Gasalertmax xt ii руководство

BW Technologies GasAlertMax XT II Technical Reference Manual

  • Contents

  • Table of Contents

  • Troubleshooting

  • Bookmarks

Quick Links

1, 2, 3, and

4-Gas Detector

Technical Reference Guide

loading

Related Manuals for BW Technologies GasAlertMax XT II

  • Security Sensors BW Technologies GasAlertMicroClip XT User Manual

  • Security Sensors BW Technologies GasAlertMax User Manual

  • Security Sensors BW Technologies GasAlertMicro 3 User Manual

  • Security Sensors BW Technologies GasAlert Extreme User Manual

  • Security Sensors BW Technologies GASALERT EXTREME Quick Reference Manual

  • Security Sensors BW Technologies GasAlertClip Extreme 2 Year Instruction Sheet

  • Security Sensors BW Technologies Quattro Technical Reference Manual

  • Security Sensors BW Technologies CONNEX1 Operator's Manual

  • Security Sensors BW Technologies MicroClip XT Operator's Manual

  • Security Sensors BW Technologies Max XT II Operator's Manual

  • Security Sensors BW Technologies NH3 RESPONDER Quick Reference Manual

  • Security Sensors BW Technologies GasAlertClip Extreme O2 Instruction Sheet

  • Security Sensors BW Technologies GasAlertMicro 5 IR Quick Reference Manual

    Security Sensors BW Technologies GasAlertMicro 5 IR Quick Reference Manual

    O2, co, h2s, ph3, so2, cl2, nh3, no2, hcn, clo2, o3, voc, co2 and combustibles 1, 2, 3, 4, and 5 gas detectors (20 pages)

Summary of Contents for BW Technologies GasAlertMax XT II

  • Page 1
    1, 2, 3, and 4-Gas Detector Technical Reference Guide…
  • Page 2: Table Of Contents

    Introduction …………………………….1 Gases Monitored …………………………..2 Safety Information — Read First……………………….2 Getting Started …………………………….6 Parts of the GasAlertMax XT II……………………….7 Display Elements …………………………..8 Activating/Deactivating the Detector ……………………..10 Startup Tests …………………………….10 Battery Test …………………………….. 10 Audible/Visual Test …………………………..

  • Page 3: Title Page

    GasAlertMax XT II Technical Reference Guide Title Page Bump Test…………………………….17 Force Bump Enabled (optional) ……………………….. 18 Startup Test Pass …………………………..18 Startup Test Fail…………………………..19 Installing Fleet Manager II …………………………20 Using Fleet Manager II to Configure the Detector ………………….20 Device Configuration …………………………..

  • Page 4
    GasAlertMax XT II Technical Reference Guide Title Page Calibration Interval …………………………… 28 Bump Interval …………………………… 28 Low Alarm …………………………….28 High Alarm …………………………….28 TWA Alarm…………………………….29 STEL Alarm…………………………….29 STEL Interval …………………………… 30 TWA Period (hours) …………………………. 30 Correction Factor (%)…………………………30 50% LEL = (%CH4)…………………………..
  • Page 5
    GasAlertMax XT II Technical Reference Guide Title Page Calibration …………………………….40 Guidelines …………………………….40 Diagnostics Protection …………………………41 Connecting the Gas Cylinder to the Detector …………………… 41 Calibration Procedure …………………………42 Auto Zero Sensor…………………………43 Auto Span …………………………… 44 Calibration Due Date …………………………45 Verification …………………………..
  • Page 6
    GasAlertMax XT II Technical Reference Guide Title Page General Datalogger Specifications ……………………..67…
  • Page 7
    List of Figures Figure Title Page Parts of the GasAlertMax XT II……………………..7 Display Elements…………………………8 Connecting the IR Link ……………………….20 Device Configuration Section ……………………..21 Sensor Configuration Tab (H S) ……………………26 Connecting the Gas Cylinder to the Detector ………………… 42 Calibrate Device Dialog Box……………………..
  • Page 8
    List of Tables Table Title Page Gases Monitored …………………………2 International Symbols ……………………….5 Parts of the GasAlertMax XT II……………………..7 Display Elements…………………………8 Pushbutton …………………………..9 Connecting the IR Link ……………………….20 Alarms …………………………..32 Computed Gas Exposures ……………………..35 Gas Alarm Setpoints ……………………….
  • Page 9: Contacting Bw Technologies By Honeywell

    To ensure personal safety, read Safety Information — Read First and aCautions before using the detector. The GasAlertMax XT II gas detector (“the detector”) warns of hazardous gas at levels above user-defined alarm setpoints. The detector is a personal safety device. It is your respons bility…

  • Page 10: Gases Monitored

    GasAlertMax XT II Technical Reference Guide Safety Information — Read First Gases Monitored Use the detector only as specified in this technical reference guide, The following table lists the gases that are monitored by the detector. otherwise the protection provided by the detector may be impaired.

  • Page 11
    • Do not use the detector if it is damaged. Inspect the detector before using. Look for cracks and/or missing parts. • Use only sensor(s) that are specifically designed for the GasAlertMax XT II model. Refer to Replacement Parts and Accessories •…
  • Page 12
    212°F (100°C), or incinerate. • Do not use any other lithium batteries with the GasAlertMax XT II detector. Use of any other cell can cause fire and/or explosion. To order and replace the MX-BAT01 battery, refer to…
  • Page 13
    GasAlertMax XT II Safety Information — Read First aCautions • Warning: Lithium polymer cells exposed to heat at 266°F (130°C) for 10 minutes can cause fire and/or explosion. • Dispose of used lithium cells immediately. Do not disassemble and do not dispose of in fire. Do not mix with the solid waste stream.
  • Page 14: Getting Started

    GasAlertMax XT II Technical Reference Guide Getting Started The detector is shipped with the sensors, pump, and rechargeable battery installed. To replace sensors, the pump, or the battery, refer to The list below provides the standard items included with the detector.

  • Page 15: Parts Of The Gasalertmax Xt Ii

    GasAlertMax XT II Parts of the GasAlertMax XT II Parts of the GasAlertMax XT II Table 3. Parts of the GasAlertMax XT II Item Description Visual alarm indicators (LEDs) Pump quick connector Pump filter and moisture filter Pushbutton Alligator clip…

  • Page 16: Display Elements

    GasAlertMax XT II Technical Reference Guide Display Elements Table 4. Display Elements Item Description Alarm condition Automatically zero sensor indicator Numeric values Battery life indicator Pump indicator Heartbeat indicator Gas type identifiers Gas cylinder indicator Automatically span sensor indicator Figure 2. Display Elements…

  • Page 17
    GasAlertMax XT II Display Elements Table 5. Pushbutton Pushbutton Description • To activate the detector press C. • To deactivate the detector, press and hold C until the OFF countdown is complete and the LCD deactivates. • To view the date/time, TWA, STEL, and maximum (MAX) readings, press C twice rapidly. To clear the TWA, STEL, and MAX readings, press C when the LCD displays CLEAR ALL.
  • Page 18: Activating/Deactivating The Detector

    GasAlertMax XT II Technical Reference Guide Activating/Deactivating the Detector Battery Test Note The detector performs a battery test during startup. If the battery has insufficient power to operate, the following screens displays before Ensure the diffusion cover is attached prior to activating the deactivating.

  • Page 19: Firmware Version

    GasAlertMax XT II Startup Tests Firmware Version Location Logging 2. The current firmware version installed on the detector 4. If the Location Logging option is enabled, the detector displays on the LCD. prompts for a number (1-999) to be entered that identifies the location (wells, plants, or other areas) where the detector is being used.

  • Page 20: Pump Test On Startup

    GasAlertMax XT II Technical Reference Guide Pump Test on Startup Using your finger, block the end of the hose. The follow- ing screen displays. Note The diffusion cover must be attached to the detector to activate the pump and initiate the pump test.

  • Page 21: Alarm Setpoints

    GasAlertMax XT II Startup Tests Unsuccessful Block Pump Test: If the pump is not When the diffusion cover is replaced, the detector operating correctly, the following screens display before activates the pump alarm. the detector deactivates. HIGH displays, and L and J flashes. Press C to Activate the detector again.

  • Page 22: Self-Test

    GasAlertMax XT II Technical Reference Guide Next, the LOW and HIGH alarm setpoints display for all Unsuccessful Self-Test of the enabled sensors. Lockout on Self-Test Error Option Enabled: If this option is enabled and a sensor fails, the following screens display before the detector deactivates.

  • Page 23: Automatic Zero For H S, Co, O , And Lel

    Only activate the detector in a safe area that is free of hazardous gas to ensure an accurate auto zero. 8. To initiate auto zero during startup, the Auto Zero on Startup option must be enabled (sensors are enabled Note individually). BW Technologies by Honeywell recommends the sensor(s) be calibrated immediately.

  • Page 24: Calibration Due Date (Optional)

    GasAlertMax XT II Technical Reference Guide Calibration Due Date (optional) Force Calibration Enabled (optional) 9. The LCD displays the number of days remaining until the 10. If the Force Calibration option is enabled in Fleet next calibration is due. Manager II and a sensor is past due, the sensor(s) must be calibrated to continue and enter normal operation.

  • Page 25: Cal Ir Lock Enabled (Optional)

    Options. Bump Test Note BW Technologies by Honeywell recommends to bump test the sensors before each day’s use to confirm their ability to respond to gas by exposing the detector to a gas concentration that exceeds the alarm setpoints.

  • Page 26: Force Bump Enabled (Optional)

    GasAlertMax XT II Technical Reference Guide 12. The LCD next displays the number of days remaining If Force Bump is disabled, press C to acknowledge the until the next bump test is due. warning and continue with the startup tests.

  • Page 27: Startup Test Fail

    GasAlertMax XT II Startup Tests Startup Test Fail After the detector enters normal operation, ERR displays if a sensor has failed the self-test. To determine the cause and solutions for a failed sensor, refer to Troubleshooting.

  • Page 28: Installing Fleet Manager Ii

    GasAlertMax XT II Technical Reference Guide Installing Fleet Manager II Fleet Manager II is required to configure the detector. To install Fleet Manager II, refer to the Fleet Manager II CD-ROM that includes the • installation wizard, and • Fleet Manager II Operator’s Manual.

  • Page 29: Device Configuration

    GasAlertMax XT II Device Configuration Device Configuration 8. From the Devices too bar, click Configure Device via IR Link to access the GasAlertMax XT Configuration The Device Configuration section displays data about the detector, window. allows for a startup message to be entered, and is used to enable/dis- 9.

  • Page 30: Serial Number Field

    GasAlertMax XT II Technical Reference Guide Startup Message Bottom Line Refer to the following options for descriptions and functionality. Enter a line of text that will display on the detector LCD during startup Note (maximum 25 characters, spaces included). Enter any type of informa- The Serial Number, Firmware Version, and Hardware tion such as employee name, plant, area, emergency number(s), etc.

  • Page 31: Safe Mode

    GasAlertMax XT II Device Configuration Safe Mode display the high peak concentration until the alarm condition no longer exists. If enabled, SAFE displays continuously on the LCD unless an alarm The detector is shipped with the Latching Alarms option disabled.

  • Page 32: Force Bump

    GasAlertMax XT II Technical Reference Guide Force Bump Cal IR Lock A bump test must be performed regularly to ensure the sensor(s) are If enabled, the sensor(s) can only be calibrated using the IR Link with responding correctly to test gas. If enabled and the sensor(s) is past due, Fleet Manager II or the MicroDock II station.

  • Page 33: Location Logging

    GasAlertMax XT II Device Configuration Location Logging Force Block Test The Location Logging logs where the detector is being used such as a The force block test verifies the pump is operating correctly by compar- gas plant, well site, vehicle, etc.

  • Page 34: Confidence Interval

    GasAlertMax XT II Technical Reference Guide Sensor Configuration Confidence Interval The Sensor Configuration tab adjusts settings for each individual The Confidence Interval (seconds) field defines how often the sensor. A separate sensor tab is provided for each sensor. Figure 5.

  • Page 35: Sensor Disabled

    GasAlertMax XT II Sensor Configuration Sensor Disabled 5. The LCD automatically updates. In the following exam- ple, the CO gas type and sensor readings no longer a Warning displays. Use extreme caution when disabling a sensor. The disabled sensor cannot detect and alarm against the applicable gas.

  • Page 36: Calibration Interval

    GasAlertMax XT II Technical Reference Guide Calibration Interval setpoints. Verify that the audible and visual alarms activate. Calibrate if the readings are not within the specified limits. Define how often a sensor must be calibrated in the Calibration Interval (days) field. A different cal bration interval can be set for each sensor.

  • Page 37: Twa Alarm

    GasAlertMax XT II Sensor Configuration TWA Alarm STEL Alarm The time-weighted average (TWA) is a safety measure used to The short term exposure limit (STEL) is the maximum permissible gas determine accumulated averages of gases. An average is determined concentration a worker can be safely exposed to for short periods of time using the Occupational Safety and Health Administration (OSHA) (5-15 minutes maximum).

  • Page 38: Stel Interval

    GasAlertMax XT II Technical Reference Guide STEL Interval Note Regulations vary depending upon region. Adhere to the regula- The STEL Interval option provides protection for workers from over tions defined for your area. exposure to high concentrations of gas, and is based on user-defined 5-15 minute intervals.

  • Page 39: 50% Lel = (%Ch4)

    GasAlertMax XT II Sensor Configuration 50% LEL = (%CH4) 10% (of reading) Over-span If the LEL By Volume CH4 option is enabled, a percentage value can be When enabled, the detector automatically over-spans the LEL sensor by entered in the 50% LEL = (%CH4) field to display the LEL reading in 10% of the span concentration to ensure the span meets CSA stan- %vol.

  • Page 40: Alarms

    GasAlertMax XT II Technical Reference Guide Alarms Table 7 describes the detector alarms and corresponding screens. During an alarm condition, the detector activates the backlight, audible/visual/ vibrator alarms, and displays the current ambient gas reading. If more than one type or level of alarm exists simultaneously, a multi-gas alarm results.

  • Page 41
    GasAlertMax XT II Alarms Table 7. Alarms Alarm Screen Alarm Screen Multi-Gas Alarm Sensor Alarm • Alternating low and high alarm siren and flash • ERR displays • L and target gas bar flash • Vibrator alarm activates Over Limit (OL) Alarm Low Battery Alarm •…
  • Page 42
    GasAlertMax XT II Technical Reference Guide Table 7. Alarms Alarm Screen Alarm Screen Automatic Deactivation Alarm Confidence Beep • Sequence of 10 rapid sirens and alternating • One beep every 1-120 seconds (user-defined) flashes with 1 second of silence in between…
  • Page 43: Computed Gas Exposures

    GasAlertMax XT II Computed Gas Exposures Computed Gas Exposures Viewing and Clearing Gas Exposures a Warning To view the TWA, STEL, and maximum (MAX) readings, press C twice rapidly. The LCD first displays the current time and date. To prevent possible personal injury, do not deactivate the detector during a work shift.

  • Page 44: Gas Alarm Setpoints

    GasAlertMax XT II Technical Reference Guide Gas Alarm Setpoints Next, the MAX readings display. The alarm setpoints trigger the gas alarms and are described Table 9. Table 9. Gas Alarm Setpoints Alarm Condition Toxics and combustibles: Ambient Last, the CLEAR ALL readings screen displays.

  • Page 45: Resetting Gas Alarm Setpoints

    GasAlertMax XT II Computed Gas Exposures Resetting Gas Alarm Setpoints Stopping a Gas Alarm Table 10. lists alarm setpoints as defined by Occupational Safety and The low and high alarms stop when the ambient gas concentrations Health Association (OSHA). returns to a concentration below the low alarm setpoint.

  • Page 46: Pump Alarm

    GasAlertMax XT II Technical Reference Guide Pump Alarm Low Battery Alarm The pump draws air over the sensors continually. If the pump stops The detector tests the battery on activation and continuously thereafter. operating or becomes blocked, the detector activates the pump alarm.

  • Page 47: Bump Test

    GasAlertMax XT II Bump Test Bump Test 4. The detector should enter alarm. Verify the audible and visual alarms activate, and that the LCD readings match A bump test is the process of applying a small amount of test gas to the span gas concentrations of the gas cylinder being force the detector into alarm.

  • Page 48: Calibration

    GasAlertMax XT II Technical Reference Guide Calibration • If a certified calibration is required, contact BW Technologies by Honeywell. Guidelines • Cal bration can be performed using either a 0.5 l/min regulator or a demand flow regulator. Recommended gas mixture: •…

  • Page 49: Diagnostics Protection

    GasAlertMax XT II Calibration Diagnostics Protection Connecting the Gas Cylinder to the Detector The detector tests the ambient air (auto-zero) and the test gas that is Refer to the following procedures and Figure 6. to connect the gas applied (auto span) to ensure it meets expected values. Auto-zero sets cylinder to the detector for calibration.

  • Page 50: Calibration Procedure

    GasAlertMax XT II Technical Reference Guide Calibration Procedure 5. When calibration is complete, disconnect the hose from the detector and the regulator. a Caution 6. Ensure the gas cylinder is stored according to the Calibrate only in a safe area that is free of hazardous manufacturer’s specifications.

  • Page 51: Auto Zero Sensor

    GasAlertMax XT II Calibration 4. Press and hold C while the detector performs the OFF flashes while the detector automatically zeroes countdown. Continue to hold C as the detector briefly the combustible and toxic sensors, and calibrates the deactivates. oxygen sensor.

  • Page 52: Auto Span

    GasAlertMax XT II Technical Reference Guide Auto Span Unsuccessful Span If the sensor(s) fails the span, the following screen displays. When auto zero is complete, APPLY GAS and display, and flashes. Refer to the following for possible causes and solutions.

  • Page 53: Calibration Due Date

    GasAlertMax XT II Calibration Calibration Due Date If a sensor(s) fails any step of the cal bration, the following screen displays. If a sensor(s) does not successfully span, the calibration due date for that sensor(s) will not reset. Note If calibration is unsuccessful for a sensor(s), the calibration due…

  • Page 54: Verification

    GasAlertMax XT II Technical Reference Guide After the span is complete, the following calibration due date screens If a sensor fails to span successfully and it is past the calibration due display before returning to normal operation. date, the following screens display.

  • Page 55: Calibrating Using The Ir Link

    GasAlertMax XT II Calibration 3. To ensure the readings are accurate, apply the verifica- To calibrate using the IR Link, complete the following: tion gas for the same amount of time as was applied to 1. From the PC, open Fleet Manager II.

  • Page 56
    GasAlertMax XT II Technical Reference Guide 7. Enter the span gas concentration values. The values entered in the Calibrate Device popup must match the span concentration values on the gas cylinder. 8. Click inside the checkbox for each sensor that will be calibrated, and then click Calibrate.
  • Page 57: Event Logs

    GasAlertMax XT II Event Logs Event Logs The following information is recorded in a datalog: • Serial number of the detector The detector records the thirty most recent gas alarm events. Information that is recorded from an event is as follows: •…

  • Page 58: Bump And Calibration Results

    GasAlertMax XT II Technical Reference Guide Bump and Calibration Results • Audible and visual indicator status • Sensor type and sensor status The detector records the bump test and calibration results. The results can then be imported into Fleet Manager II to create detailed reports.

  • Page 59: Maintenance

    Refer to Charging the Battery. • Charge the battery using the GasAlertMax XT II or the GasAlertMicroClip charger adapter only. Do not use any other charger adapters. Failure to adhere to this precaution can lead to fire and/or explosion.

  • Page 60: Charging The Battery

    GasAlertMax XT II Technical Reference Guide Charging the Battery Table 11. Connecting the Charger Adapter Item Description IR and charger interface GasAlertMax XT II Charger adapter Charger cable a Warning The detector must be charged in a safe area that is free of hazardous gas in temperatures of 32°F to 113°F…

  • Page 61: Optimum Battery Operation

    GasAlertMax XT II Maintenance Replacing the Battery 4. Allow the battery to charge for 6 hours. The charging indicator flashes (low, mid, and full charge repeatedly) on To replace the lithium battery, refer to Replacement Parts and Accesso- the LCD while the battery is charging.

  • Page 62
    GasAlertMax XT II Technical Reference Guide Table 12. Replacing a Sensor or Sensor Filter Item Description Front shell LEL sensor PCB screws (2) Pump Rear shell Machine screws (6) Pump inlet Pump filter (particulate) Moisture filter CO sensor S sensor…
  • Page 63
    GasAlertMax XT II Maintenance Figure 9. Replacing a Sensor or Sensor Filter…
  • Page 64
    GasAlertMax XT II Technical Reference Guide 1. Deactivate the detector. 5. Remove the two PCB screws. 2. Remove the pump inlet screw and the pump inlet. Refer 6. Lift the PCB upward and tilt to the left. Lay the PCB Figure 13.
  • Page 65: Replacing The Pump Filters

    GasAlertMax XT II Maintenance Replacing the Pump Filters Note When inserting a new sensor filter, ensure the white side is Filters are inserted into the pump inlet to prevent dust particulates and facing the sensors and the black side is facing the front shell.

  • Page 66
    GasAlertMax XT II Technical Reference Guide 1. Remove the one machine screw from the pump inlet and gently lift the bottom of the inlet outward at a 45° angle. Figure 13. Removing the Pump Filters 2. Gently lift the pump inlet upwards to remove. Ensure the Figure 12.
  • Page 67: Replacing The Pump

    GasAlertMax XT II Maintenance 3. Depending upon the circumstance, replace either just the particulate filter or both. Refer to Particulate Filters Moisture Filters. 4. Reattach the pump inlet and replace the screw. Tighten the screw using 3-4 in-lbs. torque. Do not overtighten.

  • Page 68: Troubleshooting

    GasAlertMax XT II Technical Reference Guide Troubleshooting If a problem occurs, refer to the solutions provided in Table 15. If the problem persists, contact BW Technologies by Honeywell. Figure 14. Troubleshooting Problem Possible Cause Solution The detector does not activate.

  • Page 69
    GasAlertMax XT II Troubleshooting Table 7. Troubleshooting Problem Possible Cause Solution Detector does not display normal Sensors not stabilized Used sensor: Wait 60 seconds ambient gas reading after startup tests. New sensor: Wait 5 minutes Sensor(s) requires calibration Calibrate the sensor(s). Refer to Calibration.
  • Page 70
    GasAlertMax XT II Technical Reference Guide Table 7. Troubleshooting Problem Possible Cause Solution Detector intermittently enters alarm Ambient gas levels are near alarm Detector is operating normally. Use caution in without reason. setpoint or the sensor is exposed to a suspect areas.
  • Page 71: Replacement Parts And Accessories

    Quad calibration kit with regulator, quad gas Model No. Description CK-Q58-4 cylinder (CG-Q58-4), hose, and carrying case SR-W- Combustible (LEL) sensor XT-SS-1 Sensor filter for GasAlertMax XT II, Kit of 2 MC75C GA-PFMAX Particulate filters (kit of 5) Oxygen (O ) sensor SR-X10-C1 GA-PFMAX-…

  • Page 72
    GasAlertMax XT II Technical Reference Guide Model No. Description XT-SCREW- Replacement screw kit (40 screws and screw- driver) XT-BAT-K1 Battery replacement kit XT-RPUMP- Pump replacement kit GA-HXT GasAlertMax XT carrying holster GA-BXT GasAlertMax XT rubber boot XT-AG-1 Alligator clip (stainless steel) *Add suffix (-UK) for United Kingdom mains plug, (-EU) for European mains plug, (-AU) for Australian mains plug.
  • Page 73: Specifications

    GasAlertMax XT II Specifications Specifications Visual alarm: Red light-emitting diodes (LEDs) Display: Alphanumeric liquid crystal display (LCD) Instrument dimensions: 13.1 x 7.0 x 5.2 cm (5.1 x 2.8 x 2.0 in.) Backlight: Activates upon startup and when the pushbutton is pressed;…

  • Page 74
    GasAlertMax XT II Technical Reference Guide Approved battery for GasAlertMax XT II product: This equipment has been tested and found to comply with the limits Lithium-ion polymer (MA-BAT01) as per standards EN50020, UL913, for a Class B digital device, pursuant to Part 15 of the FCC Rules and CSA C22.2 No.
  • Page 75
    GasAlertMax XT II Specifications General Datalogger Specifications Storage: 375 hours at 15-second intervals (75% redundancy) Memory type: Wraparound memory ensures most recent data is always saved Sample rate: One reading every 1-120 seconds Data recorded: All sensor readings, all alarm conditions, cal brations,…

User Manual for BW models including: GasAlertMax XT II, 1 2 3 and 4 Gas Detector

GasAlertMaxXT II User Manual 129541 B EN.book

H212562

GasAlertMaxXT II User Manual 129541 B EN — Honeywell

Limited Warranty and Limitation Liability BW Technologies LP (BW) warrants the product to be free from defects in material and workmanship under normal use and service for a period of two years, beginning on the date of

  • PDF Viewer
  • Universal Document Viewer
  • Google Docs View
  • Google Drive View
  • Download Document [pdf]
  • Download Document [Optimized]
  • Document:
    • Text
    • References

Not Your Device? Search For Manuals / Datasheets:

File Info : application/pdf, 81 Pages, 1.79MB

Documentgasalertmaxxt ii user manual 129541 en b

1, 2, 3, 4 Gas Detector
User Manual

Limited Warranty and Limitation Liability
BW Technologies LP (BW) warrants the product to be free from defects in material and workmanship under normal use and service for a period of two years, beginning on the date of shipment to the buyer. This warranty extends only to the sale of new and unused products to the original buyer. BW's warranty obligation is limited, at BW's option, to refund of the purchase price, repair or replacement of a defective product that is returned to a BW authorized service center within the warranty period. In no event shall BW's liability hereunder exceed the purchase price actually paid by the buyer for the Product. This warranty does not include:
a) fuses, disposable batteries or the routine replacement of parts due to the normal wear and tear of the product arising from use; b) any product which in BW's opinion, has been misused, altered, neglected or damaged, by accident or abnormal conditions of operation, handling or use; c) any damage or defects attributable to repair of the product by any person other than an authorized dealer, or the installation of unapproved parts on the product; or The obligations set forth in this warranty are conditional on: a) proper storage, installation, calibration, use, maintenance and compliance with the product manual instructions and any other applicable recommendations of BW; b) the buyer promptly notifying BW of any defect and, if required, promptly making the product available for correction. No goods shall be returned to BW until receipt by the buyer of
shipping instructions from BW; and c) the right of BW to require that the buyer provide proof of purchase such as the original invoice, bill of sale or packing slip to establish that the product is within the warranty period. THE BUYER AGREES THAT THIS WARRANTY IS THE BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. BW SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR BASED ON CONTRACT, TORT OR RELIANCE OR ANY OTHER THEORY. Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this warranty is held invalid or unenforceable by a court of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision.

BW Technologies by Honeywell Corporate Headquarters 2840 - 2nd Ave. SE Calgary, AB Canada T2A 7X9

BW Technologies by Honeywell America 3279 West Pioneer Parkway Arlington, TX USA 76013

BW Technologies by Honeywell Europe 5 Canada Close Banbury, Oxfordshire United Kingdom OX16 2RT

Table of Contents

Title

Page

Contacting BW Technologies by Honeywell .................................................................................................................... 1 Introduction ......................................................................................................................................................................... 1
Gases Monitored ............................................................................................................................................................. 2 Safety Information - Read First.......................................................................................................................................... 2 Getting Started .................................................................................................................................................................... 7 Parts of the GasAlertMaxXT II............................................................................................................................................ 8 Display Elements ................................................................................................................................................................ 9 Activating/Deactivating the Detector .............................................................................................................................. 11 Startup Tests ..................................................................................................................................................................... 11
Battery Test ................................................................................................................................................................... 11 Audible/Visual Test ........................................................................................................................................................ 11
Firmware Version ..................................................................................................................................................... 12 Startup Message ...................................................................................................................................................... 12 Location Logging ...................................................................................................................................................... 12 Pump Test on Startup .................................................................................................................................................... 13 Alarm Setpoints ............................................................................................................................................................. 14 Self-Test ........................................................................................................................................................................ 15 Automatic Zero for H2S, CO, O2, and LEL .................................................................................................................... 16 If Previous Calibration Failed ......................................................................................................................................... 16 Calibration Due Date (optional) ..................................................................................................................................... 17 Force Calibration Enabled (optional) ............................................................................................................................. 17 Cal IR Lock Enabled (optional) ...................................................................................................................................... 18 If Previous Bump Failed................................................................................................................................................. 18
i

GasAlertMaxXT II User Manual

Title

Page

Bump Test...................................................................................................................................................................... 18 Force Bump Enabled (optional) ..................................................................................................................................... 19 Startup Test Pass .......................................................................................................................................................... 19 Startup Test Fail............................................................................................................................................................. 20 Installing Fleet Manager II ................................................................................................................................................ 21 Using Fleet Manager II to Configure the Detector ......................................................................................................... 21 Device Configuration ........................................................................................................................................................ 22 Serial Number Field ....................................................................................................................................................... 23 Firmware Version ........................................................................................................................................................... 23 Hardware Version .......................................................................................................................................................... 23 Startup Message Top Line ............................................................................................................................................. 23 Startup Message Bottom Line........................................................................................................................................ 23 Lockout on Self-Test Error (failed sensor lock) .............................................................................................................. 23 Safe Mode...................................................................................................................................................................... 24 Confidence Beep ........................................................................................................................................................... 24 Latching Alarms ............................................................................................................................................................. 24 Force Calibration............................................................................................................................................................ 24 Force Bump ................................................................................................................................................................... 25 Cal IR Lock .................................................................................................................................................................... 25 Location Logging............................................................................................................................................................ 26 Force Block Test ............................................................................................................................................................ 26 Datalog Interval .............................................................................................................................................................. 26 Confidence Interval ........................................................................................................................................................ 27 Language ....................................................................................................................................................................... 27 Sensor Configuration ....................................................................................................................................................... 27 Sensor Disabled............................................................................................................................................................. 28 Calibration Gas (ppm) .................................................................................................................................................... 28

ii

GasAlertMaxXT II User Manual

Title

Page

Calibration Interval ......................................................................................................................................................... 29 Bump Interval ................................................................................................................................................................. 29 Low Alarm ...................................................................................................................................................................... 29 High Alarm ..................................................................................................................................................................... 29 TWA Alarm..................................................................................................................................................................... 30 STEL Alarm.................................................................................................................................................................... 30 STEL Interval ................................................................................................................................................................. 31 TWA Period (hours) ....................................................................................................................................................... 31 Correction Factor (%)..................................................................................................................................................... 31 50% LEL = (%CH4)........................................................................................................................................................ 32 Auto Zero on Startup...................................................................................................................................................... 32 LEL by Volume CH4 ...................................................................................................................................................... 32 10% (of reading) Over-span........................................................................................................................................... 32 20.8 Base Reading ........................................................................................................................................................ 32 Low Alarm Acknowledge................................................................................................................................................ 32 Alarms ................................................................................................................................................................................ 33 Computed Gas Exposures ............................................................................................................................................... 36 Viewing and Clearing Gas Exposures ........................................................................................................................... 36 Gas Alarm Setpoints ...................................................................................................................................................... 37 Resetting Gas Alarm Setpoints ...................................................................................................................................... 38 Stopping a Gas Alarm .................................................................................................................................................... 38 Sensor Alarm ................................................................................................................................................................. 38 Pump Alarm ................................................................................................................................................................... 39 Low Battery Alarm.......................................................................................................................................................... 39 Automatic Deactivation Alarm ........................................................................................................................................ 39 Bump Test.......................................................................................................................................................................... 40 Bump Test Using the MicroDock II Station .................................................................................................................... 40

iii

GasAlertMaxXT II User Manual

Title

Page

Calibration ......................................................................................................................................................................... 41 Guidelines ...................................................................................................................................................................... 41 Diagnostics Protection ................................................................................................................................................... 42 Connecting the Gas Cylinder to the Detector ................................................................................................................ 42 Calibration Procedure .................................................................................................................................................... 43 Auto Zero Sensor...................................................................................................................................................... 44 Auto Span ................................................................................................................................................................. 45 Calibration Due Date ................................................................................................................................................ 46 Verification ................................................................................................................................................................ 47 Calibrating Using the IR Link ......................................................................................................................................... 48
Event Logs ......................................................................................................................................................................... 50 Datalogs ............................................................................................................................................................................. 50 Bump and Calibration Results ......................................................................................................................................... 51
Downloading Datalogs and Event Logs ......................................................................................................................... 51 Software Requirements ................................................................................................................................................. 51 Maintenance ...................................................................................................................................................................... 52 Maximum Hose Length for Sampling ............................................................................................................................. 52 Battery Maintenance and Cautions ................................................................................................................................ 52 Charging the Battery ...................................................................................................................................................... 53
Optimum Battery Operation ...................................................................................................................................... 54 Replacing the Battery..................................................................................................................................................... 54 Replacing a Sensor or Sensor Filter .............................................................................................................................. 54 Replacing the Pump Filters ............................................................................................................................................ 58 Replacing the Pump....................................................................................................................................................... 60 Troubleshooting ................................................................................................................................................................ 61 Replacement Parts and Accessories .............................................................................................................................. 64 Specifications .................................................................................................................................................................... 66

iv

GasAlertMaxXT II User Manual

Title

Page

General Datalogger Specifications ................................................................................................................................ 68

v

GasAlertMaxXT II User Manual
Title

Page

vi

List of Figures

Figure Title

Page

1.

Parts of the GasAlertMaxXT II.............................................................................................................................. 8

2.

Display Elements.................................................................................................................................................. 9

3.

Connecting the IR Link ....................................................................................................................................... 21

4.

Device Configuration Section ............................................................................................................................. 22

5.

Sensor Configuration Tab (H2S) ........................................................................................................................ 27

6.

Connecting the Gas Cylinder to the Detector ..................................................................................................... 43

7.

Calibrate Device Dialog Box............................................................................................................................... 48

8.

Connecting the Charger Adapter........................................................................................................................ 53

9.

Replacing a Sensor or Sensor Filter .................................................................................................................. 56

10.

Front and Rear Shells Side by Side ................................................................................................................... 57

11.

Remove the O2 Sensor With a Scredriver.......................................................................................................... 57

12.

Replacing the Pump Filters ................................................................................................................................ 59

13.

Removing the Pump Filters ................................................................................................................................ 59

14.

Troubleshooting.................................................................................................................................................. 61

vii

GasAlertMaxXT II User Manual
viii

Table
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14.

List of Tables

Title

Page

Gases Monitored .................................................................................................................................................. 2 International Symbols ........................................................................................................................................... 6 Parts of the GasAlertMaxXT II.............................................................................................................................. 8 Display Elements.................................................................................................................................................. 9 Pushbutton ......................................................................................................................................................... 10 Connecting the IR Link ....................................................................................................................................... 21 Alarms ................................................................................................................................................................ 33 Computed Gas Exposures ................................................................................................................................. 36 Gas Alarm Setpoints .......................................................................................................................................... 37 Sample Factory Alarm Setpoints ........................................................................................................................ 38 Connecting the Charger Adapter........................................................................................................................ 53 Replacing a Sensor or Sensor Filter .................................................................................................................. 55 Replacing the Pump Filters ................................................................................................................................ 58 Replacement Parts and Accessories ................................................................................................................. 64

ix

GasAlertMaxXT II User Manual
x

Contacting BW Technologies by Honeywell
To contact BW Technologies by Honeywell, call USA: 1-888-749-8878 Canada: 1-800-663-4164 Europe: +44 (0) 1295 700300 Other countries: +1-403-248-9226 Address correspondence to BW Technologies by Honeywell 2840 ­ 2 Avenue S.E. Calgary, AB T2A 7X9 CANADA Email us at: info@gasmonitors.com Visit BW Technologies by Honeywell's website at: www.gasmonitors.com
ISO 9001

GasAlertMaxXT II
Introduction
a Warning
To ensure personal safety, read Safety Information Read First and aCautions before using the detector. The GasAlertMaxXT II gas detector ("the detector") warns of hazardous gas at levels above user-defined alarm setpoints. The detector is a personal safety device. It is your responsibility to respond properly to the alarm.

1

GasAlertMaxXT II User Manual

Gases Monitored
The following table lists the gases that are monitored by the detector. Table 1. Gases Monitored

Gas Detected

Unit of Measure

Hydrogen sulfide (H2S) Carbon monoxide
Combustible gases (LEL)
Oxygen (O2)

parts per million (ppm)
parts per million (ppm)
a) percent of lower explosive limit (%LEL)
b) percent by volume methane 0-5.0% v/v
% volume

CAUTION: FOR SAFETY REASONS, THIS EQUIPMENT MUST BE OPERATED AND SERVICED BY QUALIFIED PERSONNEL ONLY. READ AND UNDERSTAND THIS TECHNICAL REFERENCE GUIDE COMPLETELY BEFORE OPERATING AND SERVICING.

Safety Information - Read First
Use the detector only as specified in this technical reference guide, otherwise the protection provided by the detector may be impaired.
International symbols used on the detector and in this technical reference guide are defined in
Read the aCautions on the following pages before using the detector.
ec Warning
This instrument contains a lithium polymer battery. Dispose of lithium cells immediately. Do not disassemble and do not dispose of in fire. Do not mix with the solid waste stream. Spent batteries must be disposed of by a qualified recycler or hazardous materials handler.

2

GasAlertMaxXT II Safety Information - Read First
aCautions
· Warning: Substitution of components may impair Intrinsic Safety. · uCnaduetirosnta: nFdorthseafteetcyhrneiacsaol nresf,etrheinsceeqguuipidmeecnotmmpulsettebley obpefeorraeteodpaenradtisnegrvoircesderbvyicqinuga.lified personnel only. Read and · Do not use the detector if it is damaged. Inspect the detector before using. Look for cracks and/or missing parts. · If the detector is damaged or parts are missing, contact BW Technologies by Honeywell immediately. · AUcsceeosnsloyrsieesn.sor(s) that are specifically designed for the GasAlertMaxXT II model. Refer to Replacement Parts and · Cpoailsibornasteatnhde cdoentetacmtoirnbaenftosr.eSfeirnssto-trismme uusset baendcathlibenraotendareregguulalarlrysacnhdedaut llee,adsetpoenncdeinegveorny u1s8e0 adnadysse(6nmsoornetxhpso).sure to · veBixWspuoraselicanolgamrtmmhesendaderetseatcoctotbirvuatmotepadtg.eCassatlctihboernacsteeenniftsrtoahrtesio,rnebaethdfoainrtegesexacacerehedndsoattyh'wseituahslaienr,mtthosecesotppneofciirnimftiset.dhMeliaimrnaiutbsai.llliytyvteorirfeystphoant dthteoaguadsibblye and · sAPerltonhtsoeoucrtgpthhecerfeocrrotmaminabnuocsregt,iabinnleicmsvoeansptsoocrarssfr(eossum, cthheexapssoelsneusardoeretdwogillelaarsedoclcoinovemerapnaodfutehnradclsoa,glsiebilnriacatotieondnes.h,yadnrodccahrlboorninsa)tmedayhytedmropcoarrabroilnysi.nhibit · eBxWporseucoremtmo ecnadtaslytshteccoonmtabmuisntaibnltess/peonissoornbse(scuhlefucrkceodmwpitohuandksn,oswilniccoonnvcaepnotrrast,iohnaloofgceanlaibterdatcioonmgpaosuanfdtesr, eatncy).known · %ThLeEcLomrabnugset,ibclaelisberantseotrhies sfaecntsoorryucsailnibgrathteedatpop5ro0p%riLaEteLgmase.thane. If monitoring a different combustible gas in the · Warning: High off-scale LEL readings may indicate an explosive concentration. · IOnntelyrntahteiocnoaml.bustible gas detection portion of this instrument has been assessed for performance by CSA · For use only in potentially explosive atmospheres where oxygen concentrations do not exceed 20.9% (v/v). · Any rapid up-scaling reading followed by a declining or erratic reading may indicate a gas concentration beyond
upper scale limit, which may be hazardous. · Calibrate only in a safe area that is free of hazardous gas.
3

GasAlertMaxXT II User Manual
aCautions
· Use only BW approved batteries for the GasAlertMaxXT II detector. Refer to Replacement Parts and Accessories. · Charge the detector before first-time use. BW recommends the detector be charged after every workday. · Charge the GasAlertMaxXT II using the recommended charging adapter only. Do not use any other charging adapter.
Failure to adhere to this precaution can lead to fire and/or explosion. Read and adhere to all instructions in the charger operator's manual. Failure to do so can result in fire, electrical shock, personal injury, and/or property damage. · Extended exposure of the GasAlertMaxXT II to certain concentrations of combustible gases and air may stress a detector element, which can seriously affect its performance. If an alarm occurs due to high concentration of combustible gases, recalibration should be performed, or if needed, the sensor replaced. · Do not test the combustible sensor's response with a butane cigarette lighter; doing so will damage the sensor. · Do not expose the detector to electrical shock or severe continuous mechanical shock. · Do not immerse the detector in liquids. · The pump (XT-RPUMP-K1) is certified for use with the GasAlertMaxXT II detector only. · Do not attempt to disassemble, adjust, or service the detector unless instructions for that procedure are provided in the technical reference guide and/or that part is listed as a replacement part. Use only BW Technologies by Honeywell Replacement Parts and Accessories. · The detector warranty will be voided if customer, personnel, or third parties damage the detector during repair attempts. Non-BW Technologies by Honeywell repair/service attempts void this warranty. · Warning: The lithium battery (MX-BAT01) may present a risk of fire or chemical burn hazard if misused. Do not disassemble, heat above 212°F (100°C), or incinerate. · Do not use any other lithium batteries with the GasAlertMaxXT II detector. Use of any other cell can cause fire and/or explosion. To order and replace the MX-BAT01 battery, refer to Replacement Parts and Accessories.
4

GasAlertMaxXT II Safety Information - Read First aCautions
· Warning: Lithium polymer cells exposed to heat at 266°F (130°C) for 10 minutes can cause fire and/or explosion. · Dispose of used lithium cells immediately. Do not disassemble and do not dispose of in fire. Do not mix with the solid
waste stream. Spent batteries must be disposed of by a qualified recycler or hazardous materials handler. · Keep lithium cells away from children. · Calibration cylinders that are used with a demand flow regulator must meet the following maximum inlet pressure
specifications: · Disposable cylinders 0-3000 psig/70 bar · Refillable cylinders 0-3000 psig/70 bar
5

GasAlertMaxXT II User Manual

Table 1. International Symbols

Symbol
n

Meaning Approved to both U.S. and Canadian Standards by CSA International

g

European Explosives Protection

X

Conforms to European Union Directives

ATEX IECEx EAC Ex

Conforms to European ATEX Directives
International Electrotechnical Commission Scheme for Certification to Standards for Electrical Equipment for Explosive Atmospheres
Conforms to Russian Custom Union Certification and Declaration

Conforms to Korea Testing Laboratory (KTL) Certification

Conforms to Brazilian InMetro Certification

Australian Regulatory Compliance Mark

6

Getting Started
The list below provides the standard items included with the detector. If the detector is damaged or parts are missing, contact the place of purchase immediately.
· Sensors: H2S, CO, O2, and combustible (LEL) · Calibration hose with quick connector · Charging adapter · Quick reference guide · Quick reference card · Technical reference guide on CD-ROM
Note
The IR connectivity kit, which includes the IR Link, is sold separately.
To order parts, refer to Replacement Parts and Accessories.

GasAlertMaxXT II Getting Started
The detector is shipped with the sensors, pump, and rechargeable battery installed. To replace sensors, the pump, or the battery, refer to Replacement Parts and Accessories. For instructions to replace the sensor(s), pump, or battery, refer to the procedures in the following sections:
· Replacement Parts and Accessories · Replacing the Pump · Replacing the Battery To become oriented with the features and functions of the detector, refer to the following figures and tables: · Figure 1. and Table 2. describe the detector's components. · Figure 2. and Table 3. describe the detector's display elements. · Table 4. describes the detector's pushbutton.

7

GasAlertMaxXT II User Manual
Parts of the GasAlertMaxXT II
Figure 1. Parts of the GasAlertMaxXT II 8

Table 2. Parts of the GasAlertMaxXT II

Item

Description

1

Visual alarm indicators (LEDs)

2

Pump quick connector

3

Pump filter and moisture filter

4

Pushbutton

5

Alligator clip

6

Charging connector and IR interface

7

Diffusion cover locking screw

8

Diffusion cover

9

Audible alarm

10

Liquid crystal display (LCD)

Display Elements
Figure 2. Display Elements

Item
1 2 3 4 5 6 7 8 9

GasAlertMaxXT II Display Elements
Table 3. Display Elements
Description
Alarm condition Automatically zero sensor indicator Numeric values Battery life indicator Pump indicator Heartbeat indicator Gas type identifiers Gas cylinder indicator Automatically span sensor indicator

9

Pushbutton
C

GasAlertMaxXT II Display Elements
Table 4. Pushbutton
Description
· To activate the detector press C.
· To deactivate the detector, press and hold C until the OFF countdown is complete and the LCD deactivates.
· To view the date/time, TWA, STEL, and maximum (MAX) readings, press C twice rapidly. To clear the TWA, STEL, and MAX readings, press C when the LCD displays CLEAR ALL.
· To initiate calibration, press and hold C as the detector performs the OFF countdown. Continue holding C while the LCD briefly deactivates and then reactivates to begin the CAL countdown. Release C when the CAL countdown is complete.
· To activate the backlight, press C and release.
· To acknowledge the latched and pump alarms, press C.
· To acknowledge a low alarm and disable the audible alarm temporarily, press C. The Low Alarm Acknowledge option must be enabled in Fleet Manager II.
· To acknowledge any of the Due Today alarms (calibration, bump test, pump block test), press C.

10

GasAlertMaxXT II Activating/Deactivating the Detector

Activating/Deactivating the Detector
Note
Ensure the diffusion cover is attached prior to activating the detector to verify the pump is working correctly.
To activate the detector, press C in a safe area that is free of hazardous gas. Attach any pump accessories to the detector prior to activating the detector.
To deactivate the detector, press and hold C until the OFF countdown completes.
a Caution
The maximum hose length for sampling is 75 ft (22m).

Battery Test
The detector performs a battery test during startup. If the battery has insufficient power to operate, the following screens displays before deactivating.
Recharge the battery for 6 hours and then reactivate the detector. Refer to Charging the Battery.

Startup Tests
When the detector is activated, it performs several startup tests. Confirm the following tests occur.

Audible/Visual Test
1. All of the LCD elements display simultaneously as the detector beeps, flashes, vibrates, and activates the backlight.

11

GasAlertMaxXT II User Manual
Firmware Version
2. The current firmware version installed on the detector displays on the LCD.

Location Logging
4. If the Location Logging option is enabled, the detector prompts for a number (1-999) to be entered that identifies the location (wells, plants, or other areas) where the detector is being used.

Startup Message
3. If enabled and data is entered in Fleet Manager II, a startup message (25 characters per line) displays or scrolls (depending upon length of message) on the LCD. If the startup message option is not enabled, it is bypassed during the startup test.
Refer to Startup Message Top Line in User Options.

Within 3 seconds, press and continue pressing C until the desired number displays. To scroll rapidly, press and hold C.
Note
The site ID number that is entered does not reset when the detector is deactivated. If required, enter a new site ID when the detector is again activated.

12

Pump Test on Startup
Note The diffusion cover must be attached to the detector to activate the pump and initiate the pump test.
a Caution
The maximum hose length for sampling is 75 ft (22m). 5. In cold temperatures, the pump may require a short
period of time to warm up before operating. If this is required, the following screen displays.
The LCD displays a countdown of the time remaining (in seconds) for the pump to warm up. If the Force Block Test option is enabled, the detector performs a pump test. The following screen displays.

GasAlertMaxXT II Startup Tests
Using your finger, block the end of the hose. The following screen displays.
Note If the hose is not blocked and unblocked within 2.5 minutes, the detector will assume the pump has failed and deactivates.
Successful Pump Test: If the pump test is successful, the following screen displays.

13

GasAlertMaxXT II User Manual
Unsuccessful Block Pump Test: If the pump is not operating correctly, the following screens display before the detector deactivates.

When the diffusion cover is replaced, the detector activates the pump alarm.

Activate the detector again. If the pump fails the startup again, refer to Troubleshooting.
If the diffusion cover is not attached, the detector beeps and the following screen displays before continuing with the startup tests.

HIGH displays, and L and J flashes. Press C to acknowledge the alarm and initiate the pump block test.
Alarm Setpoints
Note Alarm setpoints vary by region. Refer to Resetting Gas Alarm Setpoints.
6. If the CO and/or H2S sensor is enabled, the alarm setpoints for the time-weighted average (TWA) and the short-term exposure limit (STEL) display.

14

Next, the LOW and HIGH alarm setpoints display for all of the enabled sensors.

GasAlertMaxXT II Startup Tests
Unsuccessful Self-Test Lockout on Self-Test Error Option Enabled: If this option is enabled and a sensor fails, the following screens display before the detector deactivates.

Self-Test
7. The detector then performs a self-test to ensure it is operating correctly. The following screen displays during the test.
Successful Self-Test: If the self-test is successful, the following screen displays.

If Lockout on Self-Test Error is enabled, the sensor must be replaced to activate and operate the detector. Refer to Replacing a Sensor or Sensor Filter.

15

GasAlertMaxXT II User Manual
Lockout on Self-Test Error Option Disabled: If this option is disabled and a sensor fails the self-test, the LCD displays an error message for the applicable sensor. The startup tests continue.
Note Enabled sensors are continually tested while the detector is operational.
Automatic Zero for H2S, CO, O2, and LEL
Reminder Only activate the detector in a safe area that is free of hazardous gas to ensure an accurate auto zero. 8. To initiate auto zero during startup, the Auto Zero on
Startup option must be enabled (sensors are enabled individually).

If the Force Calibration option is enabled and the sensor(s) is past due for calibration, the sensor will not auto zero during startup. The sensor must be calibrated.
Note If the Auto Zero on Startup option is not enabled in Fleet Manager II for any of the sensors, this startup test is bypassed. If ambient air is set to be measured as 20.8% vol., the automatic oxygen calibration screen displays 20.8% instead of 20.9%.
If Previous Calibration Failed
If the last calibration performed was unsuccessful, the following screens display.
Note BW Technologies by Honeywell recommends the sensor(s) be calibrated immediately.

16

Calibration Due Date (optional)
9. The LCD displays the number of days remaining until the next calibration is due.

GasAlertMaxXT II Startup Tests
Force Calibration Enabled (optional)
10. If the Force Calibration option is enabled in Fleet Manager II and a sensor is past due, the sensor(s) must be calibrated to continue and enter normal operation.

Note
If the Calibration Interval field is set to 0 in Fleet Manager II, it disables the calibration due date function and this test is bypassed. Refer to Calibration Interval in the User Options.
If any sensor is past the calibration due date, the detector beeps, flashes, and vibrates while the LCD displays the following screen.

Press C to acknowledge. Refer to Calibration Procedure to begin calibration. If C is not pressed to enter calibration within 2 minutes, the detector automatically deactivates.

Press C to acknowledge the warning. If C is not pressed within 2 minutes, the detector automatically deactivates.
17

GasAlertMaxXT II User Manual
Cal IR Lock Enabled (optional)
11. If the Cal IR Lock option is enabled in Fleet Manager II, the following screen displays.

If Previous Bump Failed
If the last bump test performed was unsuccessful, the following screens display.

If IR LOCK ENABLED is enabled, the sensor(s) must be calibrated using the IR Link or the MicroDock II station. For more information, refer to Cal IR Lock in User Options.

Note BW Technologies by Honeywell recommends the sensor(s) be bump tested immediately.
Bump Test
Note BW Technologies by Honeywell recommends to bump test the sensors before each day's use to confirm their ability to respond to gas by exposing the detector to a gas concentration that exceeds the alarm setpoints.

18

12. The LCD next displays the number of days remaining until the next bump test is due.
Force Bump Enabled (optional)
If the Force Bump is enabled in Fleet Manager II and a sensor is overdue for a bump test, the sensor(s) must be tested to continue and enter normal operation. The following screen displays.

GasAlertMaxXT II Startup Tests
If Force Bump is disabled, press C to acknowledge the warning and continue with the startup tests.
Note If the bump test interval field is set to 0 in Fleet Manager II, the startup bump test is bypassed. Refer to Bump Interval in the Device Configuration.
The detector remains in alarm until the gas dissipates and clears from the sensors. Verify that the visual and audible alarms activate.
Startup Test Pass
If the detector passes all of the startup tests, the detector enters normal operation and displays the ambient gas readings.

Apply gas while BUMP DUE NOW displays. Verify the visual, audible, and vibrator alarms activate. The detector must enter alarm to pass the bump test. For complete instructions, refer to Bump Test.

The detector begins recording the maximum gas exposure (MAX), and calculating the short-term exposure level (STEL) and time-weighted average (TWA) exposures.

19

GasAlertMaxXT II User Manual Startup Test Fail
After the detector enters normal operation, ERR displays if a sensor has failed the self-test. To determine the cause and solutions for a failed sensor, refer to Troubleshooting.
20

Installing Fleet Manager II
Fleet Manager II is required to configure the detector. To install Fleet Manager II, refer to the Fleet Manager II CD-ROM that includes the
· installation wizard, and
· Fleet Manager II Operator's Manual.
From the User Options tab in Fleet Manager II, two sections are provided to add data, enable/disable features, and to define settings for the sensors and the detector. They are as follows:
· Device Configuration
· Sensor Configuration

Using Fleet Manager II to Configure the Detector

When Fleet Manager II is installed, refer to Table 5., Figure 3., and the following procedures:
Table 5. Connecting the IR Link

Item 1 2 3 4

Description IR and charger interface GasAlertMaxXT II IR Link USB cable

GasAlertMaxXT II Installing Fleet Manager II
Figure 3. Connecting the IR Link 1. Activate the detector and wait for the startup tests to
complete. 2. Connect the USB cable to the USB port on the computer. 3. Connect the USB cable to the IR Link. 4. Insert the IR Link into the IR interface on the back of the
detector. 5. From the PC, open Fleet Manager II. 6. Click Administration. 7. From the Administration toolbar, click Login / Logout
to access the Enter Password dialog box. Enter Admin and click OK.
21

GasAlertMaxXT II User Manual
8. From the Devices toolbar, click Configure Device via IR Link to access the GasAlertMaxXT Configuration window.
9. From the configuration window, click Retrieve from Device at the bottom of the window.
10. Refer to the following sections in this guide for descriptions about how to enter data, enable/disable, and define settings.
11. When all settings are defined, click Save to Device at the bottom of the configuration window to save the configuration to the detector.

Device Configuration
The Device Configuration section displays data about the detector, allows for a startup message to be entered, and is used to enable/disable and define settings for the detector.

Figure 4. Device Configuration Section 22

Refer to the following options for descriptions and functionality.
Note The Serial Number, Firmware Version, and Hardware Version fields require no data entry. Settings for these fields are factory defined.
Serial Number Field
This field displays the serial number (e.g. MA110-001000) of the detector.
Firmware Version
This field displays the current firmware version (e.g. 02_000) that displays on the detector LCD during the startup tests. If new firmware is uploaded to the detector, the Firmware Version field automatically updates.
Hardware Version
This field displays the current version of hardware the detector is operating with.
Startup Message Top Line
Enter a line of text that will display on the detector LCD during startup (maximum 25 characters, spaces included). Enter any type of information such as employee name, plant, area, emergency number(s), etc. Depending upon the length of the message, text will either display or scroll across the top line of the LCD.

GasAlertMaxXT II Device Configuration
Startup Message Bottom Line
Enter a line of text that will display on the detector LCD during startup (maximum 25 characters, spaces included). Enter any type of information such as employee name, plant, area, emergency number(s), etc. Depending upon the length of the message, text will either display or scroll across the bottom line of the LCD. The user options define the settings for the detector.
Note When options are enabled/disabled, the checkbox displays with a red frame until the new settings are saved to the detector.
Lockout on Self-Test Error (failed sensor lock)
If enabled and a sensor fails during startup, the following screens display and the detector deactivates.
To enter normal operation, the sensor must be operating correctly. Refer to Troubleshooting and Replacing a Sensor or Sensor Filter. The detector is shipped with the Lockout on Self-Test Error option disabled.

23

GasAlertMaxXT II User Manual
Safe Mode
If enabled, SAFE displays continuously on the LCD unless an alarm condition occurs.

display the high peak concentration until the alarm condition no longer exists. The detector is shipped with the Latching Alarms option disabled.
Force Calibration
Force Calibration Enabled: If enabled and a sensor(s) is past due for calibration, the following screen displays.

If an alarm condition occurs, the LCD displays the real-time readings for each sensor.

Confidence Beep
If enabled, the confidence beep provides continuous confirmation that the detector is operating correctly. To define how often the detector beeps (every 1-120 seconds), enter the value in the Confidence Interval field.
Note
Confidence beep automatically disables during a low battery alarm.
The detector is shipped with the Confidence Beep option disabled.
Latching Alarms
If enabled, a detector alarm persists until the alarm is acknowledged and gas concentrations are below the low alarm setpoint. The audible alarm can be temporarily deactivated by pressing C, but the LCD continues to

The sensor(s) must be calibrated to continue and enter normal operation. For complete instructions, refer to Calibration.
Note
If the calibration is unsuccessful for any of the sensors, the detector deactivates.
Force Calibration Disabled: If disabled, the CAL DUE NOW screen displays. Press C to acknowledge the warning and enter normal operation.
The detector is shipped with the Force Calibration option disabled.
Note
If overdue for calibration, BW recommends the sensor(s) be calibrated immediately.

24

GasAlertMaxXT II Device Configuration

Force Bump
A bump test must be performed regularly to ensure the sensor(s) are responding correctly to test gas. If enabled and the sensor(s) is past due, a bump test must be performed and the overdue sensor must enter into alarm. If this option is enabled, the following screen displays during the startup tests.

Cal IR Lock
If enabled, the sensor(s) can only be calibrated using the IR Link with Fleet Manager II or the MicroDock II station. If the Cal IR Lock option is enabled, the following screen displays.

If Force Bump is enabled, enter a value (1-365) in the Bump Interval (days) field located in the Sensor Configuration section.
If 0 is entered in the Bump Interval (days) field, the Force Bump option is automatically disabled.
Note
BW recommends to bump test the sensors before each day's use to confirm their ability and response to gas by exposing the detector to a gas concentration that exceeds the high alarm setpoints. Verify that the audible and visual alarms activate. Calibrate if the readings are not within the specified limits.
For complete instructions to perform a bump test, refer to Bump Test.
The detector is shipped with the Force Bump option disabled.

Note
The auto-zero function is not affected if the CAL IR Lock option is enabled. The detector still performs the auto-zero function (if enabled).
To calibrate using an IR device, refer to one of the following: · Calibrating Using the IR Link · MicroDock II Base Station User Manual
The detector is shipped with the CAL IR Lock option disabled.
Note
If the Cal IR Lock option is enabled and a manual calibration is attempted, the sensor(s) will only auto zero. Calibration will not be performed.

25

GasAlertMaxXT II User Manual

Location Logging
The Location Logging logs where the detector is being used such as a gas plant, well site, vehicle, etc.
If enabled, the detector prompts for a three digit value (1-999) to be entered during the startup tests.

Force Block Test
The force block test verifies the pump is operating correctly by comparing the pump flow against the blocked flow. If the Force Block option is enabled, you will be prompted to manually block the pump inlet
· during the startup tests when the detector is activated, and · when a pump alarm is acknowledged.

To enter a number from 1-999, continue pressing C until the desired number displays. To scroll rapidly, press C and hold.
The location entries are recorded in the datalogs. The detector is shipped with the Location Logging option disabled.

a Caution
The diffusion cover must be attached for the pump to operate. If the block pump test is unsuccessful, the detector deactivates. For more information about the block test that is performed during startup, refer to Pump Test on Startup. The detector is shipped with the Force Block Test option disabled.
Datalog Interval
The Datalog Interval (seconds) field defines how often the detector records a datalog sample (every 1-120 seconds). Enter the desired value.

26

Confidence Interval
The Confidence Interval (seconds) field defines how often the confidence beep occurs (detector beeps). Enter the desired value (every 1-120 seconds). The Confidence Beep option must be enabled.
Language
The Language field provides a drop down menu that includes the following language options:
· English · Français · Deutsch · Español · Português From the drop down menu, select the required language. When the settings are saved to the detector, the LCD displays all screens in the selected language.

GasAlertMaxXT II Sensor Configuration
Sensor Configuration
The Sensor Configuration tab adjusts settings for each individual sensor. A separate sensor tab is provided for each sensor. Figure 5. shows the available option settings for the H2S sensor.

The detector is shipped with English displaying as the default language.

Figure 5. Sensor Configuration Tab (H2S) Note
Depending upon the sensor, the options may vary.
27

GasAlertMaxXT II User Manual
Sensor Disabled a Warning
Use extreme caution when disabling a sensor. The disabled sensor cannot detect and alarm against the applicable gas. To disable a sensor, complete the following: 1. Click Retrieve from Device to populate the fields with
the current detector settings. 2. Click the tab of the sensor to be disabled. 3. Click the checkbox for Sensor Disabled.
Note When options are enabled/disabled, the checkbox displays with a red frame until the new settings are saved to the detector.
4. Click the Save to Device button located at the bottom of the window.

5. The LCD automatically updates. In the following example, the CO gas type and sensor readings no longer displays.
Calibration Gas (ppm) a Warning
The gas concentration value entered in Fleet Manager II must match the gas concentration value on the gas cylinder. 1. Select the applicable sensor tab. 2. Enter the gas concentration value in the Calibration Gas
(ppm) field for H2S and CO. 3. Enter the gas concentration value in the Calibration Gas
(%) field for O2 and LEL. Note
The gas concentration value for the O2 sensor must be calibrated with a %value other than 20.9 or 20.8%, such as 18%.

28

GasAlertMaxXT II Sensor Configuration

Calibration Interval
Define how often a sensor must be calibrated in the Calibration Interval (days) field. A different calibration interval can be set for each sensor.
1. Enter the value (0-365 days) for each sensor. 2. Enter 0 to disable the calibration interval option. Entering
0 automatically deactivates the Force Calibration user option.
Note
BW recommends that the detector be calibrated at least once every 180 days (6 months).
The detector is shipped with the factory default set to 180 days.

setpoints. Verify that the audible and visual alarms activate. Calibrate if the readings are not within the specified limits.
Low Alarm
Enter the low alarm setpoints for each sensor (applicable to all sensors). Refer to Resetting Gas Alarm Setpoints for factory defined alarm setpoints.

Bump Interval
Define how often a bump test must be performed for each sensor in the Bump Interval (days) field. A different bump interval can be set for each sensor.
1. Enter the value (1-365 days) for each sensor.
2. Enter 0 to disable the bump interval option. Entering 0 automatically deactivates the Force Bump user option.
The detector is shipped with the Force Interval option disabled.
Note
BW recommends to bump test the sensors before each day's use to confirm their ability and response to gas by exposing the detector to a gas concentration that exceeds the high alarm

High Alarm
Enter the high alarm setpoints for each sensor (applicable to all sensors). Refer to Resetting Gas Alarm Setpoints for factory defined alarm setpoints.

29

GasAlertMaxXT II User Manual

TWA Alarm
The time-weighted average (TWA) is a safety measure used to determine accumulated averages of gases. An average is determined using the Occupational Safety and Health Administration (OSHA) method to ensure the worker leaves an area when the maximum average is accumulated.
OSHA: The OSHA method is defined as a moving average that accumulates over an 8-hour average. If the worker is in the field longer, the oldest accumulated values (first hour) are replaced by the newest values (ninth hour). This continues for the duration of the work shift until the detector is deactivated.
1. Refer to Resetting Gas Alarm Setpoints for factory alarm setpoints.
2. Enter the TWA alarm setpoint for the H2S and the CO sensor in the TWA Alarm (ppm) field. TWA is not applicable to O2 and LEL.

STEL Alarm
The short term exposure limit (STEL) is the maximum permissible gas concentration a worker can be safely exposed to for short periods of time (5-15 minutes maximum).
Note
Standard factory alarm setpoints vary by region. Refer to Resetting Gas Alarm Setpoints for OSHA factory settings.
1. Refer to the applicable regulatory requirements in your area for defining STEL alarm setpoints.
2. Enter the setpoint in the STEL Alarm (ppm) field.

3. After entering the STEL setpoint, the STEL interval value (5-15 minutes) must be entered. Refer to STEL Interval.

3. Enter a value (4-16 hours) in the TWA Period (hours) field to define the duration of the moving average. For more information, refer to TWA Period (hours).
30

GasAlertMaxXT II Sensor Configuration

STEL Interval
The STEL Interval option provides protection for workers from over exposure to high concentrations of gas, and is based on user-defined 5-15 minute intervals. When the maximum STEL is reached, the detector alarms to notify the worker to leave the area immediately.
a Caution
Follow all safety procedures as defined by your employer.
Enter the interval (5-15 minutes) in the STEL Interval (minutes) field. The detector is shipped with the STEL interval set to 15 minutes.
TWA Period (hours)
The TWA Period (hours) option defines a time-weighted moving average of accumulated gases over a period of 4-16 hours, to ensure the worker leaves an area when the defined maximum average is accumulated. Example: The TWA Period option is set to 6 hours. Therefore, the moving average accumulates over a 6-hour average. If the worker is in the field longer, the oldest accumulated values (first hour) are replaced by the newest values (seventh hour). This continues for the duration of the work shift until the detector is deactivated.

Note Regulations vary depending upon region. Adhere to the regulations defined for your area. Enter a value ranging from 4-16 hours. The detector is shipped with the default setting of 8 hours.
Correction Factor (%)
The Correction Factor (%) option is used to enter compensation factors for hydrocarbons other than methane. The correction factor is only applicable to LEL and can only be applied if the LEL sensor has been calibrated with methane.
a Caution
Ensure the calculations are correct for the applicable gas to ensure the reading display as 100% LEL. Enter a K-factor (industry standard decimal value) in the Correction Factor (%) field. Values can range from 0.50 - 4.00.
Note Not applicable to a % by vol CH4 measuring mode. The detector is shipped with the factory default set to 100%.
31

GasAlertMaxXT II User Manual

50% LEL = (%CH4)
If the LEL By Volume CH4 option is enabled, a percentage value can be entered in the 50% LEL = (%CH4) field to display the LEL reading in %vol. assuming a methane environment. Enter the equivalent methane concentration for 50% LEL as follows:
· North America = 2.5% · Europe = 2.2% This option is only applicable to the LEL sensor.
Auto Zero on Startup
When enabled, the sensors automatically zero during the startup tests. The Auto Zero on Startup option is available for the CO, H2S, LEL, and O2 sensors. The detector is shipped with the Auto Zero on Startup option enabled for all sensors.
LEL by Volume CH4
If enabled, the detector LCD displays the LEL value as %vol. assuming a methane environment. If LEL by Volume CH4 is enabled, a percentage value must be entered in the 50% LEL = (%CH4) field. Refer to 50% LEL = (%CH4).

10% (of reading) Over-span
When enabled, the detector automatically over-spans the LEL sensor by 10% of the span concentration to ensure the span meets CSA standards. After enabling this option in Fleet Manager II, a calibration (manual or using the MicroDock II) must be completed to fully enable this option.
20.8 Base Reading
If the 20.8 Base Reading option is enabled, the detector assumes 20.8 % O2 as ambient air (factory default is 20.9% O2). The detector is shipped with this option disabled.
Low Alarm Acknowledge
If enabled, the audible alarm can be disabled during a low alarm condition. The LED and visual alarm indicators remain active until the the alarm condition changes or the detector deactivates. Press C to acknowledge the low alarm and deactivate the audible alarm.
Note The Low Alarm Acknowledge option is not applicable to O2.
The detector is shipped with the Low Alarm Acknowledge disabled.

32

GasAlertMaxXT II User Manual

Alarms
Table 7 describes the detector alarms and corresponding screens. During an alarm condition, the detector activates the backlight, audible/visual/ vibrator alarms, and displays the current ambient gas reading. If more than one type or level of alarm exists simultaneously, a multi-gas alarm results.
To change the factory-defined alarm setpoints, refer to Low Alarm, High Alarm, TWA Alarm, and STEL Alarm in Device Configuration.
Table 6. Alarms

Low Alarm · Slow siren

Alarm

Screen

TWA Alarm · Fast siren

Alarm

Screen

· Slow alternating flash

· Fast alternating flash

· L and target gas bar flash

· L and target gas bar flash

· Vibrator alarm activates
High Alarm · Fast siren

· Vibrator alarm activates
STEL Alarm · Fast siren

· Fast alternating flash

· Fast alternating flash

· L and target gas bar flash

· L and target gas bar flash

· Vibrator alarm activates

· Vibrator alarm activates

Note
If the Low Alarm Acknowledge option is enabled, the audible alarm can be disabled during a low alarm condition. The LED and visual alarm indicators remain active until the alarm condition changes or the detector deactivates. Press C to acknowledge the low alarm and deactivate the audible alarm. If the alarm escalates to a high, TWA, or STEL alarm, the audible alarm reactivates.

33

GasAlertMaxXT II Alarms

Alarm
Multi-Gas Alarm · Alternating low and high alarm siren and flash
· L and target gas bar flash
· Vibrator alarm activates

Table 7. Alarms
Screen
Sensor Alarm · ERR displays

Alarm

Screen

Over Limit (OL) Alarm · Fast siren and alternating flash
· L and target gas bar flash
· Vibrator alarm activates

Low Battery Alarm
· Sequence of 10 rapid sirens and alternating flashes with 7 seconds of silence in between (continues for 10 minutes)

·

and L flashes

· LOW BATTERY displays and the vibrator alarm activates

· After 10 minutes, a sequence of 10 rapid sirens and alternating flashes with 1 second of silence in between (reactivates seven times)

· TURNING OFF displays before the detector deactivates

Note
If enabled, during an alarm condition the Latched Alarms option causes the low and high gas alarms (audible, visual, and vibrator) to persist until the alarm is acknowledged (by pressing C) and the gas concentration is below the low alarm setpoint. The LCD displays the peak concentration until the alarm condition no longer exists. Enable/disable Latching Alarms in Fleet Manager II. Local regulations may require Latching Alarms be enabled.
34

GasAlertMaxXT II User Manual
Alarm
Automatic Deactivation Alarm · Sequence of 10 rapid sirens and alternating
flashes with 1 second of silence in between (reactivates seven times)
· L flashes and the vibrator alarm activates
· TURNING OFF displays before the detector deactivates
Normal Deactivation · Four beeps and flashes
· Vibrator alarm activates briefly
· Countdown initiates
Pump Alarm · Two beeps and flashes · J and L flashes
· HIGH displays · Vibrator alarm activates

Table 7. Alarms

Screen

Alarm

Confidence Beep · One beep every 1-120 seconds (user-defined)

Note
Confidence beep automatically deactivates during a low battery alarm.

Screen

Heartbeat

·

flashes once every second

35

GasAlertMaxXT II User Manual

Computed Gas Exposures
a Warning
To prevent possible personal injury, do not deactivate the detector during a work shift. TWA, STEL, and MAX readings reset when the detector is deactivated.
Table 7. Computed Gas Exposures

Gas Exposure

Description

TWA (H2S and CO only)

Time-weighted average (TWA) based on accumulated exposure to toxic gases averaged over a workday according to OSHA method.
Default: OSHA 8 hour moving average.
User-defined: 4-16 hour moving average.

STEL (H2S and CO only)

Short-term exposure limit (STEL) to gas based on a 5-15 minute user-defined period.

Maximum* (peak)

Maximum (MAX) concentration encountered during work shift.

* For oxygen, it is the highest or the lowest concentration encountered.

36

Viewing and Clearing Gas Exposures
To view the TWA, STEL, and maximum (MAX) readings, press C twice rapidly. The LCD first displays the current time and date.
Then, the TWA gas exposures display.
Next, the STEL gas exposures display.

Next, the MAX readings display.
Last, the CLEAR ALL readings screen displays. To clear the TWA, STEL, and MAX exposure readings, press C when the following screen displays.
a Warning
Follow all safety procedures as defined by your employer. Deactivating the detector clears all readings. Confirm with your supervisor before clearing TWA and STEL alarms.

GasAlertMaxXT II Computed Gas Exposures

Gas Alarm Setpoints
The alarm setpoints trigger the gas alarms and are described Table 8. Table 8. Gas Alarm Setpoints

Alarm

Condition

Low alarm
High alarm TWA alarm STEL alarm Multi-gas alarm

Toxics and combustibles: Ambient gas level above low alarm setpoint.
Oxygen: Ambient gas level may be
set above or below 20.9% (or 20.8%).
Toxics and combustibles: Ambient gas level above high alarm setpoint. Oxygen: Ambient gas level may be set above or below 20.9% (or 20.8%).
Toxic only: Accumulated value above the TWA alarm setpoint.
Toxic only: Accumulated value above the STEL alarm setpoint.
Two or more gas alarm conditions simultaneously.

37

GasAlertMaxXT II User Manual

Resetting Gas Alarm Setpoints
Table 9. lists alarm setpoints as defined by Occupational Safety and Health Association (OSHA).
Note Standard factory alarm setpoints vary by region.
Table 9. Sample Factory Alarm Setpoints

Gas

TWA

STEL

Low

High

O2

N/A

N/A

LEL N/A

N/A

19.5% vol. 10% LEL

23.5% vol. 20% LEL

CO

35 ppm 50 ppm

35 ppm

200 ppm

H2S

10 ppm

15 ppm

10 ppm

15 ppm

Note To disable an alarm, set the alarm setpoint to 0 (zero) in Fleet Manager II.
To change the factory-defined alarm setpoints, refer to the following in User Options:
· Low Alarm · High Alarm · TWA Alarm · STEL Alarm
38

Stopping a Gas Alarm
The low and high alarms stop when the ambient gas concentrations returns to a concentration below the low alarm setpoint.
Note
If alarms are set to latch, press C to reset the alarms.
The detector computes the TWA value based on OSHA standards and the STEL value based on a user-defined 5 to 15 minute interval. Refer to STEL Interval.
The TWA and STEL alarms can be stopped either by
· deactivating and then reactivating the detector, or · clearing the TWA/STEL/MAX exposure readings. Refer to
Viewing and Clearing Gas Exposures.
a Caution
Follow all safety procedures as defined by your employer. Confirm with your supervisor before clearing TWA and STEL alarms.
Sensor Alarm
The detector tests for missing or defective sensors during the startup self-test and continuously thereafter. If a sensor fails the self-test, Err displays above the gas type of the failed sensor. If a sensor fails, refer to Troubleshooting.

Pump Alarm
The pump draws air over the sensors continually. If the pump stops operating or becomes blocked, the detector activates the pump alarm.

GasAlertMaxXT II Computed Gas Exposures
Low Battery Alarm
The detector tests the battery on activation and continuously thereafter. Battery power is continually displayed during normal operation. If the battery voltage is low, the detector activates the low battery alarm.

During a pump alarm, HIGH and L display, and J flashes.
Note
The pump alarm displays the same as a high alarm, except that J flashes. Verify that a pump alarm is occurring before clearing the hose.
The pump alarm continues until the alarm is acknowledged by pressing C.
1. Clear the blockage and press C to acknowledge. If Force Block Test is enabled, the detector automatically launches a pump test to verify the pump is operating correctly.
2. If the pump test is successful, the detector returns to normal operation.
If the pump test is unsuccessful, refer to Troubleshooting for possible causes and solutions.

The low battery alarm continues 10 minutes. If the battery voltage drops too low, the detector activates the automatic deactivation alarm.
Automatic Deactivation Alarm
If the battery is depleted below the minimum operating voltage, a sequence of ten sirens and alternating flashes activates with 1 second of silence in between. The sequence repeats seven times. The following screens displays and the detector deactivates.
To charge the detector, refer to Charging the Battery.
39

GasAlertMaxXT II User Manual
Bump Test
A bump test is the process of applying a small amount of test gas to force the detector into alarm.
Perform a bump test to validate that the sensors are responding correctly to gas, and that the audible and visual alarms activate during an alarm condition.
To perform a bump test, complete the following:
1. Activate the detector. A bump test can be performed either during startup when the BUMP DUE NOW screen displays or when in normal operation.

4. The detector should enter alarm. Verify the audible and visual alarms activate, and that the LCD readings match the span gas concentrations of the gas cylinder being used.
5. Disconnect the calibration hose from the detector. The detector briefly remains in alarm until the sensors clear of the test gas.
Note
A MicroDock II station (automated bump test) is required to log bump tests as an event. A manual bump test will not be logged as an event.
Bump Test Using the MicroDock II Station
To perform an automated bump test, refer to the MicroDock II User Manual.

2. Attach the calibration hose to a 0.5 l/min regulator or a demand flow regulator.
3. Connect the hose quick connector to the pump quick connector on the pump inlet to apply gas.

40

Calibration
Guidelines
Recommended gas mixture: CO: 100 ppm balance N2 H2S: 25 ppm balance N2 LEL: 50% LEL or 2.5% by vol. methane balance air O2: clean air, 18%
· To ensure accurate calibration, use a premium-grade calibration gas. Gases approved by the National Institute of Standards and Technology (NIST) improve the validity of the calibration.
· Do not use a gas cylinder past its expiration date.
· Calibrate a new sensor before use. Install the sensor, activate the detector, and allow the sensor to stabilize before starting calibration or a bump test. Used sensor: 60 seconds / new sensor: 5 minutes.
· Calibrate the detector at least once every 180 days, depending upon use and sensor exposure to poisons and contaminants.
· Calibrate the detector if the ambient gas varies during startup.
· Calibrate only in a safe area that is free of hazardous gas.
· Do not calibrate the detector during or immediately after charging is complete.
· The H2S, CO, LEL and O2 sensors can be automatically zeroed each time the detector is activated if the Auto-Zero on Startup option is enabled. Activate the detector in a normal (20.9%/20.8% O2) atmosphere.

GasAlertMaxXT II Calibration
· If a certified calibration is required, contact BW Technologies by Honeywell.
· Calibration can be performed using either a 0.5 l/min regulator or a demand flow regulator.
· The maximum hose length for calibration is 3 ft (0.9 m). a Warning
Calibration cylinders that are used with a demand flow regulator must meet the following maximum inlet pressure specifications:
· Disposable cylinders 0-1000 psig/70 bar · Refillable cylinders 0-3000 psig/70 bar BW recommends using premium grade calibration gases and cylinders that are certified to National Standards. The calibration gases must meet the accuracy of the detector.
41

GasAlertMaxXT II User Manual

Diagnostics Protection
The detector tests the ambient air (auto-zero) and the test gas that is applied (auto span) to ensure it meets expected values. Auto-zero sets the zero-gas level of the sensor. If the target gas is present, the zero level will be incorrect. If excessive target gas is present, the sensor(s) will fail and an error message displays.
In auto span, an error message displays if the target gas does not meet the expected values.

Connecting the Gas Cylinder to the Detector
Refer to the following procedures and Figure 6. to connect the gas cylinder to the detector for calibration.
Note
Read all of the following procedures before beginning calibration.
a Caution
The maximum hose length for calibration is 3 ft (0.9 m). 1. Verify the calibration gas being used matches the span
concentration value(s) that are set for the detector.
2. Attach a 0.5 l/min regulator or a demand flow regulator to the gas cylinder.
3. Connect the calibration hose to the regulator on the gas cylinder.
4. Begin the calibration procedures. Refer to the Calibration Procedure section.

Sensor(s) that fail to span retain the previous span value and do not continue the calibration process.

42

5. When calibration is complete, disconnect the hose from the detector and the regulator.
6. Ensure the gas cylinder is stored according to the manufacturer's specifications.

GasAlertMaxXT II Calibration
Calibration Procedure
a Caution
Calibrate only in a safe area that is free of hazardous gas. Do not calibrate the detector during or immediately after charging.
Note
Calibration can be aborted at any time. To abort calibration, press C. The following screen displays.

To calibrate the sensor(s), complete the following: 1. Activate the detector. 2. Ensure the sensor(s) to be calibrated is enabled in Fleet Manager II. 3. Verify the calibration gas being used matches the span concentration value(s) that are set for the detector.
Figure 6. Connecting the Gas Cylinder to the Detector
43

GasAlertMaxXT II User Manual
4. Press and hold C while the detector performs the OFF countdown. Continue to hold C as the detector briefly deactivates.

flashes while the detector automatically zeroes the combustible and toxic sensors, and calibrates the oxygen sensor.

The detector then reactivates and performs the calibration countdown. Continue to hold C until the countdown is complete.

When auto zero is complete, the detector beeps two times.
Auto Zero Successful: If the sensor(s) successfully zeroes, the detector automatically proceeds to the Auto Span function.
Auto Zero Unsuccessful: If a sensor(s) fails auto zero, an error message and which sensor(s) failed displays.

Note If C is not held for the entire countdown, the detector will deactivate.
Auto Zero Sensor
Note Do not apply calibration gas until Apply Gas displays, otherwise the auto zero function will fail.
44

To determine the cause and solutions for the failed sensor(s), refer to Troubleshooting.

Auto Span

When auto zero is complete, APPLY GAS and

display, and

flashes.

GasAlertMaxXT II Calibration
Unsuccessful Span If the sensor(s) fails the span, the following screen displays.

5. Connect the calibration hose to the regulator on the gas cylinder (Figure 6.).

6. Attach the hose quick connector to the pump quick connector to apply gas.

After 50% of the gas is detected on all sensors (within 30

seconds),

continues to flash while the detec-

tor completes the span (approximately 2 minutes).

Successful Span

7. If the sensors have successfully passed the span, the audible alarm beeps and continues with calibration. Proceed to Calibration Due Date.

Refer to the following for possible causes and solutions.
The detector will not span a sensor if
· gas is not applied to the sensor,
· 50% of the expected gas concentration is not detected within the first 30 seconds, or
· the gas concentration drops below 50% of the expected gas level during the 2-minute span.
If gas is applied to a sensor and the detector fails to span the sensor, perform the following:
· Repeat the calibration using a new gas cylinder.
· Repeat the calibration using a new 0.5 l/min regulator or a new demand flow regulator.
· If the sensor fails the span a second time, replace the sensor. Refer to Replacing a Sensor or Sensor Filter.

45

GasAlertMaxXT II User Manual
If a sensor(s) fails any step of the calibration, the following screen displays.

Calibration Due Date
If a sensor(s) does not successfully span, the calibration due date for that sensor(s) will not reset.

Note
If calibration is unsuccessful for a sensor(s), the calibration due date cannot be set for the failed sensor(s).

46

After the span is complete, the following calibration due date screens display before returning to normal operation.

GasAlertMaxXT II Calibration
If a sensor fails to span successfully and it is past the calibration due date, the following screens display.

The number of days that displays in the CAL DUE XXX DAYS screen is the earliest date (overall of all sensors) a calibration must be performed.
Example: The H2S sensor has the earliest date. The H2S sensor must be calibrated in 65 days.

The example above shows the CO sensor is 6 days past due.
8. Press C to acknowledge the warning before returning to normal operation. Refer to Troubleshooting and calibrate the failed sensor again.
Verification
1. After calibration is complete and the detector returns to normal operation, verify the calibration using a gas cylinder other than the one used for calibration.
2. The gas concentration should not exceed the sensor's detection range. Confirm that the LCD shows the expected concentration values.

47

GasAlertMaxXT II User Manual
3. To ensure the readings are accurate, apply the verification gas for the same amount of time as was applied to the sensor when it was calibrated. Example: H2S span time 2 minutes therefore, apply verification gas for 2 minutes.
Calibrating Using the IR Link
If the Cal IR option is enabled, the sensors must be calibrated using either the IR Link or MicroDock II station.

To calibrate using the IR Link, complete the following:
1. From the PC, open Fleet Manager II.
2. Click Administration.
3. From the Administration toolbar, click Login / Logout to access the Enter Password dialog box. Enter Admin and click OK.
4. From the Devices toolbar, click Detector Configuration.
5. Activate the detector.
Calibration can be performed during the startup tests when CAL DUE NOW displays, or when the detector in normal operation.
6. From Fleet Manager II, click the Calibrate button located at the bottom of the window.
The Calibrate Device dialog box displays.

Figure 7. Calibrate Device Dialog Box 48

7. Enter the span gas concentration values. The values entered in the Calibrate Device popup must match the span concentration values on the gas cylinder.
8. Click inside the checkbox for each sensor that will be calibrated, and then click Calibrate. The following screen displays.
9. Refer to Auto Span to complete calibration. Note
To calibrate using the MicroDock II, refer to the MicroDock II User Manual and the Fleet Manager II Operator's Manual.

GasAlertMaxXT II Calibration
49

GasAlertMaxXT II User Manual
Event Logs
The detector records the thirty most recent gas alarm events. Information that is recorded from an event is as follows:
· Serial number of the detector · Start time of alarm · Type, level, and duration of alarm · Status of sensor · Peak exposure level (ppm or %) · Status of the detector · Detector user · Supervisor · Location · Definables (employee information)
Datalogs
The detector records datalog samples that can be compiled to create a report using Fleet Manager II. From Fleet Manager II, define how often the detector records a datalog sample (1-120 seconds) in the Datalog Interval (seconds) field. The detector is capable of storing 6 hours to 5 years of information, depending upon the datalog interval and what information is stored. When the memory is full, the detector replaces the oldest datalogs with the most recent datalogs.

The following information is recorded in a datalog: · Serial number of the detector · Date and time · Type of datalog · Detector status · Detector user · Type of gases the detector monitors · Gas readings · STEL and TWA readings (H2S and CO only) · Alarm setpoints · Options enabled/disabled · Sensor status · Pump status · Logging intervals · Language detector is set to display · Calibrations performed · Bump tests performed · Battery readings · Temperature readings

50

Bump and Calibration Results
The detector records the bump test and calibration results. The results can then be imported into Fleet Manager II to create detailed reports. The following information is recorded in the Bump/Calibration datalogs:
· Date/time bump tests and calibrations were performed · Serial number of the detector · Test performed · Test results · Detector user · Supervisor · Detector status · Detector configuration updated during bump test/calibration · Type of detector · Location detector was used · MicroDock II serial number · MicroDock II location · Last calibration performed · Next calibration due date · Last bump test performed · Next bump test due date · Datalog interval · STEL period · Pump enabled/disabled

GasAlertMaxXT II Bump and Calibration Results
· Audible and visual indicator status · Sensor type and sensor status · Alarm status · Sensor status · Inlet(s) used · Definables (employee information)
Downloading Datalogs and Event Logs
The datalog and event log files can only be downloaded to a PC using the IR Link or the MicroDock II Base Station. Refer to the Fleet Manager II Operator's Manual.
Software Requirements
Fleet Manager II and Excel software are required to create spreadsheet reports of the event logs, datalogs, and bump and calibration results.
51

GasAlertMaxXT II User Manual
Maintenance
To maintain the detector in good operating condition, perform the following basic maintenance as required.
· Calibrate, bump test, and inspect the detector at regular intervals. · Maintain an operations log of all maintenance, bump tests,
calibrations, and alarm events. · Clean the exterior with a soft damp cloth. Do not use solvents,
soaps, or polishes. · Do not immerse the detector in liquids.
Maximum Hose Length for Sampling
The maximum hose length for sampling is 75 ft (22m).
Battery Maintenance and Cautions a Warning
To avoid personal injury and/or property damage, adhere to the following: · The detector must be deactivated to charge the battery. · Charge the battery immediately when the detector emits a low battery alarm. Refer to Charging the Battery. · Charge the battery using the GasAlertMaxXT II or the GasAlertMicroClip charger adapter only. Do not use any other charger adapters. Failure to adhere to this precaution can lead to fire and/or explosion.
52

· Do not calibrate the detector during or immediately after charging the battery.
· Warning: The GasAlertMaxXT II uses a lithium battery (MX-BAT01) that may present a risk of fire or chemical burn hazard if misused. Do not disassemble, heat above 212° (100°C), or incinerate.
· Warning: Lithium polymer cells exposed to heat at 266°F (130°C) for 10 minutes can cause fire and/or explosion.
· If replacing the battery, use only approved lithium polymer cells that are available through BW Technologies by Honeywell. Use of any other cell can cause fire and/or explosion. To order and replace the MX-BAT01 lithium battery, refer to Replacement Parts and Accessories.
· Replace the battery only in a safe area that is free of hazardous gas.
· Dispose of used lithium cells immediately. Do not disassemble and do not dispose of in fire. Do not mix with the solid waste stream. Spent batteries must be disposed of by a qualified recycler or hazardous materials handler.
· Keep lithium cells away from children.

Charging the Battery Figure 8. Connecting the Charger Adapter

GasAlertMaxXT II Maintenance

Table 10. Connecting the Charger Adapter

Item 1 2 3 4

Description IR and charger interface GasAlertMaxXT II Charger adapter Charger cable

a Warning
The detector must be charged in a safe area that is free of hazardous gas in temperatures of 32°F to 113°F (0°C to 45°C).
To charge the battery, refer to Figure 8., Table 10. and the following procedures:
1. Deactivate the detector.
2. Plug the charger into a AC outlet.
a Caution
The charging adapter is voltage specific to your region. Use of the charging adapter outside your region will damage the charger and the detector.
3. Attach the charging adapter (Figure 8.) to the charger interface.

53

GasAlertMaxXT II User Manual

4. Allow the battery to charge for 6 hours. The charging indicator flashes (low, mid, and full charge repeatedly) on the LCD while the battery is charging.
low mid full
5. When charging is complete, the charging indicator stops flashing and displays to indicate a full charge. Remove the adapter and activate the detector. If the battery indicator does not display, refer to Troubleshooting.
Note To preserve the life of the battery, deactivate the detector when not in use.
The detector may be warm immediately after charging. This is normal.
Optimum Battery Operation
To ensure maximum use of the battery, perform the following: · To obtain full operating capacity, allow the battery to fully charge and discharge three times. · To achieve the maximum number of charges, ensure the battery is charged between 32°F and 113°F (0°C and 45°C). Do not charge the battery in temperatures above 113°F (45°C).

Replacing the Battery
To replace the lithium battery, refer to Replacement Parts and Accessories to order the (XT-BAT-K1) kit that includes the Replacing the GasAlertMaxXT Battery Operator's Manual.
Replacing a Sensor or Sensor Filter
a Warning
To avoid personal injury and/or property damage, use only sensors that are specifically designed for the detector. Refer to Replacement Parts and Accessories. · Each sensor has a high degree of resistance to common vapors and gases. To clear a sensor, move the detector to a clean environment and wait 10 to 30 minutes.
· Do not expose a sensor to vapors from inorganic solvents such as fumes from paint thinners, or organic solvents such as benzoic acids and acrylic acids).
To replace a sensor or sensor filter, refer to
· Table 11.,
· Figure 9.,
· Figure 10., and
· the following procedures.

54

Table 11. Replacing a Sensor or Sensor Filter

Item
1 2 3 4 5 6 7 8 9 10 11 12 13 14

Description
Front shell LEL sensor PCB PCB screws (2) Pump Rear shell Machine screws (6) Pump inlet Pump filter (particulate) Moisture filter CO sensor H2S sensor O2 sensor Sensor filter

GasAlertMaxXT II Maintenance
55

GasAlertMaxXT II Maintenance
Figure 9. Replacing a Sensor or Sensor Filter 56

1. Deactivate the detector.
2. Remove the pump inlet screw and the pump inlet. Refer to Figure 13.
3. Remove the six machine screws from the rear shell.
4. Because the pump hose is connected to the rear shell and front shell pump, carefully remove the rear shell by lifting upward and tilting to the left. The front and rear shells are laying flat side by side (Figure 10.).

GasAlertMaxXT II Maintenance
5. Remove the two PCB screws. 6. Lift the PCB upward and tilt to the left. Lay the PCB
(sensors facing up) onto the rear shell. 7. For CO, H2S, and LEL sensors, slide outward to remove.
To remove the O2 sensorgently insert a screwdriver to the back of the oxygen sensor to push out the sensor. Refer to Figure 11.

Figure 10. Front and Rear Shells Side by Side

Figure 11. Remove the O2 Sensor With a Scredriver Note
Detectors that are configured for 1, 2, or 3 gases may contain a dummy sensor in one of the four sensor locations. 8. Insert the new sensor(s). 9. If required, replace the sensor filter.
57

GasAlertMaxXT II User Manual
Note When inserting a new sensor filter, ensure the white side is facing the sensors and the black side is facing the front shell. 10. Replace the particulate and/or moisture filter if required.
Refer to Replacing the Pump Filters. 11. Re-assemble the detector and replace the PCB screws. 12. Replace the machine screws using 3-4 in-lbs. torque.
Tighten the screws using a crisscross pattern to ensure a proper seal. 13. Replace the pump inlet and the pump inlet screw. 14. Activate the detector and calibrate the sensor(s). Refer to Calibration.
58

Replacing the Pump Filters
Filters are inserted into the pump inlet to prevent dust particulates and moisture from entering the pump module.
Particulate Filters
The particulate filter will require frequent changes if the detector is being used in heavy particulate areas. If a pump alarm occurs and there is no blockage in the tubing, replace the particulate filter.
Moisture Filters
The moisture filter will not typically require frequent changes. If moisture is drawn through the tubing, replace both the moisture filter and the particulate filter immediately.
To change the particulate or the moisture filter, refer toTable 12., Figure 12., and the following procedures.
Table 12. Replacing the Pump Filters

Item
1 2 3 4 5 6

Description
Rear shell Moisture filter Pump quick connector Pump inlet Machine screw (1) Particulate filter

GasAlertMaxXT II Maintenance
1. Remove the one machine screw from the pump inlet and gently lift the bottom of the inlet outward at a 45° angle.

Figure 12. Replacing the Pump Filters

Figure 13. Removing the Pump Filters 2. Gently lift the pump inlet upwards to remove. Ensure the
hook on the pump inlet clears the housing. The particulate filter is located inside the pump inlet and the moisture filter is located on the rear shell.
59

GasAlertMaxXT II User Manual
3. Depending upon the circumstance, replace either just the particulate filter or both. Refer to Particulate Filters and Moisture Filters.
4. Reattach the pump inlet and replace the screw. Tighten the screw using 3-4 in-lbs. torque. Do not overtighten.
5. Activate the detector to begin the startup test and the pump block test. Depending upon the result, one of the following screens display.
Successful: If the block test is successful, the detector completes the startup test and enters normal operation. Unsuccessful: If the block test is unsuccessful, the detector deactivates. For causes and possible solutions, refer to Troubleshooting.
Replacing the Pump
To obtain a new pump (XT-RPUMP-K1) and the Pump Replacement Operator's Manual, refer to Replacement Parts and Accessories.
60

GasAlertMaxXT II User Manual

Troubleshooting
If a problem occurs, refer to the solutions provided in Table 15. If the problem persists, contact BW Technologies by Honeywell. Figure 14. Troubleshooting

Problem The detector does not activate. Detector automatically deactivates. The detector enters alarm immediately when activated.
The activation startup self-test fails.

Possible Cause Depleted battery
Damaged or defective detector Automatic deactivation due to depleted battery Lockout on Self-Test Error is enabled and a sensor(s) has failed the startup self-test Sensor needs to stabilize
Low battery alarm
Sensor(s) requires calibration
Hazardous environment
General fault Sensor error

Solution
Charge the battery. Refer to Charging the Battery.
Contact BW Technologies by Honeywell.
Charge the battery. Refer to Charging the Battery.
Refer to Lockout on Self-Test Error and Replacing a Sensor or Sensor Filter.
Used sensor: Wait 60 seconds New sensor: Wait 5 minutes
Charge the battery. Refer to Charging the Battery.
Calibrate the sensor(s). Refer to Calibration.
Leave the area immediately. Deactivate and reactivate the detector in a safe area that is free of hazardous gas.
Contact BW Technologies by Honeywell.
Replace the sensor. Refer to Replacing a Sensor or Sensor Filter.

61

GasAlertMaxXT II Troubleshooting

Problem Detector does not display normal ambient gas reading after startup tests.
Detector does not respond to pushbutton.
Detector does not accurately measure gas.
Detector does not enter alarm.

Table 7. Troubleshooting Possible Cause
Sensors not stabilized
Sensor(s) requires calibration Target gas is present
Battery is depleted
Detector is performing operations that do not require user input Sensor(s) requires calibration Detector is colder/hotter than gas temperature Sensor filter is blocked
Alarm setpoint(s) are set incorrectly
Alarm setpoint(s) set to zero
Detector is in calibration mode

Solution
Used sensor: Wait 60 seconds New sensor: Wait 5 minutes
Calibrate the sensor(s). Refer to Calibration.
Detector is operating properly. Use caution in suspect areas.
Charge the battery. Refer to Charging the Battery.
Pushbutton operation restores automatically when the operation ends.
Calibrate the sensor(s). Refer to Calibration.
Allow the detector to attain ambient temperature before use.
Replace the sensor filter. Refer to Replacing a Sensor or Sensor Filter.
Reset the alarm setpoints. Refer to Resetting Gas Alarm Setpoints.
Reset the alarm setpoints. Refer to Resetting Gas Alarm Setpoints.
Complete the calibration procedure.

62

GasAlertMaxXT II User Manual

Problem Detector intermittently enters alarm without reason.
Battery has been charging for 6 hours. Charging indicator on LCD shows the battery is still charging. Battery indicator does not display when charging. Pump is not operating.
Features and options not operating as expected.

Table 7. Troubleshooting Possible Cause
Ambient gas levels are near alarm setpoint or the sensor is exposed to a puff of the target gas Alarms are set incorrectly
Sensor(s) requires calibration Missing or faulty sensor(s)
Battery is trickle charging
Battery is depleted below normal levels
Diffusion cap is off or not attached correctly. There is a blockage in the tubing. Particulate and/or moisture filter requires replacement Changes in Fleet Manager II

Solution Detector is operating normally. Use caution in suspect areas. Check maximum gas exposure reading.
Reset the alarm setpoints. Refer to Resetting Gas Alarm Setpoints.
Calibrate the sensor(s). Refer to Calibration.
Replace the sensor(s). Refer to Resetting Gas Alarm Setpoints.
Battery is fully charged and is ready for operation.
Charge the battery for 8 hours. If the battery indicator does not light after charging, contact BW Technologies by Honeywell.
Attach diffusion cap. Ensure seal is tight.
Clear the blockage.
Replace the filter(s). Replacing the Pump Filters.
Verify that the settings in Fleet Manager II are correct.

63

GasAlertMaxXT II User Manual

Replacement Parts and Accessories
a Warning
To avoid personal injury or damage to the detector, use only the specified replacement parts.
To order parts or accessories listed in the following table, contact BW Technologies by Honeywell.
Table 13. Replacement Parts and Accessories

Model No.

Description

Qty

SR-WMC75C

Combustible (LEL) sensor

1

SR-X10-C1 Oxygen (O2) sensor

1

SR-M-MC

Carbon monoxide (CO) sensor

1

SR-H-MC

Hydrogen sulfide (H2S) sensor

1

REG-DF-1

Demand flow regulator

1

REG-0.5

0.5 l/min regulator

1

CG-Q58-4 CG-Q34-4 CG-T34 G0042-H25

Quad gas cylinder: CH4-2.5%, O2-18.0%, H2S25 ppm, CO-100 ppm, bal. N2 (58 l)

1

Quad gas cylinder: CH4-2.5%, O2-18.0%, H2S25 ppm, CO-100 ppm, bal. N2 (34 l)

1

Dual gas cylinder: 50% LEL (CH4-2.5%) O220.9%, bal. N2 (34 l)

1

Single gas cylinder: H2S 25 ppm, bal. N2 (58 l) 1

64

Model No.

Description

Qty

CG2-M-200103

Single gas cylinder: CO 200 ppm, bal N2 (103 l)

1

CG-BUMP1

Bump alarm gas aerosol (CH4-2.5%, O2-10%, H2S-40 ppm, CO-200 ppm)

1

CK-Q34-4

Quad calibration kit with regulator, quad gas cylinder (CG-Q34-4), hose, and carrying case

1

CK-Q58-4

Quad calibration kit with regulator, quad gas cylinder (CG-Q58-4), hose, and carrying case

1

XT-SS-1

Sensor filter for GasAlertMaxXT II, Kit of 2

2

GA-PFMAX Particulate filters (kit of 5)

5

GA-PFMAX50

Particulate filters (kit of 50)

50

GA-PFMAX100

Particulate filters (kit of 100)

100

XT-RF-H5

Hydrophobic (moisture) filters (kit of 5)

5

XT-RF-H50 Hydrophobic (moisture) filters (kit of 50)

50

XT-C01-MC5 GasAlertMaxXT multi-unit charger

1

GA-PA-1*

Charging adapter

1

DOCK2-0-1 C1M-00-N

GasAlertMaxXT docking module (for use w/ MicroDock II) and charging cable

1

GA-USB1-IR

IR connectivity kit (includes USB cable and Fleet Manager II CD-ROM)

1

Model No.

Description

Qty

XT-SCREW- Replacement screw kit (40 screws and screw-

K1

driver)

1

XT-BAT-K1 Battery replacement kit

1

XT-RPUMPK1

Pump replacement kit

1

GA-HXT

GasAlertMaxXT carrying holster

1

GA-BXT

GasAlertMaxXT rubber boot

1

XT-AG-1

Alligator clip (stainless steel)

1

*Add suffix (-UK) for United Kingdom mains plug, (-EU) for European mains plug, (-AU) for Australian mains plug.

GasAlertMaxXT II Replacement Parts and Accessories

65

GasAlertMaxXT II User Manual

Specifications
Instrument dimensions: 13.1 x 7.0 x 5.2 cm (5.1 x 2.8 x 2.0 in.)
Weight: 328 g (11.6 oz.)
Operating temperature: -20°C to +50°C (-4°F to +122°F) Storage temperature: -40°C to +60°C (-40°F to +140°F)
Operating humidity: 10% to 100% relative humidity (non-condensing)
Dust and moisture ingress: IP66/67
Alarm setpoints: May vary by region and are user-defined
Detection range: H2S: 0 ­ 200 ppm (1 ppm increments) CO: 0 ­ 1000 ppm (1 ppm increments) O2: 0 ­ 30.0% vol. (0.1% vol. increments) LEL (combustible): 0 ­ 100% LEL (1% LEL increments) or 0 ­ 5.0% v/v methane
Sensor type: H2S, CO, O2: Single plug-in electrochemical cell LEL (combustibles): Plug-in catalytic bead
O2 measuring principle: Capillary controlled concentration sensor
Alarm conditions: TWA alarm, STEL alarm, low alarm, high alarm, multi-gas alarm, over limit (OL) alarm, low battery alarm, confidence beep, automatic deactivation alarm, pump alarm
Audible alarm: 95 dB+ at 30 cm variable pulsed beeper with full battery charge

Visual alarm: Red light-emitting diodes (LEDs)
Display: Alphanumeric liquid crystal display (LCD)
Backlight: Activates upon startup and when the pushbutton is pressed; deactivates after 10 seconds. Activates during an alarm condition and remains lit until alarm ceases
Self-test: Initiated during activation, self-test runs continuously while detector is operational
Calibration: Automatic zero and automatic span
User field options: Startup message, lockout on self-test error, safe mode, confidence beep, latching alarm, force calibration, cal IR lock, force bump, location logging, force block test, set datalog interval, set confidence interval, language selection.
Sensor options: Sensor enable/disable, set span concentration values, set calibration interval, set bump interval, set alarm setpoints, set STEL interval, set TWA period, auto zero at startup enable/disable, 5% overspan, low alarm acknowledge, oxygen measurement, and combustible gas measurement
Maximum hose length for sampling: 75 ft (22 m)
Maximum hose length for calibration: 3 ft (0.9 m)
Battery operating time: One rechargeable lithium polymer battery at 20°C provides 13 hours operating runtime
Year of manufacture: The detector's year of manufacture is determined from the serial number. The first and second number after the first two letters determines the year of manufacture.
Example: MA110-001000 = 2010 year of manufacture

66

Approved battery for GasAlertMaxXT II product: Lithium-ion polymer (MA-BAT01) as per standards EN50020, UL913, CSA C22.2 No. 157

Rechargeable battery (MX-BAT01)

Temperature Code

Lithium Polymer

-20°C  Ta  +50°C T4

Battery charger: GasAlertMaxXT II Charging Adapter

First-time charge: 6 hours

Normal charge: 6 hours

Warranty: 2 years including sensors

Approvals:

Approved by CSA to both U.S. and Canadian Standards

CAN/CSA C22.2 No. 157 and C22.2 152

ANS/UL ­ 913 and ANSI/ISA ­ S12.13 Part 1

CSA

Class I, Division 1, Group A, B, C, and D

ATEX

CE 0539 g II 1 G Ex da ia IIC T4 Ga

KEMA 08 ATEX 0001

EN 60079-0, EN 60079-1, EN 60079-11

IECEx

Ex da ia IIC T4 Ga CSA 07.0012

IEC 60079-0, IEC 60079-1, IEC 60079-11

INMETRO Ex ia IIC T4 Ga DNV 12.0135

KTL

12-KB4BO-0054a

IP

IP66/IP67

a. http://www.honeywellanalytics.com/~/media/honeywell-analytics/products/gasalertmax-xtii/documents/certifications/koreanexcertificate_bw_gamaxxtii_12kb4bo0054.pdf?la=en

GasAlertMaxXT II Specifications
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and ICES-003 Canadian EMI requirements. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of more of the following measures:
· Reorient or relocate the receiving antenna.
· Increase the separation between the equipment and receiver.
· Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
· Consult the dealer or an experienced radio/TV technician for help.

67

GasAlertMaxXT II User Manual General Datalogger Specifications
Storage: 375 hours at 15-second intervals (75% redundancy) Memory type: Wraparound memory ensures most recent data is always saved Sample rate: One reading every 1-120 seconds Data recorded: All sensor readings, all alarm conditions, calibrations, event flags, battery status, sensor status, pump status, confidence beep activation, and detector status along with the time and date for each reading and unit serial number Operation: Requires no user intervention (automatic) Compatible with: Desktop PC computer or laptop Operating system: Windows XP and Windows Vista Download via: IR device (IR Link adapter or MicroDock II Base Station) Software required: Fleet Manager II and Microsoft Excel
68

129541_EN_B [English] © BW Technologies 2016. All rights reserved

References

    Acrobat Distiller 15.0 (Windows)


    Is the category for this document correct?

    1. Engineering & Technology
    2. Electrical Engineering


    Thank you for your participation!

    No more boring flashcards learning!

    Learn languages, math, history, economics, chemistry and more with free Studylib Extension!

    • Distribute all flashcards reviewing into small sessions
    • Get inspired with a daily photo
    • Import sets from Anki, Quizlet, etc
    • Add Active Recall to your learning and get higher grades!

    Add to Chrome
    It’s free

    8 (800) 350-41-98, +7 (495) 123-35-04
    Доставка по России и в страны ЕАЭС

    GasAlertMax XT II — оборудование, которое способно измерять до 4-ёх газов (горючие, CO, O2, H2S) в воздушном пространстве. Широко применяется в нефтегазовой промышленности, на топливно-энергетических комплексах, в сфере ЖКХ и прочих отраслях.

    Прибор прост и удобен в эксплуатации, обладает небольшими размерами и малым весом. Корпус выполнен из прочного, взрывозащищенного материала. Аппарат водонепроницаем, выдерживает падение с высоты. Наличие функции самодиагностики позволяет осуществлять проверку работоспособности всех механизмов, обеспечивая получение высокоточных результатов измерения.

    Одной из особенностей газоанализатора GasAlertMax XT II является встроенный насос для отбора проб из колодцев или других помещений дистанционно. Полученная информация отображается на ярком ЖК мониторе с подсветкой. Управление осуществляется с помощью одной кнопки, расположенной на лицевой панели.

    Внешний вид инструмента представлен на рисунке ниже.

    Устройство имеет совместимость со станцией автоматического тестирования и калибровки BW MicroDock II. В аппаратуре предусмотрена светозвуковая сигнализация, срабатывающая при обнаружении недопустимых концентраций измеряемых веществ. Анализатор наделен возможностью регистрации показаний и событий.

    Краткие характеристики GasAlertMax XT II:

    Габариты – 131x70x52 мм. Масса – 328 грамм. Рабочая температура – от -40 до +50 градусов Цельсия. Класс защиты оболочки – IP 66/67. Питательным элементом служит подзаряжаемый литиево-полимерный аккумулятор, рассчитанный на 12 часов активности.

    Документация:

    Руководство по эксплуатации GasAlertMax XT II
    Презентация газоанализаторов GasAlert

    Понравилась статья? Поделить с друзьями:
  • Daleron cold 3 инструкция по применению на русском
  • Fantastique cleo 3d ручка инструкция по применению
  • Витафон цена в москве в аптеке инструкция отзывы
  • Пентоксифиллин 200 инструкция по применению цена отзывы аналоги цена
  • Как работает приложение тинькофф инвестиции инструкция по применению