, with following restrictions: Temperature -25 °C — +55 °C Vibration…
  • Page 77
    CR 10-X, CR 12-X, CR 15-X | Technical Data | 77 150 µm 70 s (not applicable for CR HD5.0S General image plate) 118 s 100 µm 88 s End of Life Estimated product life 7 yrs. (if regularly serviced…
  • Page 78: Cassette Formats

    78 | CR 10-X, CR 12-X, CR 15-X | Technical Data Cassette formats Table 2: Supported cassette formats Cassette format CR 10-X, CR 12-X CR 15-X 35 cm x 43 cm 24 cm x 30 cm yes, using the cassette adapter…

  • Page 79: Remarks For Hf-Emission And Immunity

    CR 10-X, CR 12-X, CR 15-X | Remarks for HF-emission and immunity | 79 Remarks for HF-emission and immunity Remarks for HF-emission and immunity It is hereby certified that the digitizer has interference suppression according to the EN 55011 Class A as well as the FCC Rules CR47 Part 15 Class A.

  • Page 80
    80 | CR 10-X, CR 12-X, CR 15-X | Remarks for HF-emission and immunity RF emissions in accordance Class A The device is suitable for use in with CISPR 11 all establishments other than domestic, and may be used in…
  • Page 81
    CR 10-X, CR 12-X, CR 15-X | Remarks for HF-emission and immunity | 81 Voltage The quality of the • < 5% U • < 5% U breakthrough voltage supply should (> 95% (> 95% s, short term correspond to that of…
  • Page 82
    82 | CR 10-X, CR 12-X, CR 15-X | Remarks for HF-emission and immunity Recommended protective distance: Conducted d = 1.2 high frequency 150 kHz to disturbance 80 MHz variables in accordance with IEC 61000-4-6 Radiated high 3 V/m 3 V/m d = 1.2…
  • Page 83
    CR 10-X, CR 12-X, CR 15-X | Remarks for HF-emission and immunity | 83 investigation of the location is recommended, to ascertain the electromagnetic environment as a result of stationary high frequency transmitters. If the field strength of the device exceeds the level of agreement given above, the device must be observed with regard to its normal operation at each place of use.
  • Page 84
    84 | CR 10-X, CR 12-X, CR 15-X | Remarks for HF-emission and immunity The distance can be determined through the equation for each respective column. P is the rated power of the transmitter in watts (W) according to the manufacturer information on the transmitter, only for transmitters where the rated power is not mentioned in the above table.

User Manuals, Guides and Specifications for your AGFA CR 15-X Measuring Instruments. Database contains 1 AGFA CR 15-X Manuals (available for free online viewing or downloading in PDF): Operation & user’s manual .

Универсальное и компактное решение для компьютерной рентгенографии с высоким качеством изображения и высокой скоростью.

  • Доступно для широкого спектра обследований
  • Удобная и быстрая обработка с управляемыми пользователем скоростью и разрешением
  • Надежный и легкий в установке и техническом обслуживании
  • Подходит для установки в местах с ограниченным пространством и в передвижных средствах
  • Возможности сетевого подключения обеспечивают полную интеграцию
  • Универсальный и компактный дигитайзер CR 15-X предлагает идеальное решение для децентрализованной больничной среды, клиник и частных практик

Подходит для установки в местах с ограниченным пространством и в передвижных средствах

Дигитайзер CR 15-X, имеющий размер настольного устройства, может легко располагаться в любом, даже небольшом, месте, а его конструкция предусматривает удобство в эксплуатации. Дигитайзер CR 15-X также можно устанавливать в автомобили, микроавтобусы, грузовики и другие транспортные средства для мобильного использования. Устройство обладает низким расходом электроэнергии, а соединение с автомобильной батареей выполняется без каких-либо трудностей.

Балансировка скорости и разрешения

Используя AGFA CR 15-X, пользователь может выбрать регулировку скорости и разрешения в зависимости от требований обследования. Пользователь может легко изменить настройки по умолчанию для каждого обследования, в зависимости от конкретных приоритетов скорости/качества. Интеллектуальное программное обеспечение для обработки изображений MUSICA компании Agfa HealthCare автоматически оптимизирует качество изображения.

Надежный и легкий в установке и техническом обслуживании

Установка CR 15-X выполняется быстро и легко. Благодаря концепции использования «одной отвертки» и модульной, компонентной конструкции, техническое обслуживание также выполняется быстрее, легче и экономичнее. Следовательно, расходы на установку ниже, а сама установка проще. Горизонтальная установка кассеты предотвращает попадание пыли и грязи при нормальной работе устройства.

Возможности сетевого подключения обеспечивают полную интеграцию

Дигитайзер CR 15-X полностью совместим со стандартом DICOM для легкой интеграции с другими устройствами; мы рекомендуем использовать его вместе с пакетом программного обеспечения SE компании Agfa HealthCare для диагностического просмотра, написания заключений и архивации медицинских изображений или с принтером DRYSTAR 5302 для визуализации на твердом носителе.

Размеры кассет Пространственное разрешение
CR MD1.0 GENERAL 35×43
  • 10 пикс/мм (включая обследования ног/позвоночника во всю длину)
  • 6.6 пикс/мм
  • 5 пикс/мм (включая обследования ног/позвоночника во всю длину)
CR MD1.0 GENERAL 24×30
  • 10 пикс/мм
  • 6.6 пикс/мм
  • 5 пикс/мм
CR MD1.0 GENERAL 18×24
  • 10 пикс/мм
  • 6.6 пикс/мм
  • 5 пикс/мм
CR MD1.0 GENERAL 15×30
  • 10 пикс/мм
  • 6.6 пикс/мм
  • 5 пикс/мм

Вы также можете приобрести кассеты отдельно.

Технические данные

Тип дигитайзера

Однокассетный

Производительность

До 102 пластин в час (в зависимости от размера и разрешения)

Дисплей

  • Светодиодный индикатор состояния
  • Вывод сообщений о состоянии и ошибках на монитор внешнего компьютера
Разрешение шкалы серого

  • Получение данных: 20 бит/пикс
  • Вывод на процессор: 16 бит/пикс
Габаритные размеры и масса

  • (ШxГxВ): 580 x 700 x 471 мм
  • Глубина без кассетного блока и задней крышки: 380 мм
  • Масса: 30 кг
Электропитание

  • Внешний блок питания с автоматическим
    определением параметров электропитания: (выходное напряжение 24 В)
  • Входное напряжение:
    • 100 — 240 В
    • < 2 А
    • 50/60 Гц
    • предохранитель: Европа – макс. 16 А; США – макс. 15 А
Минимальные требования

  • Пластины для общей рентгенографии CR MD1.0
  • Кассеты для общей рентгенографии CR MD1.0
  • Рабочая среда AGFA NX
Условия окружающей среды

В соответствии с требованиями: IEC 721-3-3 (1997): класс 3K2, с учетом следующего условия: — Температура: 15 — 35 °C

Воздействие на окружающую среду

  • Уровень шума: макс. 65 дБ (A)
  • Теплоотдача: в режиме ожидания 30 Вт, макс. 140 Вт
Использование в составе передвижной установки

В соответствии с требованиями IEC721-3-3 (1997): 3K2 со следующими ограничениями:

  • Температура: от +15 °C до +35 °C
  • Относительная влажность: 15 — 75 % RH (без конденсации)
  • Во время транспортировки с мобильным комплектом: в соответствии с требованиями IEC721-3-5: 5K1 и 5M3
Транспортировка

В соответствии с требованиями: IEC 721-3-2 (1997): класс 2K2, со следующими ограничениями: от -25 до +55 °C

Хранение
  • Устройство в упаковке способно выдерживать механические нагрузки в соответствии с требованиями: IEC 721-3-1: класс 1M2 и IEC 721-3-2 (1993): класс 2M3; в том числе при перевозке морским транспортом
  • В соответствии с требованиями IEC721-3-1: класс 1K4

Безопасность

Общая информация

Сертификаты: CE, cNRTLus

Данное изделие разработано в соответствии с указаниями MEDDEV, относящимися к применению Медицинских устройств, и было протестировано как часть процедур оценки соответствия требованиям Директивы о медицинском оборудовании 93/42/ EEC (Директивы Европейского совета 93/42/EEC на Медицинских устройствах).

  • ISO 13485:2003
  • IEC 62304:2006
  • IEC 62366:2007
  • ISO 14971:2007
Безопасность
  • IEC 60601-1:2005
  • UL 60601-1:2003
  • CAN/CSA C22.2 No 601.1-M90
Безопасность лазера
  • IEC 60825-1:1993
  • IEC 60825-1:2007
Электромагнитная совместимость
  • IEC 60601-1-2-2007
  • Правила FCC 47 CRF часть 15 подраздел B
  • CAN/CSA 22.2 No 60601-1-2-08
Соблюдение законов об охране окружающей среды
  • WEEE 2012/19/EC
  • RoHS 2 Директива 2011/65/EU

AGFA Healthcare logo


info

  • «»
  • sales@techno-med.ru

Возможен как безналичный расчёт, так и оплата наличными в офисе. Наши менеджеры оформят все необходимые документы.

Вы можете выбрать удобный для вас способ оплаты медицинской техники и оборудования в зависимости от формы организации вашего учреждения – коммерческой, государственной, либо произвести оплату в качестве физического лица:

icon-1 Для государственных лечебных учреждений:
Реализация медицинского оборудования производится в полном соответствии с действующими Федеральными законами: 44-Ф3, 223-Ф3. Наша компания аккредитована на всех известных электронных торговых площадках РФ. Также мы зарегистрированы на официальном государственном портале поставщиков, что позволяет нам размещать оферты на любое интересное для вас оборудование.

icon-2 Для коммерческих организаций:
Оплата производится посредством безналичного расчёта на основании договора и счёта. Условия договора согласуются в индивидуальном порядке.

icon-3 Для физических лиц:
Мы выставляем счёт и договор, заказ оплачивается через любой банк, клиентом которого вы являетесь. (Перечисление не подразумевает открытие счёта, в банке понадобится только выставленный нашей компанией счёт и паспорт плательщика). Также возможна онлайн-оплата через сервис приёма онлайн-платежей Robokassa.

Также ЗАО «ТЕХНО-МЕД» предлагает выгодный лизинг (аренду с правом выкупа), рассрочку и Trade-in (обмен старого на новое с доплатой) медицинского оборудования. За более детальной информацией обратитесь к нашим менеджерам.

ЗАО «ТЕХНО-МЕД» осуществляет оперативную доставку медицинского оборудования по всей России, Беларуси и Казахстану.

По России — любой транспортной компанией, по согласованию с Вами (Деловые линии, DHL Express, СДЭК и т.д.).

По Санкт-Петербургу — собственной курьерской службой. В нашей компании есть парк автомобилей, позволяющий самостоятельно и в короткие сроки доставлять продукцию по Санкт-Петербургу и Ленинградской области.

Самовывоз с нашего склада по адресу г.Санкт-Петербург, Большой Сампсониевский пр-кт., д. 60 лит. Н.


ТЕХНИЧЕСКОЕ ГАРАНТИЙНОЕ ОБСЛУЖИВАНИЕ

Мы гарантируем высокое качество сервиса собственными силами. Предоставляем техническое обслуживание, гарантийный и постгарантийный ремонт. Мы сделаем все возможное, чтобы ваш рентген аппарат работал бесперебойно на протяжении всего его срока службы.

customDescriptionPic1 customDescriptionPic2 customDescriptionPic3

CR 15-XBirgitte Baten2020-01-27T11:23:58+01:00

СКОРОСТЬ, ГИБКОСТЬ И КАЧЕСТВО

При переходе на цифровой формат вам необходимо решение, которое будет работать так, как нужно вам. Решение, которое является гибким и универсальным. Которое предлагает высокое качество изображений, и сконструировано так, чтобы оставаться легким и доступным по цене. Компактное и быстрое, и поддерживающее широкий асортимент приложений… Которое, однако, позволяет вам самостоятельно определять свой рабочий процесс и адаптировать его в любое удобное для вас время, быстро и с легкостью. Всё это сочетается в CR 15-X.

  • Универсальное и экономически эффективное оборудование для многих исследований
  • Идеально подходит для условий ограниченного пространства
  • Низкая общая стоимость владения
  • Добротное и надежное решение
  • Возможность снижения дозы облучения благодаря использованию цезиевых игольчатых детекторов
  • На базе технологии MUSICA — никаких компромиссов по поводу качества изображений!

Универсальность и беспроблемная интеграция

CR-15-X

Движущей силой в современной экономически сложной среде является возможность повышения эффективности имеющегося у вас оборудования. Универсальность дигитайзера CR 15 и способность его к интеграции интенсифицируют рабочий процесс, что приводит к максимальному повышению рентабельности ваших капиталовложений. Благодаря простой, но продуманной новой концепции дизайна дигитайзер CR 15-X является доступным по цене первым шагом в мир цифровой рентгенографии. Это идеальный выбор для организаций с ограниченным бюджетом, который позволит удовлетворить их нужды как в плане эффективности рабочего процесса, так и в плане разрешения изображений.

Снижение дозы облучения до 60 %

Поддерживая как стандартные «фосфорные» пластины, так и игольчатые детекторы, CR 15-X сочетает в себе абсолютное удобство с высоким качеством изображений, в то же время эффективно используя капиталовложения, уже сделанные в рентгенографическом отделении. Со стандартными «фосфорными» пластинами CR 15-X выдает превосходное качество изображений. Однако при использовании с цезиевыми игольчатыми детекторами дигитайзер CR 15-X обеспечивает великолепное качество изображений и возможность существенного снижения дозы облучения (до 60 %).

К цифровым технологиям вместе с CR 15-X — ваш оптимальный выбор!

ТЕХНОЛОГИЯ ВИЗУАЛИЗАЦИИ MUSICA

Программное обеспечение для обработки изображений MUSICA (Multi-Scale Image Contrast Amplification, обработка изображений с разномасштабным усилением контраста) улучшает качество изображений и рабочий процесс для рентгенолаборантов и радиологов. Благодаря нашим последним технологическим улучшениям повышается степень детализации изображений, а также удобство и уверенность при их прочтении. Почувствуйте разницу!

УПРАВЛЕНИЕ ДОЗОЙ — ДЕЛО КАЖДОГО!

Решения компании Agfa по цифровой рентгенографии задуманы таким образом, чтобы обеспечивать оптимальный баланс между низкой дозой облучения и высоким качеством изображений, предлагая при этом инструменты для контролирования экспозиции пациента.

* В ходе испытания, проведенного сертифицированными радиологами, было определено, что детекторы на основе бромида цезия (CR) и йодида цезия (DR) при использовании вместе с системой обработки изображений MUSICA могут обеспечить снижение дозы порядка 50–60 % (по сравнению с традиционными CR-системами на основе фтор-бромида бария). За дополнительной информацией обратитесь в компанию Agfa!

Не удалось найти интересующую вас информацию?

Заполните приведенную ниже форму, и мы вернемся к вам с индивидуально подобранным ответом. Подробно опишите, что именно вы искали.


  • Описание


  • Характеристики


  • О бренде


  • Информация о гарантии

Применение в оцифровщике игольчатых детекторов помогает более, чем наполовину снизить лучевую нагрузку, возможность управления разрешением и скоростью обработки дает возможность быстро получать изображения необходимого качества в зависимости от задач исследования. Аппарат имеет блочно-модульную конструкцию, прост, надежен и удобен в обслуживании, загрузка кассеты горизонтальная, что обеспечивает защиту от попадания пыли и грязи.

Дигитайзер оснащен специальным программным обеспечением MUSICA, позволяющим проводить интеллектуальную обработку изображений. Возможна установка оцифровщика в передвижных кабинетах, базирующихся на автомобилях, аппарат легко подключается и работает с автомобильным аккумулятором.

Стандартная поставка включает в себя сам дигитайзер, компьютер для лаборанта с установленной программой NX, мультиформатную камеру AGFA Drystar 5302, запас пленки, кассеты стандартных размеров 18х24,24х30, 35х43 по 2 каждого размера. Опционально доступна дополнительная (до 3 лет) гарантия на запчасти, ноутбук для лаборанта, кассеты с детекторами игольчатого типа, компьютер с монитором для врача, мобильная подставка.

agfa

Информация о гарантии

Ограниченная гарантия Medteh является добровольной гарантией изготовителя. Она предоставляет права вне зависимости от прав, устанавливаемых законом о защите прав потребителей, законов 44-ФЗ и 223-ФЗ включая, помимо прочего, права в отношении продуктов, не соответствующих требованиям.
Следовательно, преимущества, предоставляемые Ограниченной гарантией Medteh, дополняют, а не заменяют права, предусмотренные законодательством о правах потребителей, законами 44-ФЗ или 223-ФЗ.
Важно! Гарантийное обслуживание осуществляется в течении 12 месяцев с момента поставки оборудования клиенту.

Понравилась статья? Поделить с друзьями:
  • Китфорт аэрогриль инструкция по применению китфорт
  • Коллаген эс энд джей капс 790 мг x30 инструкция
  • Теноретик инструкция по применению цена отзывы аналоги
  • При ком было создание военных поселений под руководством аракчеева
  • Бисептрим таблетки инструкция по применению взрослым