SHDSL.bis
Up to 60Mbps
Ddd
E1 / Nx64 /Ethernet
FlexDSL Orion3
The FlexDSL Orion3 product family offers a broad range of products, which are based on the latest SHDSL.bis standards
(ITU-T G.991.2 & ETS TS 101 524) The FlexDSL Orion3 supports TC-PAM16/32 and the new TC-PAM4/8/64/128 line coding.
The FlexDSL Orion3 allows symmetrical data and voice transmission at speeds up to 15.2Mbps over a single pair of copper.
In addition, the FlexDSL Orion3 supports DSL channel bonding for up to 4 copper pairs in order to achieve speeds to
60.8Mbps. The SFP module (available on selected models) allows Ethernet data transmission over mixed Copper and Fiber
media.
FlexDSL Orion3 SHDSL.bis Extended modems can provide up to 2 E1 interfaces, which support framed and unframed
services (G.703/G.704). An integrated 2 or 4 port Ethernet layer 2 managed Switch with VLAN support (10/100BaseT)
ensures connectivity to IP services. Beside of E1 and Ethernet the additional Nx64 interfaces can be configured as V.35, V.36,
X.21, V.28, or RS232/RS485 interface (cable selectable).
Like all FlexDSL Orion products, the Orion3 SHDSL.bis modems family is based on industrial components, have extended
temperature range, advanced surge protection and produced in Switzerland.
Possible Applications
a)
b)
FlexDSL Telecommunications AG
Steinackerstrassse 31
8902 Urdorf
Switzerland
Features
•
Up to 15Mbps Data Transmission per Copper Pair
•
SHDSL and SHDSL.bis, TC-PAM16/32
•
Additional TC-PAM4/8/64/128 Available
•
1, 2 or 4 Copper Pairs Support
•
2 or 4 Port Ethernet Switch (10/100BaseT)
•
SFP connector for mixed Copper and Fiber applications
•
QoS, VLAN and RSTP Support
•
E1 (G.703/704, Balanced/Unbalanced)
•
Nx64 (V.35, V.36, X.21, V.28) and RS-232/485
•
Multi-Service Operation
•
Point-to-Point and Point-to-Multipoint Operation
•
Console Port, Telnet, Web, SNMP Management
•
24/48VDC Powered, Low Power Consumption
•
Included Primary Protection
•
Robust DIN-Rail Metal Enclosure
•
Industrial Temperature Range Available
a) Ethernet Transmission Point-to-Point
b) Ethernet Transmission Point-to-Multipoint
c) Ethernet Add/Drop over a Long Copper Line
d) Ethernet Transmission over Copper and Fiber
Page 1/9
c)
d)
Tel: +41 44 741 52 90
Fax: +41 44 741 52 93
Email: info@flexdsl.ch
Web: www.flexdsl.ch
- Manuals
- Brands
- FlexDSL Manuals
- Repeater
- ORION 3
Manuals and User Guides for FlexDSL ORION 3. We have 2 FlexDSL ORION 3 manuals available for free PDF download: Technical Description And Operations Manual
FlexDSL ORION 3 Technical Description And Operations Manual (129 pages)
REPEATER DEVICES
Brand: FlexDSL
|
Category: Repeater
|
Size: 3.5 MB
Table of Contents
-
User Manual RR Orion
2
-
Table of Contents
3
-
Version Control
7
-
Safety Regulations
7
-
Eu Directive 2002/96/Ec and En50419
7
-
1 Selection Guide
8
-
2 Precaution
9
-
3 Technical Description
10
-
General Information about Flexdsl Orion3
10
-
Description of Orion3 RR (Repeater) Devices
11
-
ABS Plastic & DIN-Rail Enclosure (IP 20/30)
12
-
Polycarbonate Plastic & Die-Cast Aluminum Enclosure (IP 67/68)
14
-
Remote Power Supply and Wetting Current
18
-
Compatibility of Remote Power and Wetting Current Supply Modes
18
-
Configuration of Remote Power
19
-
-
Description of Orion3 Interfaces
20
-
SHDSL Interface
20
-
Master/Slave
21
-
Multipair Mode
21
-
Reservation Mode
22
-
Automatic Configuration of a Link
25
-
-
E1 Interface (G.703/704)
27
-
Ethernet Interface
27
-
MAC Filter
30
-
MAC Filter Rules
31
-
-
Rapid Spanning Tree Protocol
31
-
-
An Integrated Switch of 64-Kbit/S Time Slots
33
-
E1 Transmission Mode (Only E1 Time Slots)
33
-
E1, Nx64/Rs-232/RS-485 and Ethernet Simultaneous Transmission Mode
33
-
-
Test Loops
34
-
Analogue Loop Back
35
-
Performance Monitoring
35
-
-
BERT Test
36
-
-
Alarm Indication
37
-
Leds
37
-
Alarm Leds
38
-
-
Management of Orion 3 Devices
39
-
Management by Local Craft Terminal or MONITOR Interface (RS-232, USB )
39
-
Management by Ethernet Interface
40
-
Telnet
40
-
Web
40
-
Snmp
43
-
Ssh
45
-
Radius
46
-
RADIUS Server Setup with Defined Vendor Specific Attributes
47
-
Simplified RADIUS Server Setup
48
-
Configuring User Access Rights
49
-
-
Lldp
51
-
-
-
-
4 Programming Guide
52
-
Command Structure
52
-
Orion3 Software
53
-
Configuration and Application Storage
53
-
Groups of Commands Requiring Confirmation
55
-
Command Syntax
56
-
Commands
57
-
Main Menu
57
-
System Invitation
57
-
-
-
General Commands
58
-
H> Command
58
-
APPLY [ALL/GROUP]> Command
58
-
Connect N:1
58
-
LINK [SN/00/FE]> Command
58
-
LINKCLEAR> Command
58
-
-
Performance Management Menu
59
-
H> Command
59
-
G826> Command
59
-
RESETG826> Command
60
-
NETSTAT [LAN/WAN]> Command
60
-
NETERR [LAN/WAN]> Command
61
-
RESETNETSTAT> Command
61
-
M> Command
61
-
-
Fault and Maintenance Management Menu
62
-
H> Command
62
-
NM> Command
62
-
STATUS> Command
63
-
STATUS ETH> Command
63
-
STATUS LLDP> Command
64
-
STATUS RADIUS> Command
64
-
STATUS ENCODE> Command
64
-
ALARM> Command
65
-
AСO [GROUP ON/OFF])> Command
66
-
MACTABLE> Command
66
-
Lldp Stat [If/All]
67
-
STARTAL [N]> Command
68
-
Restart [N=1
68
-
RESET> Command
68
-
CONFIRM> Command
68
-
BACKUP> Command
68
-
RESTORE> Command
68
-
DIFF N/R/S/B N/R/S/B> Command
69
-
DUMP N/R/S/B> Command
69
-
LOAD> Command
70
-
TLM> Command
70
-
SENSOR> Command
70
-
Sensor [N=1
70
-
LOG> and [LOG C] Command
71
-
SOFTUPDATE> Command
71
-
TFTP [CMD] [ARG1][ARG2]> Command
71
-
SOFTCONFIRM> Command
72
-
SOFTINFO> Command
72
-
PING X.X.X.X> Command
72
-
MODEMVIEW> Command
72
-
SD SNAPSHOT> Command
72
-
SD DIR> Command
72
-
SD del [NAME]> Command
73
-
Sd Save [N=0
73
-
Sd Load [N=0
73
-
SD BOOT [ON/OFF]> Command
73
-
SD STATUS> Command
73
-
-
Configuration Management Menu
75
-
H> Command
75
-
ENCODE [NRSB]> Command
75
-
ENCODE KEY [N]> Command
76
-
ENCODE [ON/OFF] [N]> Command
76
-
SECURE ON/OFF> Command
77
-
USERS> Command
77
-
USER> Command
77
-
PASSWORD {Users}> Command
79
-
CONFIG /N/R/S/B> Command
80
-
MASTER [1/2/AUTO] [N=1/2]> Command
80
-
-
Ext On/Off [N = 1
81
-
BASERATE [M/AUTO] [N=1/2]> Command
81
-
PAM [16/32] [N]> or <PAM [4-128] [N]> Command
81
-
ANNEX A/B/AB [N=1/2]> Command
82
-
MULTIPAIR [2/OFF]> Command
82
-
ID [String]> Command
82
-
DEFAULT [0-3]> Command
82
-
DEFAULT EVERYTHING> Command
82
-
DEFAULT DESC> Command
82
-
SERNUM> Command
82
-
Wan [N/Auto/None] [K=1/2]
82
-
GSCOMPAT ON/OFF> Command
83
-
NMTHR> Command
83
-
LATHR> Command
83
-
PTMP [ADD/DEL] [IF]> Command
83
-
PTMP SHOW> Command
83
-
MODE N> Command
83
-
LICENSE> Command
83
-
LICENSE ADD> Command
84
-
NET> Command
84
-
H> Command
84
-
NETCONFIG [N/R/S/B]> Command
85
-
COSCONFIG> Command
86
-
RSTP DEFAULT> Command
87
-
Rstp [A
88
-
Rstp [Iface] Prio [0
88
-
Rstp [Iface] Pcost [Auto/1
88
-
RSTP [A..E] [ON/OFF]> Command
88
-
RSTP [IFACE] EDGE [ON/OFF]> Command
89
-
RSTP CONF> Command
89
-
RSTP STATE> Command
89
-
RSTP DIAG> Command
90
-
Pbvlan [If] [A
91
-
MODE [IF] [ACC/TRUNK/MIX]> Command
92
-
Vlan [If] [1
92
-
Qos [If] [0
92
-
ALLOW [IF] [VLAN List]> Command
92
-
VID [1-8] ID> Command
93
-
MACLIST SHOW> Command
93
-
MACLIST [IF] ADD [MAC]> Command
93
-
MACLIST [IF] del [MAC/N]> Command
94
-
MACFILTER [LAN1-5] [ON/OFF]> Command
94
-
MACRULE [LAN1-5] [RULE]> Command
94
-
SETIP X.X.X.X> Command
95
-
NETMASK X.X.X.X> Command
95
-
GATEWAY X.X.X.X> Command
95
-
MTU> Command
95
-
WANIDLE [1/7E]> Command
95
-
Ethsd [10H/10F/100H/100F/Auto/Off] [N=1
95
-
FC [ON/OFF] [N1-4]> Command
96
-
IRATE [Speed/Off] [N1-4]> Command
96
-
ERATE [Speed/Off]> Command
97
-
CRATE [Speed] [Cos] [WAN]> Command
97
-
Cos [Qos/Vlan] [N] [0
97
-
SNMPACL> Command
97
-
SNMP [V1|V2C|V3] [ON|OFF]> Command
98
-
TRAPIP [1/2] [IP/OFF]> Command
98
-
TRAP [1/2] [V1/V2C]> Command
98
-
TRAP [1/2] V3 [RO/RW]> Command
98
-
COMMUNITY> Command
98
-
SNMPSET [ON/OFF]> Command
98
-
SNMP [RO|RW] NAME> Command
98
-
SNMP [RO|RW] AUTH [MODE]> Command
99
-
SNMP [RO|RW] PRIV [MODE]> Command
99
-
SYSLOG [1/2] [IP/OFF]> Command
99
-
LLDP [ON/OFF]> Command
99
-
LLDP DEFAULT> Command
100
-
LLDP [PARAM] [VALUE]> Command
100
-
LLDP [RX/TX] [ON/OFF]> Command
101
-
LLDP INT VLAN [ON/OFF]> Command
101
-
LLDP CONFIG> Command
101
-
SNTP [1/2] [IP/OFF]> Command
101
-
SNTP TZ [+/-]HH:MM> Command
101
-
DST> Command
102
-
[Ssh|Telnet|Http|Https] [On/Off]
104
-
Ssh Port [N]
104
-
SSL [SHOW/DEL] [Options]
105
-
Radius [1/2] Secret
105
-
Radius [1/2] Test
105
-
Radius [1/2] [Ip:p/Off]
106
-
Radius Retries [0
106
-
Radius Timeout [1
106
-
STATUS RADIUS [N/R/S/B]> Command
107
-
NETDEFAULT> Command
107
-
-
-
5 Software Download
109
-
Software Download Via RS-232, USB Port (LCT) Using the Flash Loader Program
109
-
Software Download Via RS-232, USB COM Port (LCT) Using Xmodem Protocol
113
-
Software Download Via Ethernet (1K-Xmodem and Telnet)
116
-
-
6 Service Instructions
117
-
General Requirements
117
-
Evaluation of the Digital Channel Quality and Operation Parameters
117
-
-
7 Appendices
119
-
Quick Installation Guide for Orion3 NTU & RR Devices
119
-
Enter an Orion3 Device
119
-
Configure an Orion3 NTU Device (Link)
119
-
Configure an Orion3 RR Device (Repeater Between)
121
-
Checking of Correct Working
123
-
Problem with Orion3 Device
123
-
-
Connector Description
124
-
Ethernet Connector
124
-
SHDSL Connector
124
-
Monitor (LCT, Local Craft Terminal) Connector
125
-
48VDС Connector
126
-
-
-
8 Technical Specification
127
-
Interfaces
127
-
SHDSL Line Interface
127
-
Monitor or Local Craft Terminal (RS-232) Interface
127
-
Alarm at Local Craft Terminal (RS-232) Interface
127
-
Monitor or Local Craft Terminal (USB) Interface
127
-
Ethernet
127
-
-
Power Supply
128
-
Environment
128
-
Climatic Conditions
128
-
EMC and Safety Standards
128
-
-
Physical Dimensions and Weight
128
-
Advertisement
FlexDSL ORION 3 Technical Description And Operations Manual (160 pages)
LTU DEVICES
Brand: FlexDSL
|
Category: Modem
|
Size: 4.82 MB
Table of Contents
-
User Manual LTU Orion
2
-
Table of Contents
3
-
Version Control
8
-
Eu Directive 2002/96/Ec and En5041
9
-
1 Selection Guide
10
-
2 Precaution
11
-
3 Technical Description
12
-
Description of Orion3 LTU Devices
13
-
Remote Power Supply and Wetting Current
14
-
Description of Orion3 Interfaces
17
-
Multipair Mode
18
-
Reservation Mode
19
-
Automatic Configuration of a Link
22
-
E1 Interface (G.703/704)
24
-
Nx64, RS-232/RS-485 and G.703/E0 Interfaces
26
-
Nx64 Clocking Modes
27
-
Automatic V.54 Loops
28
-
-
Ethernet Interface
29
-
MAC Filter
32
-
MAC Filter Rules
33
-
IEEE 802.1X Device Settings
34
-
-
Radius
35
-
RADIUS Server Setup with Defined Vendor Specific Attributes
36
-
Simplified RADIUS Server Setup
38
-
RADIUS Server Setup with Defined Service-Type Attribute
39
-
-
Lldp
41
-
-
An Integrated Switch of 64-Kbit/S Time Slots
42
-
Test Loops
43
-
Analogue Loop Back
44
-
-
BERT Test
45
-
-
Alarm Indication
46
-
Alarm Leds
47
-
-
Management of Orion 3 Devices
49
-
Management by Ethernet Interface
50
-
Snmp
54
-
-
-
-
4 Programming Guide
57
-
Orion3 Software
59
-
Groups of Commands Requiring Confirmation
61
-
Commands
62
-
General Commands
63
-
Performance Management Menu
64
-
ALLG826 N> Command
66
-
NETSTAT [LAN/WAN]> Command
67
-
RESETNETSTAT> Command
68
-
LINKALARM> Command
69
-
M> Command
70
-
-
Fault and Maintenance Management Menu
71
-
NM> & <LINKNM> Command
72
-
STATUS ETH> Command
73
-
STATUS RADIUS> Command
74
-
LOOP1 ON/OFF [N=1..4]> Command
75
-
MACTABLE> Command
77
-
Lldp Stat [If/All]
78
-
STARTAL [N]> Command
79
-
DIFF N/R/S/B N/R/S/B> Command
80
-
LOAD> Command
81
-
TLM S [N:[Rnn-Rkk]] [ABC]> Command
82
-
LOG> and [LOG C] Command
83
-
TFTP [CMD] [ARG1][ARG2]> Command
84
-
SOFTINFO> Command
85
-
SD SAVE [N=0..9]> Command
86
-
H> Command
87
-
-
Configuration Management Menu
88
-
ENCODE [NRSB]> Command
89
-
ENCODE [ON/OFF] [N]> Command
90
-
PASSWORD {Users}> Command
93
-
MASTER ON/OFF [N = 1..4]> Command
95
-
BASERATE K/AUTO [N=1..4]> Command
96
-
ANNEX A/B/AB [N=1..4]> Command
97
-
G704 ON/OFF [N]> Command
98
-
E1MODE [HDB3/AMI] [N]>, <E1MODE [SHORT/LONG] [N]> Commands
99
-
GSCOMPAT ON/OFF> Command
100
-
LICENSE> Command
101
-
RSRATE [N]> Command
104
-
IOIP {OPTION} [IF]> Command
105
-
NET> Command
107
-
NETCONFIG [N/R/S/B]> Command
108
-
COSCONFIG [N/R/S/B]> Command
110
-
RSTP DEFAULT> Command
111
-
RSTP [A..E] HELLO [2..10]> Command
112
-
Rstp [Iface] Ma [6..40]
113
-
RSTP [IFACE] PCOST [AUTO/1..200000000]> Command
114
-
RSTP STATE> Command
115
-
RSTP DIAG> Command
116
-
MODE [IF] [ACC/TRUNK/MIX]> Command
117
-
QOS [IF] [0..7]> Command
118
-
MACLIST [IF] ADD [MAC]> Command
119
-
MACFILTER [LAN1-5] [ON/OFF]> Command
120
-
SETIP X.X.X.X> Command
121
-
FC [ON/OFF] [N1-4]> Command
122
-
ERATE [Speed/Off]> Command
123
-
COS [QOS/VLAN] [N] [0..3/OFF]> Command
124
-
TRAP [1/2] [V1/V2C]> Command
125
-
SNMP [RO|RW] PRIV [MODE]> Command
126
-
LLDP [PARAM] [VALUE]> Command
127
-
LLDP CONFIG> Command
128
-
Ssh|Telnet|Http|Https] [On/Off]
131
-
Radius [1/2] Secret
132
-
Radius Retries [0..10]
133
-
NETDEFAULT> Command
134
-
-
Software Download
135
-
Software Download Via RS-232 COM Port (LCT) Using Xmodem Protocol
139
-
Software Download Via Ethernet (1K-Xmodem and Telnet)
142
-
Service Instructions
143
-
Appendices
145
-
Checking of Correct Working
148
-
Connector Description
149
-
E1 75 Ohm Connector
151
-
Monitor (LCT, Local Craft Terminal) Connector (ACU, Minirack, Uttx)
156
-
Digital Input / Output Interface (4I4O) Connector
157
-
Technical Specification
158
-
Monitor or Local Craft Terminal (RS-232) Interface
159
-
Environment
160
-
-
Advertisement
Related Products
-
FlexDSL Orion3
-
FlexDSL ORION 2
-
FlexDSL ORION 2+
-
FlexDSL Orion2
FlexDSL Categories
Modem
Repeater
Industrial Equipment
More FlexDSL Manuals
Detail Specifications: 1301/1301100-orion3.pdf file (31 Mar 2023) |
Accompanying Data:
FlexDSL Orion3 Modem PDF Manual (Updated: Friday 31st of March 2023 10:22:57 AM)
Rating: 4.6 (rated by 25 users)
Compatible devices: 6511, Z288L, Unite II, BIPAC 7000, MiniFlex SHDSL, F8X14 Series, duoPlus 300WR, ORION 3.
Recommended Documentation:
Text Version of Manual
(Ocr-Read Summary of Contents, UPD: 31 March 2023)
-
1, FlexDSL Orion3 FlexDSL Telecommunications AG Steinackerstrassse 31 8902 Urdorf Switzerland Page 1/9 Tel: +41 44 741 52 90 Fax: +41 44 741 52 93 Email: [email protected] Web: www.flexdsl.ch Ddd The FlexDSL Orion3 product family offers a broad range of products, which are based on the latest SHDSL.bis standards (ITU-T G.991.2 &…
-
2, FlexDSL Telecommunications AG Steinackerstrassse 31 8902 Urdorf Switzerland Page 2/9 Tel: +41 44 741 52 90 Fax: +41 44 741 52 93 Email: [email protected] Web: www.flexdsl.ch Quick Installation Guide Enter an Orion3 Device You can use the Monitor (Local Craft Terminal, RS-232) interface with Hyper Terminal (or any equal program) or you can address the device with T…
-
3, FlexDSL Telecommunications AG Steinackerstrassse 31 8902 Urdorf Switzerland Page 3/9 Tel: +41 44 741 52 90 Fax: +41 44 741 52 93 Email: [email protected] Web: www.flexdsl.ch Enter in device 2 with the Monitor (LCT, RS-232 or USB) or Telnet interface. Type following commands Description 3 <> Go to Configuration Management (CM) <DEF…
-
4, FlexDSL Orion3 FlexDSL Telecommunications AG Steinackerstrassse 31 8902 Urdorf Switzerland Page 4/9 Tel: +41 44 741 52 90 Fax: +41 44 741 52 93 Email: [email protected] Web: www.flexdsl.ch Connector Description SHDSL Technical Specification SHDSL Connector Specification Specification ITU-T G.991.2 G.shdsl and G.shdsl.bis Pin No Description Line…
-
5, FlexDSL Telecommunications AG Steinackerstrassse 31 8902 Urdorf Switzerland Page 5/9 Tel: +41 44 741 52 90 Fax: +41 44 741 52 93 Email: [email protected] Web: www.flexdsl.ch Nx64 Interface DB-26H Connector Specification Specification V.35/V.36/X.21/V.28 Pin No V.35/36/28 X.21 Data Rate 1..128x64kbps (synchronous) for V.35/V.36/X.21 1 Mode Sel 2 1…
-
6, FlexDSL Telecommunications AG Steinackerstrassse 31 8902 Urdorf Switzerland Page 6/9 Tel: +41 44 741 52 90 Fax: +41 44 741 52 93 Email: [email protected] Web: www.flexdsl.ch RS-232(V24)/RS-485 Interface DB-26H Connector Specification Specification RS-232/485 Pin No RS-232 RS-485 Data Rate 1200..256000 bps (asynchronous) 1 DTR Format RS-232/RS-485…
-
7, FlexDSL Telecommunications AG Steinackerstrassse 31 8902 Urdorf Switzerland Page 7/9 Tel: +41 44 741 52 90 Fax: +41 44 741 52 93 Email: [email protected] Web: www.flexdsl.ch Panel Description Connector LED RED GREEN AMBER OFF xDSL 1 (DSL No 1) Left DSL not working DSL normal operation xDSL 1 (DSL No 3, only V84) Right…
-
8, FlexDSL Telecommunications AG Steinackerstrassse 31 8902 Urdorf Switzerland Page 8/9 Tel: +41 44 741 52 90 Fax: +41 44 741 52 93 Email: [email protected] Web: www.flexdsl.ch Panel Description V84IS (Special Industrial Version with SFP interfaces) Connector LED RED GREEN AMBER OFF xDSL 1 (DSL No 1) 1 DSL not working DSL normal op…
-
9, FlexDSL Orion3 FlexDSL Telecommunications AG Steinackerstrassse 31 8902 Urdorf Switzerland Page 9/9 Tel: +41 44 741 52 90 Fax: +41 44 741 52 93 Email: [email protected] Web: www.flexdsl.ch Available Models Ordering Code Interfaces Power Supply Attention! FG-PAM-RAIL2N-2E1B/2Eth, V81 2xDSL 2xE1 2xETH 38-230VDC FG-PAM-RAIL2N-2E1B/2Eth-24V, V81 2x…
Recommended Instructions:
HD-SD-SP, FAT BOX, 785EPX — Stylus Photo Color Inkjet Printer, LFX23961SW — 22.6 cu. ft. Refrigerator
-
Z-Stick Gen 5 user guide.Modified on: Mon, 7 Jan, 2019 at 8:42 PMAeotec Z-Stick Gen5. Aeotec Z-Stick Gen5 has been crafted to power connected lighting using Z-Wave Plus (http://aeotec.com/z-wave-plus)as a self-powered Z-Wave® USB Adapter. It is powered by Aeotec’s Gen5 (http://aeotec.com/z-wave-gen5) technology. The technical specifications of Z-Stick Gen5 (https://aeotec.freshde …
Z-Stick Gen5 5
-
ENGLISH — 1 — CONTENTS 1. PRODUCT OVERVIEW ……………………………………………………………………………………. 3 2. WARNINGS ……………………………………………………………………………………………………. 4 3. INTRODUCTION ……………………………………………………………………….. …
F60 19
-
Warten Sie ungefähr zwei Minuten, bis das Modem eingeschaltet ist.Wenn das Modem über eine Batteriesicherung verfügt, entfernen Sie zuerst die Batterie, und setzen Sie sie dann wieder ein, bevor Sie Ihr Modem an den Strom anschließen.Lieferumfang:N300 Wireless Gigabit RouterJNR3000InstallationsanleitungNetzteilNetzwerkkabelSchritt 1:Ziehen Sie den Netzstecker, um das Modem auszuschalten …
JNR3000 2
-
USER MANUAL MODEL 1082 and1082/144 iDSL Modem with V.35 or X.21 Interface SALES OFFICE(301) 975-1000TECHNICAL SUPPORT(301) 975-1007 Part# 07M1082-UMDoc# 03315U2-001Rev. CRevised 11/2/06 An ISO-9001CertifiedCompanyCERTIFIED …
1082 32
Additional Information:
Popular Right Now:
Operating Impressions, Questions and Answers:
Table of Contents for FlexDSL ORION 3:
-
User Manual LTU Orion 3 90 4.6.5.4 <ENCODE [ON/OFF] [N]> Command This command activates or deactivates link-layer encryption on selected WAN channel [N]: CO_01_CM>ENCODE ON 1 ——————————————————————————— Encoding : WAN1 WAN2 WAN3 WAN4 ——————————————————————————— Destination : DSL1 DSL2 DSL3 DSL4 Key : set set set set Enabled : yes no no no ——————
-
User Manual LTU Orion 3 70 4.6.3.14 <M> Command After this command is entered the device jump to and displays the main menu. Master / Slave CO CP Unit acts as Master modem Unit acts as Slave modem NM dB Noise Margin G.826(ES) ES Number of seconds with errors. According to G.826 Status up down pre act act Link is UP Link is Down Link is preparing for activation Link is activating Alarm None Minor Major LOSW
-
User Manual LTU Orion 3 36 NOTE: RADIUS subsystem depends on Advanced Security settings. SECURE ON command has to be enabled before activating the RADIUS service The Orion3 modem acts as RADIUS client. It will request user authentication and authorisation from RADIUS server if operator will access command line or WEB interface of the device. NOTE: The current realisation of RADIUS protocol is designed for authentication and authorisation of the device operator. It is not intended for granting or disallowing an access from LAN ports
-
User Manual LTU Orion 3 21 Figure 3.5 Example of reservation While for a two SHDSL channels system in case of a failure the substitution of channels is “trivial”, in three and four SHDSL channels system different variants are possible. However, any system using the reservation mode follows a strict logic in channel substitution. The next table illustrates the logic of channel reservation with 2/3/4 SHDSL interfaces. The table for four DSL
-
User Manual LTU Orion 3 137 7. Select “Connect COM” in the “Action” menu. 8. Power on the device (activate). You may insert the unit to the subrack, minirack or UTTx housing. 9. Click “Yes” in the “Flashloader” window.
-
User Manual LTU Orion 3 13 Supported management features: • Local Craft Terminal (RS-232), Telnet, SNMP and WEB • Two levels of system users: administrator and user, protected with passwords Supported operating modes: • Multi-Service Operation, Point-to-Point, Point-to-Multipoint and Ring Applications 3.2 Description of Orion3 LTU Devices Orion3 subrack devices represent a printed circuit board with a front panel. The following LEDs and c
-
User Manual LTU Orion 3 150 Type – RJ-45 (female), 8 pins. Pin No. Description 1 E1 Input → CH1/2 Wire A 2 E1 Input → CH1/2 Wire B 3 NC (not used) 4 E1 Output → CH1/2 Wire A 5 E1 Output → CH1/2 Wire B 6 NC (not used) 7 NC (not used) 8 NC (not used) Please order FG-ADAPT-E1B/RJ45 to convert DB-15 connector to RJ-45 (female) connector. Attention, per DB-15 only one RJ-45 is possible.
-
User Manual LTU Orion 3 48 Table 3.14 Alarm LEDs of an Orion 3 device “A” – amber LED “R” – red LED “RB” – red LED blinking To display an urgent alarm has the highest priority (overwrite a non-urgent alarm). AIS-S A Receiving AIS on the E1 side BER-S A Excessive block error rate on the Е1 side LOOP1 A Loop is activated towards the Е1 equipment AIS-R A Receiving AIS on the E1 side of a remote device ECA SIF A Cable is not connected LOOP1 A
-
User Manual LTU Orion 3 3 VERSION CONTROL………………………………………………………………………………………………….. 8 SAFETY REGULATIONS ……………………………………………………………………………………………. 8 EU DIRECTIVE 2002/96/EC AND EN50419 …………………………………………………………………… 9 1 SELECTION GUIDE …………………….
-
User Manual LTU Orion 3 91 USER [username] [IP] [net] Set the IP range for user USERNAME. Net should be in range from 0 to 32. If no IP is set, no restrictions are applicable. USER [username] LOCAL Disable remote access for user USERNAME. This command is equal to USER [username] 0.0.0.0 32. USER [username] ALL Allow access from any IP address for user USERNAME. This command is equal to USER [username]
-
User Manual LTU Orion 3 136 5. Select “Select Device” in the “Setting” menu, then select “FG-PAM” and click “Ok”. 6. Select the “xxx.SSS” file and click “Open”.
-
User Manual LTU Orion 3 43 Figure 3.16 Example of distribution of time slots in an SHDSL frame at a line rate of 89×64 kbit/s in the mode when both E1 interfaces 1280 kbps of V.35 and both internal WAN1 and WAN2 ports are used for the termination device. 3.2.4 Test Loops The possibility to activate test loops on E1 or SHDSL line interface simplifies the device start-and- adjustment. Figure 3.17. Test loops Test loops can be activated for the Master and Slave devices as well as for the Regenerator. The LOOP1 ON/OFF N command is
-
User Manual LTU Orion 3 138 10. The loading progress will be displayed in the window “Flash Loader: Send Panel”. 11. If the downloading was successful, the following window will be displayed. 12. Click “Ok”. 13. Select “Disconnect COM” in the “Action” menu. 14. Power off the device being loaded and disconnect it from the Personal Computer. 15. Follow steps 1, 2, 7 – 15 to download the software into oth
Questions, Opinions and Exploitation Impressions:
You can ask a question, express your opinion or share our experience of FlexDSL ORION 3 device using right now.
Document’s Content and Additional Information | Share Manual |
---|---|
FlexDSL ORION 3 Technical description and operations manual
Pages Preview: Document Transcription:
See Details |
|
FlexDSL ORION 3 Technical description and operations manual
Pages Preview: Document Transcription:
See Details |