- Manuals
- Brands
- Mitsubishi Electric Manuals
- DC Drives
- FR-E740
Manuals and User Guides for Mitsubishi Electric FR-E740. We have 2 Mitsubishi Electric FR-E740 manuals available for free PDF download: Instruction Manual
Mitsubishi Electric FR-E740 Instruction Manual (524 pages)
Frequency Inverter
Brand: Mitsubishi Electric
|
Category: DC Drives
|
Size: 15.31 MB
Table of Contents
-
Instruction Manual
1
-
Safety Instructions
5
-
Table of Contents
11
-
1 Product Checking and Part Identification
19
-
Inverter Type
19
-
Description of the Case
20
-
Accessory
21
-
-
-
2 Installation
23
-
Removal and Reinstallation of the Front Cover
23
-
FR-E720S and FR-E740-016 to FR-E740-170
23
-
FR-E740-230 and FR-E740-300
24
-
-
Removal and Reinstallation of the Wiring Cover
26
-
Mounting
27
-
Enclosure Design
29
-
Inverter Installation Environment
29
-
Inverter Placement
33
-
-
-
3 Wiring
35
-
Inverter and Peripheral Devices
35
-
Peripheral Devices
37
-
-
Terminal Connection Diagramm
38
-
Main Circuit Connection
40
-
Specification of Main Circuit Terminal
40
-
Terminal Layout and Wiring
41
-
-
Control Circuit Specifications
48
-
Control Circuit Terminals
51
-
Wiring Instructions
53
-
Changing the Control Logic
54
-
-
PU Connector
57
-
Connecting the Operation Panel Using a Connection Cable
57
-
RS485 Communication
58
-
-
USB Connector
59
-
Connection of Stand-Alone Option Units
60
-
Magnetic Contactors (MC)
60
-
Connection of a Dedicated External Brake Resistor FR-ABR and MRS (FR-E720S-030 or More, FR-E740-016 or More)
62
-
Connection of a Brake Unit FR-BU2
66
-
Connection of the High Power Factor Converter FR-HC
69
-
Connection of the Power Regeneration Common Converter FR-CV
70
-
Connection of the Power Improving DC Reactor FR-HEL
71
-
Installation of a Reactor
71
-
-
Electromagnetic Compatibility (EMC)
72
-
Leakage Currents and Countermeasures
72
-
Inverter-Generated Noises and Their Reduction Techniques
76
-
Power Supply Harmonics
79
-
Inverter-Driven 400V Class Motor
80
-
-
-
4 Operation
81
-
Precautions for Use of the Inverter
81
-
Failsafe of the System Which Uses the Inverter
83
-
-
Drive the Motor
86
-
Operation Panel
87
-
Parts of the Operation Panel
87
-
Basic Operation (Factory Setting)
89
-
Easy Operation Mode Setting (Easy Setting Mode)
90
-
Operation Lock
92
-
Monitoring of Output Current and Output Voltage
94
-
First Priority Monitor
94
-
Digital Dial Push
94
-
Change the Parameter Setting Value
95
-
Parameter Clear/All Parameter Clear
96
-
Initial Value Change List
97
-
-
-
5 Basic Settings
99
-
Simple Mode Parameter List
99
-
Overheat Protection of the Motor by the Inverter
100
-
When the Rated Motor Frequency Is 60Hz (Pr. 3)
102
-
Increase the Starting Torque (Pr. 0)
103
-
Limit the Maximum and Minimum Output Frequency (Pr. 1, Pr. 2)
105
-
Change the Acceleration/Deceleration Time (Pr. 7, Pr.
107
-
Operation Mode (Pr. 79)
109
-
Large Starting Torque and Low Speed Torque Are Necessary (Advance Magnetic Flux Control, General-Purpose Magnetic Flux Vector Control) (Pr. 71, Pr. 80, Pr. 81, Pr. 800)
110
-
To Exhibit the Best Performance of the Motor Performance (Offline Auto Tuning) (Pr. 9, Pr. 71, Pr. 83, Pr. 84, Pr. 96)
113
-
-
PU Operation Mode
118
-
Set the Set Frequency to Operate
119
-
Use the Digital Dial Like a Potentiometer to Perform Operation
121
-
Use Switches to Give the Frequency Command (Multi-Speed Setting)
122
-
Perform Frequency Setting by Analog Voltage Input
124
-
Perform Frequency Setting by Analog Current Input
126
-
-
External Operation
128
-
Use the Set Frequency Set by the Operation Panel (Pr. 79 = 3)
128
-
Use Switches to Give a Start Command and a Frequency Command (Multi-Speed Setting) (Pr. 4 to Pr. 6)
130
-
Perform Frequency Setting by Analog Voltage Input
133
-
Change the Frequency (40Hz) of the Maximum Value of Potentiometer (at 5V)
136
-
Perform Frequency Setting by Analog Current Input
137
-
Change the Frequency (40Hz) of the Maximum Value of Potentiometer (at 20Ma)
139
-
-
-
6 Parameter
141
-
Parameter Overview
141
-
Control Mode
170
-
Change the Control Method (Pr. 80, Pr. 81, Pr. 800)
171
-
-
Adjust the Output Torque (Current) of the Motor
181
-
Slip Compensation (Pr. 245 to Pr. 247)
181
-
Stall Prevention
182
-
Torque Limit
182
-
-
Limit the Output Frequency
190
-
Maximum and Minimum Frequency (Pr. 1, Pr. 2, Pr. 18)
190
-
Avoid Mechanical Resonance Points (Frequency Jumps)
192
-
-
Set V/F Pattern
194
-
Base Frequency, Voltage (Pr. 3, Pr. 19, Pr. 47)
194
-
Load Pattern Selection (Pr. 14)
196
-
-
Frequency Setting by External Terminals
198
-
(Pr. 4 to Pr. 6, Pr. 24 to Pr. 27, Pr. 232 to Pr. 239)
198
-
Jog Operation (Pr. 15, Pr. 16)
201
-
Remote Setting Function (Pr. 28)
205
-
-
Acceleration and Deceleration
209
-
Acceleration and Deceleration Time (Pr. 7, Pr. 8, Pr. 20, Pr. 21, Pr. 44, Pr. 45, Pr. 147)
209
-
Starting Frequency and Start-Time Hold Function
213
-
Acceleration and Deceleration Pattern (Pr. 29, Pr. 140 to Pr. 143)
215
-
(Automatic Acceleration/Deceleration)
217
-
(Pr. 61 to Pr. 63, Pr. 292, Pr. 293)
217
-
-
-
Selection and Protection of a Motor
220
-
Motor Overheat Protection (Electronic Thermal O/L Relay)
220
-
Applied Motor (Pr. 71, Pr. 450)
225
-
To Exhibit the Best Performance of the Motor Performance
228
-
-
Motor Brake and Stop Operation
238
-
DC Injection Brake (Pr. 10 to Pr. 12)
238
-
Selection of a Regenerative Brake (Pr. 30, Pr. 70)
241
-
Stop Selection (Pr. 250)
243
-
Brake Sequence Function (Pr. 278 to Pr. 283, Pr. 292)
249
-
-
Function Assignment of External Terminals
254
-
Input Terminal Function Selection (Pr. 178 to Pr. 184)
254
-
Inverter Output Shutoff Signal (MRS Signal, Pr. 17)
257
-
Condition Selection of Function Validity by Second
259
-
Function Selection Signal (RT, Pr. 155)
259
-
-
Start Signal Selection (Terminal STF, STR, STOP, Pr. 250)
260
-
Output Terminal Function Selection (Pr. 190 to Pr. 192)
264
-
Detection of Output Frequency (SU, FU, Pr. 41 to Pr. 43)
269
-
Output Current Detection Function (Y12, Y13, Pr. 150 to Pr. 153)
271
-
Remote Output Function (REM, Pr. 495 to Pr. 497)
273
-
-
Monitor Display and Monitor Output Signals
276
-
Speed Display and Speed Setting (Pr. 37)
276
-
Monitor Display Selection of DU/PU and Terminal am (Pr. 52, Pr. 158, Pr. 170, Pr. 171, Pr. 268, Pr. 563, Pr. 564)
278
-
Reference of the Terminal am (Analog Voltage Output)
286
-
Terminal am Calibration
288
-
-
Operation Selection at Power Failure
291
-
Automatic Restart (Pr. 30, Pr. 57, Pr. 58, Pr. 96, Pr. 162, Pr. 165, Pr. 298, Pr. 299, Pr. 611)
291
-
Power Failure-Time Deceleration-To-Stop Function (Pr. 261)
302
-
-
Operation Setting at Alarm Occurrence
306
-
Retry Function (Pr. 65, Pr. 67 to Pr. 69)
306
-
Input/Output Phase Failure Protection Selection (Pr. 251, Pr. 872)
309
-
Earth (Ground) Fault Detection at Start (Pr. 249)
310
-
-
Energy Saving Operation
311
-
Optimum Excitation Control (Pr. 60)
311
-
-
Motor Noise, EMI Measures, Mechanical Resonance
312
-
PWM Carrier Frequency and Soft-PWM Control (Pr. 72, Pr. 240)
312
-
Speed Smoothing Control (Pr. 653)
313
-
-
Frequency Setting by Analog Input (Terminal 2, 4)
314
-
Analog Input Selection (Pr. 73, Pr. 267)
314
-
Input Filter Time Constant (Pr. 74)
319
-
Bias and Gain of Frequency Setting Voltage (Current) [Pr. 125, Pr. 126, Pr. 241, C2 (Pr. 902) to C7 (Pr. 905)]
320
-
-
Misoperation Prevention and Parameter Setting Restriction
327
-
Reset Selection/Disconnected PU Detection/Pu Stop Selection
327
-
Parameter Write Selection (Pr. 77)
332
-
Reverse Rotation Prevention Selection (Pr. 78)
334
-
User Groups (Pr. 160, Pr. 172 to Pr. 174)
335
-
-
Selection of Operation Mode and Operation Location
338
-
Operation Mode Selection (Pr. 79)
338
-
Operation Mode at Power on (Pr. 79, Pr. 340)
350
-
Start Command Source and Frequency Command Source During Communication Operation (Pr. 338, Pr. 339, Pr. 550, Pr. 551)
352
-
-
Communication Operation and Setting
361
-
PU Connector
361
-
Initial Settings and Specifications of RS-485 Communication
366
-
Communication E²PROM Write Selection (Pr. 342)
372
-
Mitsubishi Inverter Protocol (Computer Link Communication)
373
-
Error Code
379
-
Modbus-RTU Communication (Pr. 117, Pr. 118, Pr. 120, Pr. 122, Pr. 343, Pr. 549)
391
-
USB Communication (Pr. 547, Pr. 548)
409
-
-
Special Operation
410
-
PID Control (Pr. 127 to Pr. 134)
410
-
Dancer Control (Pr. 44, Pr. 45, Pr. 128 to Pr. 134)
422
-
Droop Control (Pr. 286 to Pr. 287)
431
-
Regeneration Avoidance Function (Pr. 665, Pr. 882, Pr. 883, Pr. 885, Pr. 886)
432
-
-
Useful Functions
435
-
Cooling Fan Operation Selection (Pr. 244)
435
-
Display of the Life of the Inverter Parts (Pr. 255 to Pr. 259)
436
-
Maintenance Timer Alarm (Pr. 503, Pr. 504)
440
-
Current Average Value Monitor Signal (Pr. 555 to Pr. 557)
441
-
Free Parameters (Pr. 888, Pr. 889)
445
-
-
Setting for the Parameter Unit, Operation Panel
446
-
RUN Key Rotation Direction Selection (Pr. 40)
446
-
PU Display Language Selection (Pr. 145)
446
-
Operation Panel Frequency Setting/Key Lock Operation Selection
447
-
Magnitude of Frequency Change Setting (Pr. 295)
448
-
Buzzer Control (Pr. 990)
449
-
PU Contrast Adjustment (Pr. 991)
449
-
-
-
7 Troubleshooting
451
-
List of Alarm Display
452
-
Causes and Corrective Actions
454
-
Reset Method of Protective Function
466
-
LED Display
467
-
Check and Clear of the Fault History
468
-
Check First When You Have Troubles
470
-
Motor Does Not Start
470
-
Motor or Machine Generates Abnormal Noise
472
-
Inverter Generates Abnormal Noise
472
-
Motor Generates Heat Abnormally
473
-
Motor Rotates in Opposite Direction
473
-
Speed Greatly Differs from the Setting
473
-
Acceleration/Deceleration Is Not Smooth
474
-
Speed Varies During Operation
475
-
Operation Mode Is Not Changed Properly
476
-
Operation Panel Display Is Not Operating
476
-
Motor Current Is too Large
477
-
Speed Does Not Accelerate
478
-
Unable to Write Parameter Setting
479
-
-
Meters and Measuring Methods
480
-
Measurement of Powers
481
-
Measurement of Voltages and Use of PT
482
-
Measurement of Currents
482
-
Use of CT and Transducer
483
-
Measurement of Inverter Input Power Factor
483
-
Measurement of Converter Output Voltage (Across Terminals + and -)
483
-
-
-
8 Maintenance and Inspection
485
-
Inspection
485
-
Daily Inspection
485
-
Periodic Inspection
485
-
Daily and Periodic Inspection
486
-
Display of the Life of the Inverter Parts
488
-
Checking the Inverter and Converter Modules
489
-
Cleaning
490
-
Replacement of Parts
490
-
Inverter Replacement
494
-
-
Measurements on the Main Circuit
495
-
Insulation Resistance Test Using Megger
495
-
Pressure Test
495
-
Measurement of Voltages and Currents
496
-
-
-
Appendix
499
-
Specifications
499
-
1-Phase, 200V Class
499
-
A.1 Specifications
499
-
A.1.1 1-Phase, 200V Class
499
-
-
3-Phase, 400V Class
500
-
-
Common Specifications
501
-
Fr-E720S-008
501
-
A.2 Common Specifications
501
-
A.3 Outline Dimension Drawings
503
-
A.3.1 FR-E720S-008 to 030
503
-
-
FR-E720S-050 and 080
504
-
A.3.2 FR-E720S-050 and 080
504
-
A.3.3 FR-E720S-110 and FR-E740-016 to 095
505
-
-
FR-E740-230 and 300
506
-
A.3.4 FR-E740-120 and 170
506
-
A.3.5 FR-E740-230 and 300
506
-
-
Parameter Unit FR-PU07
507
-
Parameter Unit FR-PA07
508
-
-
Parameter List with Instruction Codes
509
-
Advertisement
Mitsubishi Electric FR-E740 Instruction Manual (48 pages)
Brand: Mitsubishi Electric
|
Category: Inverter
|
Size: 4.22 MB
Table of Contents
-
Table of Contents
1
-
Product Checking and Parts Identification
4
-
Installation and Wiring
5
-
Precautions for Use of the Inverter
21
-
Failsafe of the System Which Uses the Inverter
23
-
Parameter List
24
-
Troubleshooting
27
-
Precautions for Maintenance and Inspection
32
-
Specifications
34
Advertisement
Related Products
-
Mitsubishi Electric FR-E 540 EC
-
Mitsubishi Electric FR-E720S
-
Mitsubishi Electric FR-E800-SCEPA
-
Mitsubishi Electric FR-F740-00380-EC
-
Mitsubishi Electric FR-F740-00083-EC
-
Mitsubishi Electric FR-F520L-90K
-
Mitsubishi Electric FR-F540L-185K
-
Mitsubishi Electric FR-F540L-375K
-
Mitsubishi Electric FR-D720-3.7K-G
-
Mitsubishi Electric FR-D740-0.4K-G
Mitsubishi Electric Categories
Air Conditioner
Controller
Projector
Inverter
Heat Pump
More Mitsubishi Electric Manuals
- Manuals
- Brands
- Mitsubishi Electric Manuals
- Inverter
- FR-E740-5.5K(SC)
Manuals and User Guides for Mitsubishi Electric FR-E740-5.5K(SC). We have 1 Mitsubishi Electric FR-E740-5.5K(SC) manual available for free PDF download: Instruction Manual
Mitsubishi Electric FR-E740-5.5K(SC) Instruction Manual (349 pages)
FR-E700 series
Brand: Mitsubishi Electric
|
Category: Inverter
|
Size: 22.88 MB
Table of Contents
-
Table of Contents
4
-
1 Outline
10
-
Product Checking and Parts Identification
11
-
Inverter and Peripheral Devices
12
-
Peripheral Devices
13
-
-
Removal and Reinstallation of the Cover
14
-
Front Cover
14
-
Wiring
14
-
Wiring Cover
16
-
-
Installation of the Inverter and Enclosure Design
17
-
Inverter Installation Environment
17
-
Cooling System Types for Inverter Panel
19
-
Inverter Placement
20
-
-
-
2 Wiring
22
-
Terminal Connection Diagram
23
-
Main Circuit
24
-
Control Circuit
24
-
-
Main Circuit Terminal Specifications
25
-
Specification of Main Circuit Terminal
25
-
Terminal Arrangement of the Main Circuit Terminal, Power Supply and the Motor Wiring
25
-
Cables and Wiring Length
27
-
-
Control Circuit Specifications
31
-
Control Circuit Terminal
31
-
Changing the Control Logic
34
-
Connection of Stand-Alone Option Unit
35
-
Wiring of Control Circuit
36
-
Terminal Layout
37
-
Wiring Method
37
-
-
Safety Stop Function (Available Only for the Safety Stop Function Model)
40
-
Connection to the PU Connector
42
-
-
Connection of Stand-Alone Option Unit
44
-
Connection of a Dedicated External Brake Resistor (MRS Type, MYS Type, FR-ABR) (0.4K(SC) or More)
44
-
Connection of the Brake Unit (FR-BU2)
46
-
Connection of the High Power Factor Converter (FR-HC)
47
-
Connection of the Power Regeneration Common Converter (FR-CV)
48
-
Connection of the DC Reactor (FR-HEL)
48
-
-
-
3 Precautions for Use of the Inverter
50
-
EMC and Leakage Currents
51
-
Leakage Currents and Countermeasures
51
-
Inverter-Driven 400V Class Motor
51
-
EMC Measures
53
-
Power Supply Harmonics
55
-
Harmonic Suppression Guideline in Japan
56
-
-
Installation of Power Factor Improving Reactor
58
-
Power-OFF and Magnetic Contactor (MC)
59
-
Inverter-Driven 400V Class Motor
60
-
Precautions for Use of the Inverter
61
-
Failsafe of the System Which Uses the Inverter
63
-
-
4 Parameters
66
-
Operation Panel
67
-
Names and Functions of the Operation Panel
67
-
Basic Operation (Factory Setting)
68
-
Easy Operation Mode Setting (Easy Setting Mode)
69
-
Changing the Parameter Setting Value
70
-
Setting Dial Push
70
-
-
Parameter List
71
-
Parameters According to Purposes
80
-
-
Control Mode
83
-
Changing the Control Method (Pr. 80, Pr. 81, Pr. 800)
84
-
-
Adjustment of the Output Torque (Current) of the Motor
85
-
Manual Torque Boost (Pr. 0, Pr. 46)
85
-
Advanced Magnetic Flux Vector Control (Pr. 71, Pr. 80, Pr. 81, Pr.89, Pr. 800)
86
-
General-Purpose Magnetic Flux Vector Control (Pr. 71, Pr. 80, Pr. 81, Pr. 800)
89
-
Slip Compensation (Pr. 245 to Pr. 247)
91
-
Stall Prevention Operation (Pr. 22, Pr. 23, Pr. 48, Pr. 66, Pr. 156, Pr. 157, Pr. 277)
92
-
-
Limiting the Output Frequency
96
-
Maximum/Minimum Frequency (Pr. 1, Pr. 2, Pr. 18)
96
-
Avoiding Mechanical Resonance Points (Frequency Jumps) (Pr. 31 to Pr. 36)
97
-
-
V/F Pattern
98
-
Base Frequency, Voltage (Pr. 3, Pr. 19, Pr. 47)
98
-
Load Pattern Selection (Pr. 14)
100
-
-
Frequency Setting by External Terminals
102
-
Operation by Multi-Speed Operation (Pr. 4 to Pr. 6, Pr. 24 to Pr. 27, Pr. 232 to Pr. 239)
102
-
Jog Operation (Pr. 15, Pr. 16)
104
-
Remote Setting Function (Pr. 59)
106
-
-
Setting of Acceleration/Deceleration Time and Acceleration/ Deceleration Pattern
109
-
Setting of the Acceleration and Deceleration Time (Pr. 7, Pr. 8, Pr. 20, Pr. 21, Pr. 44, Pr. 45, Pr. 147)
109
-
Starting Frequency and Start-Time Hold Function (Pr. 13, Pr. 571)
112
-
Acceleration/Deceleration Pattern (Pr. 29)
113
-
Shortest Acceleration/Deceleration (Automatic Acceleration/Deceleration) (Pr. 61 to Pr. 63, Pr. 292, Pr. 293)
114
-
-
Selection and Protection of a Motor
116
-
Motor Overheat Protection (Electronic Thermal O/L Relay) (Pr. 9, Pr. 51)
116
-
Applied Motor (Pr. 71, Pr. 450)
118
-
Exhibiting the Best Performance for the Motor (Offline Auto Tuning) (Pr. 71, Pr. 80 to Pr. 84, Pr. 90 to Pr. 94, Pr. 96, Pr. 859)
120
-
-
Motor Brake and Stop Operation
128
-
DC Injection Brake (Pr. 10 to Pr. 12)
128
-
Selection of a Regenerative Brake (Pr. 30, Pr. 70)
130
-
Stop Selection (Pr. 250)
132
-
Stop-On Contact Control Function (Pr. 6, Pr. 48, Pr. 270, Pr. 275, Pr. 276)
133
-
Brake Sequence Function (Pr. 278 to Pr. 283, Pr. 292)
135
-
-
Function Assignment of External Terminal and Control
139
-
Input Terminal Function Selection (Pr. 178 to Pr. 184)
139
-
Inverter Output Shutoff Signal (MRS Signal, Pr. 17)
141
-
Condition Selection of Function Validity by Second Function Selection Signal (RT)
142
-
Start Signal Operation Selection (STF, STR, STOP Signal, Pr. 250)
143
-
Output Terminal Function Selection (Pr. 190 to Pr. 192)
145
-
Detection of Output Frequency (SU, FU Signal, Pr. 41 to Pr. 43)
149
-
Output Current Detection Function (Y12 Signal, Y13 Signal, Pr. 150 to Pr. 153)
150
-
Remote Output Selection (REM Signal, Pr. 495 to Pr. 497)
152
-
-
Monitor Display and Monitor Output Signal
153
-
Speed Display and Speed Setting (Pr. 37)
153
-
Monitor Display Selection of DU/PU and Terminal FM (Pr. 52, Pr. 54, Pr. 170, Pr. 171, Pr. 268, Pr. 563, Pr. 564)
154
-
Reference of the Terminal FM (Pulse Train Output) (Pr. 55, Pr. 56)
159
-
Terminal FM Calibration (Calibration Parameter C0 (Pr. 900))
160
-
-
Operation Selection at Power Failure and Instantaneous Power Failure
162
-
Automatic Restart after Instantaneous Power Failure/Flying Start (Pr. 30, Pr. 57, Pr. 58, Pr. 96, Pr. 162, Pr. 165, Pr. 298, Pr. 299, Pr. 611)
162
-
Power-Failure Deceleration Stop Function (Pr. 261)
168
-
-
Operation Setting at Fault Occurrence
170
-
Retry Function (Pr. 65, Pr. 67 to Pr. 69)
170
-
Input/Output Phase Loss Protection Selection (Pr. 251, Pr. 872)
172
-
Earth (Ground) Fault Detection at Start (Pr. 249)
172
-
Energy Saving Operation
173
-
Optimum Excitation Control (Pr. 60)
173
-
-
Motor Noise, EMI Measures, Mechanical Resonance
174
-
PWM Carrier Frequency and Soft-PWM Control (Pr. 72, Pr. 240)
174
-
Speed Smoothing Control (Pr. 653)
175
-
-
Frequency Setting by Analog Input (Terminal 2, 4)
176
-
Analog Input Selection (Pr. 73, Pr. 267)
176
-
Response Level of Analog Input and Noise Elimination (Pr. 74)
178
-
Bias and Gain of Frequency Setting Voltage (Current) (Pr. 125, Pr. 126, Pr. 241, C2 (Pr. 902) to C7 (Pr. 905))
179
-
-
Misoperation Prevention and Parameter Setting Restriction
184
-
Reset Selection/Disconnected PU Detection/Pu Stop Selection (Pr. 75)
184
-
Parameter Write Disable Selection (Pr. 77)
184
-
Parameter Write Disable Selection (Pr. 77)
187
-
Reverse Rotation Prevention Selection (Pr. 78)
188
-
Extended Parameter Display and User Group Function (Pr. 160, Pr. 172 to Pr. 174)
188
-
Operation Display
190
-
Password Function (Pr. 296, Pr. 297)
191
-
-
Selection of Operation Mode and Operation Location
194
-
Operation Mode Selection (Pr. 79)
194
-
Operation Mode at Power-ON (Pr. 79, Pr. 340)
204
-
Start Command Source and Frequency Command Source During Communication Operation (Pr. 338, Pr. 339, Pr. 550, Pr. 551)
205
-
-
Communication Operation and Setting
211
-
Wiring and Configuration of PU Connector
211
-
Initial Settings and Specifications of RS-485 Communication (Pr. 117 to Pr. 120, Pr. 123, Pr. 124, Pr. 549)
214
-
Operation Selection at Communication Error Occurrence (Pr. 121, Pr. 122, Pr. 502)
215
-
Communication EEPROM Write Selection (Pr. 342)
218
-
Mitsubishi Inverter Protocol (Computer Link Communication)
219
-
Run Command
230
-
Modbus-RTU Communication Specifications (Pr. 117, Pr. 118, Pr. 120, Pr. 122, Pr. 343, Pr. 502, Pr. 549)
232
-
Modbus-RTU Communication Specifications
232
-
USB Communication (Pr. 547, Pr. 548)
245
-
-
Special Operation and Frequency Control
246
-
PID Control (Pr. 127 to Pr. 134)
246
-
Dancer Control (Pr. 44, Pr. 45, Pr. 128 to Pr. 134)
253
-
Droop Control (Pr. 286 to Pr. 287)
260
-
Regeneration Avoidance Function (Pr. 665, Pr. 882, Pr. 883, Pr. 885, Pr. 886)
261
-
-
Useful Functions
263
-
Cooling Fan Operation Selection (Pr. 244)
263
-
Display of the Life of the Inverter Parts (Pr. 255 to Pr. 259)
264
-
Maintenance Timer Alarm (Pr. 503, Pr. 504)
268
-
Current Average Value Monitor Signal (Pr. 555 to Pr. 557)
269
-
Free Parameter (Pr. 888, Pr. 889)
271
-
Setting from the Parameter Unit and Operation Panel
272
-
RUN Key Rotation Direction Selection (Pr. 40)
272
-
PU Display Language Selection(Pr.145)
272
-
Operation Panel Frequency Setting/Key Lock Operation Selection (Pr. 161)
273
-
Magnitude of Frequency Change Setting (Pr. 295)
275
-
Buzzer Control (Pr. 990)
276
-
PU Contrast Adjustment (Pr. 991)
276
-
-
FR-E500 Series Operation Panel (PA02) Setting
277
-
Built-In Potentiometer Switching (Pr. 146)
277
-
Bias and Gain of the Built-In Frequency Setting Potentiometer (C22 (Pr. 922) to C25 (Pr. 923))
278
-
-
Parameter Clear/ All Parameter Clear
284
-
Initial Value Change List
285
-
Check and Clear of the Faults History
286
-
-
-
5 Troubleshooting
289
-
Reset Method of Protective Function
290
-
List of Fault or Alarm Indications
291
-
Causes and Corrective Actions
292
-
Correspondences between Digital and Actual Characters
302
-
Check First When You Have a Trouble
303
-
Motor Does Not Start
303
-
Motor or Machine Is Making Abnormal Acoustic Noise
305
-
Inverter Generates Abnormal Noise
305
-
Motor Generates Heat Abnormally
305
-
Motor Rotates in the Opposite Direction
306
-
Speed Greatly Differs from the Setting
306
-
Acceleration/Deceleration Is Not Smooth
306
-
Speed Varies During Operation
307
-
Operation Mode Is Not Changed Properly
307
-
Operation Panel Display Is Not Operating
308
-
Motor Current Is too Large
308
-
Speed Does Not Accelerate
309
-
Unable to Write Parameter Setting
309
-
-
-
6 Precautions for Maintenance and Inspection
312
-
Inspection Items
312
-
Daily Inspection
312
-
Periodic Inspection
312
-
Daily and Periodic Inspection
313
-
Display of the Life of the Inverter Parts
314
-
Checking the Inverter and Converter Modules
315
-
Cleaning
316
-
Replacement of Parts
316
-
Inverter Replacement
319
-
-
Measurement of Main Circuit Voltages, Currents and Powers
320
-
Measurement of Powers
322
-
Measurement of Voltages and Use of PT
322
-
Measurement of Currents
323
-
Use of CT and Transducer
323
-
Measurement of Inverter Input Power Factor
323
-
Measurement of Converter Output Voltage (Across Terminals P/+ and N/-)
323
-
Measurement of Inverter Output Frequency
323
-
Insulation Resistance Test Using Megger
324
-
Pressure Test
324
-
-
-
7 Specifications
325
-
Rating
326
-
Common Specifications
328
-
Outline Dimension Drawings
329
-
-
Appendix
335
-
Appendix 1 for Customers Who Are Replacing the Conventional Model with this Inverter
336
-
Appendix 1-1 Replacement of the FR-E500 Series
336
-
Appendix 2 Specification Change
338
-
Appendix 2-1 SERIAL Number Check
338
-
Appendix 2-2 Changed Functions
338
-
Appendix3 Index
341
-
Advertisement
Advertisement
Related Products
-
Mitsubishi Electric FR-E740-5.5K
-
Mitsubishi Electric FR-E740-5.5KNF
-
Mitsubishi Electric FR-E740EC
-
Mitsubishi Electric FR-E740-1.5K(SC)
-
Mitsubishi Electric FR-E740-3.7K(SC)
-
Mitsubishi Electric FR-E740-15K-NE
-
Mitsubishi Electric FR-E740-3.7K-NE
-
Mitsubishi Electric FR-E740-230
-
Mitsubishi Electric FR-E740-300SC
-
Mitsubishi Electric FR-E740-0.4KNF
Mitsubishi Electric Categories
Air Conditioner
Controller
Projector
Inverter
Heat Pump
More Mitsubishi Electric Manuals
FR-E700
INSTRUCTION MANUAL (BASIC)
FR-E720-0.1K to 15K
FR-E740-0.4K to 15K
FR-E720S-0.1K to 2.2K
FR-E710W-0.1K to 0.75K
INVERTER
5
6
7
8
9
10
4
3
2
1
CONTENTS
Thank you for choosing this Mitsubishi Inverter.
This Instruction Manual (Basic) provides handling information and precautions for use of the equipment.
Please forward this Instruction Manual (Basic) to the end user.
To obtain the Instruction Manual (Applied)
Contact where you purchased the inverter, your Mitsubishi sales
representative, or the nearest Mitsubishi FA Center for the following
manual:
y Instruction Manual (Applied) [IB(NA)-0600277ENG]
This manual is required if you are going to utilize functions and
performance.
The PDF version of this manual is also available for download at
«MELFANS Web,» the Mitsubishi Electric FA network service on the
world wide web (URL: http://www.MitsubishiElectric.co.jp/melfansweb).