Fcu 2160 руководство

  1. Manuals
  2. Brands
  3. Rosemount Manuals
  4. Measuring Instruments
  5. TankRadar Rex FCU 2160

Manuals and User Guides for Rosemount TankRadar Rex FCU 2160. We have 1 Rosemount TankRadar Rex FCU 2160 manual available for free PDF download: Service Manual

Rosemount Tank Radar Rex

Chapter 9 Technical Data

9.6

FCU 2160

Ambient operating temperature

Power Supply

Group bus interface

Field bus interface

Explosion protection

Number of tanks per FCU

9-6

Service Manual

-40 °C to +70 °C (-40 °F to +158 °F)

115 or 230 VAC, +10% to -15%, 50-60

Hz, max. 10 W

TRL/2 Bus, RS-232 or RS-485,

Modbus based protocol

TRL/2 Bus. Max 8 units on one port

None

Max 32 (max 8 per field bus is recom-

mended)

308012En, Ed.2

May 2013

User Manuals, Guides and Specifications for your Rosemount TankRadar Rex FCU 2160 Measuring Instruments. Database contains 1 Rosemount TankRadar Rex FCU 2160 Manuals (available for free online viewing or downloading in PDF): Service manual .

Модуль полевого соединения FCU 2160 осуществляет опрос устройств системы: радарных уровнемеров RTG, модулей DAU – и записывает данные в буферную память. При получении запроса модуль FCU незамедлительно пересылает их из буферной памяти.

Модуль FCU является основным (мастер) устройством для полевой шины, и подчиненным устройством для групповой. Прибор имеет 6 коммуникационных портов. Порты могут быть индивидуально сконфигурированы либо в качестве портов групповой шины, либо в качестве портов полевой шины.

Если у вас есть вопросы, пожалуйста, позвоните по телефону: +7 (499) 922-40-10 или заполните форму обратной связи.

Reference Manual

300530EN, Rev BA

September 2012

Rosemount 2410 Series

4-6 Section 4. Configuration

4.6.3 FCU 2160 Configuration

In case the system includes a 2160 Field Communication Unit (FCU), it has to

be installed prior to installing the Rosemount 2410 Tank Hub. The following is

a brief description of how to install a 2160 FCU. See the Raptor System

Configuration Manual (Document no. 300510EN) for a more comprehensive

description.

To install and configure a 2160 FCU:

1. Start the installation wizard in TankMaster WinSetup and choose Device

Type=FCU 2160.

2. Enable communication with the TankMaster PC:

Select communication channel

Set the communication address

3. Configure the FCU: specify Port type (Field Bus/Group Bus), Baud rate,

Data bits, Stop bits, and Parity.

4. Configure the Slave Database.

Set Slave Type=2410_Level in the first free position of the Slave Type

column.

A 2410_Temp device is automatically added to the Slave Database.

Ensure that the Modbus Addresses of the connected devices are

properly set. These addresses must correspond to the 2410 Tank Hub

database settings (see “Basic Configuration of a Rosemount 2410” on

page 4-3 for more information).

Figure 4-2. The Slave Database

has to be configured for level

gauges and temperature

transmitters

2410_Level

2410_Temp is

automatically added