Sick dt50 2 руководство

SICK DT50-2 Pro Operating Instructions Manual

  • Contents

  • Table of Contents

  • Troubleshooting

  • Bookmarks

Quick Links

O P E R A T I N G I N S T R U C T I O N S

DT50-2 Pro

Distance sensor

loading

Related Manuals for SICK DT50-2 Pro

Summary of Contents for SICK DT50-2 Pro

  • Page 1
    O P E R A T I N G I N S T R U C T I O N S DT50-2 Pro Distance sensor…
  • Page 2
    Original document This document is an original document of SICK AG. O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…
  • Page 3: Table Of Contents

    Description of operation…………….6.4.1 Switching mode for Q (“ModeQ ”)……… 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…

  • Page 4
    MF Input………………. 11.4.5 Speed………………11.4.6 Device………………11.4.7 Info……………….. O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…
  • Page 5: About This Document

    … highlights useful tips and recommendations as well as information for efficient and trouble-free operation. 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…

  • Page 6: Scope Of Delivery

    Article number (order number) Year and month of manufacture Serial number O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…

  • Page 7: Safety Information

    Modifications and conversions to the device may result in unforeseeable dangers. 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…

  • Page 8: Requirements For Skilled Persons And Operating Personnel

    Device types with laser class 1: Device types with laser class 2: O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…

  • Page 9: Warning Signs On The Device

    The housing is labeled with a corresponding warning sign. 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…

  • Page 10: Ul Conformity

    Using control elements or settings or executing procedures other than those specified in this document may result in dangerous exposure to radiation. O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK…

  • Page 11: Transport And Storage

    For storage periods of longer than 3 months, check the general condition of all components and packaging on a regular basis. 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…

  • Page 12: Mounting

    The green operating LED lights up. Align the light spot so that the desired object is measured. O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK…

  • Page 13: Electrical Installation

    Group 2: cables sensitive to interference, such as device cables, communica‐ ° tion signals, bus signals 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…

  • Page 14
    Figure 5: Ideal laying – Place cables in different cable channels Figure 6: Alternative laying – Separate cables with metallic separators O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK…
  • Page 15: Connecting The Sensor Electrically

    / inactive Blue Supply voltage: 0 V 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…

  • Page 16
    Output 1: output signal switching device 1 / IO-Link Gray Multifunctional input (MF) O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…
  • Page 17: Operation

    Control elements and status indicators 6.2.1 Indicator lights Operating LED (green) 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…

  • Page 18: Display

    (“SQ”)») Temperature Temperature within the sensor in °C. O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…

  • Page 19: Operating Options

    Any settings you have made will also be saved. 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…

  • Page 20: Operation Via Sopas Et

    USB port cannot provide the required power for operating SiLink2 Master and sensor, also connect SiLink2 Master to the accompanying AC adapter. O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK…

  • Page 21: Operation Via Sopasair (Wi-Fi)

    The following process data formats are available: 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…

  • Page 22: Operation Via Multifunctional Input (Mf)

    Output of a signal if the measured distance value has undershot (High Active) or exceeded (Low Active) the switching point. O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK…

  • Page 23
    Low Active (see figure 10, page 23). 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 24
    → DtO (1point) → Saved to → RUN mode O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…
  • Page 25
    → desired distance in mm → Saved to → RUN mode 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 26
    Position object → Saved to → RUN mode O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…
  • Page 27
    (“Window”) switching mode, which corresponds to the expected behavior with the maximum distance. 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 28
    27). If the logic is modified, the sensor automatically exchanges the values set for near and far accordingly. O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK…
  • Page 29
    → desired distance in mm → Saved to → RUN mode 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 30
    → Switching → Saved to → RUN mode O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…
  • Page 31
    8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 32
    Two teach methods are available for the “Object between sensor and background” (“ObSB (Background)”) switching mode. O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK…
  • Page 33
    Align the sensor with the reference background → Saved to → RUN mode 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 34
    → Low Active → Saved to → RUN mode O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…
  • Page 35
    Align the sensor with the reference background → Saved to → RUN mode 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 36
    Shape of measured objects 1 to 5 Graphic and percentage illustration of the match level O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK…
  • Page 37
    8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 38
    O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…
  • Page 39
    Run mode as a test and observe the results of the shape comparison. 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 40
    After the object is automatically saved to → RUN mode O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…
  • Page 41
    → desired shape trigger threshold → Saved to → RUN mode 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 42
    After the last good object → Saved to → RUN mode O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…
  • Page 43
    Signal level starting when a measurement is no longer possible Maximum signal level 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 44
    → Alarm → Saved to → RUN mode O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…
  • Page 45
    These options are described below. 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 46
    45) or Low Active (see figure 22, page 45). O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…
  • Page 47
    → Saved to → RUN mode 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 48: Function Q 2 /Q A » Output Function

    2 will be “low”. This is also known as a complementary output. This is used if an error notification is needed in the event of cable breakage. O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK…

  • Page 49: Switching Mode For («Modeq («Mode(«Modeq «)

    Taught-in or manually set distance for 20 mA 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…

  • Page 50
    «Behavior if no measurement is possible (NoMeasurement)», page O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK…
  • Page 51
    20 mA or 10 V) or “falling” (distance for 4 mA or 0 V > distance for 20 mA or 10 V). 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 52
    Position object → Saved to → RUN mode O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…
  • Page 53
    → 0-10 V → Saved to → RUN mode 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 54
    Taught-in or manually set match for bad objects Taught-in or manually set match for good objects O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK…
  • Page 55
    Run mode and observe the results of the shape comparison. 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 56
    → Shape → Saved to → RUN mode O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…
  • Page 57: Multifunctional Input («Mf Input»)

    The multifunctional input (MF, at pin 5) is for 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…

  • Page 58
    «Confirmation of the teach via MF via output Q (“Confirm teach”)», page O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK…
  • Page 59
    «Switching mode for Q (“ModeQ ”)», page 49 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 60
    With this function, a confirmation can be output via the switching output Q for each teach via multifunctional input. O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…
  • Page 61
    Return to current switching output. The switching output can be modified via a new teach point. 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 62: Speed Setting («Speed»)

    6%, 18% and 90% for the five predefined speed settings, see «Diagram repeata‐ bility», page O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…

  • Page 63: Device Settings

    IO-Link, all functions available in the sensor can be used. 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…

  • Page 64
    If a pushbutton is pressed when the display is off, the display temporarily switches on again. The messages “Display” and “Off” appear in alternation. O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK…
  • Page 65
    The sensor behaves as follows when the factory settings are active: 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 66
    Integration time: 3.33 ms (medium speed), factor: 8 (HoldX8) Maximum holding time = 8 x 3.33 ms = 26.64 ms O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK…
  • Page 67: Read Out Sensor Information

    Otherwise, the value shift is rejected. 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…

  • Page 68
    Any additional changes made to the switching condition during this period are still not taken into account. O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK…
  • Page 69
    The structure of the process data can be selected from multiple predefined formats. The following formats are available: 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 70
    “Main settings & visualization” page (display of the process data) ■ IO-Link: O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…
  • Page 71
    8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 72
    SOPAS ET: “Identification” page IO-Link: Index 12 (0x0c) “Device Access Locks” O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…
  • Page 73: Maintenance

    Recommended: At least every 6 months. 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…

  • Page 74: Troubleshooting

    → Status is displayed to → RUN mode O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…

  • Page 75: Returns

    Separate the recyclable materials by type and place them in recycling containers. ■ 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…

  • Page 76: Technical Data

    Continuous change of the distance from the object in the measuring range. Lateral entry of the object into the measuring range. O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK…

  • Page 77: Interfaces

    Ambient data Table 22: Ambient data Protection class 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…

  • Page 78: Dimensional Drawing

    (orange) Operating LED (green) Operating buttons and display O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…

  • Page 79
    Status LED Q (orange) Operating LED (green) Wi-Fi antenna 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 80: Accessories

    Accessories and where applicable mounting information can be found online at: • www.sick.com/Dx50-2 O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…

  • Page 81: Appendix

    Distance in m (feet) Figure 33: Characteristic curve for “slow” speed 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…

  • Page 82
    Distance in m (feet) Figure 35: Characteristic curve for “fast” speed O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…
  • Page 83
    Distance in m (feet) Figure 36: Characteristic curve for “super-fast” speed 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 84: Menu Structure

    [0…6000] Figure 37: DT50-2 menu structure (Part 1 of 6) O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…

  • Page 85
    Figure 38: DT50-2 menu structure (Part 2 of 6) 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 86
    [0…6000] Figure 39: DT50-2 menu structure (Part 3 of 6) O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…
  • Page 87
    Figure 40: DT50-2 menu structure (Part 4 of 6) 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 88
    BitFilter (Switch) Figure 41: DT50-2 menu structure (Part 5 of 6) O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…
  • Page 89
    Figure 42: DT50-2 menu structure (Part 6 of 6) 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 90: Reference Tables

    SLW (signal level warn‐ (0x3D) (0x02) ing) Advanced user level O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…

  • Page 91
    Teach length Length of reference Object (0x70) object 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 92: Q 2 Output

    (0x02) → Shape Shape Shape comparison (0x3F) (0x02) O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…

  • Page 93
    Bad Teach Teach Q bad shape toler‐ (0x82) ance 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 94
    (0x3E) → Q switching point (0x3E) (0x01) O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…
  • Page 95
    (0x70) object → Shape Ref. Teach shape Object 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 96: Mf Input

    (0x67) time S-Slow Super slow Super slow (0x67) O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…

  • Page 97: Device

    (0x02) tings NoMeasurement Alarm behavior Alarm behavior (0x68) 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…

  • Page 98: Info

    → — / CountWarn‐ → — / History Advanced user level O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK Subject to change without notice…

  • Page 99
    APPENDIX 8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro Subject to change without notice…
  • Page 100
    E-Mail office@sick.com.gr E-Mail info@sick.ru Vietnam Hong Kong Singapore Phone +65 6744 3732 Phone +852 2153 6300 Phone +65 6744 3732 E-Mail sales.gsg@sick.com E-Mail ghk@sick.com.hk E-Mail sales.gsg@sick.com Detailed addresses and further locations at www.sick.com SICK AG | Waldkirch | Germany | www.sick.com…

Detail Specifications:

2217/2217856-dt502_pro.pdf file (09 May 2023)

Accompanying Data:

SICK DT50-2 Pro Kitchen Appliances PDF Operating Instructions Manual (Updated: Tuesday 9th of May 2023 12:01:38 AM)

Rating: 4.4 (rated by 20 users)

Compatible devices: MLS, RMS1000, GL6L-P1 Series, GLS6, GRL18V, TriSpector1000, TiM2 Series, LMS1104C-111031S01.

Recommended Documentation:

Text Version of Operating Instructions Manual

(Ocr-Read Summary of Contents, UPD: 09 May 2023)

  • 100, Detailed addresses and further locations at www.sick.com Australia Phone +61 (3) 9457 0600 1800 33 48 02 – tollfree E-Mail [email protected] Austria Phone +43 (0) 2236 62288-0 E-Mail [email protected] Belgium/Luxembourg Phone +32 (0) 2 466 55 66 E-Mail [email protected] Brazil Phone +55 11 3215-4900 E-Mail [email protected] Canada Phone +1 905.771.1444 E-Mail [email protected]…

  • 64, SICK DT50-2 Pro 6.4.7.1.1 Operating example via display: Change user level to Advanced Select and activate the “Advanced” user level Operating example or steps: RUN mode → Q 1 Output / to → Device → User level → Easy / to → Advanced → Saved to → RUN mode Necessary default settings: — Factory setting: Easy 6.4.7.2 Lock The pushbuttons on the sensor display can b…

  • 19, SICK DT50-2 Pro Display Symbol in front of the display value Meaning Shape match SH Shape comparison: Degree to which the last viewed object matches the taught-in reference object in % (only availa‐ ble in the “Shape match” mode, see «“Shape comparison” (“Shape”) switching mode», page 36 Briefly pressing the pushbutton in Run mode opens the menu. Briefly pressing the…

  • 42, For the output function Q 2 configure and activate /Q a through switching Operating example or steps: RUN mode → Q 1 Output / to → Q 2 Output → Function Q 2 /Q a → 4 — 20 mA / to → Switching → Saved to → RUN mode Necessary default settings: — Factory setting: 4 — 20 mA Select the “Shape” switching mode for Q 2 Operating example or steps: RUN mode …

  • 18, SICK DT50-2 Pro 2 Status LED Q 1 (orange) 3 Status LED Q 2 / Q A (orange) Table 3: Meaning of the indicator lights Display Condition Meaning Status indicator (1) Power supply available, sensor ready for use Power supply not available Power supply available, sensor ready for use, connection to an IO-Link master available Output display Q 1 (2) Switching output active Swit…

  • 75, SICK DT50-2 Pro 8.2 Returns b Only send in devices after consulting with SICK Service. b The device must be sent in the original packaging or an equivalent padded pack‐ aging. NOTE To enable efficient processing and allow us to determine the cause quickly, please include the following when making a return: ■ Details of the contact person ■ Description of the application ■ Description of th…

  • 98, Display SOPAS ET / SOPASair IO-Link / IODD Index dec (hex) Sub index Value Text → Clamp 1 Clamp 104 (0x68) — 0 Clamp → Hold 1 Hold 104 (0x68) — 1 Hold → Hold32 1 Hold x32 104 (0x68) — 2 Hold x32 → Hold16 1 Hold x16 104 (0x68) — 3 Hold x16 → Hold8 1 Hold x8 104 (0x68) — 4 Hold x8 → Hold4 1 Hold x4 104 (0x68) — 5 Hold x4 → Hold2 1 Hold x2 104 (0x68) — 6 Hold x2 1 Ad…

  • 55, For general information and notes about shape comparison, refer to the “Shape com‐ parison” (“Shape”) switching mode chapter. 6.4.4.2.2 Teachable settings (“Teach”) For the “Shape comparison” (“Shape”) analog mode it is necessary to teach in the length and shape of the reference object. In addition, you have the option of teaching in the scaling of th…

  • 93, Display SOPAS ET / SOPASair IO-Link / IODD Index dec (hex) Sub index Value Text → Alarm 1 Alarm 63 (0x3F) 2 (0x02) 130 Alarm → SLWarning 1 SLW 63 (0x3F) 2 (0x02) 131 SLW (signal level warn‐ ing) 1 Advanced user level Mode Q a Display SOPAS ET / SOPASair IO-Link / IODD Index dec (hex) Sub index Value Text ModeQ a 1 Q a operation mode 75 (0x4B) — — Q a Operation mode → Distan…

  • 36, Manually set the desired distance of the reference background for ObSB mode for Q 2 Operating example or steps: RUN mode → Q 1 Output / to → Q 2 Output → Function Q 2 /Q a / to → Manual Q 2 → Q 2 → 30000 (Note: 3 = flashing 3) / , / , / , / , / to → distance to reference background in mm → Saved to → RUN mode Necessary default settings: Func…

  • 87, −−−−−− −−−−−− −−−−−− −−−−−− −−−−−− −−−−−− −−−−−− −−−−−− RUN Distance/ Signal level/ Signal quality/ Temperature RUN Setting level 2 SET Setting level 1 RUN SET Setting level 3 SET MEN Setting level 4 MEN [200…30000] RUN SL[0… 6000] RUN SQ[0%…100%] RUN [-20°C … +100°C] RUN SH[0%..…

  • 26, Manually switch the logic for Q 1 to “Low Active” Operating example or steps: RUN mode → Q 1 Output → ModeQ 1 / to → Manual Q 1 → Q 1 / to → Q 1 Logic → High Active / to → Low Active → Saved to → RUN mode Necessary default settings: Factory setting or mode Q 1 = DtO (1 point) Factory setting: High Active For the output function…

Recommended Instructions:

MX27U series, EL7JWKLMQ00, PACKAGE TERMINAL, Mighty Mule MM600 ET-PRO, Tundra 2014

  • solida 4solida 5inteso 4sono 5sinus 5de Gebrauchsanleitung | Allesschneideren Operating instructions | Food slicerfr Mode d’emploi | Trancheuse universellebgРъководство за употреба | Универсален уред за рязанеcs Návod k obsluze | Univerzální kráječda Brugsanvisning | Multiskæremaskinees Instrucciones de uso | Cortadora multius …

    Solida 4 93

  • January 2013 Rev. 1 10/18©2013-2018 Fluke Corporation. All rights reserved.All product names are trademarks of their respective companies.Specifications are subject to change without notice.709/709H/710Precision Loop CalibratorUsers ManualShop for Fluke products online at:1.888.610.7664www.MyFlukeStore.com …

    709 48

  • Installationsanleitung Installation Instructions SKS-Kinkel Elektronik GmbH Version: 1.1 Support-Hotline: +49 (0) 2661 98088 112 E-Mail: [email protected] Dokument Art. Nr. 97010601 300098 BUS-Läutewerk …

    300098 24

Additional Information:

Popular Right Now:
Operating Impressions, Questions and Answers:

SICK Manuals and Guides:

The main types of SICK DT50-2 Pro instructions: user guide — rules of useing and characteristics, service manual — repair, diagnostics, maintenance, operation manual — description of the main functions of SICK DT50-2 Pro equipment, etc.

Most of the instructions, that you can see on the site are uploaded by our users. If you have available a manual or document for SICK DT50-2 Pro, which is currently not on the site or present in a different language version, we ask you to upload your document on website, using the «uploading form» available to all registered users.

Напряжение питания UV Пост. ток 10 V … 30 V 1) 2)
Остаточная пульсация ≤ 5 Vss 3)
Потребляемая мощность ≤ 1,7 W 4) 5)
Время инициализации ≤ 300 ms
Время на разогрев ≤ 15 min
Материал корпуса
Цинковое литье под давлением

Акриловое стекло (ПММА)

Вид подключения Разъем, M12, 5-контактный
Индикация 3 x LED, ЖК-дисплей
Вес 235 g
Тип защиты
IP65

IP67

Класс защиты III
1) Предельные значения, с защитой от переполюсовки. Эксплуатация в защищенных от короткого замыкания сетях с силой тока не более 8 A.
2) При использовании IO-Link: UВ > 18 В. При использовании аналогового выхода: UВ > 13 В.
3) Не допускается превышение или занижение допуска UВ.
4) При ≥ 0 °C.
5) Без нагрузки.
ПРОИЗВОДИТЕЛЬНОСТЬ
Диапазон измерения
200 mm … 30.000 mm, 90 % отражения 1) 2)

200 mm … 17.000 mm, 18 % отражения

200 mm … 10.000 mm, 6 % отражения

Объект измерения Естественные объекты
Разрешение 0,1 mm
Точность воспроизведения ≥ 0,5 mm 2) 3) 4)
Точность ± 7 mm 4)
Оценка 0,83 ms … 75 ms, 0,83 мс / 3,33 мс / 8,33 мс / 25 мс / 75 мс 5) 6)
Частота переключения 1000 Гц/250 Гц/100 Гц/33 Гц/11 Гц 5) 6)
Время вывода 0,33 мс/1,33 мс/3,33 мс/10 мс/30 мс 5) 7)
ИСТОЧНИК ИЗЛУЧЕНИЯ Лазер, красный 8)
Класс лазера 2 (IEC 60825-1:2014, EN 60825-1:2014)
Тип. размер светового пятна (расстояние) 10 mm x 10 mm (на 10 м)
Доп. функция Настраиваемая скорость: Super Fast … Super Slow, обучаемый, настраиваемый и инвертируемый аналоговый выход, регулируемый выход Q2: токовый выход / выход напряжения / цифровой выход / Q1 не / деактивирован, Режимы переключения: расстояние до объекта (DtO) / окно переключения / объект между датчиком и фоном (ObSB), обучаемый, настраиваемый и инвертируемый цифровой выход, многофункциональный вход (MF): отключение лазера / внешнее обучение / деактивирован, сброс на заводские настройки, Сравнение формы: на основании характера изменения дистанции, Сохранение измеренного значения, Отключение или блокировка дисплея, Опция простого обучения
Средний срок службы лазера (при 25 °C) 100.000 h
1) На скорости Slow.
2) См. графические характеристики для стабильности повторяемости.
3) Соответствует 1 σ.
4) Отражение 6 % … 90 %.
5) В зависимости от настроенной скорости: Super Fast … Super Slow.
6) Боковой ввод объекта в зону измерения.
7) Непрерывное изменение расстояния до объекта в пределах диапазона измерения.
8) Длина волны: 658 нм; макс. мощность: 250 мВт; длительность импульса: 3 нс; цикл нагрузки: 1/250.
ИНТЕРФЕЙСЫ
IO-Link ✔ , V1.1, COM3 (230,4 kBaud)
Функция Параметры процесса, Настройка, Диагностика, Хранение данных:
Цифровой выход
Количество 1 … 2 1)
Вид Двухтактный режим: PNP/NPN
Функция Дополнительные цифровые выходы (Q, Ǭ)
Регулируемый выход Q2: токовый выход / выход напряжения / цифровой выход / Q1 не / деактивирован
Максимальный выходной ток IА ≤ 100 mA
Аналоговый выход
Количество 1
Вид Токовый выход / Выход напряжения
Функция Регулируемый выход Q2: токовый выход / выход напряжения / цифровой выход / Q1 не / деактивирован
Ток 4 mA … 20 mA, ≤ 450 Ω
Напряжение 0 V … 10 V, ≥ 50 Ω
Разрешение 16 bit
Многофункциональный вход (MF) 1 x 2)
Гистерезис 0 mm … 29.950 mm
1) Выход Q с защитой от короткого замыкания.
2) Время отклика ≤ 60 мс.
ДАННЫЕ ОКРУЖАЮЩЕЙ СРЕДЫ
Рабочий диапазон температур
–40 °C … +65 °C, Uv ≤ 24 V

–30 °C … +80 °C, эксплуатация с 2 охлаждающими пластинами

–30 °C … +140 °C, эксплуатация с 2 охлаждающими пластинами и защитным фильтром

Диапазон температур при хранении –40 °C … +75 °C
Тип. невосприимчивость к постороннему свету 40.000 lx
Виброустойчивость EN 60068-2-6, EN 60068-2-64
Ударопрочность EN 60068-2-27

О производителе Sick

Основанная в 1946 году как небольшая семейная фирма, за время своего существования компания SICK превратилась в крупный международный концерн. Но и сегодня, будучи глобальной компанией, SICK остается семейным предприятием, что отражается на корпоративной культуре в том числе и российской дочерней компании.
На российском рынке компания SICK официально присутствует более 10 лет — с 2004 года.
Бренд SICK является лидирующей торговой маркой в сегментах автоматизации производства и автоматизации логистики, сенсорной техники.
Основными видами продукции торговой марки Sick являются:
приборы контроля промышленных выбросов: газоаналитические системы, измерители запыленности, ультразвуковые измерители скорости газа;
индикаторы уровня сыпучих веществ;
анализаторы технологических и сточных вод;
приборы контроля для туннелей и автомобильных дорог;
сенсорное оборудование для контроля расстояния и положения объектов, определения контрастных и цветовых меток, измерения угловых перемещений, датчики для решения различных задач промышленной автоматизации, датчики для устранения бликов от других объектов, датчики определения цвета, ультразвуковые датчики, которые обнаруживают самые отдалённые и невидимые объекты с помощью ультразвука.
Ассортимент промышленных датчиков SICK включает оптические датчики, индуктивные датчики, емкостные датчики, ультразвуковые датчики, магнитные датчики для пневмоцилиндров, энкодеры и др.
Вся продукция торговой марки SICK соответствует требованиям международного стандарта качества ISO 9001. Приборы контроля промышленных выбросов имеют сертификаты TUV и ЕРА, сертифицированы в России и внесены в реестр средств измерений РФ.

Бесплатный самовывоз из пунктов выдачи заказов

г. Смоленск, 2-й Рославльский пер., 14 Б, Цокольный этаж, оф 6.
Пн — Пт 8 — 19
Суббота 10 — 17
Воскресенье выходной

Доставка по России

Транспортными компаниями (до терминала либо до двери)

СДЭК, Деловые Линии, ЕМС Почта России, DPD

Оперативная доставка в Санкт-Петербург, Екатеринбург, Новосибирск, Нижний Новгород, Краснодар, Самару, Челябинск, Казань, Пермь, Ростов-на-Дону, Уфу, Воронеж, Ижевск, Иркутск, Красноярск, Белгород.

Доставка в Казахстан и Беларусь

Отправляем товары транспортной компанией СДЭК

Доставка по Москве

Стоимость доставки 350 р. за исключением крупногабаритного товара (обговаривается отдельно)