Warning
When using this instrument, please do not look directly at the optical interface or the end of the optical �iber with
your eyes, avoid eye damage!Any change or modi�ication not explicitly permitted in this manual will deprive you of
the right to operate the equipment.To reduce the risk of �ire or electric shock, do not expose the equipment to
thunderstorm or humid environment.In order to prevent electric shock, do not open the shell, it must be repaired by
the quali�ied personnel designated by the manufacturer.
Attention
Battery: The battery in the machine is a special lithium-ion polymer battery. The charging voltage is 5V, and the
charging temperature ranges from 0℃~ 50℃. When the ambient temperature is too high, the charging will
automatically terminate. When the instrument is not used for a long time, the battery should be removed. The
temperature range of the battery during long-term storage is -20℃~ 45℃.
Please use the special AC adapter attached to this instrument and use the external power supply strictly according to
the speci�ications, otherwise the equipment may be damaged.
LCD screen: The display of this series of instruments is 3.5 inch color LCD. In order to maintain good viewing effect,
please keep the LCD screen clean and clean. When cleaning, the LCD screen can be cleaned by wiping with soft
fabric.
VFL
OTDR
4
3
1
Optical Fiber Tester
3
1
2
F1
F2
F3
OK
Zoom key
Zoom function key, combined with
direction keys to operate.
ON/OFF key
Short press to turn on, long press to
turn off; after turning on, short press
to turn on or off the flashlight.
OK key
Enter the next level of interface, Enter function
Turn on and enter the main menu. There are
eight functional modules. Select the module by
pressing the direction keys, and then press the
«OK» key to enter the corresponding functional
interface.
Time
2019-04-26
F1: Enter the parameter setting interface
F2: Switching A/B cursor
F3: Enter the save interface
F4: File or Folder operation
OTDR setting interface
Enter the parameter setting interface. Multi-digit
settings, through the left and right key positioning
cursor, up and down selection.
▲▼: Choosing settings items.
Press OK button to con�irm or edit corresponding
measurement parameters.
9
8
9
8
9
8
F1: Test
F2: OK
F3: Recovery
F4: Cancel
Link quality and information can be viewed
from the top after the test is completed,
Link information includes length, total loss and
number of events.
Detailed event information can be viewed from
the event list.
There are Four types of events:
Reflective event
Non-reflective event
Fiber splitter
Fiber end
Press
to enter zoom mode
X-axis direction zoom in
X-axis direction zoom out
Y-axis direction zoom in
Y-axis direction zoom out
OK
Press
1:1 display
Optical Fiber Tester
F1
F2
F3
F4
OK
OPM
OTDR/LS Port
1
OPM Port
2
2
VFL Port
3
1
Flashlight
4
Right side
2
RJ45
RJ45 Interface
1
2
1
Reset button
2
F4
Main view
3
Dust Cover
1
3.5 inch Color LCD
2
Function Keys
3
1
Functional Keys
Functional keys
Correspond to the operation menu below the screen.
F1
F2
Main Interface
Flashlight
TF
USB
Battery
14:00
Link Information
Waveform
A/B cursor
A/B Information
Test Conditions
Event List
OTDR Setting Interface
7
7
7
OTDR-Zoom mode
Optical Fiber Tester
Brief
Top view
F3
F4
OK
2019-04-26
OPM
dB/dBm/mW
Laser Source
RJ45 Sequence
OTDR
2019-04-26
PASS
Len
A 0.000Km
A-B
Dis
Test
Wave
NO
Type
2-1
2-2
Set
F1
2019-04-26
Wave
Mode
Range
Pulse
Avg. Time
Event Loss Thre.
Return Loss Thre.
End Loss Thre.
Ior
Auto Analyze
Test
F1
Test Results
2019-04-26
PASS
Len
A 0.000Km
A-B
Dis
Test
Wave
NO
Type
2-1
2-2
Set
F1
2019-04-26
PASS
Len
Zoom Mode
A 0.000Km
A-B
Dis
Test
Wave
NO
Type
2-1
2-2
Set
F1
User’s Manual
Left side
Micro USB
1
Charging LED Indicator
2
TF Card Port
3
Bottom view
RJ45 Remote tester
1
Measure key
Press to start or stop the test under
the OTDR interface
Return to the previous menu
Directional keys
Up and down choice, right and left choice
14:00
OTDR
Event MAP
VFL
650nm
OPM
VFL
Length & Tracker
1 2 3 4 5 6 7 8
System
14:00
4.000km
Loss
0.80dB
Event
2
1
2
B 3.057Km
Loss
AV.-L
2.000km
0.40dB
0.18dB/km
1550nm
Range
8km
Pulse
50ns
Dis
Event-L AV.-L
Return-L Link-L
(Km)
(dB)
(dB/Km)
(dB)
(dB)
1.000
0.80
0.18
35.00
0.20
4.000
0.00
0.18
30.00
0.80
Cursor
Save
File
F2
F3
F4
14:00
1550nm
Real
20Km
50ns
5s
0.1dB
40dB
10dB
1.46825
OK
Recover
Cancel
F2
F3
F4
14:00
4.000km
Loss
0.80dB
Event
2
1
2
B 3.057Km
2.000km
Loss
0.40dB
AV.-L
0.18dB/km
1550nm
Range
8km
Pulse
50ns
Dis
Event-L AV.-L
Return-L Link-L
(Km)
(dB)
(dB/Km)
(dB)
(dB)
1.000
0.80
0.18
35.00
0.20
4.000
0.00
0.18
30.00
0.80
Cursor
Save
File
F2
F3
F4
14:00
4.000km
Loss
0.80dB
Event
2
1
2
B 3.057Km
Loss
AV.-L
2.000km
0.40dB
0.18dB/km
1550nm
Range
8km
Pulse
50ns
Dis
Event-L AV.-L
Return-L Link-L
(Km)
(dB)
(dB/Km)
(dB)
(dB)
1.000
0.80
0.18
35.00
0.20
4.000
0.00
0.18
30.00
0.80
Cursor
Save
File
F2
F3
F4
2
3
Exit key
4
5
6
7
8
- Вся активность
Join the conversation
You can post now and register later.
If you have an account, sign in now to post with your account.
mini pro OTDR
Model: FF-980REV
Wavelength: 1310 and 1550nm
Dynamic Range: 24/22dB
Testing Range: 3m to 64km
9 Functions in 1 Device
1) OTDR
2) EVENT MAP
3) Optical Light Source
4) Optical Power Meter
5) Visual Fault Locator
6) RJ45 Ethernet Cable Sequence
7) Ethernet Cable Distance
Ethernet Cable Tracker
9) LED Light
Frequently Asked Questions on OTDR
Model# FF-980REV
Q1: Does the OTDR (FF-980REV) support both 1310nm and 1550nm wavelengthes to test fibers?
A1: Yes, the OTDR support both 1310nm and 1550nm wavelengths.
Q2: Does the OTDR (FF-980REV) support real time and average time testing mode like other world famous OTDR?
A2: Yes, the OTDR support both read time and average time testing mode. And of course, Auto Mode is also supported.
Q3: Does the test result can be displayed quickly on screen?
A3: Yes, very quickly. If you selected «Auto» testing mode, it takes 5 seconds to display OTDR curves and event list on screen.
Q4: What connectors do come with the OTDR?
A4: The OTDR comes with FC, SC in default. ST and LC connector are sold separately.
Q5: My fiber cable is with a APC connector, but I have bought an OTDR with UPC connector(port). How can I make the test?
A5: According to industrial standard, APC connector can not work together with UPC connectors. So (1) please find a short fiber patch cord, one end is with APC and the other end is with UPC. (2) Use the UPC to APC adapter. See the picture. (3) buy an OTDR with APC connector(port). Please let our sales know you are going to buy an OTDR with APC connector before you place your order.
Q6: Do I need to add money for extra functions (VFL, OPM, OLS, Ethernet Cable Testing) ?
A6: No. The OTDR comes with all of these functions.
Q7: Do the OTDR comes with Event Map?
A7: Yes.
Q8: The OTDR can work on short cables, e.g. 3 meters ?
A8: Yes. It is good at short cable testing from 3 meters to 64km. Check the video please. https://youtu.be/Oxy0huN3uBs
Q9: Do you have a video demo?
A9: Yes, watch the video please.
Q10: How to re-calibrate the OTDR, and any fees charged for re-calibration?
A10: The OTDR has been already built-in self-calibration system. If testing calibration needed to be deployed, OTDRs should be sent back China. Customer pays for shipping fees to China while we pay shipping fees to customer. But within warranty time (3 years), customer does not need to pay any fees. And no other fees will be charged for calibration or repair work.
Q11: What is your warranty time and repair policy?
A11: If software problems, we can send you a firmware for system upgrade by email. If a hardware problem, our engineers can cooperate with you to find which part is broken in OTDR via email or skype video. And we send you the hardware parts, and teach you how to repair. But if it is not easy to repair from your side, you must return back for repair.
Customer pays for shipping fees to China while we pay shipping fees to customer. But within warranty time (3 years), customer does not need to pay any fees. And no other fees will be charged for calibration or repair work.
Q12: Does the OTDR FF-980REV support active (live) fiber testing?
A12: No, Normal model does not support active fiber testing, but we accept OEM for bulk order.
Q13: Is it easy to be damaged when the OTDR drops from high position?
A13: The screen of the OTDR is made from enhanced PVC plastic, instead of traditional glass. So it is not easy to be damaged. Please visit the link for a video demo drops from 2.5 meters height postion. https://youtu.be/ujacRXyJevw
Q14: does the output laser from OTDR destroy CPEs (eg, ONU/ONT)?
A14: No. From OTDR theory, it can not shine out enough strong laser to destroy any other equipment. The output power of OTDR is very low to keep itself sensitive to get and analysis back-scattering light along fiber cable. We take a video to show you how the low output power value from the OTDR. To get highest power value of OTDR, we set the pulse width in OTDR to 20000us, and from power meter, you can see the highest power value is around -28dBm. While take Huawei’s ONU HG8310M for example, the allowed maximum input power is -8dBm. -28dBm output power of OTDR is much lower than -8dBm. So, even though OTDR launches power into ONT directly, it won’t damage CPE. Visit the video please. https://youtu.be/65-_dJ3TDhc
Q15: Does the OTDR can generate .sor file and print out testing report?
A15: Yes. Like any other normal OTDR. The FF-980REV can generate .sor files, and users can print testing report via PC software.
Q16: Could you provide technical support or training service on the OTDR?
A16: Yes, I can help if you have any questions on the OTDR.
Q17: Could you make OEM service? I want to make my logo on your OTDR?
A17: Yes, of course. Please contact our sales team. sales@FirstFiber.cn
Q18: Why I can not see A-B distance and attenuation value on PC software?
A18: Please contact us our sales to get a new PC software.
Q19: User can switch languages on OTDR?
A19: The OTDR comes with English in default. If you need it with other languages, please contact our sales to check if your language available or not.
Q20: I am a distributor in our local market. I am interested in marketing the OTDR here. Could you do OEM for me? I mean making booting screen with my logo, print logo on front panel of the device, and lable my model number.
A20: Yes, of course. We support OEM, and can customize device for customers. Please contact us for more details sales@firstfiber.cn
Q21: How is the OTDR workable for aerial cable works
A21:
1. Small handy, Palm size, Light
2. Screen can be seen clearly even under sunshine
3. Quick pass or Fail on the left-top side of screen. When it indicated PASS, users do not need to care about link information in more details.
4. Easy one-button Testing. Its “Auto-Test” function is powerful, users do not need to set complicated parameters
5 Easy software Event Map
6. With hooks on both sides for attaching safety loop string and place it around user’s neck. If the OTDR slipped from user’s hand. It will be safely catched by the string.
7. It also comes with soft case that can be hung from workbelt.
Q22: Do you provide spare battery for the OTDR?
A22: The OTDR was designed on the concept of no extra spare battery needed. The working time of battery can reach for one full day work (12 hours). The battery cable was plugged into PCB directly, replacing battery in field does not suggested. The OTDR can be charged power via any USB devices like power bank, car, laptop, etc.
Q23: Please confirm OTDR ability to provide in-service communication check before testing with message warning and auto termination functions to effectively protect test instruments and communications as well as CPEs
A23: Yes, confirmed. It will display a warning message on screen, but to protect laser diode, please make sure the power value to OTDR port does not over -5dBm. Strongly suggest that all users test power value by “OPM” function on the device before they use OTDR function.
Q24: Could you please state the type, capacity and weight of OTDR battery?
A24: Lithium Ion Battery(with battery certificate for security shipment), 3.7V-4000mAH/14.8WH
Q25: Why FF-980REV OTDR can not be turned on?
A25: Some customers complain that their FF-980REV OTDR can not be turned on any more. The problem was often caused by not right operating on the OTDR when they test RJ45 cables. Please do not test RJ45 cables if signals exist in RJ45 cable. To proof, please do as following steps,
1) Disassemble the device.
2) Press and hold power on button, and meantime, checking the voltage of TP11 point. It should be around 5.2V. Watch the video.
3) Remove N10 and N15
Now, OTDR should be ok to turned on. But RJ45 sequence and RJ45 length functions do not work. Other functions works in right situation. Please contact us to have new N10 and N15.
Q25: The VFL in OTDR FF-980REV is very week. How to solve it?
A25: The problem was caused by broken VFL laser. VFL laser has to be changed.
Q26: FF-980REV OTDR curve is ok, but there is nothing in event list area
A26: This issue should be caused by incorrect threshold value. Please reset all parameters to factory setting.
Q27: Why Launch Cable Is needed for OTDR Testing
A27: Launch cable, sometimes is called launch box, fiber reel, or bare fibers. It is acturally a longer fiber jumper, but with much lower insertion loss of both cable and its connectors.
When users measure fibers with OTDR, launch box is often used to
1. Protect bulkhead on OTDR from contaminated
2. Change connector type from OTDR to fiber under test (from FC/UPC on OTDR to SC/APC on fiber under test)
3. Checking first connector condition of fibers under test
One more thing, receive cable is often used at end of fiber under test.
Warranty Service:
FirstFiber warrants to the purchaser that our products shall be free from defects in material and workmanship under normal use (consumables, normal tear and wear excluded) for a period of one year from the date of shipment. Any part which is determined by FirstFiber to be defective in material or workmanship shall be returned to FirstFiber or authorized service location, as FirstFiber designates and shipping costs prepaid. Defective items will be repaired or replaced at FirstFiber’s option.
ISO9001:2008 The certificate shows that a component/subsystem can be used in a specific application according to a requirement class (RC) or a integrity level (SIL). The system integrator and end user must always be aware of how to use certified components/subsystems in safety-related function, respectively a safety instrumented system. Because of the many different possibilities and how to configure a safety system, the end user must get the related information from the manufacturer of the certified component/subsystem. |
CE The CE marking is a mandatory European marking for certain product groups to indicate conformity with the essential health and safety requirements set out in European. To permit the use of a CE mark on a product, proof that the item meets the relevant requirements must be documented.
|
|||
RoHS Working in partnership with the policy lead at BERR (The Department for Business, Enterprise & Regulatory Reform), NWML is the UK Enforcement Authority for the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2008 (the “RoHS Regulations”). Manufacturers need to understand the requirements of the RoHS Directive to ensure that their products, and their components, comply. |
FCC The Federal Communications Commission (FCC) is an independent United States government agency. The FCC was established by the Communications Act of 1934 and is charged with regulating interstate and international communications by radio, television, wire, satellite and cable. The FCC’s jurisdiction covers the 50 states, the District of Columbia, and U.S. possessions. |
- Информация
- Код товара: ff-980
Производитель
First Fiber
Максимальная рабочая дальность
70 км
ТЕХНИЧЕСКИЕ ХАРАКТЕРИСТИКИ
FF-980REV является комбинированным прибором с высокими характеристиками для тестирования ВОЛС и медножильных кабелей.
Функции
- оптический рефлектометр
- визуальный локатор дефектов
- измеритель оптической мощности
- источник оптического излучения
- тестирование сетевого кабеля RJ45 c возможностью определения длины
Оптический рефлектометр
Длительность импульса от 3 нс до 10 мкс
Диапазон отображения от 3 м до 64 км
Динамический диапазон 24/22 дБ 1310/1550 дБ
Число точек макс 65000
Линейность определения затухания≤ 0.05 дБ/дБ
Время усреднения 5 с, 15 с, 30 с, 60 с, 120 с, 180 с
Точность определения расстояния ± (1 м + расстояние * 3 * 10-5 + разрешение выборки) (исключая отклонения группового показателя)
Мертвая зона по определению события 3 м по затуханию 8 м Оптический разъем UPC
Визуальный локатор дефектов
Длина волны 650 ± 20 нм
Выходная мощность10 мВт
Измеритель оптической мощности
Длины волн калибровки 850/1300/1310/1490/1550/1625 нм
Диапазон мощности входного сигнала — 70 дБм ~ + 10 дБм
Точность измерения ± 0.5 дБ
Источник оптического излучения
Длина волны 1310/1550 нм
Выходная мощность — 5 дБм
Общие характеристики
Дисплей3.5″, цветной сенсорный дисплей
Автовыключение питания
Внутренняя память: 500 рефлектограмм
Поддерживается TF-карта
Рабочая температура- 10°С ~ + 60°С
Температура хранения- 25°С ~ + 70°С
Влажность< 95%
Входное напряжениеAC 100 — 200 В, 50-60 Гц
Тип батареи: литий-ионный аккумулятор, ёмкость 4000 мАч
Время работы от заряженного аккумулятора∼ 12 часов
Интерфейс USB, OTDR, VFL, OPM, RJ45, порт для зарядки
Размеры 220 х 125 х 100 мм
Вес 800 г
Комплект поставки
оптический рефлектометр FF-980REV — 1 шт
детектор — 1 шт
чехол для хранения и переноски — 1 шт
руководство пользователя — 1 шт
USB кабель — 1 шт
CD с ПО — 1 шт
адаптер питания — 1шт
адаптер FC/UPC — 1 шт
980PRO волоконно оптический OTDR тестер рефлектометр 4 в 1 OPM OLS VFL сенсорный экран FC SC ST
Высокая точность OTDR
(С прочным пластиковым чехлом для переноски)
Модель: FF-980PRO Длина волны: 1310/1550 нм
Динамический диапазон: 22/20 дБ диапазон тестирования: 3 м до 60 км
OTDR
1)С Визуальный дефектоскоп (VFL)
2)С Измеритель оптической мощности
3)С Оптический источник света
4)С Сенсорный экран
5)С Тестовый отчет печать программного обеспечения или сохранить как PDF
6)С Сертификат калибровки
7)С Разъемы SC FC ST
С Руководство пользователя
9)С Usb-кабель и usb-диск
Техническое обслуживание
Продажи (@) firstfiber.cn
Wechat/Whatsapp: + 86 18217747005
Skype ID: anker. yang88
Мы также ищем дистрибьюторов. Свяжитесь с нами, если у вас есть опыт продаж OTDR ….
Профессиональное оборудование для оптических сетевых систем FTTx и Metro
Поскольку волоконная оптика играет все более важную роль в современных телекоммуникациях и сетях CATV, требования к конструкции, испытанию и обслуживанию волоконно-оптических звеньев также становятся более заметными.
FF-980PRO-это уникальный продукт, который в основном предназначен для строительства и обслуживания телекоммуникационных сетей и сетей CATV.FF-980PROOTDR может широко использоваться в инженерном строительстве, техобслуживании и аварийном ремонте всех волоконно-оптических систем. По сравнению с обычным OTDR,FF-980PROOTDR является более компактным по размеру и более простым в использовании.
FF-980PROOTDR ручной дизайн, компактный и легкий, легко носить с собой. Информация о событиях через цветной дисплей TFT и возможности хранения данных. Через интерфейс USB, тестовые данные могут быть загружены на ПК, чтобы облегчить постобработку, хранение и печать.
В комплект входит
-1x OTDR,
-1x разъем FC
-1x SC разъем
-1x ST разъем,
-1x Руководство пользователя
-1x USB шнур
-1x USD диск
-1x программное обеспечение OTDRviewer,
-1x адаптер для зарядки
-1x Прочный пластиковый чехол для переноски
-1x сертификат калибровки
Общий | |
Дисплей | IPS сенсорный экран, 800x400px, 4 дюйма |
Интерфейс | 1 × USB, 1 xOTDR порт, 1 xVFL порт, 1 xPower Meter порт, 1 xзарядный порт |
Источник питания | 7,4 В/4400 мАч (dc), 100 в (ac) до 240 В (ac), 50 ~ 60 Гц |
Аккумулятор | Литиевая батарея (с сертификацией воздушного движения) Время работы: 8 часов, Telcordia GR-196-COR |
Энергосбережение | Выключение подсветки, автоматическое выключение |
Хранение данных | Внутренняя память: 200 кривых |
Язык | Английский по умолчанию |
Условия окружающей среды |
Рабочая температура и влажность:-10 ℃ ~ + 50 ℃, ≤ 95% (без конденсации) Температура хранения и влажность:-20 ℃ ~ + 75 ℃, ≤ 95% (без конденсации) Доказательство: IP65 (IEC 60529) |
Параметры отдр | |
Ширина импульса | 5ns до 20us |
Дальность действия | 3 м до 60 км |
Разрешение выборки | Минимум 16 см |
Точка выборки | Максимум 65 K |
Линейность | ≤ 0. 05дб/дБ |
Точность расстояния | ± (1 м + измерение distance× 2 × 10 ^-4 + разрешение выборки) (без учета скрытой неопределенности) |
Передняя Настройка | 1,0000 ~ 2,0000 |
Единицы измерения | Км, кфт, ФТ |
Формат отслеживания OTDR |
Telcordia universal, SOR, issue 2 (SR-4731) OTDR: выбор пользователя Автоматическая или Ручная настройка |
Волоконный анализ событий |
Определяемые пользователем пороговые значения пропуска/сбоя: -Светоотражающие и неотражающие события: от 0,01 до 1,99 дБ (от 0,01 дБ) -Светоотражающий: от 0,01 до 32 дБ (от 0,01 дБ) -Конец/разрыв волокна: от 3 до 20 дБ (1 дБ шагов) |
Визуальный локатор неисправности (VFL) | |
Длина волны (± 20 нм) | 650 нм |
Выходная мощность | 10 мВт, CLASSII B |
Диапазон | 15 км |
Измеритель оптической мощности | |
Длина волны | 850/1300/1310/1490/1550/1625 нм |
Диапазон тестирования | -70dBm ~ + 10dBm |
Точность | <± 3% (-10dBm, 22 ℃) |
Источник света | |
Длина волны | 1310/1550 нм |
Уровень мощности | -5dBm |
Точность | ± 0,04 @ 20 ℃ @ 15 мин |
Напоминание о кэшбэке: Что бы получить кешбек при покупке этого или другого товара на Aliexpress. Авторизуйтесь или зарегистрируйетсь в кэшбэк-сервисе, далее появиться подробная инструкция как получать кэшбэк при покупках на Алиэкспресс.
Отзывы покупателей
*о других товарах
Отзывы
Здесь вы можете оставить свой отзыв о данном товаре.