- Manuals
- Brands
- Siemens Manuals
- Switch
- SCALANCE X208
Manuals and User Guides for Siemens SCALANCE X208. We have 2 Siemens SCALANCE X208 manuals available for free PDF download: Compact Operating Instructions, Operating Instructions Manual
Siemens SCALANCE X208 Compact Operating Instructions (110 pages)
Brand: Siemens
|
Category: Network Router
|
Size: 1.07 MB
Table of Contents
-
Deutsch
3
-
Table of Contents
3
-
1 Einleitung
5
-
2 Sicherheitshinweise
7
-
Wichtige Hinweise zum Geräteeinsatz
7
-
-
3 Beschreibung
11
-
Übersicht Produkteigenschaften
11
-
Auspacken und Prüfen
13
-
Lieferumfang
14
-
Einführung
15
-
-
4 Montieren
19
-
Montage
19
-
Hutschienenmontage
21
-
Profilschienenmontage
22
-
Wandmontage
23
-
-
5 Anschließen
25
-
Spannungsversorgung
25
-
Meldekontakt
29
-
Erdung
30
-
-
6 Zulassungen
31
-
Hinweise Zulassungen und Kennzeichnungen
31
-
-
7 Technische Daten
41
-
8 Maßbilder
51
-
Maßzeichnung
51
-
-
-
English
59
-
1 Introduction
61
-
2 Safety Instructions
63
-
Important Notes on Using the Device
63
-
-
3 Description
65
-
Overview of the Product Characteristics
65
-
Unpacking and Checking
67
-
Components of the Product
68
-
Introduction
69
-
-
4 Installation
73
-
Installation on a DIN Rail
75
-
Installation on a Standard Rail
76
-
Wall Mounting
77
-
-
5 Connection
79
-
Power Supply
79
-
Signaling Contact
83
-
Grounding
84
-
-
6 Certifications and Approvals
85
-
Notes on the CE Mark
85
-
-
7 Technical Specifications
95
-
8 Dimension Drawings
105
-
Dimension Drawing
105
-
-
Advertisement
Siemens SCALANCE X208 Operating Instructions Manual (87 pages)
SIMATIC NET, Industrial Ethernet Switches
Brand: Siemens
|
Category: Switch
|
Size: 2.19 MB
Table of Contents
-
Legal Information
2
-
Preface
3
-
Operating Instructions, 03/2015, C79000-G8976-C284
6
-
Table of Contents
9
-
1 Functions
11
-
2 Description of the Device
15
-
Device Views
15
-
The Leds
17
-
LED Display When the Device Starts up
17
-
Power LED «L» (Green/Yellow LED)
17
-
Fault LED «F» (Yellow/Red LED)
18
-
Redundancy Manager LED «RM» (Green LED)
18
-
Standby LED «RM» (Yellow LED)
19
-
Port Leds «P» (Green/Yellow Leds)
20
-
Diagnostics Leds for Optical Connectors «F» (Yellow LED)
20
-
Show Location
20
-
The SET Button
21
-
The C-PLUG
22
-
-
3 Safety Notices
27
-
Safety Notices in General
27
-
Safety Notices for Hazardous Areas
29
-
Security Recommendations
30
-
-
4 Installation
33
-
Safety Notices for Installation
33
-
Installation Options
36
-
Installation on a DIN Rail
37
-
Installation on a Standard Rail
38
-
Wall Mounting
39
-
-
5 Connecting up
41
-
Safety When Connecting up
41
-
Power Supply
44
-
Power Supply Via Terminal Block
44
-
Supply for X208PRO
45
-
Supply for IRT-PRO Devices
45
-
Grounding
48
-
Signaling Contact
49
-
Attachment to Industrial Ethernet
51
-
Electrical Connections
51
-
Electrical Attachments to Industrial Ethernet
51
-
Scalance X
52
-
Electrical Connectors of the X208PRO
53
-
Optical Attachments to Industrial Ethernet
55
-
Multimode Fiber-Optic Cable
55
-
Single Mode Fiber-Optic Cable
56
-
POF and PCF Cables
56
-
Push-Pull Connector for IRT-PRO Devices
58
-
-
6 Approvals
59
-
7 Technical Specifications
67
-
Electrical Data
69
-
Dimension Drawings
77
-
Test of Mechanical Stability
83
-
Training, Service & Support
85
-
Index
87
-
-
Advertisement
Related Products
-
Siemens X208PRO
-
Siemens SCALANCE X-200
-
Siemens SCALANCE X-200RNA
-
Siemens Scalance X204-2 Multimode
-
Siemens X204-2TS
-
Siemens X204-2FM
-
Siemens X204-2LD TS
-
Siemens SCALANCE X206-1LD
-
Siemens SCALANCE X-200IRT
-
Siemens SCALANCE X-200 IRT PRO
Siemens Categories
Controller
Control Unit
Industrial Equipment
Washer
Switch
More Siemens Manuals
Product Characteristics
4.2 SCALANCE X208
Figure 4-6
The following errors/faults can be signaled by the signaling contact:
• The failure of a link at a monitored port.
• The failure of one of the two redundant power supplies.
The connection or disconnection of a communication node on an unmonitored port does not
lead to an error message.
The signaling contact remains activated until the error/fault is eliminated or until the current
status is applied as the new desired status using the button.
When the device is turned off, the signaling contact is always activated (open).
4.2.6
What does the button do?
Using the button, you can display and modify the set fault mask.
After pressing the button, the currently valid fault mask is displayed for approximately 3
seconds. The monitored ports flash at a frequency of 5 Hz.
After 3 seconds the new fault mask is displayed. The flashing frequency is reduced to 2.5
Hz. After a further 3 seconds, the new fault mask is adopted and saved. The monitored ports
are indicated by permanently lit LEDs until the button is released.
As long as the LEDs are still flashing, the saving of the mask can be interrupted by releasing
the button.
If an empty fault mask is set (no port is monitored) or you want to set an empty mask, four 4
LEDs flash on and off alternating with their neighboring LEDs.
At the same time, you can also set the monitoring of the redundant power supply with the
fault mask. Monitoring of the power supply is activated only when both power supplies are
connected when the fault mask is saved.
The factory default is no port monitoring.
If the button is pressed longer (15 seconds), the device is reset to «factory defaults». This is
indicated by all the Port LEDs flashing. During this activity, the device must not be turned off.
4-12
SCALANCE X208 Signaling Contact
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
Commissioning Manual, 1,
Product Characteristics
4.2 SCALANCE X208
Figure 4-6
SCALANCE X208 Signaling Contact
The following errors/faults can be signaled by the signaling contact:
• The failure of a link at a monitored port.
• The failure of one of the two redundant power supplies.
The connection or disconnection of a communication node on an unmonitored port does not
lead to an error message.
The signaling contact remains activated until the error/fault is eliminated or until the current
status is applied as the new desired status using the button.
When the device is turned off, the signaling contact is always activated (open).
4.2.6
SCALANCE X208 Button
What does the button do?
Using the button, you can display and modify the set fault mask.
After pressing the button, the currently valid fault mask is displayed for approximately 3
seconds. The monitored ports flash at a frequency of 5 Hz.
After 3 seconds the new fault mask is displayed. The flashing frequency is reduced to 2.5
Hz. After a further 3 seconds, the new fault mask is adopted and saved. The monitored ports
are indicated by permanently lit LEDs until the button is released.
As long as the LEDs are still flashing, the saving of the mask can be interrupted by releasing
the button.
If an empty fault mask is set (no port is monitored) or you want to set an empty mask, four 4
LEDs flash on and off alternating with their neighboring LEDs.
At the same time, you can also set the monitoring of the redundant power supply with the
fault mask. Monitoring of the power supply is activated only when both power supplies are
connected when the fault mask is saved.
The factory default is no port monitoring.
If the button is pressed longer (15 seconds), the device is reset to «factory defaults». This is
indicated by all the Port LEDs flashing. During this activity, the device must not be turned off.
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
4-12
Commissioning Manual, 1,
- Manuals
- Brands
- Computer Equipment
- Switch
-
Siemens
-
Computer Equipment
-
Switch
Product properties
3.5 SCALANCE X208
SCALANCE X-200
38 Operating Instructions, 12/2011, A5E00349864-19
3.5 SCALANCE X208
3.5.1 SCALANCE X208 product characteristics
Possible attachments
The SCALANCE X208 has eight RJ-45 jacks for the connection of end devices or other
network segments.
Figure 3-3 SCALANCE X208
Скачать
Product properties
3.6 SCALANCE XF208
SCALANCE X-200
Operating Instructions, 12/2011, A5E00349864-19
41
3.6
SCALANCE XF208
3.6.1
SCALANCE XF208 product characteristics
Possible attachments
The SCALANCE XF208 has eight RJ-45 jacks for the connection of end devices or other
network segments.
Figure 3-5
SCALANCE XF208