Fr e740 руководство

  1. Manuals
  2. Brands
  3. Mitsubishi Electric Manuals
  4. DC Drives
  5. FR-E740

Manuals and User Guides for Mitsubishi Electric FR-E740. We have 2 Mitsubishi Electric FR-E740 manuals available for free PDF download: Instruction Manual

Mitsubishi Electric FR-E740 Instruction Manual

Mitsubishi Electric FR-E740 Instruction Manual (524 pages)

Frequency Inverter

Brand: Mitsubishi Electric
|
Category: DC Drives
|
Size: 15.31 MB

Table of Contents
  • Instruction Manual

    1

  • Safety Instructions

    5

  • Table of Contents

    11

  • 1 Product Checking and Part Identification

    19

    • Inverter Type

      19

    • Description of the Case

      20

      • Accessory

        21

  • 2 Installation

    23

    • Removal and Reinstallation of the Front Cover

      23

      • FR-E720S and FR-E740-016 to FR-E740-170

        23

      • FR-E740-230 and FR-E740-300

        24

    • Removal and Reinstallation of the Wiring Cover

      26

    • Mounting

      27

    • Enclosure Design

      29

      • Inverter Installation Environment

        29

      • Inverter Placement

        33

  • 3 Wiring

    35

    • Inverter and Peripheral Devices

      35

      • Peripheral Devices

        37

    • Terminal Connection Diagramm

      38

    • Main Circuit Connection

      40

      • Specification of Main Circuit Terminal

        40

      • Terminal Layout and Wiring

        41

    • Control Circuit Specifications

      48

      • Control Circuit Terminals

        51

      • Wiring Instructions

        53

      • Changing the Control Logic

        54

    • PU Connector

      57

      • Connecting the Operation Panel Using a Connection Cable

        57

      • RS485 Communication

        58

    • USB Connector

      59

    • Connection of Stand-Alone Option Units

      60

      • Magnetic Contactors (MC)

        60

      • Connection of a Dedicated External Brake Resistor FR-ABR and MRS (FR-E720S-030 or More, FR-E740-016 or More)

        62

      • Connection of a Brake Unit FR-BU2

        66

      • Connection of the High Power Factor Converter FR-HC

        69

      • Connection of the Power Regeneration Common Converter FR-CV

        70

      • Connection of the Power Improving DC Reactor FR-HEL

        71

      • Installation of a Reactor

        71

    • Electromagnetic Compatibility (EMC)

      72

      • Leakage Currents and Countermeasures

        72

      • Inverter-Generated Noises and Their Reduction Techniques

        76

      • Power Supply Harmonics

        79

      • Inverter-Driven 400V Class Motor

        80

  • 4 Operation

    81

    • Precautions for Use of the Inverter

      81

      • Failsafe of the System Which Uses the Inverter

        83

    • Drive the Motor

      86

    • Operation Panel

      87

      • Parts of the Operation Panel

        87

      • Basic Operation (Factory Setting)

        89

      • Easy Operation Mode Setting (Easy Setting Mode)

        90

      • Operation Lock

        92

      • Monitoring of Output Current and Output Voltage

        94

      • First Priority Monitor

        94

      • Digital Dial Push

        94

      • Change the Parameter Setting Value

        95

      • Parameter Clear/All Parameter Clear

        96

      • Initial Value Change List

        97

  • 5 Basic Settings

    99

    • Simple Mode Parameter List

      99

      • Overheat Protection of the Motor by the Inverter

        100

      • When the Rated Motor Frequency Is 60Hz (Pr. 3)

        102

      • Increase the Starting Torque (Pr. 0)

        103

      • Limit the Maximum and Minimum Output Frequency (Pr. 1, Pr. 2)

        105

      • Change the Acceleration/Deceleration Time (Pr. 7, Pr. 8)

        107

      • Operation Mode (Pr. 79)

        109

      • Large Starting Torque and Low Speed Torque Are Necessary (Advance Magnetic Flux Control, General-Purpose Magnetic Flux Vector Control) (Pr. 71, Pr. 80, Pr. 81, Pr. 800)

        110

      • To Exhibit the Best Performance of the Motor Performance (Offline Auto Tuning) (Pr. 9, Pr. 71, Pr. 83, Pr. 84, Pr. 96)

        113

    • PU Operation Mode

      118

      • Set the Set Frequency to Operate

        119

      • Use the Digital Dial Like a Potentiometer to Perform Operation

        121

      • Use Switches to Give the Frequency Command (Multi-Speed Setting)

        122

      • Perform Frequency Setting by Analog Voltage Input

        124

      • Perform Frequency Setting by Analog Current Input

        126

    • External Operation

      128

      • Use the Set Frequency Set by the Operation Panel (Pr. 79 = 3)

        128

      • Use Switches to Give a Start Command and a Frequency Command (Multi-Speed Setting) (Pr. 4 to Pr. 6)

        130

      • Perform Frequency Setting by Analog Voltage Input

        133

      • Change the Frequency (40Hz) of the Maximum Value of Potentiometer (at 5V)

        136

      • Perform Frequency Setting by Analog Current Input

        137

      • Change the Frequency (40Hz) of the Maximum Value of Potentiometer (at 20Ma)

        139

  • 6 Parameter

    141

    • Parameter Overview

      141

    • Control Mode

      170

      • Change the Control Method (Pr. 80, Pr. 81, Pr. 800)

        171

    • Adjust the Output Torque (Current) of the Motor

      181

      • Slip Compensation (Pr. 245 to Pr. 247)

        181

      • Stall Prevention

        182

      • Torque Limit

        182

    • Limit the Output Frequency

      190

      • Maximum and Minimum Frequency (Pr. 1, Pr. 2, Pr. 18)

        190

      • Avoid Mechanical Resonance Points (Frequency Jumps)

        192

    • Set V/F Pattern

      194

      • Base Frequency, Voltage (Pr. 3, Pr. 19, Pr. 47)

        194

      • Load Pattern Selection (Pr. 14)

        196

    • Frequency Setting by External Terminals

      198

      • (Pr. 4 to Pr. 6, Pr. 24 to Pr. 27, Pr. 232 to Pr. 239)

        198

      • Jog Operation (Pr. 15, Pr. 16)

        201

      • Remote Setting Function (Pr. 28)

        205

    • Acceleration and Deceleration

      209

      • Acceleration and Deceleration Time (Pr. 7, Pr. 8, Pr. 20, Pr. 21, Pr. 44, Pr. 45, Pr. 147)

        209

      • Starting Frequency and Start-Time Hold Function

        213

      • Acceleration and Deceleration Pattern (Pr. 29, Pr. 140 to Pr. 143)

        215

        • (Automatic Acceleration/Deceleration)

          217

        • (Pr. 61 to Pr. 63, Pr. 292, Pr. 293)

          217

    • Selection and Protection of a Motor

      220

      • Motor Overheat Protection (Electronic Thermal O/L Relay)

        220

      • Applied Motor (Pr. 71, Pr. 450)

        225

      • To Exhibit the Best Performance of the Motor Performance

        228

    • Motor Brake and Stop Operation

      238

      • DC Injection Brake (Pr. 10 to Pr. 12)

        238

      • Selection of a Regenerative Brake (Pr. 30, Pr. 70)

        241

      • Stop Selection (Pr. 250)

        243

      • Brake Sequence Function (Pr. 278 to Pr. 283, Pr. 292)

        249

    • Function Assignment of External Terminals

      254

      • Input Terminal Function Selection (Pr. 178 to Pr. 184)

        254

      • Inverter Output Shutoff Signal (MRS Signal, Pr. 17)

        257

      • Condition Selection of Function Validity by Second

        259

        • Function Selection Signal (RT, Pr. 155)

          259

      • Start Signal Selection (Terminal STF, STR, STOP, Pr. 250)

        260

      • Output Terminal Function Selection (Pr. 190 to Pr. 192)

        264

      • Detection of Output Frequency (SU, FU, Pr. 41 to Pr. 43)

        269

      • Output Current Detection Function (Y12, Y13, Pr. 150 to Pr. 153)

        271

      • Remote Output Function (REM, Pr. 495 to Pr. 497)

        273

    • Monitor Display and Monitor Output Signals

      276

      • Speed Display and Speed Setting (Pr. 37)

        276

      • Monitor Display Selection of DU/PU and Terminal am (Pr. 52, Pr. 158, Pr. 170, Pr. 171, Pr. 268, Pr. 563, Pr. 564)

        278

      • Reference of the Terminal am (Analog Voltage Output)

        286

      • Terminal am Calibration

        288

    • Operation Selection at Power Failure

      291

      • Automatic Restart (Pr. 30, Pr. 57, Pr. 58, Pr. 96, Pr. 162, Pr. 165, Pr. 298, Pr. 299, Pr. 611)

        291

      • Power Failure-Time Deceleration-To-Stop Function (Pr. 261)

        302

    • Operation Setting at Alarm Occurrence

      306

      • Retry Function (Pr. 65, Pr. 67 to Pr. 69)

        306

      • Input/Output Phase Failure Protection Selection (Pr. 251, Pr. 872)

        309

      • Earth (Ground) Fault Detection at Start (Pr. 249)

        310

    • Energy Saving Operation

      311

      • Optimum Excitation Control (Pr. 60)

        311

    • Motor Noise, EMI Measures, Mechanical Resonance

      312

      • PWM Carrier Frequency and Soft-PWM Control (Pr. 72, Pr. 240)

        312

      • Speed Smoothing Control (Pr. 653)

        313

    • Frequency Setting by Analog Input (Terminal 2, 4)

      314

      • Analog Input Selection (Pr. 73, Pr. 267)

        314

      • Input Filter Time Constant (Pr. 74)

        319

      • Bias and Gain of Frequency Setting Voltage (Current) [Pr. 125, Pr. 126, Pr. 241, C2 (Pr. 902) to C7 (Pr. 905)]

        320

    • Misoperation Prevention and Parameter Setting Restriction

      327

      • Reset Selection/Disconnected PU Detection/Pu Stop Selection

        327

      • Parameter Write Selection (Pr. 77)

        332

      • Reverse Rotation Prevention Selection (Pr. 78)

        334

      • User Groups (Pr. 160, Pr. 172 to Pr. 174)

        335

    • Selection of Operation Mode and Operation Location

      338

      • Operation Mode Selection (Pr. 79)

        338

      • Operation Mode at Power on (Pr. 79, Pr. 340)

        350

      • Start Command Source and Frequency Command Source During Communication Operation (Pr. 338, Pr. 339, Pr. 550, Pr. 551)

        352

    • Communication Operation and Setting

      361

      • PU Connector

        361

      • Initial Settings and Specifications of RS-485 Communication

        366

      • Communication E²PROM Write Selection (Pr. 342)

        372

      • Mitsubishi Inverter Protocol (Computer Link Communication)

        373

      • Error Code

        379

      • Modbus-RTU Communication (Pr. 117, Pr. 118, Pr. 120, Pr. 122, Pr. 343, Pr. 549)

        391

      • USB Communication (Pr. 547, Pr. 548)

        409

    • Special Operation

      410

      • PID Control (Pr. 127 to Pr. 134)

        410

      • Dancer Control (Pr. 44, Pr. 45, Pr. 128 to Pr. 134)

        422

      • Droop Control (Pr. 286 to Pr. 287)

        431

      • Regeneration Avoidance Function (Pr. 665, Pr. 882, Pr. 883, Pr. 885, Pr. 886)

        432

    • Useful Functions

      435

      • Cooling Fan Operation Selection (Pr. 244)

        435

      • Display of the Life of the Inverter Parts (Pr. 255 to Pr. 259)

        436

      • Maintenance Timer Alarm (Pr. 503, Pr. 504)

        440

      • Current Average Value Monitor Signal (Pr. 555 to Pr. 557)

        441

      • Free Parameters (Pr. 888, Pr. 889)

        445

    • Setting for the Parameter Unit, Operation Panel

      446

      • RUN Key Rotation Direction Selection (Pr. 40)

        446

      • PU Display Language Selection (Pr. 145)

        446

      • Operation Panel Frequency Setting/Key Lock Operation Selection

        447

      • Magnitude of Frequency Change Setting (Pr. 295)

        448

      • Buzzer Control (Pr. 990)

        449

      • PU Contrast Adjustment (Pr. 991)

        449

  • 7 Troubleshooting

    451

    • List of Alarm Display

      452

    • Causes and Corrective Actions

      454

    • Reset Method of Protective Function

      466

    • LED Display

      467

    • Check and Clear of the Fault History

      468

    • Check First When You Have Troubles

      470

      • Motor Does Not Start

        470

      • Motor or Machine Generates Abnormal Noise

        472

      • Inverter Generates Abnormal Noise

        472

      • Motor Generates Heat Abnormally

        473

      • Motor Rotates in Opposite Direction

        473

      • Speed Greatly Differs from the Setting

        473

      • Acceleration/Deceleration Is Not Smooth

        474

      • Speed Varies During Operation

        475

      • Operation Mode Is Not Changed Properly

        476

      • Operation Panel Display Is Not Operating

        476

      • Motor Current Is too Large

        477

      • Speed Does Not Accelerate

        478

      • Unable to Write Parameter Setting

        479

    • Meters and Measuring Methods

      480

      • Measurement of Powers

        481

      • Measurement of Voltages and Use of PT

        482

      • Measurement of Currents

        482

      • Use of CT and Transducer

        483

      • Measurement of Inverter Input Power Factor

        483

      • Measurement of Converter Output Voltage (Across Terminals + and -)

        483

  • 8 Maintenance and Inspection

    485

    • Inspection

      485

      • Daily Inspection

        485

      • Periodic Inspection

        485

      • Daily and Periodic Inspection

        486

      • Display of the Life of the Inverter Parts

        488

      • Checking the Inverter and Converter Modules

        489

      • Cleaning

        490

      • Replacement of Parts

        490

      • Inverter Replacement

        494

    • Measurements on the Main Circuit

      495

      • Insulation Resistance Test Using Megger

        495

      • Pressure Test

        495

      • Measurement of Voltages and Currents

        496

  • Appendix

    499

    • Specifications

      499

      • 1-Phase, 200V Class

        499

        • A.1 Specifications

          499

        • A.1.1 1-Phase, 200V Class

          499

      • 3-Phase, 400V Class

        500

    • Common Specifications

      501

      • Fr-E720S-008

        501

        • A.2 Common Specifications

          501

        • A.3 Outline Dimension Drawings

          503

        • A.3.1 FR-E720S-008 to 030

          503

      • FR-E720S-050 and 080

        504

        • A.3.2 FR-E720S-050 and 080

          504

        • A.3.3 FR-E720S-110 and FR-E740-016 to 095

          505

      • FR-E740-230 and 300

        506

        • A.3.4 FR-E740-120 and 170

          506

        • A.3.5 FR-E740-230 and 300

          506

      • Parameter Unit FR-PU07

        507

      • Parameter Unit FR-PA07

        508

    • Parameter List with Instruction Codes

      509

Advertisement

Mitsubishi Electric FR-E740 Instruction Manual

Mitsubishi Electric FR-E740 Instruction Manual (48 pages)

Brand: Mitsubishi Electric
|
Category: Inverter
|
Size: 4.22 MB

Table of Contents
  • Table of Contents

    1

  • Product Checking and Parts Identification

    4

  • Installation and Wiring

    5

  • Precautions for Use of the Inverter

    21

  • Failsafe of the System Which Uses the Inverter

    23

  • Parameter List

    24

  • Troubleshooting

    27

  • Precautions for Maintenance and Inspection

    32

  • Specifications

    34

Advertisement

Related Products

  • Mitsubishi Electric FR-E 540 EC

  • Mitsubishi Electric FR-E720S

  • Mitsubishi Electric FR-E800-SCEPA

  • Mitsubishi Electric FR-F740-00380-EC

  • Mitsubishi Electric FR-F740-00083-EC

  • Mitsubishi Electric FR-F520L-90K

  • Mitsubishi Electric FR-F540L-185K

  • Mitsubishi Electric FR-F540L-375K

  • Mitsubishi Electric FR-D720-3.7K-G

  • Mitsubishi Electric FR-D740-0.4K-G

Mitsubishi Electric Categories

Air Conditioner
Air Conditioner

Controller

Projector
Projector

Inverter

Heat Pump

More Mitsubishi Electric Manuals

  1. Manuals
  2. Brands
  3. Mitsubishi Electric Manuals
  4. Inverter
  5. FR-E740-5.5K(SC)

Manuals and User Guides for Mitsubishi Electric FR-E740-5.5K(SC). We have 1 Mitsubishi Electric FR-E740-5.5K(SC) manual available for free PDF download: Instruction Manual

Mitsubishi Electric FR-E740-5.5K(SC) Instruction Manual

Mitsubishi Electric FR-E740-5.5K(SC) Instruction Manual (349 pages)

FR-E700 series

Brand: Mitsubishi Electric
|
Category: Inverter
|
Size: 22.88 MB

Table of Contents
  • Table of Contents

    4

  • 1 Outline

    10

    • Product Checking and Parts Identification

      11

    • Inverter and Peripheral Devices

      12

      • Peripheral Devices

        13

    • Removal and Reinstallation of the Cover

      14

      • Front Cover

        14

      • Wiring

        14

      • Wiring Cover

        16

    • Installation of the Inverter and Enclosure Design

      17

      • Inverter Installation Environment

        17

      • Cooling System Types for Inverter Panel

        19

      • Inverter Placement

        20

  • 2 Wiring

    22

    • Terminal Connection Diagram

      23

      • Main Circuit

        24

      • Control Circuit

        24

    • Main Circuit Terminal Specifications

      25

      • Specification of Main Circuit Terminal

        25

      • Terminal Arrangement of the Main Circuit Terminal, Power Supply and the Motor Wiring

        25

      • Cables and Wiring Length

        27

    • Control Circuit Specifications

      31

      • Control Circuit Terminal

        31

      • Changing the Control Logic

        34

      • Connection of Stand-Alone Option Unit

        35

      • Wiring of Control Circuit

        36

        • Terminal Layout

          37

        • Wiring Method

          37

      • Safety Stop Function (Available Only for the Safety Stop Function Model)

        40

      • Connection to the PU Connector

        42

    • Connection of Stand-Alone Option Unit

      44

      • Connection of a Dedicated External Brake Resistor (MRS Type, MYS Type, FR-ABR) (0.4K(SC) or More)

        44

      • Connection of the Brake Unit (FR-BU2)

        46

      • Connection of the High Power Factor Converter (FR-HC)

        47

      • Connection of the Power Regeneration Common Converter (FR-CV)

        48

      • Connection of the DC Reactor (FR-HEL)

        48

  • 3 Precautions for Use of the Inverter

    50

    • EMC and Leakage Currents

      51

      • Leakage Currents and Countermeasures

        51

      • Inverter-Driven 400V Class Motor

        51

      • EMC Measures

        53

      • Power Supply Harmonics

        55

      • Harmonic Suppression Guideline in Japan

        56

    • Installation of Power Factor Improving Reactor

      58

    • Power-OFF and Magnetic Contactor (MC)

      59

    • Inverter-Driven 400V Class Motor

      60

    • Precautions for Use of the Inverter

      61

    • Failsafe of the System Which Uses the Inverter

      63

  • 4 Parameters

    66

    • Operation Panel

      67

      • Names and Functions of the Operation Panel

        67

      • Basic Operation (Factory Setting)

        68

      • Easy Operation Mode Setting (Easy Setting Mode)

        69

      • Changing the Parameter Setting Value

        70

      • Setting Dial Push

        70

    • Parameter List

      71

      • Parameters According to Purposes

        80

    • Control Mode

      83

      • Changing the Control Method (Pr. 80, Pr. 81, Pr. 800)

        84

    • Adjustment of the Output Torque (Current) of the Motor

      85

      • Manual Torque Boost (Pr. 0, Pr. 46)

        85

      • Advanced Magnetic Flux Vector Control (Pr. 71, Pr. 80, Pr. 81, Pr.89, Pr. 800)

        86

      • General-Purpose Magnetic Flux Vector Control (Pr. 71, Pr. 80, Pr. 81, Pr. 800)

        89

      • Slip Compensation (Pr. 245 to Pr. 247)

        91

      • Stall Prevention Operation (Pr. 22, Pr. 23, Pr. 48, Pr. 66, Pr. 156, Pr. 157, Pr. 277)

        92

    • Limiting the Output Frequency

      96

      • Maximum/Minimum Frequency (Pr. 1, Pr. 2, Pr. 18)

        96

      • Avoiding Mechanical Resonance Points (Frequency Jumps) (Pr. 31 to Pr. 36)

        97

    • V/F Pattern

      98

      • Base Frequency, Voltage (Pr. 3, Pr. 19, Pr. 47)

        98

      • Load Pattern Selection (Pr. 14)

        100

    • Frequency Setting by External Terminals

      102

      • Operation by Multi-Speed Operation (Pr. 4 to Pr. 6, Pr. 24 to Pr. 27, Pr. 232 to Pr. 239)

        102

      • Jog Operation (Pr. 15, Pr. 16)

        104

      • Remote Setting Function (Pr. 59)

        106

    • Setting of Acceleration/Deceleration Time and Acceleration/ Deceleration Pattern

      109

      • Setting of the Acceleration and Deceleration Time (Pr. 7, Pr. 8, Pr. 20, Pr. 21, Pr. 44, Pr. 45, Pr. 147)

        109

      • Starting Frequency and Start-Time Hold Function (Pr. 13, Pr. 571)

        112

      • Acceleration/Deceleration Pattern (Pr. 29)

        113

      • Shortest Acceleration/Deceleration (Automatic Acceleration/Deceleration) (Pr. 61 to Pr. 63, Pr. 292, Pr. 293)

        114

    • Selection and Protection of a Motor

      116

      • Motor Overheat Protection (Electronic Thermal O/L Relay) (Pr. 9, Pr. 51)

        116

      • Applied Motor (Pr. 71, Pr. 450)

        118

      • Exhibiting the Best Performance for the Motor (Offline Auto Tuning) (Pr. 71, Pr. 80 to Pr. 84, Pr. 90 to Pr. 94, Pr. 96, Pr. 859)

        120

    • Motor Brake and Stop Operation

      128

      • DC Injection Brake (Pr. 10 to Pr. 12)

        128

      • Selection of a Regenerative Brake (Pr. 30, Pr. 70)

        130

      • Stop Selection (Pr. 250)

        132

      • Stop-On Contact Control Function (Pr. 6, Pr. 48, Pr. 270, Pr. 275, Pr. 276)

        133

      • Brake Sequence Function (Pr. 278 to Pr. 283, Pr. 292)

        135

    • Function Assignment of External Terminal and Control

      139

      • Input Terminal Function Selection (Pr. 178 to Pr. 184)

        139

      • Inverter Output Shutoff Signal (MRS Signal, Pr. 17)

        141

      • Condition Selection of Function Validity by Second Function Selection Signal (RT)

        142

      • Start Signal Operation Selection (STF, STR, STOP Signal, Pr. 250)

        143

      • Output Terminal Function Selection (Pr. 190 to Pr. 192)

        145

      • Detection of Output Frequency (SU, FU Signal, Pr. 41 to Pr. 43)

        149

      • Output Current Detection Function (Y12 Signal, Y13 Signal, Pr. 150 to Pr. 153)

        150

      • Remote Output Selection (REM Signal, Pr. 495 to Pr. 497)

        152

    • Monitor Display and Monitor Output Signal

      153

      • Speed Display and Speed Setting (Pr. 37)

        153

      • Monitor Display Selection of DU/PU and Terminal FM (Pr. 52, Pr. 54, Pr. 170, Pr. 171, Pr. 268, Pr. 563, Pr. 564)

        154

      • Reference of the Terminal FM (Pulse Train Output) (Pr. 55, Pr. 56)

        159

      • Terminal FM Calibration (Calibration Parameter C0 (Pr. 900))

        160

    • Operation Selection at Power Failure and Instantaneous Power Failure

      162

      • Automatic Restart after Instantaneous Power Failure/Flying Start (Pr. 30, Pr. 57, Pr. 58, Pr. 96, Pr. 162, Pr. 165, Pr. 298, Pr. 299, Pr. 611)

        162

      • Power-Failure Deceleration Stop Function (Pr. 261)

        168

    • Operation Setting at Fault Occurrence

      170

    • Retry Function (Pr. 65, Pr. 67 to Pr. 69)

      170

    • Input/Output Phase Loss Protection Selection (Pr. 251, Pr. 872)

      172

    • Earth (Ground) Fault Detection at Start (Pr. 249)

      172

    • Energy Saving Operation

      173

      • Optimum Excitation Control (Pr. 60)

        173

    • Motor Noise, EMI Measures, Mechanical Resonance

      174

      • PWM Carrier Frequency and Soft-PWM Control (Pr. 72, Pr. 240)

        174

      • Speed Smoothing Control (Pr. 653)

        175

    • Frequency Setting by Analog Input (Terminal 2, 4)

      176

      • Analog Input Selection (Pr. 73, Pr. 267)

        176

      • Response Level of Analog Input and Noise Elimination (Pr. 74)

        178

      • Bias and Gain of Frequency Setting Voltage (Current) (Pr. 125, Pr. 126, Pr. 241, C2 (Pr. 902) to C7 (Pr. 905))

        179

    • Misoperation Prevention and Parameter Setting Restriction

      184

      • Reset Selection/Disconnected PU Detection/Pu Stop Selection (Pr. 75)

        184

      • Parameter Write Disable Selection (Pr. 77)

        184

      • Parameter Write Disable Selection (Pr. 77)

        187

      • Reverse Rotation Prevention Selection (Pr. 78)

        188

      • Extended Parameter Display and User Group Function (Pr. 160, Pr. 172 to Pr. 174)

        188

      • Operation Display

        190

      • Password Function (Pr. 296, Pr. 297)

        191

    • Selection of Operation Mode and Operation Location

      194

      • Operation Mode Selection (Pr. 79)

        194

      • Operation Mode at Power-ON (Pr. 79, Pr. 340)

        204

      • Start Command Source and Frequency Command Source During Communication Operation (Pr. 338, Pr. 339, Pr. 550, Pr. 551)

        205

    • Communication Operation and Setting

      211

      • Wiring and Configuration of PU Connector

        211

      • Initial Settings and Specifications of RS-485 Communication (Pr. 117 to Pr. 120, Pr. 123, Pr. 124, Pr. 549)

        214

      • Operation Selection at Communication Error Occurrence (Pr. 121, Pr. 122, Pr. 502)

        215

      • Communication EEPROM Write Selection (Pr. 342)

        218

      • Mitsubishi Inverter Protocol (Computer Link Communication)

        219

      • Run Command

        230

      • Modbus-RTU Communication Specifications (Pr. 117, Pr. 118, Pr. 120, Pr. 122, Pr. 343, Pr. 502, Pr. 549)

        232

      • Modbus-RTU Communication Specifications

        232

      • USB Communication (Pr. 547, Pr. 548)

        245

    • Special Operation and Frequency Control

      246

      • PID Control (Pr. 127 to Pr. 134)

        246

      • Dancer Control (Pr. 44, Pr. 45, Pr. 128 to Pr. 134)

        253

      • Droop Control (Pr. 286 to Pr. 287)

        260

      • Regeneration Avoidance Function (Pr. 665, Pr. 882, Pr. 883, Pr. 885, Pr. 886)

        261

    • Useful Functions

      263

      • Cooling Fan Operation Selection (Pr. 244)

        263

      • Display of the Life of the Inverter Parts (Pr. 255 to Pr. 259)

        264

      • Maintenance Timer Alarm (Pr. 503, Pr. 504)

        268

      • Current Average Value Monitor Signal (Pr. 555 to Pr. 557)

        269

      • Free Parameter (Pr. 888, Pr. 889)

        271

      • Setting from the Parameter Unit and Operation Panel

        272

        • RUN Key Rotation Direction Selection (Pr. 40)

          272

        • PU Display Language Selection(Pr.145)

          272

        • Operation Panel Frequency Setting/Key Lock Operation Selection (Pr. 161)

          273

        • Magnitude of Frequency Change Setting (Pr. 295)

          275

        • Buzzer Control (Pr. 990)

          276

        • PU Contrast Adjustment (Pr. 991)

          276

      • FR-E500 Series Operation Panel (PA02) Setting

        277

        • Built-In Potentiometer Switching (Pr. 146)

          277

        • Bias and Gain of the Built-In Frequency Setting Potentiometer (C22 (Pr. 922) to C25 (Pr. 923))

          278

      • Parameter Clear/ All Parameter Clear

        284

      • Initial Value Change List

        285

      • Check and Clear of the Faults History

        286

  • 5 Troubleshooting

    289

    • Reset Method of Protective Function

      290

    • List of Fault or Alarm Indications

      291

    • Causes and Corrective Actions

      292

    • Correspondences between Digital and Actual Characters

      302

    • Check First When You Have a Trouble

      303

      • Motor Does Not Start

        303

      • Motor or Machine Is Making Abnormal Acoustic Noise

        305

      • Inverter Generates Abnormal Noise

        305

      • Motor Generates Heat Abnormally

        305

      • Motor Rotates in the Opposite Direction

        306

      • Speed Greatly Differs from the Setting

        306

      • Acceleration/Deceleration Is Not Smooth

        306

      • Speed Varies During Operation

        307

      • Operation Mode Is Not Changed Properly

        307

      • Operation Panel Display Is Not Operating

        308

      • Motor Current Is too Large

        308

      • Speed Does Not Accelerate

        309

      • Unable to Write Parameter Setting

        309

  • 6 Precautions for Maintenance and Inspection

    312

    • Inspection Items

      312

      • Daily Inspection

        312

      • Periodic Inspection

        312

      • Daily and Periodic Inspection

        313

      • Display of the Life of the Inverter Parts

        314

      • Checking the Inverter and Converter Modules

        315

      • Cleaning

        316

      • Replacement of Parts

        316

      • Inverter Replacement

        319

    • Measurement of Main Circuit Voltages, Currents and Powers

      320

      • Measurement of Powers

        322

      • Measurement of Voltages and Use of PT

        322

      • Measurement of Currents

        323

      • Use of CT and Transducer

        323

      • Measurement of Inverter Input Power Factor

        323

      • Measurement of Converter Output Voltage (Across Terminals P/+ and N/-)

        323

      • Measurement of Inverter Output Frequency

        323

      • Insulation Resistance Test Using Megger

        324

      • Pressure Test

        324

  • 7 Specifications

    325

    • Rating

      326

    • Common Specifications

      328

    • Outline Dimension Drawings

      329

  • Appendix

    335

    • Appendix 1 for Customers Who Are Replacing the Conventional Model with this Inverter

      336

    • Appendix 1-1 Replacement of the FR-E500 Series

      336

    • Appendix 2 Specification Change

      338

    • Appendix 2-1 SERIAL Number Check

      338

    • Appendix 2-2 Changed Functions

      338

    • Appendix3 Index

      341

Advertisement

Advertisement

Related Products

  • Mitsubishi Electric FR-E740-5.5K

  • Mitsubishi Electric FR-E740-5.5KNF

  • Mitsubishi Electric FR-E740EC

  • Mitsubishi Electric FR-E740-1.5K(SC)

  • Mitsubishi Electric FR-E740-3.7K(SC)

  • Mitsubishi Electric FR-E740-15K-NE

  • Mitsubishi Electric FR-E740-3.7K-NE

  • Mitsubishi Electric FR-E740-230

  • Mitsubishi Electric FR-E740-300SC

  • Mitsubishi Electric FR-E740-0.4KNF

Mitsubishi Electric Categories

Air Conditioner
Air Conditioner

Controller

Projector
Projector

Inverter

Heat Pump

More Mitsubishi Electric Manuals

FR-E700

INSTRUCTION MANUAL (BASIC)

FR-E720-0.1K to 15K

FR-E740-0.4K to 15K

FR-E720S-0.1K to 2.2K

FR-E710W-0.1K to 0.75K

INVERTER

5

6

7

8

9

10

4

3

2

1

CONTENTS

Thank you for choosing this Mitsubishi Inverter.
This Instruction Manual (Basic) provides handling information and precautions for use of the equipment.
Please forward this Instruction Manual (Basic) to the end user.

To obtain the Instruction Manual (Applied)

Contact where you purchased the inverter, your Mitsubishi sales
representative, or the nearest Mitsubishi FA Center for the following
manual:
Instruction Manual (Applied) [IB(NA)-0600277ENG]
This manual is required if you are going to utilize functions and
performance.
The PDF version of this manual is also available for download at
«MELFANS Web,» the Mitsubishi Electric FA network service on the
world wide web (URL: http://www.MitsubishiElectric.co.jp/melfansweb).

Понравилась статья? Поделить с друзьями:
  • Инструкция капель зодак для детей от аллергии
  • Сигнализация ягуар tez b инструкция по эксплуатации автозапуск
  • Классное руководство событие
  • Микокет мазь инструкция по применению цена отзывы
  • Международная алюминиевая компания руководство