Promag p300 руководство по эксплуатации

  • Contents

  • Table of Contents

  • Bookmarks

Available languages

  • EN

  • DE

Quick Links

EA001164D/06/A2/01.16

71327830

Products

Alteration Instructions

Promag 300, 500

Promass 300, 500

Activate the Software Licence Code

These Instructions are Alteration Instructions; they

do not replace the Operating Instructions included in

the scope of supply.

For detailed information, refer to the Operating

Instructions and other documentation or visit

«www.endress.com/deviceviewer».

Solutions

Services

loading

Summary of Contents for Endress+Hauser Promag 300

KA01290D/06/EN/02.17

71380238

Products

Solutions

Services

Brief Operating Instructions

Proline Promag P

Electromagnetic sensor

These instructions are Brief Operating Instructions; they are not a substitute for the Operating Instructions pertaining to the device.

Sensor Brief Operating Instructions

Contain information about the sensor. Transmitter Brief Operating Instructions → 3.

Endress+Hauser P 300 Operating Manual

Proline Promag P

ORDER CODE:

XXXXX-XXXXXX

1.

SER. NO.:

XXXXXXXXXXXX

EXT. ORD. CD.:

XXX.XXXX.XX

Serial number

2.

www.endress.com/deviceviewer

Endress+Hauser

Operations App

3.

A0023555

Proline Promag P

Brief Operating Instructions for the device

Brief Operating Instructions for the device

The device consists of a transmitter and a sensor.

The process of commissioning these two components is described in two separate manuals:

Sensor Brief Operating Instructions

Transmitter Brief Operating Instructions

Please refer to both Brief Operating Instructions when commissioning the device as the contents of the manuals complement one another:

Sensor Brief Operating Instructions

The Sensor Brief Operating Instructions are aimed at specialists with responsibility for installing the measuring device.

Incoming acceptance and product identification

Storage and transport

Installation

Transmitter Brief Operating Instructions

The Transmitter Brief Operating Instructions are aimed at specialists with responsibility for commissioning, configuring and parameterizing the measuring device (until the first measured value).

Product description

Installation

Electrical connection

Operation options

System integration

Commissioning

Diagnostic information

Additional device documentation

These Brief Operating Instructions are the Sensor Brief Operating Instructions. The «Transmitter Brief Operating Instructions» are available via:

Internet: www.endress.com/deviceviewer

Smart phone/tablet: Endress+Hauser Operations App

Detailed information about the device can be found in the Operating Instructions and the other documentation:

Internet: www.endress.com/deviceviewer

Smart phone/tablet: Endress+Hauser Operations App

Table of contents

Proline Promag P

Table of contents

1

Document information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . 5

1.1

Symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . 5

2

Basic safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . 8

2.1

Requirements for the personnel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . 8

2.2

Designated use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . 8

2.3

Workplace safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . 9

2.4

Operational safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . 9

2.5

Product safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . 9

2.6

IT security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . 10

3

Incoming acceptance and product identification . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . 11

3.1

Incoming acceptance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . 11

3.2

Product identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . 12

4

Storage and transport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . 13

4.1

Storage conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . 13

4.2

Transporting the product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . 13

5

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . 15

5.1

Installation conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . 15

5.2

Mounting the measuring device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . 20

5.3

Post-installation check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . 23

6

Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . 24

6.1

Removing the measuring device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . 24

6.2

Disposing of the measuring device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . 24

7 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

7.1 Screw tightening torques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

24

Proline Promag P

Document information

1Document information

1.1Symbols used

1.1.1Safety symbols

Symbol Meaning

DANGER!

DANGER This symbol alerts you to a dangerous situation. Failure to avoid this situation will result in serious or fatal injury.

WARNING!

WARNING This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in serious or fatal injury.

CAUTION!

CAUTION This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in minor or medium injury.

NOTE!

NOTICE This symbol contains information on procedures and other facts which do not result in personal injury.

1.1.2Symbols for certain types of information

Symbol

Meaning

Symbol

Meaning

Permitted

Preferred

Procedures, processes or actions that

Procedures, processes or actions that

are permitted.

are preferred.

Forbidden

Tip

Procedures, processes or actions that

Indicates additional information.

are forbidden.

Reference to documentation

A

Reference to page

Reference to graphic

,

,

Series of steps

1.

2.

3.

Result of a step

Visual inspection

1.1.3Electrical symbols

Symbol

Meaning

Symbol

Meaning

Direct current

Alternating current

Direct current and alternating current

Ground connection

A grounded terminal which, as far as

the operator is concerned, is grounded

via a grounding system.

Endress+Hauser

5

Document information

Proline Promag P

Symbol Meaning

Protective Earth (PE)

A terminal which must be connected to ground prior to establishing any other connections.

The ground terminals are situated inside and outside the device:

Inner ground terminal: Connects the protectiv earth to the mains supply.

Outer ground terminal: Connects the device to the plant grounding system.

1.1.4Communication symbols

Symbol

Meaning

Symbol

Meaning

Wireless Local Area Network

Bluetooth

(WLAN)

Wireless data transmission between

Communication via a wireless, local

devices over a short distance.

network.

LED

LED

Light emitting diode is off.

Light emitting diode is on.

LED

Light emitting diode is flashing.

Symbol

Meaning

Symbol

Meaning

Wireless Local Area Network

LED

(WLAN)

Light emitting diode is off.

Communication via a wireless, local

network.

LED

LED

Light emitting diode is on.

Light emitting diode is flashing.

1.1.5Tool symbols

Symbol

Meaning

Symbol

Meaning

Torx screwdriver

Flat blade screwdriver

Cross-head screwdriver

Allen key

Open-ended wrench

1.1.6Symbols in graphics

Symbol

Meaning

Symbol

Meaning

1, 2, 3,…

Item numbers

,

,

Series of steps

1.

2.

3.

A, B, C, …

Views

A-A, B-B, C-C, …

Sections

Proline Promag P

Document information

Symbol

Meaning

Symbol

Meaning

Hazardous area

.

Safe area (non-hazardous area)

Flow direction

Basic safety instructions

Proline Promag P

2Basic safety instructions

2.1Requirements for the personnel

The personnel must fulfill the following requirements for its tasks:

Trained, qualified specialists must have a relevant qualification for this specific function and task.

Are authorized by the plant owner/operator.

Are familiar with federal/national regulations.

Before starting work, read and understand the instructions in the manual and supplementary documentation as well as the certificates (depending on the application).

Follow instructions and comply with basic conditions.

2.2Designated use

Application and media

The measuring device is only suitable for flow measurement of liquids with a minimum conductivity of 5 μS/cm(Promag 100, 300, 500) or 20 μS/cm (Promag 200).

Depending on the version ordered, the measuring device can also measure potentially explosive, flammable, poisonous and oxidizing media.

Measuring devices for use in hazardous areas, in hygienic applications or where there is an increased risk due to process pressure, are labeled accordingly on the nameplate.

To ensure that the measuring device remains in proper condition for the operation time:

Keep within the specified pressure and temperature range.

Only use the measuring device in full compliance with the data on the nameplate and the general conditions listed in the Operating Instructions and supplementary documentation.

Based on the nameplate, check whether the ordered device is permitted for the intended use in the hazardous area (e.g. explosion protection, pressure vessel safety).

Use the measuring device only for media to which the process-wetted materials are sufficiently resistant.

If the measuring device is not operated at atmospheric temperature, compliance with the relevant basic conditions specified in the associated device documentation is absolutely essential: «Documentation» section.

Protect the measuring device permanently against corrosion from environmental influences.

Incorrect use

Non-designated use can compromise safety. The manufacturer is not liable for damage caused by improper or non-designated use.

LWARNING

Danger of breakage due to corrosive or abrasive fluids!

Verify the compatibility of the process fluid with the sensor material.

Ensure the resistance of all fluid-wetted materials in the process.

Keep within the specified pressure and temperature range.

Proline Promag P

Basic safety instructions

NOTICE

Verification for borderline cases:

For special fluids and fluids for cleaning, Endress+Hauser is glad to provide assistance in verifying the corrosion resistance of fluid-wetted materials, but does not accept any warranty or liability as minute changes in the temperature, concentration or level of contamination in the process can alter the corrosion resistance properties.

Residual risks

LWARNING

The electronics and the medium may cause the surfaces to heat up. This presents a burn hazard!

For elevated fluid temperatures, ensure protection against contact to prevent burns.

2.3Workplace safety

For work on and with the device:

Wear the required personal protective equipment according to federal/national regulations.

For welding work on the piping:

Do not ground the welding unit via the measuring device.

If working on and with the device with wet hands:

Due to the increased risk of electric shock, gloves must be worn.

2.4Operational safety

Risk of injury!

Operate the device in proper technical condition and fail-safe condition only.

The operator is responsible for interference-free operation of the device.

Environmental requirements

If a plastic transmitter housing is permanently exposed to certain steam and air mixtures, this can damage the housing.

If you are unsure, please contact your Endress+Hauser Sales Center for clarification.

If used in an approval-related area, observe the information on the nameplate.

2.5Product safety

This measuring device is designed in accordance with good engineering practice to meet state- of-the-art safety requirements, has been tested, and left the factory in a condition in which it is safe to operate.

It meets general safety standards and legal requirements. It also complies with the EU directives listed in the device-specific EU Declaration of Conformity. Endress+Hauser confirms this by affixing the CE mark to the device.

Basic safety instructions

Proline Promag P

2.6IT security

We only provide a warranty if the device is installed and used as described in the Operating Instructions. The device is equipped with security mechanisms to protect it against any inadvertent changes to the device settings.

IT security measures in line with operators’ security standards and designed to provide additional protection for the device and device data transfer must be implemented by the operators themselves.

Loading…

Detail Specifications:

1489/1489086-proline_promag_300.pdf file (25 Feb 2023)

Accompanying Data:

Endress+Hauser Proline Promag 300 Industrial Equipment, Measuring Instruments PDF Safety Instructions (Updated: Saturday 25th of February 2023 05:08:49 AM)

Rating: 4.5 (rated by 63 users)

Compatible devices: Proline Promass O 100HART, Proline Prowirl 72W, Kit CSF48, Fieldgate FXA720, Proline Cubemass C 500, Turbimax CUE25, Proline Prowirl 200, magphant.

Recommended Documentation:

Text Version of Safety Instructions

(Ocr-Read Summary of Contents, UPD: 25 February 2023)

  • 13, Proline Promag 300 XA01514D Endress+Hauser 13 With thermal insulation according to Endress+Hauser specifications For information on the thermal insulation of the device, see the «Thermal insulation» section of the «Technical Information» document NOTICE The following applies for devices with order code for «Housing», Option B «Stainless, hygienic»: ‣ …

  • 1, Endress+Hauser Proline Promag 300 Products Solutions Services Safety Instructions Proline Promag 300 ATEX: II3G IECEx: Zone 2 0 Document: XA01514D Safety instructions for electrical apparatus for explosion- hazardous areas according to Directive 2014/34/EU (ATEX) and IEC 60079-0 →  5 XA01514D/06/EN/03.18 71389339

  • 7, Proline Promag 300 XA01514D Endress+Hauser 7 Affixing the certificate number certifies conformity with the standards under www.IECEx.com (depending on the device version). • IEC 60079-0: 2011 • IEC 60079-7: 2015 • IEC 60079-11: 2011 • IEC 60079-15: 2010 Manufacturer contact address Endress+Hauser Flowtec AG Kägenstrasse 7 4153 Reinach BL Switzerland Extended order code The extended ord…

  • 11, Proline Promag 300 XA01514D Endress+Hauser 11 • Only use certified cable entries that are suitable for the application. Observe selection criteria according to IEC/EN 60079-14 . • When the measuring device is connected, attention must be paid to the type of protection at the transmitter . • In potentially explosive atmospheres: – Do not disconnect the electrical connec…

  • 3, Proline Promag 300 XA01514D Endress+Hauser 3 IT — Istruzioni di sicurezza per apparecchiature elettriche certificate per l’utilizzo in aree con pericolo di esplosione. Se il presente manuale non risulta comprensibile potete ordinarcene una copia tradotta nella vostra lingua. Dichiarazione di conformità UE Con questa dichiarazione e con l’appl…

  • 9, Proline Promag 300 XA01514D Endress+Hauser 9 Position Order code Selected option Description G Pulse/freq./switch output Ex-i H Relay I 4-20mA input J Status input 7 Output, input 3 A W/o; B 4-20mA C 4-20mA Ex-i D Configurable I/O initial setting off E Pulse/freq./switch output F Pulse output, phase-shifted G Pulse/freq./switch output Ex-i H Relay I 4-20mA input J Status input 8 …

  • 17, Proline Promag 300 XA01514D Endress+Hauser 17 Order code for «Output; input 1» Output type Safety-related values «Output; input 1» 26 (+) 27 (–) Option NA EtherNet/IP U N = 30 V DC U M = 250 V AC Option RA PROFINET U N = 30 V DC U M = 250 V AC Order code for «Output; input 2»; «Output; input 3» Output type Safety-related values Ou…

  • 10, Endress+Hauser Proline Promag 300 XA01514D Proline Promag 300 10 Endress+Hauser Safety instructions: General • Staff must meet the following conditions for mounting, electrical installation, commissioning and maintenance of the device: – Be suitably qualified for their role and the tasks they perform – Be trained in explosion protection – Be familiar with national regulations (e.g. IEC/EN 600…

Recommended Instructions:

GA-8VD667, ClassicLite, M1, One-Touch 080309, Compaq LE1711, KAC-PS650D

  • April 2005 Rev.3, 9/15 © 2005-2015 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies. 1587 FC/1587/1577 Insulation Multimeter Users Manual …

    1587 FC 50

  • Closed position indicator that visually and electrically displays when the valve is either in the closed or open position. Mounts directly to the DMV, SV, MVD and HSAV series valves. When the valve is closed (NO position) a orange light is visible, when the valve is open (NC position) a green light is visible.Gases Natural gas, Propane, Noncorrosive gases, and AirSwitch Type SP …

    CPI 400 2

  • IMPORTANT NOTEVERSION 12/12DOM-100 OIL CONSUMPTION INDICATOR ITEM NO.: 10 33 33Dear Customer,Below please nd some changes on our manual.INTENDED USEThis product is designed for installation in heating control systems, to indicate the oil consumption of the nozzle.REPLACING THE BATTERYLive parts may become exposed when opening covers or removing par …

    DOM-100 10

Additional Information:

Popular Right Now:
Operating Impressions, Questions and Answers:

Понравилась статья? Поделить с друзьями:
  • Как скачать 1xbet на андроид в россии пошаговая инструкция
  • Jx 2000 jaguar инструкция по установке
  • Тиогамма в таблетках инструкция по применению цена отзывы аналоги цена
  • Аппарат каскад для магнитотерапии инструкция по применению
  • Гриль тефаль gc242832 инструкция по применению