Operating Instructions
SIMOREG DC-MASTER
Converter Commutation Protector
(SIMOREG CCP)
Edition 04
Order No. 6RX1700-0DD74
Related Manuals for Siemens SIMOREG DC-MASTER
Summary of Contents for Siemens SIMOREG DC-MASTER
-
Page 1
Operating Instructions SIMOREG DC-MASTER Converter Commutation Protector (SIMOREG CCP) Edition 04 Order No. 6RX1700-0DD74… -
Page 2
When using a SIMOREG DC-MASTER as basic converter unit: The SIMOREG DC-MASTER must have software release 2.2 or higher. The software release of the SIMOREG DC-MASTER can be read-out at parameters r060 and r065, the software release of the associated SIMOREG CCP can be read-out at parameter n560. -
Page 3: Table Of Contents
Connecting the Firing Unit Trigger Board …………….36 Fuses ……………………….37 Arrangement of the terminals, connectors and fuses………….37 Terminal assignment, connectors……………….38 Commissioning ……………………….41 Operation via the basic unit (SIMOREG DC-MASTER or SINAMICS DCM) ……42 7.1.1 SIMOREG DC-MASTER parameters ………………42 7.1.2 SINAMICS DCM parameters ………………..48 7.1.3…
-
Page 4
Table of Contents 12.2010 Appendix ………………………….73 11.1 Characteristic diagrams ………………….73 11.2 Relevant standards …………………….91 11.3 Certification ……………………..91 11.4 Abbreviations, terminology………………….91 11.5 Environmental compatibility ………………..92 ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 5: Notes
Note the following: WARNING Siemens products are only permitted to be used for the applications listed in the catalog and in the associated technical documentation. If third-party products and components are used, they must be recommended or approved by Siemens. These products can only function correctly and safely if they are transported, stored, set up, mounted, installed, commissioned, operated and maintained correctly.
-
Page 6: Warning Notes
Furthermore, the contents of these operating instructions shall not become a part of or modify any prior or existing agreement, commitment, or legal relationship. The Purchase Agreement contains the complete and exclusive obligations of Siemens, including the warranty provisions. Any statements contained in these operating instructions neither expand nor restrict the scope of these contractual warranty conditions.
-
Page 7
Operating the unit in the immediate vicinity (< 1.5 m) of mobile telephones with a transmitter power of > 1 W may lead to incorrect operation of the unit. Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 8: Electrostatic Sensitive Devices (Esd)
The necessary ESD protective measures are illustrated once again in the following diagram: Seated Standing Seated/standing a conductive floor b ESD table c ESD footwear d ESD overall e ESD wrist strap cabinet ground connection ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions…
-
Page 9: Type Spectrum, Ordering Information
Item Order No. (MLFB) Operating instructions for 6RX1700-0AD64 SIMOREG DC-MASTER and SIMOREG CCP and DriveMonitor in all of the available languages on CD-ROM Operating instructions for 6RX1800-0AD64 SINAMICS DCM and SIMOREG CCP in all of the available languages on DVD…
-
Page 10
Item Order No. (MLFB) Patch cable UTP CAT5 acc. to ANSI/EIA/TIA 568 6RY1707-0AA08 Parallel cable for SIMOREG DC-MASTER 6RA70 / SINAMICS DCM and SIMOREG CCP approx. 5 m Connecting cable, pulse turn-off interface to the parallel SIMOREG CCP connection Connecting cable, summed firing pulse interface to the SIMOREG DC-MASTER (CUD2) Connecting cable «fast pulse cancellation interface»… -
Page 11: Selecting A Suitable Simoreg Ccp
12.2010 Type spectrum, ordering information Selecting a suitable SIMOREG CCP The rated unit data (taking into account the relevant limit values) of the SIMOREG DC-MASTER or SINAMICS DCM and SIMOREG CCP components form the basis for the selection table. 2.3.1 Selection table for 4Q basic units Converter Commutation Protector SIMOREG CCP 6RA70…
-
Page 12
For system configurations, with reduced rate values (e.g. DC rating, US rating, voltage derating), under certain circumstances, suitable combinations of units can be found that are not listed in the table. ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 13: Selection Table For 2Q Basic Units
1000 V / 1500 A 6RA7095-4LS22-0 1000 V / 1900 A 6RA7095-4LS22-5 1000 V / 1900 A 6RA7096-4MS22-0 1140 V / 2200 A = suitable = not suitable (see note) Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions…
-
Page 14
For system configurations, with reduced rate values (e.g. DC rating, US rating, voltage derating), under certain circumstances, suitable combinations of units can be found that are not listed in the table. ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 15: Rating Plate, Packaging Label
Q6 ..QTY 1 VERSION E-STATUS (Version) (Version) Q ..MADE IN EU (AUSTRIA) Packaging label Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions…
-
Page 16: Description, Technical Data
If this is the case, then the following occurs: 1. The firing pulses are immediately disabled in the SIMOREG DC-MASTER or SINAMICS DCM. 2. The basic converter unit sends a turn-off command to the SIMOREG CCP (via the serial interface) 3.
-
Page 17: Technical Data
This is calculated using a software algorithm, and depending on the energy that is dissipated during the quenching operation, is up to approx. 20 min. Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions…
-
Page 18: Block Diagram
Description, technical data 12.2010 Block diagram ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions…
-
Page 19
Units 6RA70…95-6FC00-0 / …95-6KC00-0 (all 2000 A) K2 G2 G1 K1 K2 G2 G1 K1 K1 G1 G2 K2 K1 G1 G2 K2 X 33 X 31 (1C1) (1D1) Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 20: Transport, Unpacking
The packaging materials consist of a cardboard box and corrugated cardboard, and can be disposed of in accordance with local regulations for cardboard packaging materials. If you identify any damage that has occurred in transit, please inform your shipping agent immediately. ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions…
-
Page 21: Installation
UL 508 C. To install the unit, the cabinet must have minimum dimensions of 2200 mm x 600 mm x 600 mm (H x W x D). Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions…
-
Page 22: Dimension Drawing
Installation 12.2010 Dimension drawing 600 A / 1000 A / 1200 A — units: ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions…
-
Page 23
12.2010 Installation 2000 A — units: Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 24: Sinamics Dcm — Installing The Firing Unit Trigger Board
Unit Trigger Board) (Order No.: 6RY1803-0CP00). See chapter 6.3.2. CAUTION Please observe the information provided on «Electrostatic sensitive devices (ESD)» in Chapter 1. WARNING Always carry out the work with the SINAMICS DCM in a no-voltage condition! ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions…
-
Page 25
The BOP holder can be released at the side and swung upwards to route the connecting cable • After connecting the cable (see Chapter 6.3.3) relocate the front cover of the SINAMICS DCM and fasten using all of the screws Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 26: Connecting
Also observe all of the safety instructions in the converter unit operating instructions. Note Please observe the installation instructions for EMC-compliant design of drives in Chapter 6.1 of the operating instructions of the basic SIMOREG DC-MASTER or SINAMICS DCM unit. ENGLISH Siemens AG…
-
Page 27: Cable Lengths
SIMOREG CCP Cable length to connect the AC / SINAMICS DCM connections ..l 1C1 1D1 1C1 1D1 Cable length to connect the DC connections ..l l <1> Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions…
-
Page 28
The minimum required cable length l_min is 3 m. Use 3m lengths each for 1U1, 1V1, 1W1, 1C1, 1D1. Or: e.g. use 1m lengths each for 1U1, 1V1, 1W1 and 5 m lengths each for 1C1, 1D1 ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 29: Recommended Connection
In addition, it must be carefully observed that the total of the delay times of all of the switching elements in the control circuit must not exceed the time set at parameter P089. Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions…
-
Page 30: Connecting A Sinamics Dcm
In addition, it must be carefully observed that the total of the delay times of all of the switching elements in the control circuit must not exceed the time set at parameter P50089. ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions…
-
Page 31: Versions To Interconnect The Main Contactor (Circuit Breaker) K1
SINAMICS DCM SINAMICS DCM 6.2.4 Recommended connection when using a Siemens 3WL circuit breaker If circuit breakers from other manufacturers are used, then the recommended connection described here applies accordingly. It should be noted that the circuit breaker is equipped with a ready to close signal contact (S20,…
-
Page 32
Control voltage -X_SCHÜTZ:4 Fault inv. -X171:46 -X_SCHÜTZ:5 -X171:47 e.g. Relais DC 24 V SIMOREG DC-MASTER B0107 SINAMICS DCM r2139.03 -S11 -S20 Siemens U< Circuit breaker 3WL control unit Control voltage ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 33: Connecting Units In Parallel
12.2010 Connecting Connecting units in parallel 6.3.1 Parallel connection of SIMOREG DC-MASTER units A SIMOREG CCP is directly connected in parallel to each of the converter units connected in parallel (SIMOREG DC-MASTER). X30_PAR X29_PAR X172 X300 X165 1D1 (1C1) 1C1 (1D1)
-
Page 34: Parallel Connection Of Sinamics Dcm Units
The firing pulses are disabled via the fast pulse cancellation interface 3.4. CAUTION The parallel interface (X165, X166) at the SINAMICS DCM is not compatible to the parallel interface (X165) at the SIMOREG DC-MASTER CCP. It is not permissible that both connectors are connected. ENGLISH…
-
Page 35
1D1 (1C1) 1C1 (1D1) 1D1 (1C1) 1C1 (1D1) X166 X165 X177 X165_2 X30_PAR X29_PAR X172 X300 X165 1D1 (1C1) 1C1 (1D1) 1D1 (1C1) 1C1 (1D1) X166 X165 X177 X165_2 Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 36: 6.3.3 Connecting The Firing Unit Trigger Board
6.3.3 Connecting the Firing Unit Trigger Board Routing of the connecting cable «fast pulse cancellation interface» to the SINAMICS DCM with shield support: ① Firing Unit Trigger Board ② Connector X165_2 ③ Shield support ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions…
-
Page 37: Fuses
12.2010 Connecting Fuses Fuses in the armature circuit and in the motor circuit Recommended Siemens semiconductor fuses (depending on the SIMOREG CCP used): Unit Order No. Rated Rated Fuses Fuses (MLFB) current voltage 1U1, 1V1, 1W1 1C1, 1D1 6RA7085-6FC00-0 600 A…
-
Page 38: Terminal Assignment, Connectors
Connection values the same as for the power unit SIMOREG CCP (see above) Control circuit for Wiring, main contactor/circuit breaker main contactor / (see the recommended connection in Chapter 6.2) circuit breaker ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions…
-
Page 39
-7 V/+12 V. Equipotential bonding must be implemented if this cannot be guaranteed. Activating the serial interface by setting the protocol at parameter P790 or p50790. Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 40
Connecting 12.2010 Connecting to a SIMOREG DC-MASTER: X172 X172 MINI-COMBICON MINI-COMBICON Connecting to a SINAMICS DCM: SIMOREG CPP SINAMICS DCM X-172 X-177 MINI COMBICON Connector Board Programming interface for the software update X300 Serial interface RS232 9-pin SUBMIN D socket… -
Page 41: Commissioning
If you encounter specific problems that have not been handled in enough detail for the purposes of the buyer, then please contact your local Siemens office. The use of non-approved parts for carrying out repair work on the unit or handling of the unit by inadequately qualified personnel will result in dangerous conditions with the risk of death, serious physical injury, or extensive damage to equipment.
-
Page 42: Operation Via The Basic Unit (Simoreg Dc-Master Or Sinamics Dcm)
Response of the commutation monitoring U583 Test command for the SIMOREG CCP *) For a description of these parameters, see the operating instructions SIMOREG DC-MASTER Chapter 11 Detailed description of parameters The specified software release refers to the software release of the SIMOREG DC-MASTER…
-
Page 43
Display of the I2t value [from SW 2.1] 0 to 100 Ind: None P052 = 3 (2576) of the voltage limitingchoppers 2 of the SIMOREG CCP Type: O2 Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 44
2500 6RA7093-4LV62-0 2500 6RA7095-4LV62-0 2500 6RA7018-6DS22-0 1300 6RA7025-6DS22-0 1300 6RA7028-6DS22-0 1300 6RA7031-6DS22-0 1300 6RA7075-6DS22-0 1300 6RA7078-6DS22-0 1300 6RA7081-6DS22-0 1300 6RA7085-6DS22-0 1300 6RA7087-6DS22-0 1300 6RA7091-6DS22-0 1300 6RA7093-4DS22-0 1500 6RA7095-4DS22-0 1500 ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 45
1100 6RA7090-6KC00-0 1600 6RA7095-6KC00-0 1600 Note: The setting value for U577 according to the table above defines the maximum permissible value of the voltage limit for the particular unit. Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 46
P351 = -20 % of P078i001 (according to the factory setting). The following upper limit applies for a value of P351 that deviates from the factory setting: ⎛ ⎞ ∗ ∗ ⎜ ⎜ ⎟ ⎟ ⎝ ⎠ Upper limit = ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 47
Type: O2 This memory is updated each time that fault message F030 is output. It includes more detailed information about the cause of the commutation fault, which can be evaluated by Siemens experts. Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector… -
Page 48: Sinamics Dcm Parameters
CCP chopper voltage setpoint, upper response threshold p51578 CCP quenching capacitor pre-charging voltage setpoint r51579.0…7 CO/BO: CCP command p51580 Commutation monitoring, control word p51583 CCP test turn-off command ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions…
-
Page 49
Description: Sets the bus termination for the peer-to-peer interface and the interface to the SIMOREG CCP. Value: 0: off 1: on Note: CCP: Converter Commutation Protector P2P: Peer-to-peer interface Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 50
Displays the software version for the Converter Communication Protector (CCP). Index: [0] = version release of the CCP software [1] = version release of the software of the CCP boot sector ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 51
CO: CCP I2t value voltage limiting chopper 2 / CCP I2t chopper 2 Description: Displays the I2t value for voltage limiting chopper 2 for the Converter Commutation Protector (CCP). Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 52
1700 6RA8090-6GV62-0AA0 1700 6RA8093-4GV62-0AA0 1700 6RA8095-4GV62-0AA0 1700 6RA8096-4GV62-0AA0 1700 6RA8097-4GV62-0AA0 1700 6RA8086-6KV62-0AA0 2100 6RA8090-6KV62-0AA0 2100 6RA8093-4KV62-0AA0 2100 6RA8095-4KV62-0AA0 2100 6RA8097-4KV62-0AA0 2100 6RA8088-6LV62-0AA0 2500 6RA8093-4LV62-0AA0 2500 6RA8095-4LV62-0AA0 2500 6RA8096-4MV62-0AA0 2900 ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 53
The parameter is automatically set for the «Optimization run for CCP» (p50051 = 30). The correct setting for this parameter can be taken from the following reference: SIMOREG CCP operating instructions Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 54
-20 % of p50078[0] (according to the factory setting). The following upper limit applies for a value of p50351 that deviates from the factory setting: ⎛ ⎞ 50351 ⎜ ⎜ ⎟ ⎟ ∗ ∗ 50078 ⎝ ⎠ Upper limit = ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 55
Using this parameter, these can be individually set for test purposes. If several decision-making criteria are to be evaluated, then the sum of the corresponding numbers should be set. Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 56: Simoreg Dc-Master Connectors
(U800 = 0 OR U800 = 1 OR [U800 = 2 AND U806 > 10]) Note: Bits 8 and 9 are always updated. For all other a bits, the following applies: The bits after the first bit with the value zero are invalid! ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions…
-
Page 57: Simoreg Dc-Master Faults
Field current actual value (K0265) for a fault situation i006 Pulse number (K0105) for a fault situation A SIMOREG DC-MASTER connected in parallel has detected a commutation fault or an overcurrent condition Test command was entered via U583…
-
Page 58: Sinamics Dcm Faults
= actual CD voltage r50047[2] = actual delay angle r50047[3] = actual firing instant r50047[4] = actual EMF r50047[5] = actual Ia sampling value r50047[6] = torque direction when triggering ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions…
-
Page 59
The pre-charging of the chopper capacitors was not able to be completed within the time set in p50089 — or the condition according to fault value 5 is fulfilled. Trigger time: 20 ms. Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 60
Note regarding fault value = 707: r50047[1]: Calculated Vmax r50047[2]: Parameter p51578 maximum possible value Note regarding fault value = 708: r50047[1]: Calculated chopper energy r50047[2]: maximum possible chopper energy for SIMOREG ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 61: Simoreg Dc-Master Alarms
Voltage not available at the connections U, V, W of the SIMOREG CCP • Voltage at C-D at the SIMOREG CCP does not match the voltage C-D at the SIMOREG DC-MASTER • The quenching capacitors of the SIMOREG CCP have not reached the setpoint voltage •…
-
Page 62: Commissioning Steps
Determining the setting value for parameter U577 (factory setting = 1600) Required parameter values: r070…MLFB (characteristic number) of the SIMOREG DC-MASTER n570…MLFB (characteristic number) of the SIMOREG CCP ⇒ Determining the setting value according to the parameter description for U577 Commission the basic converter unit according to the operating instructions SIMOREG DC- MASTER, Chapter 7.
-
Page 63
16.0 1.) Rated DC voltage according to the motor rating plate (the values are typical rated data for Siemens DC motors from the product catalog DA12 2.) The characteristic diagrams are provided in the appendix to these operating instructions If the graphically determined value lies below the limit line W_max, then the energy reduction in the armature circuit is assured using the SIMOREG CCP. -
Page 64: Sinamics Dcm Commissioning Steps
This is the reason that before performing the optimization run, the actual value of p50111 should be noted and only set again after the SIMOREG CCP commissioning has been completed. ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions…
-
Page 65
16.0 1.) Rated DC voltage according to the motor rating plate (the values are typical rated data for Siemens DC motors from the product catalog DA12 2.) The characteristic diagrams are provided in the appendix to these operating instructions If the graphically determined value lies below the limit line W_max, then the energy reduction in the armature circuit is assured using the SIMOREG CCP. -
Page 66: Maintenance
12 months. The unit should be cleaned using dry compressed air, max. 1 bar, or using a vacuum cleaner. ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions…
-
Page 67: Software Update Of The Simoreg Ccp
Step 4. monitoring LED at the SIMOREG CCP flashes slowly if communication with the basic unit has been established). Check the new software release at 560 or r51560[0]. Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions…
-
Page 68: Replacing Components
Replace the module(s) Chopper Unit 460 V: MLFB = 6RY1703-0FC01 690 V: MLFB = 6RY1703-0FC02 Note For units 6RA7085-6FC00-0, 6RA7091-6FC00-0 and 6RA7090-6KC00-0, there is only one chopper unit (Item A) ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions…
-
Page 69: Replacing Diode, Thyristor And Igbt Modules
Module design Tightening torque, module: 6 Nm Tightening torque, module: 3,5 Nm Tightening torque of the power connections: 12 Nm Tightening torque of the power connections: 5 Nm Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions…
-
Page 70
The sequence when bolting the IGBT modules can be seen in the adjacent diagram and this must be maintained under all circumstances. Tightening torque, IGBT: 5 Nm Tightening torque of the busbars: 5 Nm ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 71: Service, Technical Support
Our technical support service can provide you with technical assistance for products, systems, and solutions. http://www.siemens.de/automation/support-request (German) http://www.siemens.com/automation/support-request (English) Central hotlines for technical support for SIMOREG CCP / SIMOREG DC-MASTER / SINAMICS DCM: Time zone Tel: +49 (0)911 895 7222 8:00 to 17:00 CET Europe and Africa Fax: +49 (0)911 895 7223 mailto:support.automation@siemens.com…
-
Page 72: Spare Parts
Thyristor module 115x52x50 0,75 6SY7010-0AA22 ..95-6FC00-0 V32+33, MCC312-18io1 V35+38, V36+37, V39, V40 F1, F2 Fuses 20×5 0,002 6RY1702-0BA00 ..85-6FC00-0 on the Power- ..91-6FC00-0 Interface printed ..90-6KC00-0 circuit board ..95-6FC00-0 ..95-6KC00-0 ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions…
-
Page 73: Appendix
Characteristic diagrams to define the voltage setpoint for the pre-charging of the SIMOREG CCP quenching capacitors (parameter U578 for SIMOREG DC-MASTER or p51578 for SINAMICS DCM) using the armature circuit inductance (P111 for SIMOREG DC-MASTER or p50111 for SINAMICS DCM) and the actual unit rated DC armature current (r072i002 for SIMOREG DC- MASTER or r50072[1] for SINAMICS DCM) <…
-
Page 74
6RA7085-6FC00-0 for motors with rated armature voltage 420 V (P101 or p50101) 400A 300A 200A 200A 300A 400A 500A 600A Untergrenze Obergrenze 0.03 0.04 0.05 0.06 0.07 0.08 0.09 Armature circuit inductance in mH (P111 or p50111) ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 75
6RA7085-6FC00-0 for motors with rated armature voltage 470 V (P101 or p50101) 500A 400A 300A 200A 200A 300A 400A 500A 600A Untergrenze Obergrenze 0.03 0.04 0.05 0.06 0.07 0.08 0.09 Armature circuit inductance in mH (P111 or p50111) Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 76
800A 700A 600A 500A 500A 600A 700A 800A 900A 1000A 1100A 1200A Untergrenze Obergrenze 0.03 0.04 0.05 0.06 0.07 0.08 0.09 Armature circuit inductance in mH (P111 or p50111) ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 77
800A 700A 600A 500A 500A 600A 700A 800A 900A 1000A 1100A 1200A Untergrenze Obergrenze 0.03 0.04 0.05 0.06 0.07 0.08 0.09 Armature circuit inductance in mH (P111 or p50111) Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 78
6RA7095-6FC00-0 for motors with rated armature voltage 420 V (P101 or p50101) 1800A 1600A 1400A 1200A 1000A 1000A 1200A 1400A 1600A 1800A 2000A Untergrenze Obergrenze 0.03 0.04 0.05 0.06 0.07 0.08 0.09 Armature circuit inductance in mH (P111 or p50111) ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 79
1000A 1200A 1400A 1600A 2000A 1800A 2000A Untergrenze Obergrenze 1800A 1600A 1400A 1200A 1000A 0.03 0.04 0.05 0.06 0.07 0.08 0.09 Armature circuit inductance in mH (P111 or p50111) Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 80
600A 500A 400A 300A 300A 400A 500A 600A 700A 800A 900A 1000A Untergrenze Obergrenze 0.03 0.04 0.05 0.06 0.07 0.08 0.09 Armature circuit inductance in mH (P111 or p50111) ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 81
600A 500A 400A 300A 300A 400A 500A 600A 700A 800A 900A 1000A Untergrenze Obergrenze 0.03 0.04 0.05 0.06 0.07 0.08 0.09 Armature circuit inductance in mH (P111 or p50111) Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 82
600A 500A 400A 300A 300A 400A 500A 600A 700A 800A 900A 1000A Untergrenze Obergrenze 0.03 0.04 0.05 0.06 0.07 0.08 0.09 Armature circuit inductance in mH (P111 or p50111) ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 83
6RA7095-6KC00-0 for motors with rated armature voltage 600 V (P101 or p50101) 1600A 1400A 1200A 1000A 1000A 1200A 1400A 1600A 1800A 2000A 2200A Untergrenze Obergrenze 0.03 0.04 0.05 0.06 0.07 0.08 0.09 Armature circuit inductance in mH (P111 or p50111) Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 84
6RA7095-6KC00-0 for motors with rated armature voltage 600 V (P101 or p50101) 1600A 1400A 1200A 1000A 1000A 1200A 1400A 1600A 1800A 2000A 2200A Untergrenze Obergrenze 0.03 0.04 0.05 0.06 0.07 0.08 0.09 Armature circuit inductance in mH (P111 or p50111) ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 85
2000A 1800A 1600A 1400A 1200A 1000A 1000A 1200A 1400A 1600A 1800A 2000A Untergrenze Obergrenze 0.03 0.04 0.05 0.06 0.07 0.08 0.09 Armature circuit inductance in mH (P111 or p50111) Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 86
10 mH 8 mH 4 mH 6 mH 8 mH 10 mH 4 mH 2 mH 1000 1100 1200 Actual unit rated DC armature current in A (r072i002 or r50072[1]) ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 87
10 mH 4 mH 8 mH 6 mH 8 mH 10 mH 6 mH 4 mH 2 mH 1000 Actual unit rated DC armature current in A (r072i002 or r50072[1]) Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 88
W_max 2 mH 4 mH 6 mH 8 mH 6 mH 10 mH 4 mH 2 mH 1000 Actual unit rated DC armature current in A (r072i002 or r50072[1]) ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 89
6 mH 8 mH 10 mH 2 mH 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 Actual unit rated DC armature current in A (r072i002 or r50072[1]) Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 90
6 mH 8 mH 10 mH 2 mH 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 Actual unit rated DC armature current in A (r072i002 or r50072[1]) ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions… -
Page 91: Relevant Standards
Abbreviations, terminology Communauté Européenne cULus for ready-to-connect products, tested by UL in accordance with the UL and CSA standards Underwriters Laboratories Converter Commutation Protector IGBT insulated gate bipolar transistor Siemens AG 6RX1700-0DD74 ENGLISH SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions…
-
Page 92: Environmental Compatibility
The printed circuit boards may be used in recycling processes involving energy recovery. The proportion of components containing hazardous substances is low. ENGLISH Siemens AG 6RX1700-0DD74 SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions…
-
Page 94
The following versions have appeared so far: Version Internal Part No. C98130-A7046-A1-01-7419 C98130-A7046-A1-02-7419 C98130-A7046-A1-03-7419 C98130-A7046-A1-04-7419 SIMEA © Siemens AG, 2005-2010 Siemens Industrial Manufacturing, Subject to change without notice Engineering and Applications Order No.: 6RX1700-0DD74 Postfach 83, A-1211 Wien Printed in EU (Austria)
- Manuals
- Brands
- Siemens Manuals
- Servo Drives
- SIMOREG DC Master 6RA7025-6DS22
Manuals and User Guides for Siemens SIMOREG DC Master 6RA7025-6DS22. We have 1 Siemens SIMOREG DC Master 6RA7025-6DS22 manual available for free PDF download: Operating Instructions Manual
Siemens SIMOREG DC Master 6RA7025-6DS22 Operating Instructions Manual (616 pages)
Microprocessor-Based Converters from 6kW to 1900kW for Variable-Speed DC Drives 6RA70 Series
Brand: Siemens
|
Category: Servo Drives
|
Size: 10 MB
Table of Contents
-
Table of Contents
3
-
Contents
10
-
1 Safety Information
15
-
Type Spectrum
15
-
Converter Order Number Code
18
-
Ordering Information for Options Using Codes
19
-
Applications
23
-
-
Description
23
-
Design
23
-
Special Features of Devices with 460V Rated Connection Voltage
24
-
Mode of Operation
24
-
Technical Data
25
-
-
Load Types
25
-
Load Cycles for 1Q Applications
26
-
Load Cycles for 4Q Applications
27
-
Converters 3AC 400V, 30A to 125A, 1Q
29
-
Converters 3AC 400V, 210A to 600A, 1Q
30
-
Converters 3AC 400V, 850A to 2000A, 1Q
31
-
Converters 3AC 460V, 30A to 125A, 1Q
32
-
Converters 3AC 460V, 210A to 600A, 1Q
33
-
Converters 3AC 460V, 850A to 1200A, 1Q
34
-
Converters 3AC 575V, 60A to 600A, 1Q
35
-
Converters 3AC 575V, 800A to 2000A, 1Q
36
-
Converters 3AC 690V, 720A to 2000A, 1Q
37
-
Converters 3AC 830V, 900A to 1900A, 1Q
38
-
Converters 3AC 400V, 15A to 125A, 4Q
39
-
Converters 3AC 400V, 210A to 600A, 4Q
40
-
Converters 3AC 400V, 850A to 2000A, 4Q
41
-
Converters 3AC 460V, 30A to 125A, 4Q
42
-
Converters 3AC 460V, 210A to 600A, 4Q
43
-
Converters 3AC 460V, 850A to 1200A, 4Q
44
-
Converters 3AC 575V, 60A to 600A, 4Q
45
-
Converters 3AC 575V, 850A to 2000A, 4Q
46
-
Converters 3AC 690V, 760A to 2000A, 4Q
47
-
Converters 3AC 690V, 950A to 1900A, 4Q
48
-
Applicable Standards
50
-
Abbreviations
50
-
-
-
Shipment, Unpacking
51
-
Remove the Transportation Protection for Devices with 1500A to 2000A Rated DC
51
-
-
Installation
53
-
Converters: 30A, 1Q
55
-
Dimension Diagrams for Standard Devices
55
-
Converters: 60A to 280A, 1Q
56
-
Converters: 400A, 1Q
57
-
Converters: 600A, 1Q
58
-
Converters: 720A to 850A, 1Q
59
-
Converters: 900A to 1200A, 1Q
60
-
Converters: 1500A to 2000A, 1Q
61
-
Converters: 15A to 30A, 4Q
62
-
Converters: 60A to 280A, 4Q
63
-
Converters: 400A to 600A, 4Q
64
-
Converters: 760A to 850A, 4Q
65
-
Converters: 950A to 1200A, 4Q
66
-
Converters: 1500A to 2000A, 4Q
67
-
Dimension Diagrams of the Devices with Additional Cable Connections on the Top of the Device
68
-
-
Converters: 60A to 125A, 1Q
68
-
Converters: 210A to 280A, 1Q
69
-
Converters: 450A to 600A, 1Q
70
-
Converters: 850A, 1Q
71
-
Converters: 60A to 125A, 4Q
72
-
Converters: 210A to 280A, 4Q
73
-
Converters: 450A to 600A, 4Q
74
-
Converters: 850A, 4Q
75
-
Mounting Options
76
-
-
Terminal Expansion Board CUD2
76
-
Local Bus Adapter (LBA) for Mounting Optional Supplementary Boards
77
-
Optional Supplementary Boards
77
-
Mounting of Optional Supplementary Boards
78
-
-
-
Connections
79
-
Installation Instructions for Proper EMC Installation of Drives
80
-
Fundamental Principles of EMC
80
-
Limit Values
80
-
Noise Radiation and Noise Immunity
80
-
What Is EMC
80
-
EMC Planning
81
-
Non-Grounded Supply Systems
81
-
SIMOREG Converters in Industrial Applications
81
-
General
82
-
Proper EMC Installation of Drives (Installation Instructions)
82
-
Rules for Proper EMC Installation
82
-
Information on Line-Side Harmonics Generated by Converters in a
93
-
Fully-Controlled Three-Phase Bridge Circuit Configuration
93
-
Block Diagrams with Recommended Connection
95
-
Parallel Connection of Converters
96
-
-
Circuit Diagram Showing Parallel Connection of SIMOREG Converters
96
-
Parameterization of SIMOREG Converters for Parallel Connection
97
-
Standard Operating Mode
97
-
Operating Mode «N+1 Mode» (Redundancy Mode)
98
-
Power Connections
100
-
-
Converters: 30A, 1Q
100
-
Converters: 60A, 1Q
101
-
Converters: 90A to 280A, 1Q
102
-
Converters: 400A to 600A, 1Q
103
-
Converters: 720A, 1Q
104
-
Converters: 800 to 850A, 1Q
105
-
Converters: 900A to 950A, 1Q
106
-
Converters: 1000 to 1200A, 1Q
107
-
Converters: 1500 to 2000A, 1Q
108
-
Converters: 15 to 30A, 4Q
110
-
Converters: 60A, 4Q
111
-
Converters: 90A to 210A, 4Q
112
-
Converters: 280A, 4Q
113
-
Converters: 400A, 4Q
114
-
Converters: 450A to 600A, 4Q
115
-
Converters: 760A, 4Q
116
-
Converters: 850A, 4Q
117
-
Converters: 950A to 1000A, 4Q
118
-
Converters: 1100 to 1200A, 4Q
119
-
Converters: 1500 to 2000A, 4Q
120
-
Field Supply
122
-
Fuses and Commutating Reactors
125
-
-
Commutating Reactors
125
-
Converters 1Q: 400V, 575V, 690V and 830V
125
-
Fuses
125
-
Fuses for Armature Circuit
125
-
Recommended Fuses for Field Circuit
125
-
Converters 1Q: 460V
126
-
Converters 4Q: 400V, 575V, 690V and 830V
127
-
Converters 4Q: 460V
128
-
F1 and F2 Fuses in the Power Interface
128
-
Terminal Arrangement
129
-
Terminal Assignments
132
-
-
Start-Up
143
-
General Safety Information
143
-
Operator Control Panels
145
-
Simple Operator Control Panel (PMU)
145
-
User-Friendly Operator Control Panel (OP1S)
146
-
Parameterization Procedure
148
-
-
Parameter Types
148
-
Parameteratization on Simple Operator Control Panel
148
-
Reset to Default Value and Adjust Offset
150
-
Start-Up Procedure
151
-
Manual Optimization (if Necessary)
158
-
-
Manual Setting of Armature Resistance R a (P110) and Armature Inductance L a (P111)
159
-
Manual Setting of Field Resistance R F (P112)
160
-
Starting up Optional Supplementary Boards
161
-
-
Procedure for Starting up Technology Boards (T100, T300, T400)
161
-
Sequence of Operations for Starting up PROFIBUS Boards (CB1, CBP, CBP2)
162
-
-
Servicing
164
-
Sequence of Operations for Starting up CAN Bus Boards (CB2, CBC)
169
-
Procedure for Starting up SIMOLINK Boards (SLB)
175
-
Procedure for Staring up Expansion Boards (EB1 and EB2)
178
-
Procedure for Starting up the Pulse Encoder Board (SBP)
179
-
-
Function Diagrams
181
-
-
9 Function Descriptions
293
-
General Explanations of Terms and Functionality
293
-
Computation Cycles, Time Dela
297
-
Switch-On, Shutdown, Enabling
298
-
Switch-On / Shutdown (on / OFF) Terminal 37 — Control Word 1, Bit 0
299
-
Operating Enable (Enable) Terminal 38 — Control Word 1, Bit 3
302
-
Definitions
303
-
Control Signals for Ramp-Function Generator
304
-
Ramp-Up Integrator
305
-
Limitation after Ramp-Function Generator
306
-
Crawling
307
-
Safety Shutdown (E-Stop)
308
-
Activation Command for Holding or Operating Brake (Low Active)
309
-
-
Switch on Auxiliaries
312
-
Speed Controller
313
-
Serial Interfaces
314
-
Serial Interfaces with Peer-To-Peer Protocol
317
-
Dynamic Overload Capability of Power Section
324
-
Configuring for Dynamic Overload Capability
325
-
Characteristics for Determining the Dynamic Overload Capability for Intermittent Overload Operation
327
-
Speed-Dependent Current Limitation
357
-
Setting the Speed-Dependent Current Limitation for Motors with Commutation Transition
358
-
Setting of Speed-Dependent Current Limitation for Motors Without Commutation Transition
359
-
-
Automatic Restart
360
-
Direction of Rotation Reversal Using Field Reversal
361
-
Braking with Field Reversal
362
-
Status Description of some Bits of Status Word ZSW1
364
-
Fault Messages
365
-
List of Fault Messages
366
-
Interface Error
369
-
External Faults
371
-
Fault Messages from Motor Sensors
372
-
External Faults
373
-
Start-Up Faults
376
-
External Faults
381
-
Hardware Faults
382
-
Internal Faults
383
-
Communication Errors with Supplementary Boards
386
-
Faults Messages from Supplementary Boards
387
-
Alarms
388
-
Connector List
541
-
Binector List
562
-
Spare Parts
595
-
Replacement of Components
597
-
Replacement of Pcbs
601
-
Replacement of Fuses and Thyristor Assemblies on Converters of 1500A and above
602
-
Europe
603
-
-
15 Simovis
605
-
Scope of Supply
605
-
Further Information
606
-
Advertisement
Advertisement
Related Products
-
Siemens SIMOREG DC Master 6RA7028-6DS22
-
Siemens SIMOREG DC Master 6RA7025-6FS22
-
Siemens SIMOREG DC Master 6RA7028-6FS22
-
Siemens SIMOREG DC Master 6RA7025-6GS22
-
Siemens SIMOREG DC Master 6RA7075-6DS22
-
Siemens SIMOREG DC Master 6RA7078-6DS22
-
Siemens SIMOREG DC Master 6RA7087-6DS22
-
Siemens SIMOREG DC Master 6RA7095-4DS22
-
Siemens SIMOREG DC Master 6RA7031-6FS22
-
Siemens SIMOREG DC Master 6RA7087-6FS22
Siemens Categories
Controller
Control Unit
Industrial Equipment
Washer
Switch
More Siemens Manuals
SIMOREG DC MASTER — семейство цифровых приводов постоянного тока. Имеет подходящие типы как для сложных приводных задач, так и для стандартных решений. Применяется для двигателей постоянного тока, имеющих номинальный ток обмотки якоря от 15 до 2000А и может быть расширен до 10000 А (путем параллельного соединения преобразователей, максимально — 5 блоков). Приводы высоко динамичны: время возбуждения либо время нарастания вращающего момента находится в пределах до 10 мс.
Настройка привода постоянного тока производится через устройство параметризации. Установка параметров может также производиться с помощью персонального компьютера с использованием удобных меню — для быстрого ввода в эксплуатацию, а также для простой визуализации при исполнении SIMOVIS. SIMOREG DC MASTER имеет открытую и стандартизированную систему полевых шин PROFIBUS-DP с использованием коммуникационного модуля CBP2, подключение к персональному компьютеру через интерфейс RS232 и коммуникацию по типу «узел — узел». При этом PROFIBUS-DP-центральное средство коммуникации между средствами автоматизации. Модуль CBP2 устанавливается непосредственно в электронный бокс SIMOREG DC MASTER.
Основные особенности SIMOREG DC MASTER
- высокая степень интеграции в любой автоматизированной среде;
- возможность расширения благодаря модульной концепции;
- решение задач от стандартных до экстремальных;
- избыточные характеристики привода до 12000А благодаря интеллектуальному параллельному решению; Функция управление моментом двигателя
- номинальные напряжения от 400 до 830 В;
- краткий и простой запуск в эксплуатацию благодаря полностью электронному параметрированию всех натроек;
- единая философия управления;
Номинальный ток, напряжение питания SIMOREG DC MASTER
Номинальный ток двигателя 15-2000А (10000 А при параллельном подключении- максимально 5 блоков)
Напряжения питающей сети 50/60 Гц
- 3 AC 400 В/575 В
- 3 AC 400 В/575 В/690 В
- 3 AC 400 В/575 В/690 В/(830 В)
Охлаждение SIMOREG DC MASTER
- Вентиляторы охлаждения
- Радиатор
Порты связи SIMOREG DC MASTER
- RS 232
- RS 485
Входывыходы управления SIMOREG DC MASTER
Клеммы на микропроцессорном модуле (главный модуль электроники)
- 2 аналоговых входа через дифф. усилитель, разрешающая способность 10 до ±14 бит
- 0 … ±10 В, 0 … ±20 мA, 4 … 20 мA
- аналоговый вход для датчика температуры двигателя через PTC или KTY84
- аналоговый выход истинного времени для текущего значения тока относительно массы, 5В для номинального тока прибора, макс. 2 мA
- 2 аналоговых выхода относительно массы, 0 … ±10 В, разрешение ± 11-бит, макс. 2 мA
- 4 двоичных входа отн. массы, 2 с функциями расширения
- 2 двоичных выхода отн. массы, открытый эмиттер P24, нагр. способность100 мА
Клеммы на опциональном модуле расширения клемм SIMOREG DC MASTER
- 4 двоичных входа выбора через оптрон, используемые также как интерфейс к двигателю
- 4 двоичных входы выбора относительно массы
- 2 аналоговых входа отн. массы, разрешение ±10 бит
- 2 один аналоговый вход для оценки температуры двигателя через PTC или KTY84
- 2 двоичных выхода P24, открытый эмиттер, относительно массы,
нагруз. способность 100 мА
- 2 аналоговых выхода относительно массы, ±10 В, нагрузочная способность 2 мА, разрешение ±11 бит
ПИПИД-регуляторы SIMOREG DC MASTER
- ПИ- регулятор скорости
- ПИ — регулятор тока
- ПИ-регулятор ЭДС
- ПИ-регулятор тока возбуждения
Доступные опции SIMOREG DC MASTER
Опции основного прибора
- Модуль расширения клемм CUD2
Интеграция электронных опций SIMOREG DC MASTER
- Адаптер монтажной шины LBA
- Модуль адаптера ADB
Расширения клемм SIMOREG DC MASTER
- Опциональный модуль SPB для импульсного датчика
- Модуль расширения клемм EB1
- Интерфейсные модули SCI1 и SCI2
Технологические модули SIMOREG DC MASTER
- Технологический модуль Т400
- Технологический модуль Т100
Коммуникации SIMOREG
- Коммуникационный модуль SIMOLINK SLB
- Коммуникационный модуль CBP2 для PROFIBUS-DP
- Коммуникационный модуль СВС для CAN
- Коммуникационный модуль CBD DeviceNet
- Интерфейсный модуль SCB1
Управление и наблюдение SIMOREG DC MASTER
- Комфортная панель управления OP1S
- DriveMonitor
- Инжиниринговый пакет Drive ES
- Силовые опции
- Выпрямительный модуль SIMOREG 6RL70
В зависимости от номинального тока существуют следующие модели SIMOREG DC MASTER:
Реверсивные приводы постоянного тока:
6RA7013-6DV62-03 AC 400 V, 15 A
6RA7018-6DV62-03 AC 400 V, 30 A
6RA7025-6DV62-03 AC 400 V, 60 A
6RA7028-6DV62-03 AC 400 V, 90 A
6RA7031-6DV62-03 AC 400 V, 125 A
6RA7075-6DV62-03 AC 400 V, 210 A
6RA7078-6DV62-03 AC 400 V, 280 A
6RA7081-6DV62-03 AC 400 V, 400 A
6RA7085-6DV62-03 AC 400 V, 600 A
6RA7087-6DV62-03 AC 400 V, 850 A
6RA7091-6DV62-03 AC 400 V, 1200 A
6RA7093-4DV62-03 AC 400 V, 1600 A
6RA7095-4DV62-03 AC 400 V, 2000 A
6RA7098-4DV62-03 AC 400 V, 3000 A
Нереверсивные приводы постоянного тока:
6RA7018-6DS22-0 AC 400 V, 30 A
6RA7025-6DS22-0 AC 400 V, 60 A
6RA7028-6DS22-0 AC 400 V, 90 A
6RA7031-6DS22-0 AC 400 V, 125 A
6RA7075-6DS22-0 AC 400 V, 210 A
6RA7078-6DS22-0 AC 400 V, 280 A
6RA7081-6DS22-0 AC 400 V, 400 A
6RA7085-6DS22-0 AC 400 V, 600 A
6RA7087-6DS22-0 AC 400 V, 850 A
6RA7091-6DS22-0 AC 400 V, 1200 A
6RA7093-4DS22-0 AC 400 V, 1600 A
6RA7095-4DS22-0 AC 400 V, 2000 A
6RA7098-4DS22-0 AC 400 V, 3000 A