Shimadzu aa 7000 руководство по эксплуатации

Shimadzu AA-7000 Series Manual

  • Contents

  • Table of Contents

  • Bookmarks

Quick Links

C122-E058G

Atomic Absorption Spectrophotometers

AA-7000

Series

loading

Related Manuals for Shimadzu AA-7000 Series

Summary of Contents for Shimadzu AA-7000 Series

  • Page 1
    C122-E058G Atomic Absorption Spectrophotometers AA-7000 Series…
  • Page 2
    AA — 700 0 Ser ie s Atomic Abso rp ti o n Sp ectro p h o to meter s Reaching Even Greater Heights Enhanced Flame Analysis World-Class High-Sensitivity Furnace Improved Dual Atomizer System Advanced Safety Technology…
  • Page 4
    System Configuration can Evolve with Your Needs The AA-7000 Series can be upgraded by adding units to allow the system to handle the analysis targets. The AA-7000 Series can be upgraded by adding units to allow the system to handle the analysis targets.
  • Page 5
    AUTO AA-7000F/AAC Dual Atomizer System Auto Atomizer Autosampler Changer AUTO Dual Atomizer System Graphite Furnace Automatic adjustment of atomizer Atomizer Automatic serach of burner height *1 Requires ASC stand kit. *2 Requires ASK-7000. *3 Automatic burner height search function can be used. AA-7000F/AAC equips with AAC as standard.
  • Page 6
    Hollow cathode lamp Double-Beam Optics and Stable Hardware Achieve Superior Stability The AA-7000 Series incorporates newly developed 3D double-beam optics. The optical system has been designed to produce its maximum performance for each measurement method through optimal adjustment of the light beam and light beam digital filter, and by using optical components that restrict light…
  • Page 7
    Advantages of the Double-Beam System Long-term stability High sensitivity The graph shows the results of The graph shows the direct measurements on 2 ppm copper (Cu) measurement results for 0.1 conducted over at least one hour. ppm lead (Pb). (The plot shows mean values for 11 repeated measurements.) Over the course of more than 600 Measurement time…
  • Page 8
    (comparison with previous P b 0 . 08 p p b 0 .0 5 pp b Shimadzu models). This superb analysis performance is possible in all fields. M n 0 .0 2 p pb…
  • Page 9
    High-Performance Autosampler Mix and inject up to four sample types (diluted solution, standard solution, sample, matrix modifier, etc.). (Of course, unmixed samples can also be injected.) Select a fluororesin tube or pipette tip as the injection nozzle. Automatic dilution and re-analysis if the calibration curve concentration is exceeded. Example of Automatic Dilution and Re-Analysis Analysis of cadmium (Cd): The maximum concentration of the calibration curve has been set to 1ppb.
  • Page 10
    Improved Dual Atomizer System Single Unit Handles High Concentration to Trace Analysis Samples AA-7000F/AAC creates an integral burner and furnace that remains permanently installed in the combustion chamber. It supports both flame analysis of high concentration samples and furnace analysis of trace samples, without changing the atomizer unit.
  • Page 11
    * Shimadzu in-house investigation. Current as of November 2008. Lamp house Just slide the cover to the side for easy replacement of the hollow cathode lamps through the large opening.
  • Page 12
    Safety is an extremely important consideration for flame atomic absorption spectrophotometers using acetylene gas. The AA-7000 Series instruments are the first* ones in the world fitted with a vibration sensor as standard. They also incorporate a comprehensive range of safety mechanisms, including gas leak detectors.
  • Page 13
    Safety Functions for Flame-Specification Instruments World first! –– flame extinguished automatically by vibration sensor The flame is automatically extinguished when the new built-in sensor detects vibrations. Instruments are completely safe during severe shaking caused by earthquakes. Multimode automatic gas leak check The fuel gas pipes inside the instrument gas controller are automatically checked for gas leaks when the power is turned on and when the flame is extinguished.
  • Page 14
    Dual-Background Correction Functions The optimal background correction methods are installed as standard: high-speed self-reversal method (SR method) and deuterium lamp method (D method). These functions can correct for spectral interference in flame measurement. Selecting the optimal background correction method for each sample ensures accurate and reliable analysis results.
  • Page 15
    Examples of elements and wavelengths causing spectral interference problems due to neighboring lines Measured Element Analytical Line (nm) Coexisting Element Absorption Line (nm) 3 09.2 8 3 0 9 .3 0 1 93.7 6 1 9 3 .7 3 4 22.6 7 4 2 2 .6 4 2 28.8 0 2 2 8 .8 4…
  • Page 16
    Clear, Easy-to-Use Software Features of the WizAArd Software Features of the WizAArd Software Features of the WizAArd Software The WizAArd software used with the AA-7000 runs under Windows 7/ Vista/XP. The WizAArd software used with the AA-7000 runs under Windows 7/ Vista/XP. The WizAArd software used with the AA 7000 runs under Windows 7/ Vista/XP Wizard Functions Make Setting the Conditions So Simple That Even a Novice Can Do It.
  • Page 17
    Software Provides Comprehensive Information Displays and Flexible Settings Software Provides Comprehensive Information Displays and Flexible Settings Sof f tware Provides Comprehensive Information Displays and Flexible Settings Identical software operation for flame and furnace measurements Identical software operation for flame and furnace measurements Identical software operation for flame and furnace measurem Even if the calibration curve is created after sample measurements, Even if the calibration curve is created after sample measurements,…
  • Page 18
    FDA 21 CFR Part 11 Compliance FDA 21 CFR Part 11 Compliance A combination of enhanced WizAArd software with Shimadzu’s network-compatible CLASS-Agent data management software supports FDA 21 CFR Part 11 Compliance. WizAArd used alone provides comprehensive system policy setting, user management, log browser, audit trail, and electronic signature system management functions.
  • Page 19
    When combined with the autosampler, it automatically determines the wavelength accuracy, noise level, baseline drift, absorbance and repeatability, and prints out the results of comparison with the pass criteria. * Data from all Shimadzu analytical instruments can be centrally managed by CLASS-Agent.
  • Page 20
    Standard Parts / PC / Software Common to All AA-7000 Series Models Part Name Quantity Cable set 071-60821-08 (120 V), 071-60825-51 (230 V) Cards (set of 10) 206-52046-91 Instruction manual 206-97176 206-97225 Safety inspection sheet (safety instruction) Declaration of conformity, explanatory notes (ISO-9001)
  • Page 21: Optional Accessories

    Optional Accessories For Flame Analysis Part Name Remarks High-temperature burner head 206-77530-91 Made of pure titanium. Air-cooled. 5 cm slot for N flame Extremely corrosion-resistant Can also be used for Air-C flame. Flow meter kit 206-77617-41 Float-type flow meter for support gas Dimensions: 250 W ×…

  • Page 22
    Environmental standards prescribe the hydride generation method as one method of As, Se, and Sb analysis. 1. Used with the AA-7000 Series, HVG-1 permits the rapid and accurate quantitation of elements such as As, Se, Sb and Hg at several-ppb levels.
  • Page 23
    For High-Sensitivity Hg Analysis Part Name Remarks MVU-1A mercury vaporizer unit 206-58780-XX This mercury vaporizer unit permits analysis using the reduction vaporization –– atomic absorption method. It permits easy, high-sensitivity water quality analysis. ISpecifications Vaporization method: reduction vaporization with a reducing agent Measurement method: recirculation Flow cell: optical path length 100 mm (with quartz window) Sample volume: 250 mL max.
  • Page 24: Specifications

    Specifications Main Unit Basics Wavelength range 185.0 to 900.0 nm Monochromator Aberration-corrected Czerny-Turner mounting, Number of grating grooves: 1800 lines / mm, Focal length: 300 mm Bandwidth 0.2, 0.7, 1.3, 2.0L nm (4-step automatic switching) Detector Photomultiplier tube Optics Optics Optical double-beam BGC-SR (high-speed self-reversal method) (185.0 to 900.0 nm) Background correction method…

  • Page 25
    Controller: 235 W × 110 D × 240 H mm (built into GFA-7000A), 6 kg Required Software Operation Environment Shimadzu recommends the PC and monitor in the PC Set for AA-7000 Series with WizAArd Software Pre-Installed. Purchase a printer separately. The personal computer and monitor specifications are as follows.
  • Page 26
    Installation Conditions Dimensions Dimensions Wall Wall Table Table ø150 to ø200 ø150 to ø200 Exhaust fan Exhaust fan Damper Damper ø150 to ø200 ø150 to ø200 Damper Damper Approx. 500 × 500 Approx. 500 × 500 4 4 15 Both for flame analysis and furnace analysis Both for flame analysis and furnace analysis For furnace analysis For furnace analysis…
  • Page 27
    Make sure all required equipment is available before starting instrument installation. See the installation guidelines for details. Make sure all required equipment is available before starting instrument installation. See the installation guidelines for details. Example of recommended piping for the atomic absorption system Example of recommended piping for the atomic absorption system Temperature range Temperature range…
  • Page 28
    For Research Use Only. Not for use in diagnostic procedures. The contents of this publication are provided to you “as is” without warranty of any kind, and are subject to change without notice. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication.

System Configuration can Evolve

with Your Needs

The AA-7000 Series can be upgraded by adding units to allow the system to handle the analysis targets.

The AA-7000 Series can be upgraded by adding units to allow the system to handle the analysis targets.

AA-7000G

Major Fields of Application

AA-7000 Series supports a wide range of

analysis applications.

Environment

Seawater, river water, effluent,

sludge, air-borne dust

Metals, Semiconductors, Ceramics

Metals, minerals, glass,

ceramics, IC chips

Petroleum, Chemicals, Polymers

Petroleum, oil, catalysts,

chemical products, biodiesel

Medical, Biology, Pharmaceuticals

Blood, animals, plants,

drugs, food products

4

AA — 7000F

AA-7000F/AAC

GFA-7000A

ASC

*1

AA-7000F Manual Burner System

ASC

*1

AA-7000F/AAC Auto Burner System

ASC

*2

AA-7000G

GFA-7000A Auto Sampler System

Analysis Sensitivities

Concentration limit of detection

H

Li

Be

Na

Mg

K

Ca Sc Ti

V

Cr Mn Fe Co Ni Cu Zn

Rb Sr

Y Zr Nb Mo Tc Ru Rh Pd

Cs Ba La

Hf Ta W Re Os Ir

Fr Ra Ac

Ce Pr Nd Pm Sm Eu Gd Tb

Th Pa U Np Pu Am Cm Bk

* May differ according to coexisting substances in the sample.

AAC

AAC

*3

Flame

Furnace

(ppm)

B

C

N

O

Al

Si

P

S

Ga

a

Ge As

Se

Ag

Cd

In

Sn Sb

Te

Pt

Au

Hg

Tl

Pb

Bi

Po

Dy

Ho

Er

Tm

Cf

Es

Fm

Md

GFA

*2

(ppb)

He

F

Ne

Cl

Ar

Br

Kr

I

Xe

At

Rn

Yb

Lu

No

Lr

Detail Specifications:

987/987574-aa7000_series.pdf file (13 Feb 2023)

Accompanying Data:

Shimadzu AA-7000 Series Measuring Instruments PDF Manual  (Updated: Monday 13th of February 2023 10:54:03 PM)

Rating: 4.5 (rated by 7 users)

Compatible devices: MOC63, MOC63u, MI 306, AGS-X Series, MOC-120H, RDO PRO-X, DTVLINK-5, TOC-V CPH.

Recommended Documentation:

Text Version of Manual 

(Ocr-Read Summary of Contents, UPD: 13 February 2023)

  • 24, Shimadzu AA-7000 Series Specifications Basics Main Unit Flame Furnace (GFA-7000A) Wavelength range 185.0 to 900.0 nm Aberration-corrected Czerny-Turner mounting, Number of grating grooves: 1800 lines / mm, Focal length: 300 mm 0.2, 0.7, 1.3, 2.0L nm (4-step automatic switching) . BGC-SR (high-speed self-reversal method) (185.0 to 900.0 nm) . BGC-D2 (D 2 lamp method) (185.0 to 430.0 nm) 6-lamp turret, 2…

  • 25, Shimadzu AA-7000 Series * Notes . The PC, monitor and printer are not included in the standard configuration. Prepare them separately. . The ASC-7000, ASK-7000 and GFA-7000A are optional accessories. . The separately available micro sampling kit is required for the flame micro sampling method. . Microsoft Windows 7 Professional / Vista Business and XP Professional are registered trademarks of Micros…

  • 5, 5 Flame and Measurement Procedures Flame Selection Air-C2H2 N2O-C2H2 HVG MVU H Be NeFONCB Na Mg ArClSPAl KCa Ti CrMnFeCoNiCuZn KrBrGa Rb Sr Y Zr Nb Mo Tc Ru Rh Pd Cd XeITeIn Cs Ba La Fr Ra Ac Hf Ta W Re Os Ir Pt Au RnAtPoBiPbTl Ce Pr Nd Pm Sm Eu Gd Tb LuYbTmErHoDy Th Pa U Np Pu Am Cm Bk LrNoMdFmEsCf He Ag u Ge Si V Li SeAs Sb Hg Sc Sn H HVG AUTO Graphite Furnace Atomizer GFA AA-7000F/AAC Dua…

  • 17, Software Provides Comprehensive Information Displays and Flexible Settings Identical software operation for flame and furnace measurements Combining a high-performance autosampler simplifies advanced settings Even if the calibration curve is created after sample measurements, concentration calculations can be conducted on past data. This allows trial measure…

  • 18, FDA 21 CFR Part 11 Compliance FDA 21 CFR Part 11 Compliance Supports System Management andAccuracy FDA 21 CFR Part 11 Compliance A combination of enhanced WizAArd software with Shimadzu’s network-compatible CLASS-Agent data management software supports FDA 21 CFR Part 11 Compliance. WizAArd used alone provides comprehensive system policy sett…

  • 7, 7 Advantages of the Double-Beam System Support for Developing Analytical Conditions Optional Autosampler Reduces Analysis Workload Long-term stability The graph shows the results of measurements on 2 ppm copper (Cu) conducted over at least one hour. (The plot shows mean values for 11 repeated measurements.) Over the course of more than 600 measurements, th…

  • 9, High-Performance Autosampler High-Sensitivity Application Data (Analysis of Selenium (Se)) Mix and inject up to four sample types (diluted solution, standard solution, sample, matrix modifier, etc.). (Of course, unmixed samples can also be injected.) Select a fluororesin tube or pipette tip as the injection nozzle. Automatic dilution and re-analysis if the calibration curve co…

  • 10, Shimadzu AA-7000 Series AA-7000F/AAC creates an integral burner and furnace that remains permanently installed in the combustion chamber. It supports both flame analysis of high concentration samples and furnace analysis of trace samples, without changing the atomizer unit. The integral construction with the atomizer saves space. AA-7000F enables above function by AAC-7000 (option). * The AAC-70…

  • 6, Detector Hollow cathode lamp Beam splitter Monochromator D2 lamp Chopper mirror Burner head (or graphite tube) Reference beam Sample beam 6 Enhanced Flame Analysis The AA-7000 Series incorporates newly developed 3D double-beam optics. The optical system has been designed to produce its maximum performance for each measurement method through optimal adjustment of the light beam and lig…

  • 20, Standard Parts / PC / Software 20 * The PC, monitor, printer, hollow cathode lamps, high-temperature burner head, pressure regulator and compressor are not included in the standard configuration. Part Name Quantity P/N 071-60821-08 (120 V), 071-60825-51 (230 V)1 206-52046-911 1 206-97176 Common to All AA-7000 Series Models 1 206-97225 1 228-30164 1 037-70238-01 1…

  • 12, Safety is an extremely important consideration for flame atomic absorption spectrophotometers using acetylene gas. The AA-7000 Series instruments are the first* ones in the world fitted with a vibration sensor as standard. They also incorporate a comprehensive range of safety mechanisms, including gas leak detectors. * Shimadzu in-house investigation. Current as of November 2008. Comp…

  • 15, Shimadzu AA-7000 Series D 2 (deuterium lamp) method –– highly sensitive background correction 1. Detection sensitivity is superior to the SR method. Therefore, this method is suitable for the analysis of samples with a simple matrix requiring high sensitivity, such as the measurement of trace levels of impurities in ultrapure water or environmental analyses. 2. As the lighting frequency is higher than with the …

Recommended Instructions:

TravelMate 5720, HMU1342, Waspmote LoRa, MM461P, AVENT SCF213, PixelNet

  • 147LPQ OPERATING MANUAL EM-9516-B Rev.10Digital Panel Meters 47 SeriesPULSE INPUT TOTALIZER(6-digit, LED display type)Model: 47LPQOPERATING MANUALhttp://www.m-system.co.jp/5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPANTe l: +81-6-6659-8201 Fax: +81-6-6659-8510E-mail: [email protected] …

    47 Series 137

  •  Vor Gebrauch lesen! / Read manual before use! / Przeczytać przed użyciem!  Alle Sicherheitshinweise beachten! / Observe all safety information! / Przestrzegać wszystkich wskazówek bezpieczeństwa!  Für künftige Verwendung aufbewahren! / Keep manual for future use! / Przechowywać do przyszłego wykorzystania! 06.2015 0 854.000.0740 Betriebsan …

    DIT 10 67

  • Model 72-8155: OPERATING MANUAL1Table of ContentsTitle PageOverviewInspectionSafety InformationRules For Safe OperationInternational Electrical SymbolsThe Meter StructureFunctional ButtonsDisplay SymbolsMeasurement Operation A. Measuring Resistance B. Diode and Continuity Test C. Capacitance Measurement D. Inductance Measurement E. …

    72-8155 26

  • Heinrichs Messtechnik GmbH OPERATING MANUAL TMU-W / UMC4 November 2020 High-Pressure Coriolis Mass Flow Meter TMU-W Installation and operation manual Please read the instructions carefully and store them in a safe place …

    Heinrichs TMU-W Series 118

Additional Information:

Popular Right Now:
Operating Impressions, Questions and Answers:

Table of Contents for Shimadzu AA-7000 Series:

  • High-Performance Autosampler High-Sensitivity Application Data (Analysis of Selenium (Se)) Mix and inject up to four sample types (diluted solution, standard solution, sample, matrix modifier, etc.). (Of course, unmixed samples can also be injected.) Select a fluororesin tube or pipette tip as the injection nozzle. Automatic dilution and re-analysis if the calibration curve concentration is exceeded. Independent control o

  • D 2 (deuterium lamp) method –– highly sensitive background correction 1. Detection sensitivity is superior to the SR method. Therefore, this method is suitable for the analysis of samples with a simple matrix requiring high sensitivity, such as the measurement of trace levels of impurities in ultrapure water or environmental analyses. 2. As the lighting frequency is higher than with the SR method, it can eliminate noise due to emission components of the flame or graphite tube to permit accu

  • 21 High-density graphite tube 206-50587-11 Pyro-coated graphite tube Platform tube 206-50588-11 Select one of the three types of graphite tubes according to the aim of the analysis. 206-50887-02 MAF-106S compressed gas regulator 040-72019-21 For Argon gas I Specifications GFA-7000A graphite furnace atomizer 206-77777-XX For Furnace Analysis For cooling GFA, 100 VAC, 1100VA, 50/60 Hz CA-1115A-1 cooling water circulation unit 044-01813-01 For connecting GFA and CA-1115A-1Cooler connection kit Parts for cooling water con

  • The optimal background correction methods are installed as standard: high-speed self-reversal method (SR method) and deuterium lamp method (D 2 method). Dual-Background Correction Functions SR (high-speed self-reversal) method –– accurate background correction over a wide range Samples with a complex matrix (Containing a large quantity of a specific element as the main component) Purified water, tap water, environmental water, etc. Samples with a relatively simple matrix Samples suitable for the SR me

  • FDA 21 CFR Part 11 Compliance FDA 21 CFR Part 11 Compliance Supports System Management andAccuracy FDA 21 CFR Part 11 Compliance A combination of enhanced WizAArd software with Shimadzu’s network-compatible CLASS-Agent data management software supports FDA 21 CFR Part 11 Compliance. WizAArd used alone provides comprehensive system poli

  • For High-Sensitivity Hg Analysis MVU-1A mercury vaporizer unit 206-58780-XX This mercury vaporizer unit permits analysis using the reduction vaporization –– atomic absorption method. It permits easy, high-sensitivity water quality analysis. Vaporization method: reduction vaporization with a reducing agent Measurement method: recirculation Flow cell: optical path length 100 mm (with quartz window) Sample volume: 250 mL max.

  • Features of the WizAArd Software The WizAArd software used with the AA-7000 runs under Windows 7/ Vista/XP. Wizard Functions Make Setting the Conditions So Simple That Even a Novice Can Do It. Measurement Screen Layout Shows Measurement Status at a Glance Just set the measurement conditions using WizAArd to complete the general settings. The initial settings can also be completed simply by following the Wizard procedures. Lamp History Function Assists with Lamp Management The accumulated

  • Software Provides Comprehensive Information Displays and Flexible Settings Identical software operation for flame and furnace measurements Combining a high-performance autosampler simplifies advanced settings Even if the calibration curve is created after sample measurements, concentration calculations can be conducted on past data. This allows trial measurements to be directly used as actual measurements. Extrapolation of calibration curve range. If the sample concent

  • Standard Parts / PC / Software 20 * The PC, monitor, printer, hollow cathode lamps, high-temperature burner head, pressure regulator and compressor are not included in the standard configuration. Part Name Quantity P/N 071-60821-08 (120 V), 071-60825-51 (230 V)1 206-52046-911 1 206-97176 Common to All AA-7000 Series Models 1 206-97225 1 228-30164 1 037-70238-01 1 221-40500 3 206-57770 206-777041 206-77551-121 206-84934-671 AA-7000G Stan

  • AA-7000 Series Printed in Japan 3655-09416-30ANS Company names, product/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation or its affiliates, whether or not they are used with trademark symbol “TM” or “®”. Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services. Shimadzu disclaims any proprietary i

  • Pb 0.08ppb Mn 0.02ppb 0.05ppb 0.01ppb Enhanced Sensitivity due to Graphite Furnace Advances in optics and a new graphite furnace design achieve improved lower limits of detection for furnace analysis (comparison with previous Shimadzu models). This superb analysis performance is possible in all fields. Achieves World-Class Lower Limits of Detection Previous New 8 World-Class High-Sensitivity Furnace

  • World first! –– flame extinguished automatically by vibration sensor The flame is automatically extinguished when the new built-in sensor detects vibrations. Instruments are completely safe during severe shaking caused by earthquakes. Multimode automatic gas leak check The fuel gas pipes inside the instrument gas controller are automatically checked for gas leaks when the power is turned on and when the flame is extinguished. Should a gas leak be detected, a warning buzzer sounds and a warning is displayed on the screen. Flame-ret

  • Detector Hollow cathode lamp Beam splitter Monochromator D2 lamp Chopper mirror Burner head (or graphite tube) Reference beam Sample beam 6 Enhanced Flame Analysis The AA-7000 Series incorporates newly developed 3D double-beam optics. The optical system has been designed to produce its maximum performance for each measurement method through optimal adjustment of the light beam and light beam digital filter, and by using optical components that restrict light losses. Double-Beam Optics and Stable Hardware Achieve Superior Stability

  • 7 Advantages of the Double-Beam System Support for Developing Analytical Conditions Optional Autosampler Reduces Analysis Workload Long-term stability The graph shows the results of measurements on 2 ppm copper (Cu) conducted over at least one hour. (The plot shows mean values for 11 repeated measurements.) Over the course of more than 600 measurements, the instrument achieved a relative standard deviation within 1%. High sensitivity The

Questions, Opinions and Exploitation Impressions:

You can ask a question, express your opinion or share our experience of Shimadzu AA-7000 Series device using right now.

[Page 1] Shimadzu AA-7000 Series

C122-E058G Atomic Absorption Spectrophotometers AA-7000 Series

[Page 2] Shimadzu AA-7000 Series

Atomic Absorption Spectrophotometers AA-7000 Series Reaching Even Greater Heights Enhanced Flame Analysis World-Class High-Sensitivity Furnace Improved Dual Atomizer System Advanced Safety Technology

[Page 3] Shimadzu AA-7000 Series

[Page 4] Shimadzu AA-7000 Series

4 The AA-7000 Series can be upgraded by adding units to allow the system to handle the analysis targets. The AA — 7000 Series can be upgraded by adding units to allow the system to handle the analysis targets. System Configuration can Evolve wit…

[Page 5] Shimadzu AA-7000 Series

5 Flame and Measurement Procedures Flame Selection Air-C2H2 N2O-C2H2 HVG MVU H Be NeFONCB Na Mg ArClSPAl KCa Ti CrMnFeCoNiCuZn KrBrGa Rb Sr Y Zr Nb Mo Tc Ru Rh Pd Cd XeITeIn Cs Ba La Fr Ra Ac Hf Ta W Re Os Ir Pt Au RnAtPoBiPbTl Ce Pr Nd Pm Sm Eu Gd T…

[Page 6] Shimadzu AA-7000 Series

Detector Hollow cathode lamp Beam splitter Monochromator D2 lamp Chopper mirror Burner head (or graphite tube) Reference beam Sample beam 6 Enhanced Flame Analysis The AA-7000 Series incorporates newly developed 3D double-beam optics. The optical …

[Page 7] Shimadzu AA-7000 Series

7 Advantages of the Double-Beam System Support for Developing Analytical Conditions Optional Autosampler Reduces Analysis Workload Long-term stability The graph shows the results of measurements on 2 ppm copper (Cu) conducted over at least one hour…

[Page 8] Shimadzu AA-7000 Series

Pb 0.08ppb Mn 0.02ppb 0.05ppb 0.01ppb Enhanced Sensitivity due to Graphite Furnace Advances in optics and a new graphite furnace design achieve improved lower limits of detection for furnace analysis (comparison with previous Shimadzu models). Thi…

[Page 9] Shimadzu AA-7000 Series

High-Performance Autosampler High-Sensitivity Application Data (Analysis of Selenium (Se)) Mix and inject up to four sample types (diluted solution, standard solution, sample, matrix modifier, etc.). (Of course, unmixed samples can also be injected….

[Page 10] Shimadzu AA-7000 Series

AA-7000F/AAC creates an integral burner and furnace that remains permanently installed in the combustion chamber. It supports both flame analysis of high concentration samples and furnace analysis of trace samples, without changing the atomizer uni…

[Page 11] Shimadzu AA-7000 Series

The new drive mechanism halves the switching time between flame and furnace measurements (comparison with previous Shimadzu models). Smallest footprint for a full system Easily attach an autosampler Direct connection of the autosampler to the AA i…

[Page 12] Shimadzu AA-7000 Series

Safety is an extremely important consideration for flame atomic absorption spectrophotometers using acetylene gas. The AA-7000 Series instruments are the first* ones in the world fitted with a vibration sensor as standard. They also incorporate a c…

[Page 13] Shimadzu AA-7000 Series

World first! –– flame extinguished automatically by vibration sensor The flame is automatically extinguished when the new built-in sensor detects vibrations. Instruments are completely safe during severe shaking caused by earthquakes. Multimode…

[Page 14] Shimadzu AA-7000 Series

The optimal background correction methods are installed as standard: high-speed self-reversal method (SR method) and deuterium lamp method (D 2 method). Dual-Background Correction Functions SR (high-speed self-reversal) method –– accurate backg…

[Page 15] Shimadzu AA-7000 Series

D 2 (deuterium lamp) method –– highly sensitive background correction 1. Detection sensitivity is superior to the SR method. Therefore, this method is suitable for the analysis of samples with a simple matrix requiring high sensitivity, such as…

[Page 16] Shimadzu AA-7000 Series

Features of the WizAArd Software The WizAArd software used with the AA-7000 runs under Windows 7/ Vista/XP. Wizard Functions Make Setting the Conditions So Simple That Even a Novice Can Do It. Measurement Screen Layout Shows Measurement Status at a…

[Page 17] Shimadzu AA-7000 Series

Software Provides Comprehensive Information Displays and Flexible Settings Identical software operation for flame and furnace measurements Combining a high-performance autosampler simplifies advanced settings Even if the calibration curve is create…

[Page 18] Shimadzu AA-7000 Series

FDA 21 CFR Part 11 Compliance FDA 21 CFR Part 11 Compliance Supports System Management andAccuracy FDA 21 CFR Part 11 Compliance A combination of enhanced WizAArd software with Shimadzu’s network-compatible CLASS-Agent…

[Page 19] Shimadzu AA-7000 Series

Management Accuracy Management (QA/QC) Functions Permit User Level Management, Audit Trail, and Electronic Signatures QA/QC compatibility The QA/QC functions permit accuracy management. Hardware validation software installed as standard The hardwa…

[Page 20] Shimadzu AA-7000 Series

Standard Parts / PC / Software 20 * The PC, monitor, printer, hollow cathode lamps, high-temperature burner head, pressure regulator and compressor are not included in the standard configuration. Part Name Quantity P/N 071-60821-08 (120 V), 071-60825…

[Page 21] Shimadzu AA-7000 Series

21 High-density graphite tube 206-50587-11 Pyro-coated graphite tube Platform tube 206-50588-11 Select one of the three types of graphite tubes according to the aim of the analysis. 206-50887-02 MAF-106S compressed gas regulator 040-7201…

[Page 22] Shimadzu AA-7000 Series

Optional Accessories / Related Products For AA-7000G For AA-7000F 206-52135-91 206-83755-91 Dimensions: 170 W × 110 D × 110 H mm I.D.: ø25 × 170 mm Heater: PYROMAX DS Furnace Controller Operational temperature range: Ambient to 1100 °C Temperat…

[Page 23] Shimadzu AA-7000 Series

For High-Sensitivity Hg Analysis MVU-1A mercury vaporizer unit 206-58780-XX This mercury vaporizer unit permits analysis using the reduction vaporization –– atomic absorption method. It permits easy, high-sensitivity water quality analysis. V…

[Page 24] Shimadzu AA-7000 Series

Specifications Basics Main Unit Flame Furnace (GFA-7000A) Wavelength range 185.0 to 900.0 nm Aberration-corrected Czerny-Turner mounting, Number of grating grooves: 1800 lines / mm, Focal length: 300 mm 0.2, 0.7, 1.3, 2.0L nm (4-step automatic switch…

[Page 25] Shimadzu AA-7000 Series

* Notes . The PC, monitor and printer are not included in the standard configuration. Prepare them separately. . The ASC-7000, ASK-7000 and GFA-7000A are optional accessories. . The separately available micro sampling kit is required for the flame…

[Page 26] Shimadzu AA-7000 Series

26 Dimensions Above dimensions do not include PC or printer. Wall 870 588 465 280 200 max. Table Approx. 500 × 500 ø150 to ø200 714 1100 to 1200 390 960 700 Both for flame analysis and furnace analysis For furnace analysis 340 415 900 to 1000 960 …

[Page 27] Shimadzu AA-7000 Series

27 Make sure all required equipment is available before starting instrument installation. See the installation guidelines for details. *1 Atomic absorption spectrophotometer stand recommended *2 Maintain a free maintenance space of 150 to 200 mm to…

[Page 28] Shimadzu AA-7000 Series

AA-7000 Series Printed in Japan 3655-09416-30ANS Company names, product/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation or its affiliates, whether or not they are used with trademark symbol “…

Понравилась статья? Поделить с друзьями:
  • Андидак препарат спрей инструкция по применению цена
  • Ноцилин инструкция по применению цена отзывы аналоги
  • Глазные капли ципромед для чего назначают инструкция по применению взрослым
  • Как собрать горизонтальные жалюзи пошаговая инструкция
  • Инструкция по применению дезинфицирующего средства миродез базик