Hanna hi 9124 инструкция на русском

Hanna HI 9124 Instruction Manual

  • Contents

  • Table of Contents

  • Troubleshooting

  • Bookmarks

Quick Links

Instruction Manual

HI 9124 HI 9125

Portable Waterproof

pH Meters

w w w. h a n n a i n s t . c o m

1

loading

Related Manuals for Hanna HI 9124

Summary of Contents for Hanna HI 9124

  • Page 1
    Instruction Manual HI 9124 HI 9125 Portable Waterproof pH Meters w w w. h a n n a i n s t . c o m…
  • Page 2: Table Of Contents

    W A R R A N T Y WARRANTY HI 9124 & HI 9125 are guaranteed for two years against defects in workmanship and materials when used for their intended purpose and maintained according to instructions. Electrodes and probes are guaranteed for six months.

  • Page 3: Preliminary Examination

    Remove the instrument from the packing material and examine it to make sure that no damage has occurred during shipping. If there is any damage, notify your dealer or the nearest Hanna Customer Service Center. Each meter is supplied with: •…

  • Page 4: Lcd Message Guide

    LCD MESSAGE GUIDE LCD MESSAGE GUIDE LCD MESSAGE GUIDE LCD MESSAGE GUIDE LCD MESSAGE GUIDE TAGS & SYMBOLS • Mode tags lights up for indicating the corresponding active mode, and blinks for warning the user. MEASURE on: measurement mode. SETUP on: SETUP menu mode has been entered. CALIBRATION on: calibration mode has been entered.

  • Page 5: Functional Description

    F U N C T I O N A L D E S C R I P T I O N F U N C T I O N A L D E S C R I P T I O N F U N C T I O N A L D E S C R I P T I O N F U N C T I O N A L D E S C R I P T I O N F U N C T I O N A L D E S C R I P T I O N…

  • Page 6: Specifications

    SPECIFICATIONS SPECIFICATIONS SPECIFICATIONS SPECIFICATIONS SPECIFICATIONS ± ± ) y l C ° ° ) y l C ° ° ± ± ± ) y l C º F º ± C ° ± ° r r e ) r o ±…

  • Page 7: Operational Guide

    OPERATIONAL GUIDE OPERATIONAL GUIDE OPERATIONAL GUIDE OPERATIONAL GUIDE OPERATIONAL GUIDE INITIAL PREPARATION The instrument is supplied with batteries. In order to place the batteries inside the instrument follow the instructions from page 16. To prepare the instrument for use, connect the pH electrode and the temperature probe to the BNC and temperature sockets on the top of the instrument.

  • Page 8
    The LCD will show the pH measurement and the temperature of the sample. If several measurements are taken successively in different samples, rinse the electrode thoroughly with deionized or tap water and a small amount of the sample to be measured. The pH value of the sample is directly affected by temperature.
  • Page 9
    ORP MEASUREMENTS (HI 9125 only) To perform ORP measurements, connect an optional ORP electrode (see “Accessories” section) to the meter and turn it ON. If necessary, enter the mV mode by pressing RANGE until the display changes to mV. Submerse the ORP electrode 3 cm (1¼”) into the sample to be tested and wait a few minutes for the reading to stabilize.
  • Page 10: Ph Calibration

    p p p p p H CALIBRATION H CALIBRATION H CALIBRATION H CALIBRATION H CALIBRATION It is recommended to calibrate the instrument frequently, especially if high accuracy is required. The pH range should be recalibrated: • Whenever the pH electrode or temperature probe is replaced. •…

  • Page 11
    • The LCD will flash the “WAIT NOT READY” message. • Once the reading is stable, if it is not close to the selected buffer, “WRONG “ and “WRONG “ will blink alternatively; if it is close to the selected buffer the display will change to “READY” and blinking “Press: CFM to confirm calibration point”.
  • Page 12
    • If the reading is not close to the selected buffer, “WRONG ” and “WRONG ” will blink alternatively; • If the reading is close to the selected buffer and the reading is stable, the “READY” symbol is displayed and the “CFM” symbol starts blinking on the LCD, asking for confirmation.
  • Page 13: Ph Buffer Temperature Dependence

    p p p p p H BUFFER TEMPERATURE H BUFFER TEMPERATURE H BUFFER TEMPERATURE H BUFFER TEMPERATURE H BUFFER TEMPERATURE D E P E N D E N C E D E P E N D E N C E D E P E N D E N C E D E P E N D E N C E D E P E N D E N C E…

  • Page 14: Setup Menu

    S E T U P M E N U S E T U P M E N U S E T U P M E N U S E T U P M E N U S E T U P M E N U Instrument allows the user to configure several parameters through the Setup Menu.

  • Page 15: Mv Calibration (Hi 9125 Only)

    TEMPERATURE CALIBRATION TEMPERATURE CALIBRATION TEMPERATURE CALIBRATION HI 9124 & HI 9125 have been precalibrated for temperature at the factory. For optimum accuracy, it is recommended to recalibrate the meter for temperature at least once a year. Contact your Dealer or the nearest…

  • Page 16: Batteries Replacement

    BATTERIES REPLACEMENT BATTERIES REPLACEMENT BATTERIES REPLACEMENT BATTERIES REPLACEMENT BATTERIES REPLACEMENT The instrument is supplied with batteries. First time you start working with the instrument, insert the supplied batteries in the battery compartment observing the correct polarity (see page 17). At start-up the battery percentage is displayed. If the batteries become weak, the display will flash the battery symbol to advise the user that approximately 1 hour of working time remains.

  • Page 17
    To replace the batteries, follow the next steps: • Turn the instrument OFF. • Open the battery compartment cap (located on the top of the instrument). • Remove old batteries. • Insert three new 1.5V AAA batteries in the battery compartment, observing the polarity on the rear of the instrument.
  • Page 18: Temperature Correlation For Ph Sensitive Glass

    The pH at which the interference starts to be significant depends upon the composition of the glass. This interference is called alkaline error and causes the pH to be underestimated. Hanna’s glass formulations have the indicated characteristics. Sodium Ion Correction for Glass at 20-25 °C…

  • Page 19: Electrode Conditioning & Maintenance

    E E E E E LECTRODE CONDITIONING & MAINTENANCE LECTRODE CONDITIONING & MAINTENANCE LECTRODE CONDITIONING & MAINTENANCE LECTRODE CONDITIONING & MAINTENANCE LECTRODE CONDITIONING & MAINTENANCE Not present in gel electrodes. PREPARATION PROCEDURE Remove the electrode protective cap. DO NOT BE ALARMED IF ANY SALT DEPOSITS ARE PRESENT. This is normal with electrodes and they will disappear when rinsed with water.

  • Page 20
    Soak in Hanna HI 7074 Inorganic CleaningSolution for 15 min. • Oil/grease Rinse with Hanna HI 7077 Oil & Fat Cleaning Solution for 1 min. IMPORTANT: After performing any of the cleaning procedures, rinse the electrode thoroughly with distilled water and soak it in HI 70300…
  • Page 21: Troubleshooting Guide

    T R O U B L E S H O O T I N G G U I D E T R O U B L E S H O O T I N G G U I D E T R O U B L E S H O O T I N G G U I D E T R O U B L E S H O O T I N G G U I D E T R O U B L E S H O O T I N G G U I D E…

  • Page 22: Accessories

    A C C E S S O R I E S A C C E S S O R I E S A C C E S S O R I E S A C C E S S O R I E S A C C E S S O R I E S pH CALIBRATION SOLUTIONS pH 4.01 Buffer Solution, 20 mL sachet, 25 pcs…

  • Page 23
    pH ELECTRODES All electrodes part numbers ending in B are supplied with a BNC connector and 1 m (3.3′) cable, as shown below: HI 1043B Glass-body, double junction, refillable, combination pH electrode. Use: strong acid/alkali. 9.5mm DIA 12 mm 0.37″ 0.5″…
  • Page 24
    HI 1330B Glass-body, semimicro, single junction, refillable, combination pH electrode. Use: laboratory, vials. 5mm DIA 0.2″ 0.2″ HI 1330 120 mm 4.7″ «S» VERSION HI 1331B Glass-body, semimicro, single junction, refillable, combination pH electrode. Use: flasks. 8 mm 7.5mm DIA 0.3″…
  • Page 25
    FC 100B Plastic-body (PVDF), double junction, refillable, combination pH electrode. Use: general purpose for food industry. 12 mm 0.5″ FC 100 120 mm 4.7″ FC 200B Plastic-body (PVDF), open junction, conic, Viscolene, non-refillable, combination pH electrode. Use: meat & cheese. 6 mm 0.25″…
  • Page 26
    12 mm 0.5″ HI 4430 120 mm 4.7″ «S» VERSION Consult the Hanna General Catalog for a complete and wide selection of electrodes. OTHER ACCESSORIES HI 721317 Rugged carrying case HI 740157 Plastic electrode refilling pipet (20 pcs) HI 76405…
  • Page 27
    24 VAC or 60 VDC. To avoid damage or burns, do not perform any measurement in microwave ovens. Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice.
  • Page 28
    Hanna Instruments Inc. Highland Industrial Park 584 Park East Drive Woonsocket, RI 02895 USA Technical Support for Customers Tel. (800) 426 6287 Fax (401) 765 7575 E-mail tech@hannainst.com www.hannainst.com Local Sales and Customer Service Office Printed in EUROPE (ROMANIA) MAN9125Y 09/10…

This manual is also suitable for:

Hi 9125

Скачать файл PDF «Hanna Instruments HI 9124 Инструкция по эксплуатации» (2.64 Mb)

Популярность:

2364 просмотры

Подсчет страниц:

14 страницы

Тип файла:

PDF

Размер файла:

2.64 Mb

HI9124 это надежный, влагозащищенный, портативный рН- и мВ-метр. В приборе реализовано большое количество современных функций, включая автоматическую калибровку, автоматическое отключение, систему предотвращения ошибок батарейки, выводимые на экран инструкции и автоматическую компенсацию температуры. Комплект поставки HI9124 включает прибор, рН электрод в пластиковом корпусе из полиэфиримида c двойной диафрагмой, а также датчик температуры; всё это упаковано в прочный пластиковый чемоданчик для транспортировки.

Прибор внесен в государственный реестр средств измерений

Автоматическая калибровка

Вывод инструкции на экран

Влагозащищенный

Описание

The HI9124 собой надежный, портативный измеритель рН и мВ, предназначенный для обеспечения точных и аккуратных измерений в суровых экологических и промышленных условиях. В приборе реализовано большое количество современных функций, включая автоматическую калибровку по 1 или 2 точкам, автоматическую компенсацию температуры, жидкокристаллический дисплей с подсветкой, выводимые на экран инструкции, систему предотвращения ошибок батарейки.

Для подключения рН электродов в приборе HI9124 используется универсальный BNC разъём. Универсальный разъём BNC позволяет пользователю выбирать из широкого спектра электродов в зависимости от их конкретного применения. Отдельный разъем RCA используется для подключения датчика температуры на основе термистора. Для обеспечения точной температурной компенсации, датчик температуры обеспечивает высокую ± 0,4 °C точность измерения.

Особенности

Калибровка по одной или двум точкам -автоматическую калибровку можно выполнять по 1 или 2 точкам с использованием 5 стандартных буферов (pH 4,01; 6,86; 7,01; 9,18 и 10,01).

Инструкции на экране — понятные и простые в использовании инструкции на экране прибора проведут вас через все шаги проведения калибровки и измерений.

Долговечный pH электрод в пластиковом корпусе — HI9124 поставляется в комплекте с заполненным гелем рН электродом HI1230B в пластиковом корпусе из полиэфиримида и двойной диафрагмой. Корпус из полиэфиримида обладает превосходной химической стойкостью ко многим агрессивным химикатам. Конструкция двойной диафрагмы помогает свести к минимуму загрязнения внутренней ячейки сравнения, которые могут вызывать осаждение электролита Ag/AgCl и засорение диафрагмы. Электроды HI1230B заполнены гелем и не требуют пополнения раствором электролита для поддержания работоспособности.

Температурная компенсацияприбор HI9124 предоставляет пользователям выбор между автоматической и ручной температурной компенсацией измерения рН в широком диапазоне от -20,0 до 120,0 ° C.

Вызов сохранённого значения — прибор HI9124 оснащён кнопкой «МЕМ» для сохранения результата измерения. Сохранённый результат можно вызвать в любое время, нажав на кнопку вызова памяти «MR».

Автоматическое выключение — прибор HI9124 имеет регулируемую функцию автоматического выключения. С целью предотвращения случайной разрядки батареек, прибор можно запрограммировать на автоматическое выключение через 20 минут. Эту функцию можно отключить; в этом случае, пользователь должен выключать прибор с помощью кнопки питания.

Система предотвращения ошибки батарейки (BEPS) — Система обнаруживает момент, в который заряд батарей питания становится слишком низким для получения достоверных показаний.

Таблица характеристик

Диапазон pH от -2.00 дo 16.00 pH
Разрешение pH 0,01 pH
Точность pH ±0,01 pH
Калибровка pH автоматическая, одно- или двухточечная по пяти буферным растворам из памяти (pH 4,01; 6,86; 7,01; 9,18; 10,01)
Температурный диапазон от -20,0 дo 120,0 ºC, от -4,0 дo 248,0 °F
Разрешающая способность по температуре 0,1 °C; 0,1 °F
Точность температуры ±0,4°C; ±0,8°F
Температурная Компенсация ручная или автоматическая от -20,0 дo 120,0°C (от -4,0 дo 248,0°F)
Калибровка наклона от 80 дo 108% / ±1 pH
pH электрод рН электрод HI1230B в пластиковом корпусе из полиэфиримида с разъёмом BNC и кабелем 1 м (3,3 ‘) (входит в комплект)
Термодатчик Датчик температуры HI7662 из нержавеющей стали с 1 м (3,3 ‘) кабелем (входит в комплект)
Входное сопротивление 10¹² Ом
Тип батареи/срок службы 1,5V (3) AAA / приблизительно 200 часов непрерывной работы
Автоотключение После 20 мин бездействия (функция может отключаться)
Окружающая среда от 0 до 50 ° C (от 32 до 122 ° F); относительная влажность макс. 100%
Размеры 185 x 72 x 36 мм (7,3 x 2,8 x 1,4”)
Вес 400 г
Информация для заказа HI9124 поставляется с рН электродом HI1230B, термодатчиком HI7662, пакетиком буферного раствора pH 4,01 HI70004 t, пакетиком буферного раствора pH 7,01 HI70007, 100 мл пластиковым стаканчиком, 1,5В AAA батарейками (3), инструкцией, твёрдым футляром для транспортировки.

Портативные рН-метры

Купить pH-метр HANNA HI 9124 (портативный) производителя HANNA Instruments по низкой цене в нашем интернет-магазине. Если вам нужно узнать более подробную информацию о характеристиках pH-метр HANNA HI 9124 (портативный), получить техническую документацию, либо узнать отзывы – пожалуйста не стесняйтесь, звоните нашим менеджерам, они с удовольствием проконсультируют и расскажут об отзывах на pH-метр HANNA HI 9124 (портативный).
Посмотреть другие модели Портативные рН-метры
pH-метр HANNA HI 9124 (портативный) сертифицирован для продажи в России.

1

Instruction Manual

HI 9124 HI 9125

Portable Waterproof

pH Meters

www.hannainst.com

28

SALES AND TECHNICAL SERVICE CONTACTS

Australia:

Tel. (03) 9769.0666 • Fax (03) 9769.0699

China:

Tel. (10) 88570068 • Fax (10) 88570060

Egypt:

Tel. & Fax (02) 2758.683

Germany:

Tel. (07851) 9129-0 • Fax (07851) 9129-99

Greece:

Tel. (210) 823.5192 • Fax (210) 884.0210

Indonesia:

Tel. (21) 4584.2941 • Fax (21) 4584.2942

Japan:

Tel. (03) 3258.9565 • Fax (03) 3258.9567

Korea:

Tel. (02) 2278.5147 • Fax (02) 2264.1729

Malaysia:

Tel. (603) 5638.9940 • Fax (603) 5638.9829

Singapore:

Tel. 6296.7118 • Fax 6291.6906

South Africa:

Tel. (011) 615.6076 • Fax (011) 615.8582

Taiwan:

Tel. 886.2.2739.3014 • Fax 886.2.2739.2983

Thailand:

Tel. (662) 619.0708.11 • Fax (662) 619.0061

United Kingdom:

Tel. (01525) 850.855 • Fax (01525) 853.668

USA:

Tel. (401) 765.7500 • Fax (401) 765.7575

For e-mail contacts and a complete list of Sales and

Technical offices, please see 

www.hannainst.com

.

MAN9125R2

 02/08

Понравилась статья? Поделить с друзьями:
  • Киа спектра 2007 инструкция по эксплуатации
  • Инструкция по оперативным переключениям в электроустановках 2022
  • Dse 702 контроллер инструкция на русском
  • Руководствуясь требованиями руководства
  • Покраска авто своими руками в раптор пошаговая инструкция