Reg da руководство по эксплуатации

a-eberle REG-DA Operating Manual

  • Contents

  • Table of Contents

  • Bookmarks

Quick Links

Operating Manual

Transformer-Monitor

TM

Feature TM1 of REG-D

Feature T1 of REG-DA

Transformer-Monitoring-Module TMM for upgrade

g

ISSUE August 2016

loading

Summary of Contents for a-eberle REG-DA

  • Page 1
    Operating Manual Transformer-Monitor Feature TM1 of REG-D Feature T1 of REG-DA Transformer-Monitoring-Module TMM for upgrade ISSUE August 2016…
  • Page 2: Table Of Contents

    We take care of it. Table of Contents User guidance …………………… 4 Target group ……………………..4 Warnings ……………………… 4 Tips ……………………….5 Other symbols ……………………… 5 Applicable documentation ………………….5 Storage ……………………….5 Scope of delivery ………………….5 Safety instructions ………………….6 Basic description of the Transformer Monitor …………..

  • Page 3
    SETUP 3: Alarm ……………………32 5.4.1 Oil temperature (TC) ………………….33 5.4.2 Oil level (TC) ……………………… 33 5.4.3 Oil level (transformer) ………………….34 SETUP 4: Alarm ……………………35 5.5.1 Oil temperature (Alarm) ………………….35 5.5.2 Winding temperature (Alarm) ………………..36 5.5.3 Winding temperature (Trip) ………………..
  • Page 4: User Guidance

    We take care of it. User guidance This user manual contains a summary of the information needed for installation, commis- sioning and operation. Read the user manual entirely and do not use the product unless you have understood its content. Target group The User Manual is intended for skilled technician’s as well trained and certified operators.

  • Page 5: Tips

    Tips Tips on the appropriate use of the device and recommendations. Other symbols Instructions Structure of the instructions:  Instructions for an action.  Indication of an outcome, if necessary. Lists Structure of unnumbered lists: List level 1 – List level 2 Structure of numbered lists: 1) List level 1 2) List level 1…

  • Page 6: Safety Instructions

    REGSys Support on: +49 (0)911 628108-101 or via email at: regsys-support@a-eberle.de. A. Eberle GmbH & Co. KG does not accept any liability for damage or losses of any kind arising from printing errors or changes in this manual.

  • Page 7: Basic Description Of The Transformer Monitor

    These channels can be also added to the REG-D on side. It is not possible to upgrade REG-DA at a later date therefore if TM is required this must be specified at time of ordering. For safety and warranty purposes disassembly of REG-DA is not permitted.

  • Page 8
    We take care of it. The following SCADA protocols are available: IEC 61850 IEC 60870-5-101 IEC 60870-5-103 IEC 60870-5-104 DNP 3.0 / DNP 3.0 over Ethernet MODBUS RTU / TCP SPABUS PROFIBUS Figure 1: Signal diagram Basic description of the Transformer Monitor Page 8 Page 8 LEREF «Verzeichnis Ueberschrift»…
  • Page 9
    The thermal situation in the transformer can be displayed in a graphic (see Figure 2). Please note that it is a simplified view of a complex situation. The ‘simplification’ is based on the following assumptions: the oil temperature in the tank increases linearly from the bottom to the top the average temperature of the winding is linearly parallel to the oil temperature with a constant temperature differential gr increasing from bottom to top the hot-spot temperature (P) is higher than the temperature of the winding at the up-…
  • Page 10
    We take care of it. The basic version has only one current input to determine the hot-spot temperature. Three currents can also be measured through an optional Aron circuit (hardware Characteristic M2). In most cases, this configuration will produce acceptable results because one can assume that the transformer has a more or less balanced load.
  • Page 11
    Block diagram of the hot-spot calculation and the cooling stage control Figure 3: Block diagram : Load factor = I / IN Θ : Hot-spot temperature Θ : Oil temperature (measured) Θ : Expected hot-spot temperature : Hot-spot to top-oil gradient : Winding exponent ∆Θ…
  • Page 12
    We take care of it. If remote temperature gauges are used, both the hot-spot temperature and the oil temper- ature can be provided as mA output. The oil or hot-spot temperature function enables up to six groups of fans, two oil pumps and a heater to be connected.
  • Page 13: Activation Of The Transformer Monitor On The Reg-D(A)

    Activation of the Transformer Monitor on the REG-D(A) The Transformer Monitor is a part of the REG-D(A) firmware and it is managed with the software feature TM. By activating and deactivating the feature TM the Transformer Moni- tor function is switched on and off. To activate the feature TM a key code is necessary.

  • Page 14: Monitor

    We take care of it. Monitor In the main menu (press <Menu>), select the Moni- tor function with the <F4> function key. Press F1 to se- lect the monitor indication. The Monitor’s basic screen shows either the oil tem- perature or the winding temperature as decimal values and a bar graph. The current cool- ing stage is also displayed.

  • Page 15: Oil Temperatures (Tc/Transformer)

    4.2.1 Oil temperatures (TC/Transformer) The temperature can either be displayed as bars or numerically. With the help of the setup menu the maximum temperatures for the transformer and the tap-changer can be set. If the temperature in the tap-changer tank is required, a mA value has to be supplied to the voltage regulator via an analogue input.

  • Page 16: Service Life

    We take care of it. Service life The ‘SERVICE LIFE’ menu, which combines all of the service lives (transformer, fan, pumps), is accessed from the ‘MONITOR’ main menu by pressing <F2>. 4.3.1 Operating hours (1) ‘Operating hours 1’ displays the accumulated operating hours for the transformer (trans- former under voltage), the tap changer and the oil pump.

  • Page 17: Operating Hours (2)

    If the voltage transducer is installed close to the bus bar, the controller will still measure a voltage if the secondary voltage of transformer T1 is switched off because the bus — and thus the voltage transducer — is supplied through the second active transformer T2. Figure 8 displays the secondary control voltage, while the voltage for the operating hour count is tapped from the primary voltage transducer.

  • Page 18: Loss Of Life (Iec)

    We take care of it. 4.3.3 Loss of life (IEC) The loss of life information is derived from the equations specified in IEC 60354 or IEC 60076-7. The loss of life should not be confused with the operating hours described earlier. The ‘Op- erating hour’ log file only counts the time during which the transformer is under voltage, while the loss of life takes thermal ageing into account.

  • Page 19
    The following equation can be derived in common logarithms from equation (1) with Θ 98°C. This relationship is shown in the below table: Θ in °C Relative service life consumption 0.125 0.25 16.0 32.0 64.0 128.0 Example: 10 hours at 104°C and 14 hours at 86°C consume (10 h x 2) + (14 h x 0.25) = 23.5 hours dur- ing an operation period of 24 hours.
  • Page 20: Statistics

    We take care of it. Statistics Please press the <ESC> but- ton (alternatively <MENU> and <F4>) to go to the Moni- Main screen. All the tap changer’s activi- ties are recorded in Statistics < F3 >. The total number of tap changes (65 in the example) and the total number of tap changes under load (26 in the example) are recorded in STATISTICS –1.

  • Page 21: Setup

    SETUP  Press < ESC > (alternatively <Menu> and <F4>) to return to the main monitor menu then press < F5 > to enter the setup. SETUP 1: Regulation  Use the <F2…F5> keys to access the individual sub- menus. 5.1.1 Transformer Parameters A parameter set can be specified for each cooling stage.

  • Page 22
    We take care of it. You may need to contact the manufacturer. The time constant for the winding is the time that would elapse until the hot spot reaches the steady-state final value divided by five. Example: With a time constant of 3000 seconds, it is assumed that after 5 x 3000 s = 15,000 s, mean- ing about 4 hours, the steady-state final value of the hot-spot temperature will be reached.
  • Page 23
    5.1.1.5 Overview of the IEC standard settings Medium and large power transformers Hot spot gradient Winding exponent IEC 60354 Winding exponent IEC 60076-7 Constant IEC 60076-7 Constant 2,0 1,45 IEC 60076-7 Constant IEC 60076-7 w Winding time constant [min] Table 1: IEC standard settings for monitoring parameters * The information „limited oil flow“…
  • Page 24: Regulation Base

    We take care of it. 5.1.2 Regulation base Different reference temperatures can be chosen for the control of the individual fans. Be- cause the temperature for the oil and the winding are related in terms of their formula, both temperatures can be used as base temperature. In order to accommodate their own business philosophy, users can select which rule they use.

  • Page 25: Programming/Setup Of The Control Inputs And Outputs

    Programming/Setup of the control inputs and outputs Both the REG-D and the REG-DA voltage regulators can receive various control signals as binary signals and also output control signals via relay outputs. The following Transformer Monitor specific input functions are available:…

  • Page 26
    Example: To program the regulator as follows: The Oil pump should be controlled by relay output 8 on the REG-DA. Fan group 1 via the output relay 9 Fan group 2 via output relay 10 Fan group 3 via the output relay 11.
  • Page 27: Analog Channels

    The REG-DA can have up to eight analogue inputs and up to seven analogue outputs. How- ever, the number of channels required must be specified at the time of ordering, since changes to the equipment later are not possible in the field.

  • Page 28
    If necessary, limit values can of course be derived from such ‘non-standard inputs’ and output by relay. To do this, please contact the A. Eberle head office by using +49(0)911/628108-101 or regsys-support@a-eberle.de. Setup of the analogue channels Additional Information regarding the analogue channels and the according setup can be found in the manual of the REG-D(A).
  • Page 29: Setup 2: Regulation

    SETUP 2: Regulation  SETUP 2 is accessed by pressing the ‘→’ arrow or <F1> in ‘SETUP 1’. 5.3.1 Calculation  By pressing the <F2> button the menu Calculation set- tings are reached. Here you are able to set the type of cooling and the IEC algorithm that is used for determin- ing the Hot spot temperature.

  • Page 30: Fan Assignment

    We take care of it. Type of oil cooling (inner cooling medium) The following options are available: ON: Stands for ONAN or ONAF cooling OF: Stands for OFAF or OFWF cooling OD: Stands for ODAF or ODWF cooling ON/OF: Stands for switching between ON and OF cooling. In this case, at least one con- trollable oil pump is available: ON/OD: Stands for switching between ON and OD cooling.

  • Page 31: Number Of Fans

    5.3.3 Number of fans As the number of fan groups varies by transformer type, the current number can be en- tered in the menu. As a result, this setting will be adjusted in all menus in which fan control and fan service life parameters are configured. There are a total of six fan cooling groups that are identified in the menu by the numbers 1: to 6:.

  • Page 32: Setup 3: Alarm

    We take care of it. 5.3.4.3 Tap changer switching time The value I t is used to record the quality of the contact load in the tap changer. The cur- rent used to calculate I t is taken from the continuous measurement of the current, while the switching quantity ‘t’ is a tap-changer specific value.

  • Page 33: Oil Temperature (Tc)

    5.4.1 Oil temperature (TC) 5.4.1.1 Maximum value Defines the switch-on point for the alarm signal. Setting range: 0…150°C 5.4.1.2 Switching delay Defines the switch-on delay for the alarm signal. Setting range: 0…900 s 5.4.1.3 Hysteresis Defines the hysteresis for the switching point. Setting range: 1…30 K 5.4.2 Oil level (TC)

  • Page 34: Oil Level (Transformer)

    We take care of it. Hysteresis Defines the hysteresis for both switching points. Setting range: 1 … 30% 5.4.3 Oil level (transformer) Minimum value Defines the switch-on point for the ‘Oil level too low’ alarm signal. Setting range: 0 … 150% Maximum value Defines the switch-on point for the ‘Oil level too high’ alarm signal.

  • Page 35: Setup 4: Alarm

    SETUP 4: Alarm  SETUP 4 is accessed by pressing the ‘→’ arrow or <F1> in SETUP 3. Use <F2…F5> to access other submenus in which limits, switching delays and hysteresis can be selected. In setup 4 the limits for oil temperature alarm, winding tem- perature alarm and the winding temperature trip can be ad- justed.

  • Page 36: Winding Temperature (Alarm)

    We take care of it. 5.5.2 Winding temperature (Alarm) Limit value Defines the switch-on point for the alarm signal. Setting range: 0…200°C Switching delay Defines the switch-on delay for the alarm signal. Setting range: 0…900 s Hysteresis Defines the hysteresis for the switching point. Setting range: 1…30 K 5.5.3 Winding temperature (Trip)

  • Page 37: Setup 5: Alarm Water And Gas In Oil

    SETUP 5: Alarm Water and Gas in oil  SETUP 5 is accessed by pressing the ‘→’ arrow or <F1> in SETUP 4. Use <F2…F5> to access other submenus in which limits, switching delays and hysteresis can be selected. In the setup 5 the parameters of the limits water in Oil, gas in oil, H2 in oil and CO in oil can be set.

  • Page 38: H2 (Hydrogen) In Oil Content

    We take care of it. Switching delay Defines the switch-on delay for the alarm signal. Setting range: 0…900 s Hysteresis Defines the hysteresis for the switching point. Setting range: 1…100000 ppm 5.6.3 H2 (Hydrogen) in Oil content Limit value Defines the switch-on point for the alarm signal. Setting range: 0…1000000 ppm Switching delay Defines the switch-on delay for the alarm signal.

  • Page 39: Setup 6: Lifetime

    Switching delay Defines the switch-on delay for the alarm signal. Setting range: 0…900 s Hysteresis Defines the hysteresis for the switching point. Setting range: 1…100000 ppm SETUP 6: Lifetime  SETUP 6 is accessed by pressing the ‘→’ arrow or <F1>…

  • Page 40: Lifetime Tap Changer

    We take care of it. Operating time mom. (IEC) This is where the IEC-based operating hours (loss of life) are adjusted. Setting range: 0…999999 h 5.7.2 Lifetime Tap changer Switching load This is where the current switching load for the tap changer is adjusted. Setting range: 0…9000000 A Operating time maximal Press <F4>…

  • Page 41: Lifetime Fan

    Operating time mom. The ‘Elapsed operating hours’ parameter is important if the system is not installed at the same time as the transformer and the oil pump. Both parameters may need to be adjusted in conjunction with revisions. Setting range: 0…999999 h 5.7.4 Lifetime Fan The number of parameter/value sets is based on the…

  • Page 42: Retrofit Of Analogue Channels

    We take care of it. Retrofit of analogue channels (only REG-D and TMM) Check the wiring Please check first whether the housing/rack has the wiring for the analogue chan- nels. If this is not the case, a rewiring has to be done. It is recommended that this work be carried out at the A.

  • Page 43
    For retrofitting of analogue modules it is necessary to remove the REG-D™ from the hous- ing. To do so, loosen the four retaining screws and pull the REG-D™ out with aid of the removal tool. Now place the REG-D™ in front of you on a work surface. To ensure correct channel assignment of the analogue channels, insert the REG-D™…
  • Page 44
    Please note that the analogue channels can only be used directly as of firmware version 2.00. With older firmware versions, a background program is necessary. For questions regarding this matter, please contact the A. Eberle REGSys support team (regsys-support@a-eberle.de, +49(0)911/628108-101). Page 44 Page 44 LEREF «Verzeichnis Ueberschrift» * MERGEFORMAT Index…
  • Page 45: Increasing The System’s Hardware Resources

    Increasing the system’s hardware resources To increase the number of channels, multiple interface cards can be connected on the COM 3 (RS485) peripheral interface. Interface cards are available for analogue inputs and outputs (ANA-D) as well as for binary inputs and outputs (BIN-D). It is also possible to communicate directly with other devices through the COM3/Modbus converter.

  • Page 46
    We take care of it. The BIN-D interface card can be supplied with either eight relay outputs or sixteen optically decoupled binary inputs. Figure 10: Hardware extension via BIN-D ANA-D and BIN-D interface cards can be combined on COM3 as desired. Figure 11: Hardware extension via ANA-D and BIN-D Increasing the system’s hardware resources Page 46…
  • Page 47: Com3/Modbus (Rtu Master) Converter

    COM3/Modbus (RTU Master) Converter The COM3/Modbus converter enables serial communication with any sensor or device that supports the Modbus RTU protocol (slave). This enables temperature, gas in oil and ambi- ent measurements to be directly recorded and processed. Conversion to a mA-Signal is no longer necessary.

  • Page 48: Temperature Measurement

    We take care of it. Temperature measurement As described earlier, there are two ways of measuring the oil temperature: The temperature signal is supplied by a temperature transducer as a 4…20 mA signal. The temperature signal is supplied by a PT-100 sensor in a three-wire circuit. Accuracy considerations From a measurement standpoint, the accuracy of the hot-spot temperature recording is es- sentially influenced by the oil temperature measurement.

  • Page 49: Warranty

    A test report of the “Measuring the hot-spot temperature” and “Determining the reduction in lifetime” basic functions is available at A. Eberle GmbH & Co.KG. If you are interested in this test report please contact the REGSys support team (regsys-support@a-eberle.de, +49(0)911/628108-101). Warranty…

  • Page 50
    We take care of it. Notes Notes Page 50 Page 50 LEREF «Verzeichnis Ueberschrift» * MERGEFORMAT Index Fehler! Verwenden Sie die Registerkarte ‘Start’, um Verzeichnis Ueberschrift…
  • Page 51
    Notes Page 51…
  • Page 52
    D-90461 Nuremberg Germany Tel.: +49 (0) 911 / 62 81 08-0 Fax: +49 (0) 911 / 62 81 08-96 E-Mail: info@a-eberle.de http://www.a-eberle.de Copyright by A. Eberle GmbH & Co. KG Subject to change without prior notice. Article no. 584.0791 – FW 2.23/3.23…

This manual is also suitable for:

Reg-d

Страницы 1 2 Далее

Чтобы отправить ответ, вы должны войти или зарегистрироваться

РСС

Сообщений с 1 по 20 из 37

1 2012-06-12 14:46:06

  • OJIEGEK
  • Пользователь
  • Неактивен
  • Зарегистрирован: 2012-06-12
  • Сообщений: 13
  • Репутация : [ 0 | 0 ]

Тема: Срочно REG-DA

Помогите пожалуйста разобраться с REG-DA!!! Первая и самая важная проблема — интеграция устройства в АСУ Микроника по 61850 -? А сегодня случилась вторая проблема — перестал показывать положение? Положения принимаю на модуль потенциометра E97. Сегодня порылся в настройках канала, и после этого показывает 0. Хотя сопротивление приходит правильно. Возможно слетели настройки диапазона сопротивлений, но я не знаю где их настроить, налаживал не я. Может кто-нибудь сталкивался? Выручайте братцы, уже 3 месяца в лесу живу, домой охота, а REG-DA задерживает.

2 Ответ от lik 2012-06-12 16:08:06

  • lik
  • собеседник
  • Неактивен
  • Откуда: Киев
  • Зарегистрирован: 2011-01-09
  • Сообщений: 2,446
  • Репутация : [ 0 | 0 ]

Re: Срочно REG-DA

1.Не налаживал (только проектировал), поэтому непосредственно совета дать не могу. Поэтому если Вы просто хотите совета, и только, то дальше мой пост читать не имеет смысла.
2.Если у Вас есть желание и возможность выйти на спецов по дрессировке, простите, настройки сего зверя, то , в зависимости от того, где расположен Ваш лес, мог бы посоветовать близлежайших спецов. То есть, назовите местоположение данной лесопосадки.

Делай , что должен, и будь, что будет

3 Ответ от OJIEGEK 2012-06-12 16:19:17

  • OJIEGEK
  • Пользователь
  • Неактивен
  • Зарегистрирован: 2012-06-12
  • Сообщений: 13
  • Репутация : [ 0 | 0 ]

Re: Срочно REG-DA

Был бы очень признателен)) Нахожусь на данный момент на НПС-16 в Якутии, в 110 км от Алдана. По сути, местоположение специалиста по REG-DA не важно, телефонная связь здесь есть, позвонить смогу.

4 Ответ от lik 2012-06-12 16:27:18

  • lik
  • собеседник
  • Неактивен
  • Откуда: Киев
  • Зарегистрирован: 2011-01-09
  • Сообщений: 2,446
  • Репутация : [ 0 | 0 ]

Re: Срочно REG-DA

Тут еще вопрос государственных границ и всего с этим связанного. Лучшие спецы — из Германии, где сей зверь и был выведен. Я — гражданин Украины. И,хотя между нашими странами безвизовый режим, проблемы есть (в частности, длительных поездок и пр.).
А российских наладчиков REG-D не знаю. Но уверен, они наверняка есть (я не так давно задавал вопрос по  REG-D, и мне россияне тоже отвечали; значит, кто-то их знает вживую). Стати, поищу тот свой вопрос и дам на него ссылку. А Вы уж обращайтесь к тем ребятам. А может и раньше кто-то ответит.

Делай , что должен, и будь, что будет

5 Ответ от lik 2012-06-12 16:30:34

  • lik
  • собеседник
  • Неактивен
  • Откуда: Киев
  • Зарегистрирован: 2011-01-09
  • Сообщений: 2,446
  • Репутация : [ 0 | 0 ]

Re: Срочно REG-DA

Присоединяйтесь!!! Мы в социальных сетях и на Ютуб.

6 Ответ от OJIEGEK 2012-06-12 16:46:53

  • OJIEGEK
  • Пользователь
  • Неактивен
  • Зарегистрирован: 2012-06-12
  • Сообщений: 13
  • Репутация : [ 0 | 0 ]

Re: Срочно REG-DA

Спасибо. Буду пытаться достучаться до Sm@rt. Информации как-то маловато по REG-DA, а на обучении или презентациях побывать не доводилось.

7 Ответ от dronia 2012-06-12 18:34:52

  • dronia
  • Пользователь
  • Неактивен
  • Зарегистрирован: 2012-06-12
  • Сообщений: 1
  • Репутация : [ 0 | 0 ]

Re: Срочно REG-DA

Мой тебе совет. Брось ты этот REG-D и едь домой. Иначе медведем скоро станешь ICQ/ab :)

8 Ответ от grsl 2012-06-12 20:19:21

  • grsl
  • Администратор
  • Неактивен
  • Зарегистрирован: 2011-01-07
  • Сообщений: 6,122
  • Репутация : [ 0 | 0 ]

Re: Срочно REG-DA

мда-с, шо же вас всех по диким степям и тайгам с джунглями то разбрасало….

из форумчан вроде Дмитрий с этом девайсом имел дело.
сейчас мануал бум искать, с 61850 точно не смогу помочь, а с положением попробуем.

9 Ответ от grsl 2012-06-12 20:28:18

  • grsl
  • Администратор
  • Неактивен
  • Зарегистрирован: 2011-01-07
  • Сообщений: 6,122
  • Репутация : [ 0 | 0 ]

Re: Срочно REG-DA

на кнопку F1 нажимали?

10 Ответ от Михаил Пирогов 2012-06-12 20:38:23

  • Михаил Пирогов
  • Михаил Пирогов
  • Пользователь
  • Неактивен
  • Зарегистрирован: 2011-10-04
  • Сообщений: 1,103
  • Репутация : [ 0 | 0 ]

Re: Срочно REG-DA

OJIEGEK пишет:

Первая и самая важная проблема — интеграция устройства в АСУ Микроника по 61850

Как пессимист в отношении 61850, предлагаю направить на ПС того, кто принял решение применять этот «стандарт». Чтоб в следующий раз применяли нормальные вещи, например ГОСТ Р МЭК 60870-104.

РОССИЯ, Санкт-Петербург, www.i-mt.net

11 Ответ от Conspirator 2012-06-12 22:41:27

  • Conspirator
  • Пользователь
  • Неактивен
  • Зарегистрирован: 2011-01-13
  • Сообщений: 2,457
  • Репутация : [ 6 | 0 ]

Re: Срочно REG-DA

Не надо «переводить» с больной головы на здоровую….. Отправить на подстанцию надо того, кто не проверив совместимость АСУ «Метроника» со стандартом заложил такое решение в проект, а также  не браться за наладку того, с чем не имел дело….. «Потренироваться на кошках» для начала….

12 Ответ от OJIEGEK 2012-06-13 02:14:56

  • OJIEGEK
  • Пользователь
  • Неактивен
  • Зарегистрирован: 2012-06-12
  • Сообщений: 13
  • Репутация : [ 0 | 0 ]

Re: Срочно REG-DA

На кнопку F1 нажимал, но на ней выбор отображения дисплея «регулятор» меняется и все. Мне говорили, что на нее 3 раза нажать и появляются настройки диапазона сопротивлений. Но не появляются. Вот и хотелось бы почитать, где это описано, наверняка я что-то не так делаю. А насчет «не браться не пощупав» где вы видели наладку, которая по всему оборудованию были на курсах или обучение проходили всего оборудования, которое там стоит. Как правило приехал, увидел, победил)))) Тем более разнообразие налаживаемого оборудование сейчас, как в винегрете.

13 Ответ от OJIEGEK 2012-06-13 02:16:25 (2012-06-13 02:40:13 отредактировано OJIEGEK)

  • OJIEGEK
  • Пользователь
  • Неактивен
  • Зарегистрирован: 2012-06-12
  • Сообщений: 13
  • Репутация : [ 0 | 0 ]

Re: Срочно REG-DA

Conspirator пишет:

Отправить на подстанцию надо того, кто не проверив совместимость АСУ «Микроника»(не «Метроника») со стандартом заложил такое решение в проект

А вот это вы верно заметили!

14 Ответ от OJIEGEK 2012-06-13 03:24:17

  • OJIEGEK
  • Пользователь
  • Неактивен
  • Зарегистрирован: 2012-06-12
  • Сообщений: 13
  • Репутация : [ 0 | 0 ]

Re: Срочно REG-DA

Сегодня покопался, и кое-что определил. Хочу подробнее написать суть проблемы. Заходим в Меню-Настройки 6-Общие-Аналоговые-Настройки. Здесь находятся настройки аналоговых каналов. На обоих терминалах они настроены одинаково, Ana3 — mA, Ana4 — Ohm. Оба канала показывали значения. Но вот в одном терминале что-то слетело и сейчас все по нулям. Терминал по каналу не выдает mA из-за этого не меряет сопротивление! А вот почему, не понятно? Попытался сбросить настройки на заводские, настроил все заново, кроме диапазона сопротивлений, о котором и идет речь??? Там еще, как мне говорили, когда настраиваешь диапазон на кнопке «ввод» появляется меню «применение <1>», в котором находятся настройки количества ступеней и шаг. Я его итак нашел, настроил и молчок.

15 Ответ от tequila 2012-06-13 08:55:27

  • tequila
  • tequila
  • Модератор
  • Неактивен
  • Откуда: Чебоксары
  • Зарегистрирован: 2011-01-31
  • Сообщений: 441
  • Репутация : [ 0 | 0 ]

Re: Срочно REG-DA

OJIEGEK пишет:

Conspirator пишет:
Отправить на подстанцию надо того, кто не проверив совместимость АСУ «Микроника»(не «Метроника») со стандартом заложил такое решение в проект
А вот это вы верно заметили!

И не говорите. Я так думаю, там в накладе не остались.

16 Ответ от Михаил Пирогов 2012-06-13 11:53:04

  • Михаил Пирогов
  • Михаил Пирогов
  • Пользователь
  • Неактивен
  • Зарегистрирован: 2011-10-04
  • Сообщений: 1,103
  • Репутация : [ 0 | 0 ]

Re: Срочно REG-DA

Conspirator пишет:

Отправить на подстанцию надо того, кто не проверив совместимость АСУ «Метроника» со стандартом заложил такое решение в проект

А с чего это вы заключаете, что цифровое реле соответствует волшебному 61850? А так же, что АСУ не соответствует 61850? А теперь извечный вопрос, кто проверит и даст такое заключение? Стандарт на то и стандарт, что если он указан в эксплуатационной документации или заявленых характеристиках — значит он поддерживается, значит есть его проверка и необязательно на совместимость с какой-то конкретной компанией производителем. Вот, например, ГОСТ Р МЭК 60870 — это стандарт. Берем TestHarness и отлаживаем. А чтобы отладить 61850 в части той-же АСУ нужно обойти все компании штоль? Где инструменты? Где независимые лаборатории, программы методики испытаний? Этого нет. А пока нет — 61850 нужно применять осторожно.

РОССИЯ, Санкт-Петербург, www.i-mt.net

17 Ответ от tequila 2012-06-13 13:30:12

  • tequila
  • tequila
  • Модератор
  • Неактивен
  • Откуда: Чебоксары
  • Зарегистрирован: 2011-01-31
  • Сообщений: 441
  • Репутация : [ 0 | 0 ]

Re: Срочно REG-DA

Михаил Пирогов пишет:

А с чего это вы заключаете, что цифровое реле соответствует волшебному 61850?

Вот описание на русском http://energan.ru/catalog/power-grid-ma … nt_70.html

а вот сертификаты КЕМА и т.д.. http://www.a-eberle.de/certificates/cer … glish.html

18 Ответ от Михаил Пирогов 2012-06-13 13:58:24

  • Михаил Пирогов
  • Михаил Пирогов
  • Пользователь
  • Неактивен
  • Зарегистрирован: 2011-10-04
  • Сообщений: 1,103
  • Репутация : [ 0 | 0 ]

Re: Срочно REG-DA

Знаю я эти сертификаты с хитро мудреной формулировкой «Изделине не показало несоответствия…». На испытаниях в КЕМА не показало несоответствия. Можно трактовать это так «на испытаниях несоответствия небыли выявлены, но это не значит, что их нет».

РОССИЯ, Санкт-Петербург, www.i-mt.net

19 Ответ от Михаил Пирогов 2012-06-13 14:00:07

  • Михаил Пирогов
  • Михаил Пирогов
  • Пользователь
  • Неактивен
  • Зарегистрирован: 2011-10-04
  • Сообщений: 1,103
  • Репутация : [ 0 | 0 ]

Re: Срочно REG-DA

Кстати, смотрю в описании и вижу: IEC 60870-5-103 или 101. Почему не использовать это?

РОССИЯ, Санкт-Петербург, www.i-mt.net

20 Ответ от tequila 2012-06-13 15:10:27

  • tequila
  • tequila
  • Модератор
  • Неактивен
  • Откуда: Чебоксары
  • Зарегистрирован: 2011-01-31
  • Сообщений: 441
  • Репутация : [ 0 | 0 ]

Re: Срочно REG-DA

Михаил Пирогов пишет:

На испытаниях в КЕМА не показало несоответствия.

Ну надо же хоть на что то опираться. У многих и этого то нет, и вряд ли предвидится в ближайшее время.

Страницы 1 2 Далее

Чтобы отправить ответ, вы должны войти или зарегистрироваться

Назначение

Модуль регулирования REG-DPA применяется в сетях среднего (6-35 кВ) и высокого (110 кВ и выше) напряжения для автоматического регулирования дугогасящих реакторов (ДГР). Кроме того, данное устройство совместно с дугогасящим реактором можно использовать для задач измерения параметров сети и управления дополнительными возможностями системы компенсации сети: резисторы, определение поврежденного фидера (ОПФ) и другие.

Настройка и считывание информации с модулей REG-DPA, происходит не только локально, но и через связь с любым другим устройством (стационарный ПК, ноутбук) с возможностью перепрограммирования задач и интерфейса.

Модуль REG-DPA поставляется в составе системы управления дугогасящим реактором и устанавливается в панель шкафа автоматического управления ЭНСОНС-014.

Также модуль способен устанавливаться:

  • 1. в корпусе для монтажа на стену
  • 2. в корпусе для монтажа в распределительные щиты
  • 3. в корпусе для монтажа на рейку

Основные технические характеристики:

128 x 128 px c LED освещением

4

Сохранение журнала событий

в формате MS Excel и др.

поддержка всех версий Windows

Производство:
A. Eberle GmbH & Co. KG

01

Варианты управления системой

Методы управления

Классическое управление

Стандартно модуль использует различные методы регулирования ДГР. В зависимости от поставленной задачи может регулироваться в процентах или абсолютной величине расстройки. Для воздушных линий с высокой естественной асимметрией может содержаться определенное напряжение смещения и расстройка. Во время замыкания на землю устройство имеет возможность корректировать расстройку ДГР и, таким образом, настроить сеть на резонанс. Также используются различные методы для управления несколькими ДГР при объединении секций (параллельная работа до 4 секций).

Определение поврежденного фидера

Устройство может быть оснащено фоновой программой, которая берет на себя контроль и мониторинг блока детектирования импульсов при использовании метода импульсного обнаружения замыкания на землю в сетях среднего напряжения.
Тем самым можно обеспечить соблюдение необходимых граничных условий для успешного определения местоположения замыкания на землю импульсным методом.

С дополнительным блоком инжекции тока

В некоторых сетевых конфигурациях классическая настройка ДГР затруднена. Например: высокосимметричных сетей (кабельные сети); сетей с измерительным сигналом на уровне перекрестных помех нагрузки (у нелинейных потребителей или с генераторами в сети); сетей ВЛ с переменными условиями небаланса.

Дополнительный блок инжекции тока позволяет нейтрализовать влияние неблагоприятных факторов и осуществить точную настройку дугогасящего реактора на фактическую сеть.

Увеличение активной составляющей тока ОЗЗ

Свободно настраиваемая и автономная автоматика управления резистором позволяет в случае замыкания на землю автоматическое подключение резистора для увеличения остаточного активного тока. Проверка нагрузки на резистор выполняется при помощи теплового контроля, причем в течение подключения учитывается текущее напряжение смещения.

Шеф-монтаж

Наблюдение и организационно-техническое руководство за монтажом оборудования со стороны ЭНСОНС при выполнении монтажных работ специалистами заказчика/подрядчика

Наладка

Осуществление настройки и опробований работы САУ (проверка правильности подключения всех цепей, определение резонансной кривой, установка уставок, контрольная «прогонка» реактора, проверка работы датчиков, консультация персонала)

Расчет емкостных токов

Помощь проектным институтам и заказчику в расчете ёмкостного тока объекта с учетом его режимов работы, рекомендация способа заземления нейтрали, выбор мощности ДГР и Фильтров, а также сопротивлений высокоомного или низкоомного резисторов

Сервисное обслуживание

Комплекс услуг по поддержанию работоспособности товара как в гарантийный период, так и после него, согласно требований руководства по эксплуатации

Download Free PDF

paper cover icon

Download Free PDF

paper cover thumbnail

REG-DA Relay for Voltage Control & Transformer Monitoring g

REG-DA Relay for Voltage Control & Transformer Monitoring g

REG-DA Relay for Voltage Control & Transformer Monitoring g

REG-DA Relay for Voltage Control & Transformer Monitoring g

Profile image of Phạm ThịnhPhạm Thịnh

This user manual contains a summary of the information needed for installation, commissioning and operation. Read the user manual entirely and do not use the product unless you have understood its content.

Понравилась статья? Поделить с друзьями:
  • Энцетрон 1000 мг инструкция по применению цена отзывы аналоги уколы
  • Таблетки монтелукаст цена 10 мг инструкция по применению взрослым цена
  • Зарядное устройство орион pw265 инструкция по эксплуатации видео
  • Дез средство юнит хлор инструкция по применению
  • Отчетность в электронном бюджете пошаговая инструкция