Oregon scientific 433mhz cable free инструкция

MULTI-CHANNEL

CABLE FREE

REMOTE THERMO SENSOR

MODEL: THC268

1

I

J

1

1

ENGLISH

USE’S MANUAL

INTRODUCTION

Congratulations on your purchasing the THC-268 Remote Thermo Sensor.

The Remote Thermo Sensor is used with the Oregon Scientific 433MHz

Multi-Channel In-Out Thermometers , Wireless Weather Stations, Weather

Clocks etc. to monitor temperature changes of remote or outdoor sites.

Operation is easy and no wire installation is required.

MAIN FEATURES:

A LCD

Displays the current temperature monitored by the remote unit and

indicates the selected channel

B LED INDICATOR

Flashes when the remote unit transmits a reading

C TEMPERATURE SENSOR PROBE

On 10 feet ( 3 meters ) cable.

D °C/°F SLIDE SWITCH

Selects between Centigrade ( °C ) and Fahrenheit ( °F )

E CHANNEL SLIDE SWITCH

Designates the remote unit Channel 1, Channel 2 or Channel 3

F RESET BUTTON

Returns all settings to default values

G BATTERY COMPARTMENT

Accommodates two AA-size batteries

H BATTERY DOOR

I WALL-MOUNT HOLDER

Supports the remote unit in wall-mounting

J REMOVABLE TABLE STAND

For standing the remote unit on a flat surface

COMPATIBLE PRODUCTS

Following is the list of some Oregon Scientific products that the THC268

is compatible with:

Cable Free Weather Forecaster with Thermo-Hygrometer and Radio

Controlled Clock: BAR122HGA

Cable Free Weather Forecaster with Thermo-Hygrometer, Radio Con-

trolled Clock and Ice Alarm: BAR913HGA

Cable Free Weather Station with Thermo-Hygrometer and Radio Con-

trolled Clock: BAR938HGA

Cable Free Thermo-Hygrometer: EMR963HG

Cable Free Thermometer with Radio Controlled Clock: RMR112

Cable Free Weather station: WMR968

Cable Free Weather station: WMR112

BEFORE YOU BEGIN

For best operation,

1. Assign different channels to different remote units.

2. Insert batteries for remote units before doing so for the main unit.

( Main unit of models listed under optional items )

3. Place the main unit as close as possible next to the remote unit, reset

the main unit after installing batteries. This will ensure easier

synchronization between the transmission and reception of signals.

4. Position the remote unit and main unit within effective transmission

range, which, in usual circumstances, is 20 to 30 meters(upto 100 feet).

Note that the effective range is vastly affected by the

building materials and where the main and remote units are

positioned. Try various setups for best result.

Though the sensor is weather proof and meant to be used outdoors,

it should be placed away from direct sunlight, rain or snow.

BATTERY AND CHANNEL INSTALLATION

The remote unit uses two AA-size batteries. To install them,

1. Remove the screws on the battery compartment.

2. Select the channel number on the CHANNEL slide switch.

3. Select the temperature display unit on the °C/°F slide switch.

4. Insert the batteries strictly according to the polarities shown inside.

5. Replace the battery compartment door and secure its screws.

CHANGE CHANNEL

Once a channel is assigned to a unit, you can only change it by removing

the batteries and repeating the above procedure.

LOW-BATTERY WARNING

Replace the batteries of the sensor when the low-battery indicator of the

channel represented by the sensor shows up on the main unit.

OPERATION

Once batteries are in place, the sensor will start transmitting samplings

at 40-second intervals.

The current temperature will be shown on the LCD in the selected unit

( °C/°F ) at the designated channel. The unit ( °C/°F ) shown on the main

unit is determined by the setting on the main unit.

HOW TO INSTALL THE TEMPERATURE

SENSING CABLEG

Secure the sensor to an area you want to monitor. Do not expose it to

direct sunlight.

THE RESET BUTTON

See the user’s manual of your main unit for further information.

This button is only used when the unit is operation in an unfavorable

way or malfunctioning. Use a blunt stylus to hold down the button. All

settings will return to their default values.

HOW TO USE THE TABLE STAND OR WALL

MOUNTING

This sensor comes with a wall-mount holder and a removable stand.

Use either to set up the unit.

PRECAUTIONS

This product is engineered to give you years of satisfactory service if

you handle it carefully. Here are a few precautions:

1. Do not immerse the unit in water.

2. Do not clean the unit with abrasive or corrosive materials. They may

scratch the plastic parts and corrode the electronic circuit.

3. Do not subject the unit to excessive force, shock, dust, temperature

or humidity, which may result in malfunction, shorter electronic life

span, damaged battery and distorted parts.

4. Do not tamper with the unit’s internal components. Doing so will

invalidate the warranty on the unit and may cause unnecessary dam-

age. The unit contains no user-serviceable parts.

5. Only use fresh batteries as specified in the user’s manual. Do not mix

new and old batteries as the old ones may leak.

6. Always read the user’s manual thoroughly before operating the unit.

SPECIFICATIONS

Temperature Measurement

Displayed range

: -50.0°C to + 70.0°C

( -58.0°F to 158.0°F )

Proposed operating range

: -20.0°C to + 60.0°C

( 4.0°F to 140.0°F )

Temperature resolution

: 0.1°C ( 0.2°F )

RF Transmission Frequency

: 433 MHz

No. of Remote unit

: Maximum of 3

RF Transmission Range

: Maximum 30 meters (100 feet)

Temperature sensing cycle

: around 40 seconds

Power

: use 2 pcs UM-3 or «AA»

1.5V alkaline battery

Weight

: 80.5 g (2.84ounces)

Dimension

: 105 x 70 x 21mm

(4.13 x 2.76 x.83 inches)

NOTE ON COMPLIANCE

This device complies with Part 15 of the FCC Rules. Operation is sub-

ject to the following two conditions: (1) This device may not cause

harmful interference, and (2) This device must accept any interference

received, including interference that may cause undesired operations.

Warning: Changes or modifications to this unit not expressly approved

by the party responsible for compliance could void the user’s authority

to operate the equipment.

FCC :

NOTE: This equipment has been tested and found to comply with the

limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.

These limits are designed to provide reasonable protection against harmful

interference in a residential installation. This equipment generates, uses

and can radiate radio frequency energy and, if not installed and used in

accordance with the instructions, may cause harmful interference to

radio communications.

However, there is no guarantee that interference will not occur in a

particular installation. If this equipment does cause harmful interference

to radio or television reception, which can be determined by turning the

equipment off and on, the user is encouraged to try to correct the inter-

ference by one or more of the following measures:

orient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that

to which the receiver is connected.

Consult the dealer of an experienced radio/TV technician for help.

Company Name: Oregon Scientific, Inc.

Address: 19861 SW 95th Place, Tualatin, Oregon 97062, USA

Telephone Number: 1-800-853-8883

CUSTOMER ASSISTANCE

Should you require assistance regarding this product and its operation,

please contact our customer care department at 800-853-8883 or via

email at helpme@oscientific.com.

CAUTION

— The content of this manual is subject to change without

further notice.

— Due to printing limitation, the displays shown in this

manual may differ from the actual display.

— The contents of this manual may not be reproduced

without the permission of the manufacturer.

WARRANTY

This product is warranted to be free of defects in manufacturing

for 90 days after purchase. For technical support please call

800-853-8883 ( Monday-Friday; 8am-5pm PST ).

Defective product returns should be directed to the place of retail

purchase. If this is not possible, all direct returns must include a

Return Authorization Number from Oregon Scientific, together

with proof of purchase date, your name and address, shipped

prepaid to Oregon Scientific Inc, 19861 SW 95th place Tualatin,

OREGON 97062, USA.

This warranty does not cover a product subjected to abuse,

misuse of accidental damage.

background image

1

GB

MULTI-CHANNEL IN-OUT

CABLE FREE THERMOMETER

MODEL: EMR812

USER’S MANUAL

INTRODUCTION

Congratulations on your purchase of the EMR812 Multi-Channel
In-Out Thermometer with 433MHz cable free sensor.

The EMR812 is an easy-to-use, state-of-the-art thermometer. The
basic package comes with a main unit, which is the temperature
station, and a remote unit, the thermo sensor.

The main unit has extra-large read-outs for indoors temperature
and for that collected and transmitted by the remote unit. The main
unit can support up to three remote units.

The main unit is capable of monitoring temperature changes of
remote sites. By setting the upper and lower temperature limits the
alarm will activate when those limits are exceeded. Also, the maxi-
mum and minimum temperature of different sites can also be
retrieved quickly.

No wire installation is required between the main and remote units.
As the EMR812 operates at 433MHz, it can be used in the U.S. and
most places in Continental Europe.

MAIN FEATURES: MAIN UNIT

H I

O N /O FF

R ESET

T EM P AL

° C

° F

L O

C H A N N E L

M E M

C LE A R

4 3 3 M H z C A B L E F R E E

1

GB

Long-Range Multi-Channel

In-Out Thermometer

with Cable Free Sensor and RF Clock

MODEL: RMR183/RMR183U

USER’S MANUAL

INTRODUCTION

Congratulations on your purchase of the RMR183/RMR183U

Long-Range (60 meters) Multi-Channel In-Out Thermometer with

433MHz cable free sensor and radio-controlled calendar clock.

The basic package comes with a main unit, which is the temperature

and calendar clock station, and a remote unit, the thermo sensor.

The main unit has a large display for indoor temperature,

calendar clock and temperatures collected and transmitted by the

remote unit. The main unit can support up to three remote units.

The main unit is capable of keeping track of the maximum and

minimum temperature of different sites. No wire installation is

required as the RMR183/RMR183U operates at 433MHz.

As for the calendar clock, it is radio-controlled. It automatically

synchronizes its current time and date when it is brought within

an approximate 1500km radius of the radio signal generated from

Frankfurt, Germany (DCF77) (or Radio signal MSF-60 from

Rugby, England for UK version).

You can also set the calendar clock manually when it is off range.

Other features include five-language display, crescendo daily

alarm and interchangeable display modes.

MAIN FEATURES: MAIN UNIT

Смотреть руководство для Oregon Scientific RMR112 ниже. Все руководства на ManualsCat.com могут просматриваться абсолютно бесплатно. Нажав кнопку «Выбор языка» вы можете изменить язык руководства, которое хотите просмотреть.

MANUALSCAT | RU

Вопросы и ответы

У вас есть вопрос о Oregon Scientific RMR112, но вы не можете найти ответ в пользовательском руководстве? Возможно, пользователи ManualsCat.com смогут помочь вам и ответят на ваш вопрос. Заполните форму ниже — и ваш вопрос будет отображаться под руководством для Oregon Scientific RMR112. Пожалуйста, убедитесь, что вы опишите свои трудности с Oregon Scientific RMR112 как можно более детально. Чем более детальным является ваш вопрос, тем более высоки шансы, что другой пользователь быстро ответит на него. Вам будет автоматически отправлено электронное письмо, чтобы проинформировать вас, когда кто-то из пользователей ответит на ваш вопрос.

Добрый день. Скажите где я могу купить датчик для этой станции? Спасибо.

Константин 2019-11-22

Задать вопрос о Oregon Scientific RMR112

Бренд:
Oregon Scientific
Продукт:
термометры
Модель/название:
RMR112
Тип файла:
PDF
Доступные языки:
английский

Сопутствующие товары Oregon Scientific RMR112

GB

Multi-Channel IN-OUT Thermometer

with Cable Free Sensor and RF Clock

MODEL: RMR112

USER’S MANUAL

INTRODUCTION

Congratulations on your purchase of the RMR112 Multi-Channel In-Out Thermometer with 433MHz cable free sensor and radio-controlled calendar clock.

The basic package comes with a main unit, which is the temperature and calendar clock station, and a remote unit, the thermo sensor.

The main unit has large read-outs for indoors temperature, calendar clock and temperatures collected and transmitted by the remote unit. The main unit can support up to three remote units.

The main unit is capable of keeping track of the maximum and minimum temperature of different sites. And no wire installation is required and the RMR112 operates at 433MHz.

As for the calendar clock, it is radio-controlled. It automatically synchronizes its current time and date when it is brought within an approximate 1500km radius of the radio signal generated from Frankfurt, Germany (DCF77).

You can also set the calendar clock manually when it is off range. Other features include four-language display, four-step crescendo dual alarms and interchangeable display modes.

MAIN FEATURES

1

GB

AFOUR-LINE DISPLAY

Facilitates easy reading of remote and indoors temperatures and calendar clock

BCHANNEL BUTTON

Selects among different channels

CMEMORY BUTTON

Recalls the maximum or minimum temperature of individual channels

D ALARM [24HR OFF] BUTTON

Sets the time for the alarms

EMODE/SET BUTTON

Toggles the display modes and confirms entry while setting the values for display

FRADIO RECEPTION SIGNAL

Indicates the condition of radio reception

GUP ( ) BUTTON

Advances the value of a setting

HDOWN ( ) BUTTON

Decreases the value of a setting

I ALARM [ AL ON/OFF] BUTTON

Enables or disables the alarms

J RESET BUTTON

Returns all settings to default values

K ° C/° F SLIDE SWITCH

Selects between degree Centigrade ( C) and Fahrenheit° (° F)

2

L BATTERY COMPARTMENTS

Accommodates two UM-3 or “AA” size 1.5V alkaline batteries

MREMOVABLE TABLE STAND

For standing the main unit on a flat surface

NWALL-MOUNT RECESSED HOLE

For mounting the main unit on a wall

MAIN FEATURES: REMOTE UNIT

ALCD

Displays the current temperature monitored by the remote unit

BLED INDICATOR

Flashes when the remote unit transmits a reading

C° C/° F SLIDE SWITCH

Selects between Centigrade (° C) and Fahrenheit (° F)

DCHANNEL SLIDE SWITCH

Designates the remote unit Channel 1, Channel 2 or Channel 3

GB

reset the main unit after installing batteries. This will ensure easier synchronization between the transmission and reception of signals.

4.Position the remote unit and main unit within effective transmission range, which, in usual circumstances, is 20 to 30 meters.

Note that the effective range is vastly affected by the building materials and where the main and remote units are positioned. Try various set-ups for best result.

Though the remote units are weather proof, they should be placed away from direct sunlight, rain or snow.

ERESET BUTTON

Returns all settings to default values

FBATTERY COMPARTMENT

Accommodates two AAA-size batteries

GBATTERY DOOR

HWALL-MOUNT HOLDER

Supports the remote until in wall-mounting

IMOVABLE TABLE STAND

For standing the remote unit on a flat surface

BEFORE YOU BEGIN

BATTERY AND CHANNEL INSTALLATION: REMOTE UNIT

1.Remove the screws on the battery compartment.

2.Select the channel number on the CHANNEL slide switch.

3.Select the temperature display unit on the C/F slide switch.

For best operation,

1.Assign different channels to different remote units.

2.Insert batteries for remote units before doing so for the main unit.

3.Place the main unit as close as possible next to the remote unit,

4.Install 2 alkaline batteries (UM-4 or “AAA” size 1.5V) strictly according to the polarities shown.

5.Replace the battery compartment door and secure its screws.

3

Oregon Scientific RMR112 User Manual

GB

Note that once a channel is assigned to a remote unit, you can only change it by removing the batteries or resetting the unit.

BATTERY INSTALLATION: MAIN UNIT

1.Slide open the battery compartment door.

2.Install 2 alkaline batteries (UM-3 or “AA” size 1.5V) strictly according to the polarities shown.

3. Replace the battery compartment door.

HOW TO USE THE TABLE STAND

OR WALL MOUNTING

The main unit has a removable table stand, which when connected, can support the unit on a flat surface. Or you can remove the stand and mount the unit on a wall using the recessed screw hole.

As for the remote unit, it comes with a wall-mount holder and a removable stand. Use either to hold the unit in place.

Main unit

LOW BATTERY WARNING

When it is time to replace batteries, the respective low-battery indicator will show up when the respective channel is selected. The battery level of the main unit will be shown on the indoor temperature when it is running low.

4

Loading…

You can only view or download manuals with

Sign Up and get 5 for free

Upload your files to the site. You get 1 for each file you add

Get 1 for every time someone downloads your manual

Buy as many  as you need

Понравилась статья? Поделить с друзьями:
  • Въезд в гараж справа на автодроме пошаговая инструкция
  • Паста с цинком инструкция по применению взрослым
  • Коэнзим в ампулах инструкция по применению цена отзывы аналоги
  • Fighter 90 инструкция по эксплуатации скачать
  • Гомогенизатор сливочного масла м6 ога инструкция по эксплуатации