Панель bop 2 мануал

  1. Manuals
  2. Brands
  3. Siemens Manuals
  4. Control Panel
  5. SINAMICS BOP-2

Manuals and User Guides for Siemens SINAMICS BOP-2. We have 3 Siemens SINAMICS BOP-2 manuals available for free PDF download: Operating Instructions Manual

Siemens SINAMICS BOP-2: List of Available Documents

Note for Owners:

Guidesimo.com webproject is not a service center of Siemens trademark and does not carries out works for diagnosis and repair of faulty Siemens SINAMICS BOP-2 equipment. For quality services, please contact an official service center of Siemens company. On our website you can read and download documentation for your Siemens SINAMICS BOP-2 device for free and familiarize yourself with the technical specifications of device.

More Control Panel Devices:

  • Garmin 340

    P/N 11934-S01 1 of 10Cirrus Design Section 9SR20 SupplementsPilot’s Operating Handbook andFAA Approved Airplane Flight ManualSupplementforGarmin GMA 340 Audio SystemIncludes Optional XM Radio SystemWhen the Garmin GMA 340 Audio Panel and the optional XM RadioSystem are installed in the Cirrus Design SR20, this Supplement isapplicable and must be inserted in the Supplements Section (Section9) of …

    340 Stereo System, 10

  • Satel INT-TSG

    int-tsg_oi_en 05/15 Keypad INT-TSG Firmware version 1.03 INTEGRA / INTEGRA Plus Brief System User Manual SATEL sp. z o.o. • ul. Budowlanych 66 • 80-298 Gdańsk • POLAND tel. 58 320 94 00 www.satel.eu …

    INT-TSG Keypad, 20

  • Daktronics All Sport 5000

    All Sport 5000® Quick Reference Standard Keys for Timekeepers Start-Up — Turn the Power Switch in the back of the console, left side ON. — At the “RESUME GAME?” prompt, if the “PREV CODE” reads “4402”, press <YES> key. If not, press <NO> key and enter “4402” at the “SELECT CODE” prompt and press <ENTER>. Set Main Clock — The first press of the <SET MA …

    All Sport 5000 Controller, 2

  • Slant/Fin VICTORY VSPH SERIES

    RATINGS CHART – OIL BOILERSEUTECTIC EC-20 BOILER — WATER©Slant/Fin Corp. 2007SLANT/FIN CORPORATION, Greenvale, NY 11548 • Phone: (516) 484-2600FAX: (516) 484-5921 • In Canada: Slant/Fin LTD/LTEE, Mississauga, Ontariowww.slantfin.com®Model ComparisonType of Boiler EC-25 EC-26 EC-27 EC-28Maximum Inputs#2 Fuel Oil GPH 1.55 1.90 2.25 2.50#2 Fuel Oil MBTH 217 266 315 350Gross Outputs MBTH#2 Fue …

    VICTORY VSPH SERIES Boiler, 1

Recommended Documentation:

Download or browse on-line these Operating Instructions Manual for Siemens SINAMICS BOP-2 Control Panel.

Summary of Contents:

[Page 1] Siemens SINAMICS BOP-2

[Page 2] Siemens SINAMICS BOP-2

[Page 3] Siemens SINAMICS BOP-2

Basic Operator Panel 2 (BOP-2) ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ _____________…

[Page 4] Siemens SINAMICS BOP-2

Siemens AG Division Digital Factory Postfach 48 48 90026 NÜRNBERG GERMANY Document order number: (null) Ⓟ 03/2016 Subject to change Copyright © Siemens AG 2016. All rights reserved Legal information Warning notice…

[Page 5] Siemens SINAMICS BOP-2

Basic Operator Panel 2 (BOP-2) Operating Instructions, 02/2016, A5E37143404B AA 5 Table of contents 1 Changes in this manual ……………………………………………………………………………………………………

[Page 6] Siemens SINAMICS BOP-2

Table of contents Basic Operator Panel 2 (BOP-2) 6 Operating Instructions, 02/2016, A5E37143404B AA

[Page 7] Siemens SINAMICS BOP-2

Basic Operator Panel 2 (BOP-2) Operating Instructions, 02/2016, A5E37143404B AA 7 Changes in this manual 1 Important changes with respect to the Manual, Edition 02/2016 Listed below are all the changes that have been implemented in …

[Page 8] Siemens SINAMICS BOP-2

Changes in this manual Basic Operator Panel 2 (BOP-2) 8 Operating Instructions, 02/2016, A5E37143404B AA

[Page 9] Siemens SINAMICS BOP-2

Basic Operator Panel 2 (BOP-2) Operating Instructions, 02/2016, A5E37143404B AA 9 Fundamental safety instructions 2 2.1 General safety instructions WARNING Danger to life if the safety instructions and residual risks are not ob…

[Page 10] Siemens SINAMICS BOP-2

Fundamental safety instructions 2.2 Industrial security Basic Operator Panel 2 (BOP-2) 10 Operating Instructions, 02/2016, A5E37143404B AA 2.2 Industrial security Note Industrial security Siemens provides products and solutions w…

[Page 11] Siemens SINAMICS BOP-2

Basic Operator Panel 2 (BOP-2) Operating Instructions, 02/2016, A5E37143404B AA 11 Safety notes 3 Warnings and cautions DANGER Ensuring a safe and stable state During commissioning of the Inverter, it is essential to ensure…

[Page 12] Siemens SINAMICS BOP-2

Safety notes Basic Operator Panel 2 (BOP-2) 12 Operating Instructions, 02/2016, A5E37143404B AA

[Page 13] Siemens SINAMICS BOP-2

Basic Operator Panel 2 (BOP-2) Operating Instructions, 02/2016, A5E37143404B AA 13 Overview 4 Introduction The Basic Operator Panel 2 (BOP-2) has been designed to enhance the interface and communications capabilities of SINAMICS In…

[Page 14] Siemens SINAMICS BOP-2

Overview Basic Operator Panel 2 (BOP-2) 14 Operating Instructions, 02/2016, A5E37143404B AA Layout and functions The controls, display and connections of the BOP-2 are shown in the following figure: Image 4-1 Layout of the BOP-2 Tabl…

[Page 15] Siemens SINAMICS BOP-2

Overview Basic Operator Panel 2 (BOP-2) Operating Instructions, 02/2016, A5E37143404B AA 15 The specific functions of the keys are shown in the following table. Table 4- 2 Function of the BOP-2 controls Key Function The OK key has …

[Page 16] Siemens SINAMICS BOP-2

Overview Basic Operator Panel 2 (BOP-2) 16 Operating Instructions, 02/2016, A5E37143404B AA Note Reaction to change between HAND and AUTO mode When changing from HAND to AUTO mode the Inverter reacts in the following manner: • …

[Page 17] Siemens SINAMICS BOP-2

Overview Basic Operator Panel 2 (BOP-2) Operating Instructions, 02/2016, A5E37143404B AA 17 Menu structure The BOP-2 is a menu-driven device and has the following basic menu structure: Image 4-2 BOP-2 Basic menu structure

[Page 18] Siemens SINAMICS BOP-2

Overview Basic Operator Panel 2 (BOP-2) 18 Operating Instructions, 02/2016, A5E37143404B AA Note Menu structure and functionality The actual menu structure and functionality of the BOP -2 is influenced by the following factors: …

[Page 19] Siemens SINAMICS BOP-2

Basic Operator Panel 2 (BOP-2) Operating Instructions, 02/2016, A5E37143404B AA 19 Installation 5 Fitting the BOP-2 to the Control Unit Note BOP-2 power supply The BOP -2 has no internal power supply and derives its power di…

[Page 20] Siemens SINAMICS BOP-2

Installation Basic Operator Panel 2 (BOP-2) 20 Operating Instructions, 02/2016, A5E37143404B AA Initial startup After connection and power-up the BOP-2 automatically detects the type of Control Unit then attempts to establish communicati…

[Page 21] Siemens SINAMICS BOP-2

Basic Operator Panel 2 (BOP-2) Operating Instructions, 02/2016, A5E37143404B AA 21 Monitoring 6 Overview The Monitor menu allows the user to easily access a variety of screens which display the actual status of the system. The m…

[Page 22] Siemens SINAMICS BOP-2

Monitoring Basic Operator Panel 2 (BOP-2) 22 Operating Instructions, 02/2016, A5E37143404B AA The current output screen shows the actual Inverter current output to the motor. The frequency screen shows the actual frequency (in Hz…

[Page 23] Siemens SINAMICS BOP-2

Basic Operator Panel 2 (BOP-2) Operating Instructions, 02/2016, A5E37143404B AA 23 Control 7 Introduction The control menu allows the user to access the following functions of the Inverter: ● Setpoint ● Jog ● Reverse …

[Page 24] Siemens SINAMICS BOP-2

Control Basic Operator Panel 2 (BOP-2) 24 Operating Instructions, 02/2016, A5E37143404B AA Setpoint The setpoint value determines the speed at which the motor runs as a percentage of the nominal motor speed. It should be noted that this …

[Page 25] Siemens SINAMICS BOP-2

Control Basic Operator Panel 2 (BOP-2) Operating Instructions, 02/2016, A5E37143404B AA 25 Editing single digits It is possible to edit the individual digits of the setpoint screen. To enter the single digit editing mode, press until the…

[Page 26] Siemens SINAMICS BOP-2

Control Basic Operator Panel 2 (BOP-2) 26 Operating Instructions, 02/2016, A5E37143404B AA Note Reverse function When the JOG function is activate; pressing and simultaneously for more than 3 seconds toggles the REVERSE functio…

[Page 27] Siemens SINAMICS BOP-2

Basic Operator Panel 2 (BOP-2) Operating Instructions, 02/2016, A5E37143404B AA 27 Diagnostics 8 Diagnostic menu The Diagnostics menu allows the user to access the following function: ● Acknowledge all faults ● Faults ● …

[Page 28] Siemens SINAMICS BOP-2

Diagnostics Basic Operator Panel 2 (BOP-2) 28 Operating Instructions, 02/2016, A5E37143404B AA Image 8-2 Active faults and alarms sequence Note Dynamic fault screen If a fault occurs, the dynamic fault screen is automatically dis…

[Page 29] Siemens SINAMICS BOP-2

Diagnostics Basic Operator Panel 2 (BOP-2) Operating Instructions, 02/2016, A5E37143404B AA 29 Status The Status option displays the actual state of the control words and status words that are used to control and monitor various functions …

[Page 30] Siemens SINAMICS BOP-2

Diagnostics Basic Operator Panel 2 (BOP-2) 30 Operating Instructions, 02/2016, A5E37143404B AA The precise details of each bit of the status screens can be found in the parameter list under the associated parameter. The exact meaning of ea…

[Page 31] Siemens SINAMICS BOP-2

Diagnostics Basic Operator Panel 2 (BOP-2) Operating Instructions, 02/2016, A5E37143404B AA 31 Description Associated parameter Screen example Status Word 2 (lower bits) The screen displays the lower eight bits of Status Word 2. The …

[Page 32] Siemens SINAMICS BOP-2

Diagnostics Basic Operator Panel 2 (BOP-2) 32 Operating Instructions, 02/2016, A5E37143404B AA

[Page 33] Siemens SINAMICS BOP-2

Basic Operator Panel 2 (BOP-2) Operating Instructions, 02/2016, A5E37143404B AA 33 Parameters 9 Parameter menu The Parameter menu allows access to view and change the parameters of the Inverter. There are two filters available to a…

[Page 34] Siemens SINAMICS BOP-2

Parameters Basic Operator Panel 2 (BOP-2) 34 Operating Instructions, 02/2016, A5E37143404B AA Image 9-1 Selecting standard or export parameter filters Editing the parameters There are two methods to edit and modify parameters, these a…

[Page 35] Siemens SINAMICS BOP-2

Parameters Basic Operator Panel 2 (BOP-2) Operating Instructions, 02/2016, A5E37143404B AA 35 Image 9-2 Editing parameters (single digit method) The scrolling editing is accomplished by scrolling through to the parameters until the requir…

[Page 36] Siemens SINAMICS BOP-2

Parameters Basic Operator Panel 2 (BOP-2) 36 Operating Instructions, 02/2016, A5E37143404B AA Image 9-3 Editing parameters (scrolling method)

[Page 37] Siemens SINAMICS BOP-2

Basic Operator Panel 2 (BOP-2) Operating Instructions, 02/2016, A5E37143404B AA 37 Setup 10 Setup menu The setup menu is a fixed sequence of screens that allow the user to perform the standard commissioning of the Inverter. Once a…

[Page 38] Siemens SINAMICS BOP-2

Setup Basic Operator Panel 2 (BOP-2) 38 Operating Instructions, 02/2016, A5E37143404B AA Image 10-1 Motor Plate Information, 1.5 kW The basic commissioning procedure is shown in the following figures. WARNING Failure of the comm…

[Page 39] Siemens SINAMICS BOP-2

Setup Basic Operator Panel 2 (BOP-2) Operating Instructions, 02/2016, A5E37143404B AA 39 Image 10-2 Standard commissioning Part 1

[Page 40] Siemens SINAMICS BOP-2

Setup Basic Operator Panel 2 (BOP-2) 40 Operating Instructions, 02/2016, A5E37143404B AA Image 10-3 Standard commissioning Part 2

[Page 41] Siemens SINAMICS BOP-2

Setup Basic Operator Panel 2 (BOP-2) Operating Instructions, 02/2016, A5E37143404B AA 41 Image 10-4 Standard commissioning Part 3

[Page 42] Siemens SINAMICS BOP-2

Setup Basic Operator Panel 2 (BOP-2) 42 Operating Instructions, 02/2016, A5E37143404B AA

[Page 43] Siemens SINAMICS BOP-2

Basic Operator Panel 2 (BOP-2) Operating Instructions, 02/2016, A5E37143404B AA 43 Extras 11 Extras menu The extras menu allows the user to perform the following functions: ● DRVRESET — reset the Inverter to the factory default …

[Page 44] Siemens SINAMICS BOP-2

Extras Basic Operator Panel 2 (BOP-2) 44 Operating Instructions, 02/2016, A5E37143404B AA RAM ⇒ ROM This functions allows the data stored in the Inverter’s RAM to be saved to the Inverter’s ROM. The data is stored permanently…

[Page 45] Siemens SINAMICS BOP-2

Extras Basic Operator Panel 2 (BOP-2) Operating Instructions, 02/2016, A5E37143404B AA 45 From BOP This function writes parameter data stored in the BOP-2 memory to the Inverter memory. The symbol denotes where the screen automatically d…

[Page 46] Siemens SINAMICS BOP-2

Extras Basic Operator Panel 2 (BOP-2) 46 Operating Instructions, 02/2016, A5E37143404B AA Image 11-5 Extras — writing data to the memory card

[Page 47] Siemens SINAMICS BOP-2

Extras Basic Operator Panel 2 (BOP-2) Operating Instructions, 02/2016, A5E37143404B AA 47 From card This function reads parameter data from the memory card in the Control Unit to the Inverter’s memory. During the upload process, the …

[Page 48] Siemens SINAMICS BOP-2

Extras Basic Operator Panel 2 (BOP-2) 48 Operating Instructions, 02/2016, A5E37143404B AA

[Page 49] Siemens SINAMICS BOP-2

Basic Operator Panel 2 (BOP-2) Operating Instructions, 02/2016, A5E37143404B AA 49 Technical data 12 BOP-2 specifications Table 12- 1 BOP-2 specifications Feature Description Protection Depending upon the Control Unit IP rat…

[Page 50] Siemens SINAMICS BOP-2

Technical data Basic Operator Panel 2 (BOP-2) 50 Operating Instructions, 02/2016, A5E37143404B AA

[Page 51] Siemens SINAMICS BOP-2

Basic Operator Panel 2 (BOP-2) Operating Instructions, 02/2016, A5E37143404B AA 51 Index A Acknowledge faults, 27 Active faults and alarms, 27 C Control, 23 Hand mode, 23 jog, 25 Jog, 23 reverse, 23, 26 setpoint, 23, 24 D…

[Page 52] Siemens SINAMICS BOP-2

Index Basic Operator Panel 2 (BOP-2) 52 Operating Instructions, 02/2016, A5E37143404B AA frequency, 22 output current, 22 overview, 21 RPM, 22 voltage and current, 22 voltage and RPM, 22 voltage output, 21 N Net weight, 49 O Ope…

[Page 53] Siemens SINAMICS BOP-2

[Page 54] Siemens SINAMICS BOP-2

Table of Contents for Siemens SINAMICS BOP-2:

  • Installation Basic Operator Panel 2 (BOP-2) 16 Operating Instructions, 2010-03-01, A5E02778927A AB Initial startup Once the BOP-2 is fitted and powered-up it will automatically detect the type of Control Unit to which it has been fitted and attempt to automatically establish communications. On startup the BOP-2 will display the company name and the class of Operator Panel. SIEM ENS BOP-2 MONITORING MONITORING PAR AMET ER PAR AMET ER SETUP SETUP EXTRAS EXTRAS CONTROL CONTROL DI

  • Monitoring Basic Operator Panel 2 (BOP-2) 18 Operating Instructions, 2010-03-01, A5E02778927A AB The current output screen shows the actual Inverter current output to the motor. CURR OUT 10.0 MONITORING MONITORING PAR AMET ER PAR AMET ER SETUP SETUP EXTRAS EXTRAS CONTROL CONTROL DIAGNOS TIC S DIAGNOSTICS This screen shows the actual frequency (in Hz) at which the motor is running. FREQ 0.0 MONITORING MONITO

  • Parameters Basic Operator Panel 2 (BOP-2) Operating Instructions, 2010-03-01, A5E02778927A AB 31 Editing parameters (single digit) 1. Press and hold until the parameter number flashes. 2. Using the and keys to modify the first digit value. 3. Press to accept the modified value. 4. The next digit in the sequence will start flashing. 5. Press to accept the modified value. 6. The next digit in the sequence will start flashing. 7. Continue the sequence until all digits have been modified to the required number.

  • Änderungen vorbehalten © Siemens AG 2009 Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG DEUTSCHLAND http://support.automation.siemens.com

  • Table of contents Basic Operator Panel 2 (BOP-2) 6 Operating Instructions, 2010-03-01, A5E02778927A AB

  • Basic Operator Panel 2 (BOP-2) Operating Instructions, 2010-03-01, A5E02778927A AB 33 Setup 8 Setup menu The setup menu is a fixed sequence of screens that allow the user to perform the basic commissioning of the Inverter. Once a parameter value has been modified, there is no possibility to cancel the basic commissioning process. In this case, the basic commissioning process must be completed. If no parameter value has bee

  • Overview Basic Operator Panel 2 (BOP-2) Operating Instructions, 2010-03-01, A5E02778927A AB 11 Table 2- 2 Function of the BOP-2 controls Key Function The OK key has the following functions: • When navigating through the menus, pressing the OK key confirms selection of a menu item. • When working with parameters, pressing the OK key allows the parameter to be modified. Pressing the OK key again will confirm the entered value and return you to the previous screen. • In the faults screen it is

  • Control Basic Operator Panel 2 (BOP-2) 20 Operating Instructions, 2010-03-01, A5E02778927A AB Setpoint The setpoint value determines the speed at which the motor runs as a percentage of the nominal motor speed. It should be noted that this setpoint setting is only valid while HAND mode is selected. When the Inverter is set back to AUTO mode, the setpoint previously used in AUTO mode becomes the valid setpoint. Note T

  • Basic Operator Panel 2 (BOP-2) Operating Instructions, 2010-03-01, A5E02778927A AB 17 Monitoring 4 Overview The Monitor menu allows the user to easily access a variety of screens which display the actual status of the Inverter/motor system. The menu is selected by using the and keys to move the menu bar to the required menu. Pressing will confirm the selection and display the top level menu. MONITOR MONITORING MONITORING PAR AMET ER PAR AMET ER SETUP SETUP EXTRAS EXTRAS CONTROL CO

  • Basic Operator Panel 2 (BOP-2) Operating Instructions, 2010-03-01, A5E02778927A AB 5 Table of contents 1 Safety notes…………………………………………………………………………………………………………………………….. 7 2 Overview…………………………………………………………………………………

  • Parameters Basic Operator Panel 2 (BOP-2) 32 Operating Instructions, 2010-03-01, A5E02778927A AB Editing parameters (scrolling) 1. Using the or keys to scroll to the required parameter number. 2. Press to select the parameter. 3. The parameter value will start flashing. 4. Using the or keys to change the parameter value. 5. Pres

  • Extras Basic Operator Panel 2 (BOP-2) 42 Operating Instructions, 2010-03-01, A5E02778927A AB RAM ─> ROM The RAM ─> ROM function allows the data stored on the Inverters RAM to be saved to the Inverters ROM. The data is stored permanently in the ROM until it is overwritten by another RAM to ROM command. 1. Using the and keys select the «RAM ─> ROM» function. 2. Press to confirm selection. 3. Press to active the data transfer. 4. Press to cancel the data transfer. 5. During t

  • SINAMICS SINAMICS Basic Operator Panel 2 (BOP-2) Operating Instructions Edition 03/2010 2010-03-01 A5E02778927A AB Safety notes 1 Overview 2 Installation 3 Monitoring 4 Control 5 Diagnostics 6 Parameters 7 Setup 8 Extras 9 Technical data 10

  • Basic Operator Panel 2 (BOP-2) Operating Instructions, 2010-03-01, A5E02778927A AB 19 Control 5 Introduction The control menu allows the user to access the following functions of the Inverter: ● Setpoint ● Jog ● Reverse The menu is selected by using the and keys to move the menu bar to the required menu. Pressing will confirm the selection and display the top level menu. CONTROL MONITORINGMONITORING PAR AMETERPAR AMETER SETUPSETUP EXTRASEXTRAS CONTROLCONTROL DIA GNO ST ICSDIAGNOSTIC

Questions, Opinions and Exploitation Impressions:

You can ask a question, express your opinion or share our experience of Siemens SINAMICS BOP-2 device using right now.

Document’s Content and Additional Information Share Manual

Siemens SINAMICS BOP-2 Operating instructions manual

  • Siemens
  • Control Panel
  • Operating instructions manual for Siemens SINAMICS BOP-2
  • siemens-sinamics-bop-2-operating-instructions-manual-54_manual.pdf
  • 54 |

Pages Preview:



Document Transcription:

  • Siemens AG Division Digital Factory Postfach 48 48 90026 NÜRNBERG GERMANY Document order number: (null) Ⓟ 03/2016 Subject to change Copyright © Siemens AG 2016. All rights reserved Legal information Warning notice system …

  • Basic Operator Panel 2 (BOP-2) Operating Instructions, 02/2016, A5E37143404B AA 49 Technical data 12 BOP-2 specifications Table 12- 1 BOP-2 specifications Feature Description Protection Depending upon the Control Unit IP rating to a m …

  • Installation Basic Operator Panel 2 (BOP-2) 20 Operating Instructions, 02/2016, A5E37143404B AA Initial startup After connection and power-up the BOP-2 automatically detects the type of Control Unit then attempts to establish communications. On …

See Details
Download

Siemens SINAMICS BOP-2 Operating instructions manual

  • Siemens
  • Control Panel
  • Operating instructions manual for Siemens SINAMICS BOP-2
  • siemens-sinamics-bop-2-operating-instructions-manual-36_manual.pdf
  • 36 |

Pages Preview:



Document Transcription:

  • Commissioning 3.3 The most important parameters at a glance Frequency converters with Control Units CU230P-2; CU240B-2; CU240E-2 30 Getting Started, 01/2011, A5E02792536C AB 3.3 The most important parameters at a glance Table 3- 2 Defining the inte …

  • Installation 2.2 Selecting the interface assignment Frequency converters with Control Units CU230P-2; CU240B-2; CU240E-2 Getting Started, 01/2011, A5E02792536C AB 25 212)) ([WHUQDOIDXOW $FNQRZOHGJH 023XS 023GRZQ 212)) ([WHUQDOI …

  • Installation 2.1 Interfaces of the Control Units Frequency converters with Control Units CU230P-2; CU240B-2; CU240E-2 20 Getting Started, 01/2011, A5E02792536C AB 2.1.5 Terminal strips on CU240E-2 Control Units     ([SODQDWLRQ7HUPLQDOV � …

See Details
Download

Siemens SINAMICS BOP-2 Operating instructions manual

  • Siemens
  • Control Panel
  • Operating instructions manual for Siemens SINAMICS BOP-2
  • siemens-sinamics-bop-2-operating-instructions-manual-48_manual.pdf
  • 48 |

Pages Preview:



Document Transcription:

  • Safety notes Basic Operator Panel 2 (BOP-2) 8 Operating Instructions, 2010-03-01, A5E02778927A AB

  • Setup Basic Operator Panel 2 (BOP-2) Operating Instructions, 2010-03-01, A5E02778927A AB 37 MOT POW 307P MONITORING MONITORING PAR AMET ER PAR AMET ER SETUP SETUP EXTRAS EXTRAS CONTROL CONTROL DIAGNOS TIC S DIAGNOSTICS Motor power Sets …

  • Extras Basic Operator Panel 2 (BOP-2) 44 Operating Instructions, 2010-03-01, A5E02778927A AB From BOP Writes parameter data from the BOP-2 to the Inverter memory. 1. Using the and keys select the «FROM BOP» function. 2. Press …