Promag p100 руководство по эксплуатации

Detail Specifications:

2284/2284653-proline_promag_p_100.pdf file (29 Apr 2023)

Accompanying Data:

Endress+Hauser Proline Promag P 100 Measuring Instruments PDF Operating Instructions Manual (Updated: Saturday 29th of April 2023 10:57:53 AM)

Rating: 4.9 (rated by 42 users)

Compatible devices: Cerabar M PMP51, Deltabar S PMD70, Dosimag, Proline Prosonic Flow 92F, Proline Promag L 400, Proline Prosonic Flow
90U, Prosonic S FMU95 PROFIBUS DP, Proline Prosonic Flow 91W.

Recommended Documentation:

Text Version of Operating Instructions Manual

(Ocr-Read Summary of Contents, UPD: 29 April 2023)

  • 36, Operation options Proline Promag P 100 36 Endress+Hauser Device tag Webserv.language English Ent. access code Access stat.tool Maintenance 12 OK A0017362 1 Device tag (→  42) 2 Picture of device 8.2.4 Logging on Access code 0000 (factory setting); can be changed by customer (→  43) 8.2.5 User interface 2 4 6 5 1 32 4 6 5 1 32 4 6 5 1 32 4 6 5 1 32 4 6 5 1 3 A0017757-EN 1 2 3…

  • 43, Endress+Hauser Proline Promag P 100 Proline Promag P 100 Commissioning Endress+Hauser 43 Navigation «Setup» menu → Device tag Parameter overview with brief description Parameters Description User entry Factory setting Device tag Enter tag for measuring point. Max. 32 characters, such as letters, numbers or special characters (e.g. @, %, /). Promag 10.6 Protecting settings from unauthorized access The following op…

  • 16, Installation Proline Promag P 100 16 Endress+Hauser A A 1 2 3 2 A0016260  5 Horizontal orientation 1 EPD electrode for empty pipe detection 2 Measuring electrodes for signal detection 3 Reference electrode for potential equalization Inlet and outlet runs 5 × DN³ ³ 2 × DN A0016275 For the dimensions and installation lengths of the device, see the «Technical Information&quo…

  • 30, Endress+Hauser Proline Promag P 100 Electrical connection Proline Promag P 100 30 Endress+Hauser 1. Set the desired IP address using the corresponding DIP switches on the I/O electronics module.  Hardware addressing with the configured IP address is enabled after 10 s. 2. Disable software addressing via DIP switch 8 (OFF). PROFIBUS DP The address must always be configured for a PROFIBUS DP/PA device. The valid addre…

  • 8, Product description Proline Promag P 100 8 Endress+Hauser 3 Product description 3.1 Product design 3.1.1 Device version with HART, Modbus RS485 and PROFIBUS DP communication types 2 3 4 1 A0017609  1 Important components of a measuring device 1 Transmitter housing cover 2 Main electronics module 3 Transmitter housing 4 Sensor

  • 27, Endress+Hauser Proline Promag P 100 Proline Promag P 100 Electrical connection Endress+Hauser 27 Connection examples for standard situations Metal, grounded pipe A0016315  9 Potential equalization via measuring tube Connection example in special situations Unlined and ungrounded metal pipe This connection method also applies in situations where: • The customary potential equalization is not use…

  • 24, Electrical connection Proline Promag P 100 24 Endress+Hauser Modbus RS485, non-hazardous area and Zone 2/Div. 2 (on the device side) 3 2 4 1 5 A0016811 Pin Assignment Coding Plug/socket 1 B Socket 2 A Modbus RS485 3 4 B Modbus RS485 5 Grounding/shielding EtherNet/IP EtherNet/IP (on the device side) 3 2 4 1 A0016812 Pin Assignment Coding Plug/socket 1 + Tx D Socket 2 + Rx 3 — Tx 4 — …

  • 1, Products Solutions Services Brief Operating Instructions Proline Promag P 100 Electromagnetic flowmeter These Instructions are Brief Operating Instructions; they do not replace the Operating Instructions included in the scope of supply. For detailed information, refer to the Operating Instructions and other documentation on the CD-ROM provided or visit «www.endress.com/deviceviewer». KA…

  • 12, Storage and transport Proline Promag P 100 12 Endress+Hauser 5 Storage and transport 5.1 Storage conditions Observe the following notes for storage: • Store in original packaging. • Do not remove protective covers or protective caps installed on process connections. • Protect from direct sunlight. • Select a storage location where moisture cannot c…

Recommended Instructions:

FP72GS, SO-01E, K 328, LC-HDT10

  • DDräger Pac® 3500/5500 CO, H2S, O2enInstructions for Use2svBruksanvisning62bg  122deGebrauchsanweisung8etKasutamisjuhised68roInstrucfliuni de utilizare128frNotice d’utilisation8lvLietošanas instrukcija74huHasználati útmutató134esInstrucciones de uso14ltNaudojimo vadovas80el� …

    Pac 3500 19

  • °C / °F MAX/MIN ON/OFF37.1%26.5C°COMFORTINDTH880Temperature & Humidity MonitorCopyright © 2017 Kane USA Inc. All Rights Reserved.DISPOSAL Caution: This symbol indicates that equipment and its accessories shall be subject to separate collection and correct disposal.CLEANINGPeriodically clean your meters’ case using a damp cloth. DO NOT use abrasive, flammable liquids …

    DTH880 2

  • Agilent Technologies54600-Series OscilloscopesData SheetMultiple configurations to meet your needsIf you work with both analog and digital components, AgilentTechnologies 54600-Series oscilloscopes can help you easilysee more of what’s going on inyour designs. The unique 2 +16-channel mixed signal oscillo-scope (MSO) models and the tra-ditional 2- and 4-channel modelsare …

    54600-Series 24

  • (217) 352-9330 | [email protected] | artisantg.com-~ ARTISAN® ~I TECHNOLOGY GROUP Your definitive source for quality pre-owned equipment. Artisan Technology Group Full-service, independent repair center with experienced engineers and technicians on staff. We buy your excess, underutilized, and idle equipment along with credit for buybacks and trade-ins. Custom engineering so your equi …

    LiQuilaz-S Series 47

Additional Information:

Popular Right Now:
Operating Impressions, Questions and Answers:

Endress+Hauser Manuals and Guides:

The main types of Endress+Hauser Proline Promag P 100 instructions: user guide — rules of useing and characteristics, service manual — repair, diagnostics, maintenance, operation manual — description of the main functions of Endress+Hauser Proline Promag P 100 equipment, etc.

Most of the instructions, that you can see on the site are uploaded by our users. If you have available a manual or document for Endress+Hauser Proline Promag P 100, which is currently not on the site or present in a different language version, we ask you to upload your document on website, using the «uploading form» available to all registered users.

Характеристики и спецификации
Безопасность изделия CE, C-Tick
Входные сигналы Нет
Выходные сигналы 4…20 мА HART (активный), Импульсный/частотный/релейный выход (пассивный)
Гигиенические сертификаты и нормативы Сертификат на использование в питьевой воде: ACS, NSF 61
Диапазон измерения 4 дм³/мин…9600 м³/ч (1…44000 гал/мин)
Диапазон номинальных диаметров DN 15 … 600 (½… 24″)
Диапазон окружающей температуры Материал фланца – углеродистая сталь: –10…+60 °C (+14…+140 °F), Материал фланца – нержавеющая сталь: -40….+60 °C (-40 … +140 °F)
Диапазон температур продукта Материал футеровки PFA: –20…+150 °C (–4…+302 °F), Материал футеровки PFA высокотемпературное исполнение: –20…+180 °C (–4…+356 °F), Материал футеровки PTFE: -40…+130 °C (-40…+266 °F)
Дисплей/Настройка Доступна установка 4-строчного дисплея с подсветкой (без локального управления), Возможна настройка посредством веб-браузера и управляющего ПО
Другие сертификаты и нормативы
Заголовок для продукта Расходомер для самых высоких рабочих температур со сверхкомпактным преобразователем, Используется в химических и технологических процессах с коррозийными жидкостями и при высоких рабочих температурах.
Измеряемые параметры Объемный расход, электропроводность, массовый расход, скорректированный объемный расход, скорректированная электропроводность
Источник питания 20…30 В пост. тока
Макс. погрешность измерения Объемный расход (стандартное исполнение): ±0.5 % ИЗМ± 1 мм/с (0.04 дюйма/с), Объемный расход (опция): ±0.2 % ИЗМ ± 2 мм/с (0.08 дюйма/с)
Макс. рабочее давление PN 40, класс 300, 20K
Материал корпуса преобразователя AlSi10Mg, с покрытием
Материал корпуса сенсора DN 15 … 300 (½… 12″) AlSi10Mg с покрытием, DN 350…600 (14…24″): Углеродистая сталь с защитным лаком
Метрологические нормативы и сертификаты Произведена калибровка на сертифицированном калибровочном оборудовании (соответствует ISO/IEC 17025), Технология Heartbeat соответствует требованиям к прослеживаемой верификации согласно ISO 9001:2015 – Раздел 7.1.5.2 a
Морские сертификаты и нормативы ABS, BV, LR, DNV GL, BV
Особенности преобразователя Компактный преобразователь – полная функциональность при малых размерах, Быстрая настройка и локальное управление без дополнительного программного и аппаратного обеспечения – встроенный веб-сервер, Встроенная проверка – технология Heartbeat Technology™, Прочный сверхкомпактный корпус преобразователя.
Принцип измерения Электромагнитные расходомеры
Сертификаты и нормативы по давлению PED, CRN
Сертификаты на взрывозащиту ATEX, IECEx, cCSAus, INMETRO
Сертификаты на материалы Сертификат на материал 3.1
Смачиваемые материалы Футеровка: PFA, PTFEЭлектроды: 1.4435 (316L), Alloy C22, 2.4602 (UNS N06022), тантал, платина, титанDuplex 1.4462 (UNS S31803)
Степень защиты IP66/67, защитная оболочка типа 4X
Функции датчика Универсальная применимость – широкое разнообразие смачиваемых материалов, Энергосберегающее измерение расхода – отсутствует потеря давления благодаря сужению поперечного сечения, Нет подвижных частей техническое обслуживание не требуется, Номинальный диаметр до DN 600 (24″), Имеются все распространенные сертификаты по взрывозащищенному исполнению.
Цифровая связь HART, PROFIBUS DP, Modbus RS485, EtherNet/IP, PROFINET