Orion 3 flexdsl руководство

SHDSL.bis

Up to 60Mbps

Ddd

E1 / Nx64 /Ethernet

FlexDSL Orion3

The FlexDSL Orion3 product family offers a broad range of products, which are based on the latest SHDSL.bis standards

(ITU-T G.991.2 & ETS TS 101 524) The FlexDSL Orion3 supports TC-PAM16/32 and the new TC-PAM4/8/64/128 line coding.

The FlexDSL Orion3 allows symmetrical data and voice transmission at speeds up to 15.2Mbps over a single pair of copper.

In addition, the FlexDSL Orion3 supports DSL channel bonding for up to 4 copper pairs in order to achieve speeds to

60.8Mbps. The SFP module (available on selected models) allows Ethernet data transmission over mixed Copper and Fiber

media.

FlexDSL Orion3 SHDSL.bis Extended modems can provide up to 2 E1 interfaces, which support framed and unframed

services (G.703/G.704). An integrated 2 or 4 port Ethernet layer 2 managed Switch with VLAN support (10/100BaseT)

ensures connectivity to IP services. Beside of E1 and Ethernet the additional Nx64 interfaces can be configured as V.35, V.36,

X.21, V.28, or RS232/RS485 interface (cable selectable).

Like all FlexDSL Orion products, the Orion3 SHDSL.bis modems family is based on industrial components, have extended

temperature range, advanced surge protection and produced in Switzerland.

Possible Applications

a)

b)

FlexDSL Telecommunications AG

Steinackerstrassse 31

8902 Urdorf

Switzerland

Features

Up to 15Mbps Data Transmission per Copper Pair

SHDSL and SHDSL.bis, TC-PAM16/32

Additional TC-PAM4/8/64/128 Available

1, 2 or 4 Copper Pairs Support

2 or 4 Port Ethernet Switch (10/100BaseT)

SFP connector for mixed Copper and Fiber applications

QoS, VLAN and RSTP Support

E1 (G.703/704, Balanced/Unbalanced)

Nx64 (V.35, V.36, X.21, V.28) and RS-232/485

Multi-Service Operation

Point-to-Point and Point-to-Multipoint Operation

Console Port, Telnet, Web, SNMP Management

24/48VDC Powered, Low Power Consumption

Included Primary Protection

Robust DIN-Rail Metal Enclosure

Industrial Temperature Range Available

a) Ethernet Transmission Point-to-Point

b) Ethernet Transmission Point-to-Multipoint

c) Ethernet Add/Drop over a Long Copper Line

d) Ethernet Transmission over Copper and Fiber

Page 1/9

c)

d)

Tel: +41 44 741 52 90

Fax: +41 44 741 52 93

Email: info@flexdsl.ch

Web: www.flexdsl.ch

  1. Manuals
  2. Brands
  3. FlexDSL Manuals
  4. Repeater
  5. ORION 3

Manuals and User Guides for FlexDSL ORION 3. We have 2 FlexDSL ORION 3 manuals available for free PDF download: Technical Description And Operations Manual

FlexDSL ORION 3 Technical Description And Operations Manual

FlexDSL ORION 3 Technical Description And Operations Manual (129 pages)

REPEATER DEVICES

Brand: FlexDSL
|
Category: Repeater
|
Size: 3.5 MB

Table of Contents
  • User Manual RR Orion

    2

  • Table of Contents

    3

  • Version Control

    7

  • Safety Regulations

    7

  • Eu Directive 2002/96/Ec and En50419

    7

  • 1 Selection Guide

    8

  • 2 Precaution

    9

  • 3 Technical Description

    10

    • General Information about Flexdsl Orion3

      10

    • Description of Orion3 RR (Repeater) Devices

      11

      • ABS Plastic & DIN-Rail Enclosure (IP 20/30)

        12

      • Polycarbonate Plastic & Die-Cast Aluminum Enclosure (IP 67/68)

        14

      • Remote Power Supply and Wetting Current

        18

        • Compatibility of Remote Power and Wetting Current Supply Modes

          18

        • Configuration of Remote Power

          19

      • Description of Orion3 Interfaces

        20

        • SHDSL Interface

          20

          • Master/Slave

            21

          • Multipair Mode

            21

          • Reservation Mode

            22

          • Automatic Configuration of a Link

            25

        • E1 Interface (G.703/704)

          27

        • Ethernet Interface

          27

        • MAC Filter

          30

          • MAC Filter Rules

            31

        • Rapid Spanning Tree Protocol

          31

      • An Integrated Switch of 64-Kbit/S Time Slots

        33

        • E1 Transmission Mode (Only E1 Time Slots)

          33

        • E1, Nx64/Rs-232/RS-485 and Ethernet Simultaneous Transmission Mode

          33

      • Test Loops

        34

        • Analogue Loop Back

          35

        • Performance Monitoring

          35

      • BERT Test

        36

    • Alarm Indication

      37

      • Leds

        37

      • Alarm Leds

        38

    • Management of Orion 3 Devices

      39

      • Management by Local Craft Terminal or MONITOR Interface (RS-232, USB )

        39

      • Management by Ethernet Interface

        40

        • Telnet

          40

        • Web

          40

        • Snmp

          43

        • Ssh

          45

        • Radius

          46

          • RADIUS Server Setup with Defined Vendor Specific Attributes

            47

          • Simplified RADIUS Server Setup

            48

          • Configuring User Access Rights

            49

        • Lldp

          51

  • 4 Programming Guide

    52

    • Command Structure

      52

    • Orion3 Software

      53

    • Configuration and Application Storage

      53

    • Groups of Commands Requiring Confirmation

      55

    • Command Syntax

      56

    • Commands

      57

      • Main Menu

        57

        • System Invitation

          57

    • General Commands

      58

      • H> Command

        58

      • APPLY [ALL/GROUP]> Command

        58

      • Connect N:1

        58

      • LINK [SN/00/FE]> Command

        58

      • LINKCLEAR> Command

        58

    • Performance Management Menu

      59

      • H> Command

        59

      • G826> Command

        59

      • RESETG826> Command

        60

      • NETSTAT [LAN/WAN]> Command

        60

      • NETERR [LAN/WAN]> Command

        61

      • RESETNETSTAT> Command

        61

      • M> Command

        61

    • Fault and Maintenance Management Menu

      62

      • H> Command

        62

      • NM> Command

        62

      • STATUS> Command

        63

      • STATUS ETH> Command

        63

      • STATUS LLDP> Command

        64

      • STATUS RADIUS> Command

        64

      • STATUS ENCODE> Command

        64

      • ALARM> Command

        65

      • AСO [GROUP ON/OFF])> Command

        66

      • MACTABLE> Command

        66

      • Lldp Stat [If/All]

        67

      • STARTAL [N]> Command

        68

      • Restart [N=1

        68

      • RESET> Command

        68

      • CONFIRM> Command

        68

      • BACKUP> Command

        68

      • RESTORE> Command

        68

      • DIFF N/R/S/B N/R/S/B> Command

        69

      • DUMP N/R/S/B> Command

        69

      • LOAD> Command

        70

      • TLM> Command

        70

      • SENSOR> Command

        70

      • Sensor [N=1

        70

      • LOG> and [LOG C] Command

        71

      • SOFTUPDATE> Command

        71

      • TFTP [CMD] [ARG1][ARG2]> Command

        71

      • SOFTCONFIRM> Command

        72

      • SOFTINFO> Command

        72

      • PING X.X.X.X> Command

        72

      • MODEMVIEW> Command

        72

      • SD SNAPSHOT> Command

        72

      • SD DIR> Command

        72

      • SD del [NAME]> Command

        73

      • Sd Save [N=0

        73

      • Sd Load [N=0

        73

      • SD BOOT [ON/OFF]> Command

        73

      • SD STATUS> Command

        73

    • Configuration Management Menu

      75

      • H> Command

        75

      • ENCODE [NRSB]> Command

        75

      • ENCODE KEY [N]> Command

        76

      • ENCODE [ON/OFF] [N]> Command

        76

      • SECURE ON/OFF> Command

        77

      • USERS> Command

        77

      • USER> Command

        77

      • PASSWORD {Users}> Command

        79

      • CONFIG /N/R/S/B> Command

        80

      • MASTER [1/2/AUTO] [N=1/2]> Command

        80

    • Ext On/Off [N = 1

      81

    • BASERATE [M/AUTO] [N=1/2]> Command

      81

    • PAM [16/32] [N]> or <PAM [4-128] [N]> Command

      81

    • ANNEX A/B/AB [N=1/2]> Command

      82

    • MULTIPAIR [2/OFF]> Command

      82

    • ID [String]> Command

      82

    • DEFAULT [0-3]> Command

      82

    • DEFAULT EVERYTHING> Command

      82

    • DEFAULT DESC> Command

      82

    • SERNUM> Command

      82

    • Wan [N/Auto/None] [K=1/2]

      82

    • GSCOMPAT ON/OFF> Command

      83

    • NMTHR> Command

      83

    • LATHR> Command

      83

    • PTMP [ADD/DEL] [IF]> Command

      83

    • PTMP SHOW> Command

      83

    • MODE N> Command

      83

    • LICENSE> Command

      83

    • LICENSE ADD> Command

      84

    • NET> Command

      84

    • H> Command

      84

    • NETCONFIG [N/R/S/B]> Command

      85

    • COSCONFIG> Command

      86

    • RSTP DEFAULT> Command

      87

    • Rstp [A

      88

    • Rstp [Iface] Prio [0

      88

    • Rstp [Iface] Pcost [Auto/1

      88

    • RSTP [A..E] [ON/OFF]> Command

      88

    • RSTP [IFACE] EDGE [ON/OFF]> Command

      89

    • RSTP CONF> Command

      89

    • RSTP STATE> Command

      89

    • RSTP DIAG> Command

      90

    • Pbvlan [If] [A

      91

    • MODE [IF] [ACC/TRUNK/MIX]> Command

      92

    • Vlan [If] [1

      92

    • Qos [If] [0

      92

    • ALLOW [IF] [VLAN List]> Command

      92

    • VID [1-8] ID> Command

      93

    • MACLIST SHOW> Command

      93

    • MACLIST [IF] ADD [MAC]> Command

      93

    • MACLIST [IF] del [MAC/N]> Command

      94

    • MACFILTER [LAN1-5] [ON/OFF]> Command

      94

    • MACRULE [LAN1-5] [RULE]> Command

      94

    • SETIP X.X.X.X> Command

      95

    • NETMASK X.X.X.X> Command

      95

    • GATEWAY X.X.X.X> Command

      95

    • MTU> Command

      95

    • WANIDLE [1/7E]> Command

      95

    • Ethsd [10H/10F/100H/100F/Auto/Off] [N=1

      95

    • FC [ON/OFF] [N1-4]> Command

      96

    • IRATE [Speed/Off] [N1-4]> Command

      96

    • ERATE [Speed/Off]> Command

      97

    • CRATE [Speed] [Cos] [WAN]> Command

      97

    • Cos [Qos/Vlan] [N] [0

      97

    • SNMPACL> Command

      97

    • SNMP [V1|V2C|V3] [ON|OFF]> Command

      98

    • TRAPIP [1/2] [IP/OFF]> Command

      98

    • TRAP [1/2] [V1/V2C]> Command

      98

    • TRAP [1/2] V3 [RO/RW]> Command

      98

    • COMMUNITY> Command

      98

    • SNMPSET [ON/OFF]> Command

      98

      • SNMP [RO|RW] NAME> Command

        98

      • SNMP [RO|RW] AUTH [MODE]> Command

        99

      • SNMP [RO|RW] PRIV [MODE]> Command

        99

      • SYSLOG [1/2] [IP/OFF]> Command

        99

      • LLDP [ON/OFF]> Command

        99

      • LLDP DEFAULT> Command

        100

      • LLDP [PARAM] [VALUE]> Command

        100

      • LLDP [RX/TX] [ON/OFF]> Command

        101

      • LLDP INT VLAN [ON/OFF]> Command

        101

      • LLDP CONFIG> Command

        101

      • SNTP [1/2] [IP/OFF]> Command

        101

      • SNTP TZ [+/-]HH:MM> Command

        101

      • DST> Command

        102

      • [Ssh|Telnet|Http|Https] [On/Off]

        104

      • Ssh Port [N]

        104

      • SSL [SHOW/DEL] [Options]

        105

      • Radius [1/2] Secret

        105

      • Radius [1/2] Test

        105

      • Radius [1/2] [Ip:p/Off]

        106

      • Radius Retries [0

        106

      • Radius Timeout [1

        106

      • STATUS RADIUS [N/R/S/B]> Command

        107

      • NETDEFAULT> Command

        107

  • 5 Software Download

    109

    • Software Download Via RS-232, USB Port (LCT) Using the Flash Loader Program

      109

    • Software Download Via RS-232, USB COM Port (LCT) Using Xmodem Protocol

      113

    • Software Download Via Ethernet (1K-Xmodem and Telnet)

      116

  • 6 Service Instructions

    117

    • General Requirements

      117

    • Evaluation of the Digital Channel Quality and Operation Parameters

      117

  • 7 Appendices

    119

    • Quick Installation Guide for Orion3 NTU & RR Devices

      119

      • Enter an Orion3 Device

        119

      • Configure an Orion3 NTU Device (Link)

        119

      • Configure an Orion3 RR Device (Repeater Between)

        121

      • Checking of Correct Working

        123

      • Problem with Orion3 Device

        123

    • Connector Description

      124

      • Ethernet Connector

        124

      • SHDSL Connector

        124

      • Monitor (LCT, Local Craft Terminal) Connector

        125

      • 48VDС Connector

        126

  • 8 Technical Specification

    127

    • Interfaces

      127

      • SHDSL Line Interface

        127

      • Monitor or Local Craft Terminal (RS-232) Interface

        127

      • Alarm at Local Craft Terminal (RS-232) Interface

        127

      • Monitor or Local Craft Terminal (USB) Interface

        127

      • Ethernet

        127

    • Power Supply

      128

    • Environment

      128

      • Climatic Conditions

        128

      • EMC and Safety Standards

        128

    • Physical Dimensions and Weight

      128

Advertisement

FlexDSL ORION 3 Technical Description And Operations Manual

FlexDSL ORION 3 Technical Description And Operations Manual (160 pages)

LTU DEVICES

Brand: FlexDSL
|
Category: Modem
|
Size: 4.82 MB

Table of Contents
  • User Manual LTU Orion

    2

  • Table of Contents

    3

  • Version Control

    8

  • Eu Directive 2002/96/Ec and En5041

    9

  • 1 Selection Guide

    10

  • 2 Precaution

    11

  • 3 Technical Description

    12

    • Description of Orion3 LTU Devices

      13

      • Remote Power Supply and Wetting Current

        14

      • Description of Orion3 Interfaces

        17

        • Multipair Mode

          18

        • Reservation Mode

          19

        • Automatic Configuration of a Link

          22

        • E1 Interface (G.703/704)

          24

        • Nx64, RS-232/RS-485 and G.703/E0 Interfaces

          26

          • Nx64 Clocking Modes

            27

          • Automatic V.54 Loops

            28

        • Ethernet Interface

          29

        • MAC Filter

          32

          • MAC Filter Rules

            33

          • IEEE 802.1X Device Settings

            34

        • Radius

          35

          • RADIUS Server Setup with Defined Vendor Specific Attributes

            36

          • Simplified RADIUS Server Setup

            38

          • RADIUS Server Setup with Defined Service-Type Attribute

            39

        • Lldp

          41

      • An Integrated Switch of 64-Kbit/S Time Slots

        42

      • Test Loops

        43

        • Analogue Loop Back

          44

      • BERT Test

        45

    • Alarm Indication

      46

      • Alarm Leds

        47

    • Management of Orion 3 Devices

      49

      • Management by Ethernet Interface

        50

        • Snmp

          54

  • 4 Programming Guide

    57

    • Orion3 Software

      59

    • Groups of Commands Requiring Confirmation

      61

    • Commands

      62

      • General Commands

        63

      • Performance Management Menu

        64

        • ALLG826 N> Command

          66

        • NETSTAT [LAN/WAN]> Command

          67

        • RESETNETSTAT> Command

          68

        • LINKALARM> Command

          69

        • M> Command

          70

      • Fault and Maintenance Management Menu

        71

        • NM> & <LINKNM> Command

          72

        • STATUS ETH> Command

          73

        • STATUS RADIUS> Command

          74

        • LOOP1 ON/OFF [N=1..4]> Command

          75

        • MACTABLE> Command

          77

        • Lldp Stat [If/All]

          78

        • STARTAL [N]> Command

          79

        • DIFF N/R/S/B N/R/S/B> Command

          80

        • LOAD> Command

          81

        • TLM S [N:[Rnn-Rkk]] [ABC]> Command

          82

        • LOG> and [LOG C] Command

          83

        • TFTP [CMD] [ARG1][ARG2]> Command

          84

        • SOFTINFO> Command

          85

        • SD SAVE [N=0..9]> Command

          86

        • H> Command

          87

      • Configuration Management Menu

        88

        • ENCODE [NRSB]> Command

          89

        • ENCODE [ON/OFF] [N]> Command

          90

        • PASSWORD {Users}> Command

          93

        • MASTER ON/OFF [N = 1..4]> Command

          95

        • BASERATE K/AUTO [N=1..4]> Command

          96

        • ANNEX A/B/AB [N=1..4]> Command

          97

        • G704 ON/OFF [N]> Command

          98

        • E1MODE [HDB3/AMI] [N]>, <E1MODE [SHORT/LONG] [N]> Commands

          99

        • GSCOMPAT ON/OFF> Command

          100

        • LICENSE> Command

          101

        • RSRATE [N]> Command

          104

        • IOIP {OPTION} [IF]> Command

          105

        • NET> Command

          107

        • NETCONFIG [N/R/S/B]> Command

          108

        • COSCONFIG [N/R/S/B]> Command

          110

        • RSTP DEFAULT> Command

          111

        • RSTP [A..E] HELLO [2..10]> Command

          112

        • Rstp [Iface] Ma [6..40]

          113

        • RSTP [IFACE] PCOST [AUTO/1..200000000]> Command

          114

        • RSTP STATE> Command

          115

        • RSTP DIAG> Command

          116

        • MODE [IF] [ACC/TRUNK/MIX]> Command

          117

        • QOS [IF] [0..7]> Command

          118

        • MACLIST [IF] ADD [MAC]> Command

          119

        • MACFILTER [LAN1-5] [ON/OFF]> Command

          120

        • SETIP X.X.X.X> Command

          121

        • FC [ON/OFF] [N1-4]> Command

          122

        • ERATE [Speed/Off]> Command

          123

        • COS [QOS/VLAN] [N] [0..3/OFF]> Command

          124

        • TRAP [1/2] [V1/V2C]> Command

          125

        • SNMP [RO|RW] PRIV [MODE]> Command

          126

        • LLDP [PARAM] [VALUE]> Command

          127

        • LLDP CONFIG> Command

          128

        • Ssh|Telnet|Http|Https] [On/Off]

          131

        • Radius [1/2] Secret

          132

        • Radius Retries [0..10]

          133

        • NETDEFAULT> Command

          134

      • Software Download

        135

      • Software Download Via RS-232 COM Port (LCT) Using Xmodem Protocol

        139

      • Software Download Via Ethernet (1K-Xmodem and Telnet)

        142

      • Service Instructions

        143

      • Appendices

        145

      • Checking of Correct Working

        148

      • Connector Description

        149

      • E1 75 Ohm Connector

        151

      • Monitor (LCT, Local Craft Terminal) Connector (ACU, Minirack, Uttx)

        156

      • Digital Input / Output Interface (4I4O) Connector

        157

      • Technical Specification

        158

      • Monitor or Local Craft Terminal (RS-232) Interface

        159

      • Environment

        160

Advertisement

Related Products

  • FlexDSL Orion3

  • FlexDSL ORION 2

  • FlexDSL ORION 2+

  • FlexDSL Orion2

FlexDSL Categories

Modem

Repeater

Industrial Equipment

More FlexDSL Manuals

Detail Specifications:

1301/1301100-orion3.pdf file (31 Mar 2023)

Accompanying Data:

FlexDSL Orion3 Modem PDF Manual  (Updated: Friday 31st of March 2023 10:22:57 AM)

Rating: 4.6 (rated by 25 users)

Compatible devices: 6511, Z288L, Unite II, BIPAC 7000, MiniFlex SHDSL, F8X14 Series, duoPlus 300WR, ORION 3.

Recommended Documentation:

Text Version of Manual 

(Ocr-Read Summary of Contents, UPD: 31 March 2023)

  • 1, FlexDSL Orion3 FlexDSL Telecommunications AG Steinackerstrassse 31 8902 Urdorf Switzerland Page 1/9 Tel: +41 44 741 52 90 Fax: +41 44 741 52 93 Email: [email protected] Web: www.flexdsl.ch Ddd The FlexDSL Orion3 product family offers a broad range of products, which are based on the latest SHDSL.bis standards (ITU-T G.991.2 &…

  • 2, FlexDSL Telecommunications AG Steinackerstrassse 31 8902 Urdorf Switzerland Page 2/9 Tel: +41 44 741 52 90 Fax: +41 44 741 52 93 Email: [email protected] Web: www.flexdsl.ch Quick Installation Guide Enter an Orion3 Device You can use the Monitor (Local Craft Terminal, RS-232) interface with Hyper Terminal (or any equal program) or you can address the device with T…

  • 3, FlexDSL Telecommunications AG Steinackerstrassse 31 8902 Urdorf Switzerland Page 3/9 Tel: +41 44 741 52 90 Fax: +41 44 741 52 93 Email: [email protected] Web: www.flexdsl.ch Enter in device 2 with the Monitor (LCT, RS-232 or USB) or Telnet interface. Type following commands Description 3 <> Go to Configuration Management (CM) <DEF…

  • 4, FlexDSL Orion3 FlexDSL Telecommunications AG Steinackerstrassse 31 8902 Urdorf Switzerland Page 4/9 Tel: +41 44 741 52 90 Fax: +41 44 741 52 93 Email: [email protected] Web: www.flexdsl.ch Connector Description SHDSL Technical Specification SHDSL Connector Specification Specification ITU-T G.991.2 G.shdsl and G.shdsl.bis Pin No Description Line…

  • 5, FlexDSL Telecommunications AG Steinackerstrassse 31 8902 Urdorf Switzerland Page 5/9 Tel: +41 44 741 52 90 Fax: +41 44 741 52 93 Email: [email protected] Web: www.flexdsl.ch Nx64 Interface DB-26H Connector Specification Specification V.35/V.36/X.21/V.28 Pin No V.35/36/28 X.21 Data Rate 1..128x64kbps (synchronous) for V.35/V.36/X.21 1 Mode Sel 2 1…

  • 6, FlexDSL Telecommunications AG Steinackerstrassse 31 8902 Urdorf Switzerland Page 6/9 Tel: +41 44 741 52 90 Fax: +41 44 741 52 93 Email: [email protected] Web: www.flexdsl.ch RS-232(V24)/RS-485 Interface DB-26H Connector Specification Specification RS-232/485 Pin No RS-232 RS-485 Data Rate 1200..256000 bps (asynchronous) 1 DTR Format RS-232/RS-485…

  • 7, FlexDSL Telecommunications AG Steinackerstrassse 31 8902 Urdorf Switzerland Page 7/9 Tel: +41 44 741 52 90 Fax: +41 44 741 52 93 Email: [email protected] Web: www.flexdsl.ch Panel Description Connector LED RED GREEN AMBER OFF xDSL 1 (DSL No 1) Left DSL not working DSL normal operation xDSL 1 (DSL No 3, only V84) Right…

  • 8, FlexDSL Telecommunications AG Steinackerstrassse 31 8902 Urdorf Switzerland Page 8/9 Tel: +41 44 741 52 90 Fax: +41 44 741 52 93 Email: [email protected] Web: www.flexdsl.ch Panel Description V84IS (Special Industrial Version with SFP interfaces) Connector LED RED GREEN AMBER OFF xDSL 1 (DSL No 1) 1 DSL not working DSL normal op…

  • 9, FlexDSL Orion3 FlexDSL Telecommunications AG Steinackerstrassse 31 8902 Urdorf Switzerland Page 9/9 Tel: +41 44 741 52 90 Fax: +41 44 741 52 93 Email: [email protected] Web: www.flexdsl.ch Available Models Ordering Code Interfaces Power Supply Attention! FG-PAM-RAIL2N-2E1B/2Eth, V81 2xDSL 2xE1 2xETH 38-230VDC FG-PAM-RAIL2N-2E1B/2Eth-24V, V81 2x…

Recommended Instructions:

HD-SD-SP, FAT BOX, 785EPX — Stylus Photo Color Inkjet Printer, LFX23961SW — 22.6 cu. ft. Refrigerator

  • Z-Stick Gen 5 user guide.Modified on: Mon, 7 Jan, 2019 at 8:42 PMAeotec Z-Stick Gen5. Aeotec Z-Stick Gen5 has been crafted to power connected lighting using Z-Wave Plus (http://aeotec.com/z-wave-plus)as a self-powered Z-Wave® USB Adapter. It is powered by Aeotec’s Gen5 (http://aeotec.com/z-wave-gen5) technology. The technical specifications of Z-Stick Gen5 (https://aeotec.freshde …

    Z-Stick Gen5 5

  • ENGLISH — 1 — CONTENTS 1. PRODUCT OVERVIEW ……………………………………………………………………………………. 3 2. WARNINGS ……………………………………………………………………………………………………. 4 3. INTRODUCTION ……………………………………………………………………….. …

    F60 19

  • Warten Sie ungefähr zwei Minuten, bis das Modem eingeschaltet ist.Wenn das Modem über eine Batteriesicherung verfügt, entfernen Sie zuerst die Batterie, und setzen Sie sie dann wieder ein, bevor Sie Ihr Modem an den Strom anschließen.Lieferumfang:N300 Wireless Gigabit RouterJNR3000InstallationsanleitungNetzteilNetzwerkkabelSchritt 1:Ziehen Sie den Netzstecker, um das Modem auszuschalten …

    JNR3000 2

  • USER MANUAL MODEL 1082 and1082/144 iDSL Modem with V.35 or X.21 Interface SALES OFFICE(301) 975-1000TECHNICAL SUPPORT(301) 975-1007 Part# 07M1082-UMDoc# 03315U2-001Rev. CRevised 11/2/06 An ISO-9001CertifiedCompanyCERTIFIED …

    1082 32

Additional Information:

Popular Right Now:
Operating Impressions, Questions and Answers:

Table of Contents for FlexDSL ORION 3:

  • User Manual LTU Orion 3 90 4.6.5.4 <ENCODE [ON/OFF] [N]> Command This command activates or deactivates link-layer encryption on selected WAN channel [N]: CO_01_CM>ENCODE ON 1 ——————————————————————————— Encoding : WAN1 WAN2 WAN3 WAN4 ——————————————————————————— Destination : DSL1 DSL2 DSL3 DSL4 Key : set set set set Enabled : yes no no no ——————

  • User Manual LTU Orion 3 70 4.6.3.14 <M> Command After this command is entered the device jump to and displays the main menu. Master / Slave CO CP Unit acts as Master modem Unit acts as Slave modem NM dB Noise Margin G.826(ES) ES Number of seconds with errors. According to G.826 Status up down pre act act Link is UP Link is Down Link is preparing for activation Link is activating Alarm None Minor Major LOSW

  • User Manual LTU Orion 3 36 NOTE: RADIUS subsystem depends on Advanced Security settings. SECURE ON command has to be enabled before activating the RADIUS service The Orion3 modem acts as RADIUS client. It will request user authentication and authorisation from RADIUS server if operator will access command line or WEB interface of the device. NOTE: The current realisation of RADIUS protocol is designed for authentication and authorisation of the device operator. It is not intended for granting or disallowing an access from LAN ports

  • User Manual LTU Orion 3 21 Figure 3.5 Example of reservation While for a two SHDSL channels system in case of a failure the substitution of channels is “trivial”, in three and four SHDSL channels system different variants are possible. However, any system using the reservation mode follows a strict logic in channel substitution. The next table illustrates the logic of channel reservation with 2/3/4 SHDSL interfaces. The table for four DSL

  • User Manual LTU Orion 3 137 7. Select “Connect COM” in the “Action” menu. 8. Power on the device (activate). You may insert the unit to the subrack, minirack or UTTx housing. 9. Click “Yes” in the “Flashloader” window.

  • User Manual LTU Orion 3 13 Supported management features: • Local Craft Terminal (RS-232), Telnet, SNMP and WEB • Two levels of system users: administrator and user, protected with passwords Supported operating modes: • Multi-Service Operation, Point-to-Point, Point-to-Multipoint and Ring Applications 3.2 Description of Orion3 LTU Devices Orion3 subrack devices represent a printed circuit board with a front panel. The following LEDs and c

  • User Manual LTU Orion 3 150 Type – RJ-45 (female), 8 pins. Pin No. Description 1 E1 Input → CH1/2 Wire A 2 E1 Input → CH1/2 Wire B 3 NC (not used) 4 E1 Output → CH1/2 Wire A 5 E1 Output → CH1/2 Wire B 6 NC (not used) 7 NC (not used) 8 NC (not used) Please order FG-ADAPT-E1B/RJ45 to convert DB-15 connector to RJ-45 (female) connector. Attention, per DB-15 only one RJ-45 is possible.

  • User Manual LTU Orion 3 48 Table 3.14 Alarm LEDs of an Orion 3 device “A” – amber LED “R” – red LED “RB” – red LED blinking To display an urgent alarm has the highest priority (overwrite a non-urgent alarm). AIS-S A Receiving AIS on the E1 side BER-S A Excessive block error rate on the Е1 side LOOP1 A Loop is activated towards the Е1 equipment AIS-R A Receiving AIS on the E1 side of a remote device ECA SIF A Cable is not connected LOOP1 A

  • User Manual LTU Orion 3 3 VERSION CONTROL………………………………………………………………………………………………….. 8 SAFETY REGULATIONS ……………………………………………………………………………………………. 8 EU DIRECTIVE 2002/96/EC AND EN50419 …………………………………………………………………… 9 1 SELECTION GUIDE …………………….

  • User Manual LTU Orion 3 91 USER [username] [IP] [net] Set the IP range for user USERNAME. Net should be in range from 0 to 32. If no IP is set, no restrictions are applicable. USER [username] LOCAL Disable remote access for user USERNAME. This command is equal to USER [username] 0.0.0.0 32. USER [username] ALL Allow access from any IP address for user USERNAME. This command is equal to USER [username]

  • User Manual LTU Orion 3 136 5. Select “Select Device” in the “Setting” menu, then select “FG-PAM” and click “Ok”. 6. Select the “xxx.SSS” file and click “Open”.

  • User Manual LTU Orion 3 43 Figure 3.16 Example of distribution of time slots in an SHDSL frame at a line rate of 89×64 kbit/s in the mode when both E1 interfaces 1280 kbps of V.35 and both internal WAN1 and WAN2 ports are used for the termination device. 3.2.4 Test Loops The possibility to activate test loops on E1 or SHDSL line interface simplifies the device start-and- adjustment. Figure 3.17. Test loops Test loops can be activated for the Master and Slave devices as well as for the Regenerator. The LOOP1 ON/OFF N command is

  • User Manual LTU Orion 3 138 10. The loading progress will be displayed in the window “Flash Loader: Send Panel”. 11. If the downloading was successful, the following window will be displayed. 12. Click “Ok”. 13. Select “Disconnect COM” in the “Action” menu. 14. Power off the device being loaded and disconnect it from the Personal Computer. 15. Follow steps 1, 2, 7 – 15 to download the software into oth

Questions, Opinions and Exploitation Impressions:

You can ask a question, express your opinion or share our experience of FlexDSL ORION 3 device using right now.

Document’s Content and Additional Information Share Manual

FlexDSL ORION 3 Technical description and operations manual

  • FlexDSL
  • Modem
  • Technical description and operations manual for FlexDSL ORION 3
  • flexdsl-orion-3-technical-description-and-operations-manual-160_manual.pdf
  • 160 |

Pages Preview:



Document Transcription:

  • User Manual LTU Orion 3 66 Option: С – update the table continuously. Digits 1, 2, 3 and 4 in the first row of the table indicate 1 st , 2 nd , 3 rd and 4 th E1 interfaces. CRC4 – Cyclic redundancy check indicate errored submultiframes recei …

  • User Manual LTU Orion 3 60 Figure 4.1 Operations of the configuration parameters after the restart Configuration changes, which are used instantly, are written into the running, startup and new configuration, and the device continues working acco …

  • User Manual LTU Orion 3 57 4 PROGRAMMING GUIDE 4.1 Command Structure Main Menu PM Performance management FMM Fault and maintenance management CM Configuration management G826 NM ENCODE G826 C LINKNM ENCODE KEY [N] G82 …

See Details
Download

FlexDSL ORION 3 Technical description and operations manual

  • FlexDSL
  • Repeater
  • Technical description and operations manual for FlexDSL ORION 3
  • flexdsl-orion-3-technical-description-and-operations-manual-129_manual.pdf
  • 129 |

Pages Preview:



Document Transcription:

  • User Manual RR Orion 3 64 4.6.4.5 <STATUS LLDP> Command The <STATUS LLDP> command shows LLDP neighbourhood. CX_06_FMM>STATUS LLDP MWAN1 neighbour: Port description: MWAN2 Management address: 192.168.1.26 Chas …

  • User Manual RR Orion 3 28 The number of E1 and SHDSL interfaces depends on the model of the Orion3 family. The choice of the interface (DSL or E1), which will be mapped to the corresponding WAN interface is performed by the <PAYLOA …

  • User Manual RR Orion 3 27 Figure 3.14 Automatic configuration 2x E1 and Ethernet are transmitted over two SHDSL link. 3.2.4.2 E1 Interface (G.703/704) This interface is not yet supported by repeaters. 3.2.4.3 Ethernet Interface The Ethernet …

See Details
Download

Понравилась статья? Поделить с друзьями:
  • Фритюрница мулинекс инструкция по применению uno m
  • Должностная инструкция начальника отдела по развитию производственной системы
  • Орвего фунгицид инструкция по применению на картофеле
  • Руководство для оперативников
  • Инструкция на русском языке для вакуумного упаковщика vacuum sealer