Thank you for purchasing EM303A series inverter.

Document No.: 31010005

Issue Date: 06/06/2013

EM303A is a general purpose inverter (Speed Sensorless Vector Control). It helps an

induction motor to achieve not only the speed regulation standard of a DC motor, but also

the control ability of a torque motor, and the motion control system is optimized with

quick response, precise control and system stability.

The updates of EM303A:

1. Support Modbus RTU standard communication protocol.

2. Support RS485 master-slave communication control mode, numeric synchronized

control achieved.

3. Numeric input terminals support F/R logic control, delay input control, and etc.

4. Numeric output terminals support PWL/pulse output, F/R logic output and delay output,

and etc.

5. Analog input signals VS/IS/VF/IF can be programmed as numeric inputs, numeric

terminals expansion control achieved.

6. With filtering, analog input signals VP/VS/IS/VF/IF can actively avoid analog signals

interference and drift.

7. User can easily define the display of function code menus.

8. Run, stop and parameters setting status can program the displayed parameters

independently.

It is the duty of any user to perform the appropriate, correct installation or configuration

of the optional parameters of the devices. Neither SINEE nor its distributors shall be

responsible or liable for misuse of the information contained herein or mismatching the

inverter with the motor.

In the interests of commitment to a policy of continuous development and improvement,

SINEE reserves the right to update the specification of the product or its performance, or

the content herein without notice.

Preface

1

loading

Summary of Contents for Sinee EM303A-1R1-1CB

  1. Manuals
  2. Brands
  3. Sinee Manuals
  4. Inverter
  5. EM303A-7R5G/9R0P-3CB

Manuals and User Guides for Sinee EM303A-7R5G/9R0P-3CB. We have 1 Sinee EM303A-7R5G/9R0P-3CB manual available for free PDF download: User Manual

Detail Specifications:

1338/1338382-em303a1r11cb.pdf file (02 Jan 2023)

Accompanying Data:

Sinee EM303A-1R1-1CB Inverter PDF Operation & User’s Manual (Updated: Monday 2nd of January 2023 07:48:07 PM)

Rating: 4.3 (rated by 11 users)

Compatible devices: A90 Series, EM330D-3R0-3B, M175-24-240-S, LMC SUN Series, AC Master 700, R-VOLT, ZR-SWITCH-RC, FX-SG3800.

Recommended Documentation:

Text Version of Operation & User’s Manual

(Ocr-Read Summary of Contents, UPD: 02 January 2023)

  • 22, User Manual EM303A General Purpose Inverter 22 2.5 Disassembly and Assembly of Keypad Under general circumstances, it is unnecessary to disassemble the keypad, and just remove the cover to assemble and wire. On special occasions, disassemble the keypad by following steps. z Remove the front cover: For EM303A-7R5 or below, push the cover vertically from the bottom with two hands, a…

  • 46, Sinee EM303A-1R1-1CB User Manual EM303A General Purpose Inverter 46 6.2 Parameters Section 1 General Parameters 6.2.1 Group F0: General Parameters No. Function Range Unit Default Type F0-00 (L) Speed Reference Input Monitoring Torque Reference Input Monitoring Frequency: 0.00~Fmax/0.0~Fmax Speed: 0~F*Customer defined scaling Torque input: 0.00~Limited torque Hz rpm % 0.00/…

  • 92, User Manual EM303A General Purpose Inverter 92 control mode is in terminal control mode, when terminal X1 is on, inverter runs. Xi=0 No function This function can be used to block the terminal when its hardware breaks down. Xi=1 RUN When start/stop control mode is terminal control (F0-04=1), if the function terminal is on, the inverter will run as per the setting …

  • 70, User Manual EM303A General Purpose Inverter 70 FA-06 Regular Torque Options Special Torque Options Auxiliary Torque Options Ones place: Regular torque options 0: Regular torque input 1: VS* Regular torque input 2: VF* Regular torque input 3: IS* Regular torque input 4: IF* Regular torque input Tens place: Special torque options 0: Special torque input 1: VS*…

  • 38, User Manual EM303A General Purpose Inverter 38 3.4 Extending Keypad Wire Disassemble the keypad of EM303A as per the method shown in Figure 2-3, connect to an extension wire, and then assemble the keypad in a proper place and take it as a control panel. Disassemble the keypad and connect extension keypad wire by following the method as shown in Figure 3-18. If the extension w…

  • 114, User Manual EM303A General Purpose Inverter 114 ★ Customer can set the current limit based on actual needs to protect motor or meet the working requirements. F5-09 and F5-10 limit the torque limiting current in power-driven and brake status respectively. See Figure 7-18. 1. If the setting torque current and rotation of motor are in the same direction, t…

  • 27, User Manual EM303A General Purpose Inverter 27 z If single MCCB is shared by two or more inverters or other devices, the contact of fault output relay shall be connected to power contactor coil, so that the power supply will be turned off by the fault signals, as shown in Figure 3-4. Figure 3-4 Connecting to Input Circuit Breaker Install…

  • 137, User Manual EM303A General Purpose Inverter 137 12.4.4 CRC Parity Sending equipment calculates CRC parity value first, and then attaches it to the sending message. Upon receipt of the message, receiving equipment will calculate CRC parity value again, and compare the operating result with received CRC parity value. If the two values are different, it indicates that th…

  • 79, User Manual EM303A General Purpose Inverter 79 No. Function Range Unit Default Type F0-04 Start/Stop Control Options 0: Keypad 1: Terminal 2: RS485 0 〇 F0-05 Terminal Start/Stop Control Options 0:RUN-Run, F/R-Forward/Reverse 1: RUN- Forward,F/R- Reverse 2: RUN-NO forward, Xi-NC stop, F/R-NO reverse 3: RUN-NO run, Xi-NC stop, F/R- Forward/Rev…

  • 6, Sinee EM303A-1R1-1CB User Manual EM303A General Purpose Inverter 6 CONTENTS SUPPLEMENT FOR EM303A-XXX-1C, EM303A-XXX-2C ……….. 8 1. OVERVIEW ………………………………………… 9 1.1 EM303A MODEL LIST AND TECHNICAL SPECIFICATIONS ………. 9 1.2 BASIC FUNCTIONS OF EM303A ………………………. 11 1.3 EM303A OPERATION STATUS DEFINITION ……………….. 13 1.4 EM…

  • 60, Sinee EM303A-1R1-1CB User Manual EM303A General Purpose Inverter 60 E0-11 DC Bus Voltage at Fault XXXX V 0.0 ◇ E0-12 Running Direction at Fault FOr:Forward, rEV:Reverse 0 ◇ E0-13 Running Status at Fault ACC:Acceleration CON:Constant speed dEC:Deceleration 0 ◇ E0-14 Stalling Status at Fault 0:Normal UL:Overvoltage stall CL:Overcurrent stall 0 ◇ E0-15 W…

Recommended Instructions:

F-ADT-PIR-1, Car and Family GPS Locator, XT4862, OR50, M-10X

  • AC Generator3600 WattModel No.580.323610Part No. 198138GS Draft C (05/08/2006)GeneratorCustomer Helpline1-800-222-3136Operator’s Manual• Safety• Assembly• Operation• Maintenance• Parts• Español, p. 36HOURS: Mon. — Fri. 8 a.m. to 5 p.m. (CT)Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.Visit our Craftsman website: www.craftsman.comADVERTENCIAAntes de u …

    580.323610 60

  • E6581179②- 1 -TOSVERT VF-A7/P7Instruction Manual for Parametersf480 and f481Thank you for purchasing the Toshiba industrial inverter «TOSVERT VF-A7/P7».This manual describes the functions of the f480 and f481 parameters for the inverter TOSVERT VF-A7/P7.TitleCommunicationNo.Function Adjustment rangeMinimumsetting unit(Panel/Communication)Defaultset …

    TOSVERT VF-A7 2

  • SERVICE MANUAL 6.5 MCG 60HZ . 5.2 MCG 50HZ 5.0 MCG 60HZ 4.2 MCG 50HZ /tlu/ti-port ELECTRONIC FUEL INJECTION MARINE GASOLINE GENERATOR Single Phase PUBLICATION. NO: 055743! REVISION 1 . NOVEMBER. 2017. …

    6.5 MCG 60HZ 90

Additional Information:

Operating Impressions, Questions and Answers:

Sinee Manuals and Guides:

The main types of Sinee EM303A-1R1-1CB instructions: user guide — rules of useing and characteristics, service manual — repair, diagnostics, maintenance, operation manual — description of the main functions of Sinee EM303A-1R1-1CB equipment, etc.

Most of the instructions, that you can see on the site are uploaded by our users. If you have available a manual or document for Sinee EM303A-1R1-1CB, which is currently not on the site or present in a different language version, we ask you to upload your document on website, using the «uploading form» available to all registered users.

Download or browse on-line these Operation & User’s Manual for Sinee EM303A-1R1-1CB Inverter.

Summary of Contents:

[Page 1] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 1 Preface Thank you for purchasing EM303A series inverter. Document No.: 31010005 Issue Date: 06/06/2013 EM303A is a general purpose inverter (Speed Sensorless Vector Control). It help…

[Page 2] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 2 Safety Information The addition of this symbol to a Danger or Warning safety label indicates that an electrical hazard exists, which will result in personal injury if the …

[Page 3] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 3 z Wiring Danger 1. Always turn off the input power supply before wiring. Otherwise, an electric shock or fire may occur. 2. Wiring must be performed by authorized and qualifi…

[Page 4] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 4 z Trial Operation Danger 1. Only after the front cover is installed, power can be turned on. Never take off the front cover when power is on. An electric shock …

[Page 5] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 5 Caution 1. CMOS ICs are installed on keypad, control circuit board and drive circuit board respectively. Handle those parts and CMOS ICs carefully. The CMOS IC …

[Page 6] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 6 CONTENTS SUPPLEMENT FOR EM303A-XXX-1C, EM303A-XXX-2C ……….. 8  1. OVERVIEW ………………………………………… 9 1.1 EM303A MODEL LIST AND TECHNICAL SPECIFICATIONS …….

[Page 7] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 7 7.2 GROUP F1: MOTOR PARAMETERS …………………….. 88 7.3 GROUP F2: INPUT/OUTPUT TERMINAL PARAMETERS ………… 91 7.4 GROUP F3: PRESET SPEED PARAMETERS ………………….

[Page 8] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 8 PBWUVL2L1 Supplement for EM303A-XXX-1C, EM303A-XXX-2C Except input voltage, applicable motor and power wire size, EM303A-XXX-1C and EM303A-XXX-2C are the same as EM303A-XXX-3C in terms of insta…

[Page 9] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 9 1. Overview 1.1 EM303A Model List and Technical Specifications z Rated voltage: 3-phase, AC380V/415V z Applicable motor: 3-phase induction motor, power range: 0.75~400kW. Rated voltage: AC3…

[Page 10] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 10 1.1.2 EM303A Technical Specifications Table 1-2 EM303A Technical specifications Items S p ecifications Input Rated Voltage 3-phase AC380V~415V±20%, 50~60Hz±5%, voltage imbalance ra…

[Page 11] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 11 1.2 Basic Functions of EM303A 1.2.1 Process PID Control 2 process PID control modes: Speed process PID control and torque process PID control. When output of process PID control is taken as…

[Page 12] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 12 1.2.7 Low Noise Design Due to the high frequency harmonic wave with the output of inverter, the motor generates the electromagnetic noise inevitably. Usually, electromagnetic noise can be lowe…

[Page 13] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 13 interval. Meanwhile, if speed search is active, inverter will automatically detect motor speed and direction to make it return the setting input frequency smoothly. 1.2.15 Multi-function Numer…

[Page 14] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 14 with the requirements of setting input. z JOG running status: Set by keypad, external terminal or RS485 to make motor run per JOG input speed. z JOG stop status: Refer to the process that th…

[Page 15] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 15 Figure 1-1 Speed Setting Modes

[Page 16] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 16 Figure 1-2 Torque Input Modes

[Page 17] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 17 1.3.4 Operation Control Mode of Inverter The operation control mode of inverter refers to the action conditions when inverter enters operation status, which includes 3 modes as controlled by ke…

[Page 18] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 18 2 Installation 2.1 Verifying Product Refer to Table 2-1, and check and verify the EM303A. Table 2-1 Check List Item Action If the products are identical to the purchase order. Check th…

[Page 19] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 19 2.2 Overall and Installation Dimensions Classified to 10 sizes for total 30 models of EM303A, installation dimensions as shown in Figure 2-1 and Table 2-2. The keypad can be installed on the…

[Page 20] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 20 Table 2-2 Overall and Installation Dimensions of EM303A Model No. W W1 H H1 H2 D D1 D2 d Frame EM303A-0R7G/1R1P-3CB 140 125 220 205 — 152 120 161 6 (b) EM303A-1R1G/1R5P-3CB EM303A-1R…

[Page 21] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 21 2.3 Considerations of Installation Site 2.3.1 Installation Site Considerations for installation site: z Good ventilation indoor z Ambient temperature: -10°C~+40°C z No high t…

[Page 22] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 22 2.5 Disassembly and Assembly of Keypad Under general circumstances, it is unnecessary to disassemble the keypad, and just remove the cover to assemble and wire. On special occasions, disassemb…

[Page 23] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 23 Figure 2-4 Disassemble the Keypad Figure 2-5 Assemble the Keypad

[Page 24] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 24 3 Wiring 3.1 Connections to Peripherals Connections between EM303A and its peripherals are shown in Figure 3-1 Figure 3-1 EM303A Peripherals Connections

[Page 25] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 25 3.2 Wiring Main Circuit Terminals 3.2.1 Main Circuit Terminal Block See Figure 3-2 for main circuit terminal block. PBWUVSTR (a) Main Circuit Terminal Block of EM303A-015 or bel…

[Page 26] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 26 3.2.2 Main Circuit Terminal Functions The main circuit terminal functions of EM303A are listed in Table 3-1. Wire the terminals correctly as per corresponding function. Table 3-1 Main Circu…

[Page 27] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 27 z If single MCCB is shared by two or more inverters or other devices, the contact of fault output relay shall be connected to power contactor coil, so that the power supply will be turned off b…

[Page 28] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 28 Installing a Surge Absorber Install a surge absorber for inductive loads (electromagnetic contactors, solenoid valves, solenoid coils, or electromagnetic circuit breakers) nearby the inverter….

[Page 29] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 29 Never Connecting Power Supply Cable to Output Terminals Never connect power supply cable to output terminals. If power is input to the output terminals, the inverter would be damaged. Neve…

[Page 30] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 30 The distance between output cables and signal line should>30cm, and the inductive interference will be reduced considerably, as shown in Figure 3-8. Figure 3-8 Countermeasures Against Indu…

[Page 31] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 31 3.2.6 Main Circuit Cable and Terminal Screw Size See Table 3-3 for the specifications of main circuit cable and terminal screw. Table 3-3 Main Circuit Cable and Terminal Screw Specificat…

[Page 32] Sinee EM303A-1R1-1CB

User M EM3 0 3. 2 3. 2 3.3 W 3. 3 T z z z z z z z S M anual 3A General Purpose I 2 .7 Ground Wiring z Make sure the gr o z Do not share the g z The size of gro u appliances, and t h z Do not form the …

[Page 33] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 33 3.3.2 Function and Wiring of Control Circuit Terminals Function of control circuit terminals as shown in Table 3-4 Table 3-4 Function of Control Circuit Terminals Mode Terminal Terminal Nam…

[Page 34] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 34 3.3.2.1 Wiring the Analog Input Terminals Wiring terminals VS and VF through analog voltage signal: When analog voltage input signal is as the external power supply, wire terminals VS a…

[Page 35] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 35 3.3.2.3 Wiring Relay Output Terminal The surge voltage absorbing circuit should be installed for inductive load like relay or contactor. For instance: RC absorbing circuit (please note that th…

[Page 36] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 36 3.3.2.6 Wiring Communication Terminal Terminals A+ and A- are the RS485 communication interfaces of the inverter. The control network between PC or PLC and inverter can be achieved through…

[Page 37] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 37 3.3.5 Standard Control Circuit Wiring See Figure 3-17 for standard control circuit wiring of EM303A. Figure 3-17 Standard Control Circuit Wiring of EM303A Remarks: EM303A-055 or above: …

[Page 38] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 38 3.4 Extending Keypad Wire Disassemble the keypad of EM303A as per the method shown in Figure 2-3, connect to an extension wire, and then assemble the keypad in a proper place and take it as …

[Page 39] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 39 4 Keypad Operation 4.1 Type and Function of Keypad EM303A keypad consists of 5-bit LED display, operation buttons and analog potentiometer. As shown in Figure 4-1. User can perform function…

[Page 40] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 40 UP Select function parameter, menu or increase the value of setting parameters, and increase the present effective reference numeric input data. DOWN Select function parameter, menu o…

[Page 41] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 41 5 Trial Operation 5.1 Trial Operation Procedures Table 5-1 Procedures of Trial Operation Procedure Working Scope Installation Check inverter’s rated power, and install the inve…

[Page 42] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 42 Setting Operation Control Parameter General Parameter Set rotational direction, F/R control, acceleration/deceleration time, control mode, star/stop mode, and input mode directly based on …

[Page 43] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 43 5.2 Trial Operation Precautions 5.2.1 Turn off the Power Checks before power-off: z Voltage of power supply:3-phase 380V/415V, 50Hz z Connect the input power supply cable to th…

[Page 44] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 44 z Operation Status Monitoring 1. Change input frequency or rotation direction, and monitor if there is vibration or unexpected noise with the motor or not. 2. Check if inverter runs stably….

[Page 45] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 45 6 Parameter Tables 6.1 Format of Parameter Tables 17 groups of parameter of EM303A: F0, F1, F2, F3, F4, F5, F6, F7, F8, F9, FA, Fb, FC, Fd, FE, C0, and E0, 32 items in each group. …

[Page 46] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 46 6.2 Parameters Section 1 General Parameters 6.2.1 Group F0: General Parameters No. Function Range Unit Default Type F0-00 (L) Speed Reference Input Monitoring Torque Reference Input…

[Page 47] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 47 Time F0-13 Jog Deceleration Time 0.00~600.00 S/min 15.00 ● F0-14 Carrier Frequency 1.000~16.000 kHz 2.000 ● F0-15 Torque Boost 0: Automatic torque boost 1~10: Fixed torque boost …

[Page 48] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 48 6.2.2 Group F1: Motor Parameters No. Function Range Unit Default Type F1-00 Motor Type 0: AC induction motor 1: Not used 0 〇 F1-01 Motor Rated Power 0.40~480.00 kW XXXX 〇 F1-0…

[Page 49] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 49 6.2.3 Group F2: Input/Output Terminal Parameters No. Function Range Unit Default Type F2-00 Multi-function Input Terminal X1-RUN See Table 6-1 Functions of Numeric Multi-function Inp…

[Page 50] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 50 Table 6-1 Functions of Numeric Multi-function Input Terminals No. Function No. Function 0 Disabled 28 Switching Speed Input Setting to Auxiliary Speed Setting 1 RUN 29 Switching Prima…

[Page 51] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 51 Table 6-2 Functions of Numeric Multi-function Output Terminals No. Function No. Function 0 Inverter Runs(Enabled at running) 17 Overload Alarming Output 1 Frequency Reach Signal FAR (E…

[Page 52] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 52 Table 6-3 Analog Outputs Full Scales No. Signal Full Scale (100.0%) No. Signal Full Scale (100.0%) 0 Output Frequency Fmax 11 IS 20mA 1 Input Frequency Fmax 12 IF 20mA 2 Synchrono…

[Page 53] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 53 6.2.4 Group F3: Preset Speed Operation Parameters No. Function Range Unit Default Type F3-00 Preset Speed 1 0.00~Fmax/0.0~Fmax Hz 0.00 ● F3-01 Preset Speed 2 0.00~Fmax/0.0~Fmax Hz…

[Page 54] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 54 6.2.5 Group F4: General Parameters of PID No. Function Range Unit Default Type F 4-00 PID Regular Setting Mode 0: Numeric PID Setting 1: VS 2: IS 3: VF 4: IF 5: VP 0 〇 …

[Page 55] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 55 F 4-16 LCD Language Options 0: Chinese, 1: English 0 〇 F 4-17 Not Used F 4-18 If Parameters Change with inverter’s working status 0: Unchanged 1: Changed 1 …

[Page 56] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 56 6.2.6 Group F5: General Parameters of Vector Control No. Function Range Unit Default Type F5-00 Speed Proportion Gain ASR_P1 0.00~100.00 % 15.00 ● F5-01 Speed Integration Time ASR…

[Page 57] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 57 F5-13 Torque Direction 0: Positive Torque 1:Negative Torque 0 ● F5-14 Upper Limit Frequency Limiting of Torque Control 0: Upper Limit Frequency 1: VS* Upper Limit Frequency 2 : IS*U…

[Page 58] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 58 6.2.7 Group C0: Monitoring Parameters No. Function Range Unit Default Type C0-00 Output Frequency 0.00~Fup/0.0~Fup Hz 512 × C0-01 C0-02 Output Frequency Torque Upper Limit Frequ…

[Page 59] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 59 6.2.8 Group E0: Fault Parameters No. Function Trip and Parameter Description Unit Default Type E0-00 Fault Trips 00: No fault SC: Short circuit HOC: Instantaneous overcurrent HOU: Inst…

[Page 60] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 60 E0-11 DC Bus Voltage at Fault XXXX V 0.0 ◇ E0-12 Running Direction at Fault FOr:Forward, rEV:Reverse 0 ◇ E0-13 Running Status at Fault ACC:Acceleration CON:Constant s…

[Page 61] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 61 Section 2 Advanced Parameters 6.2.9 Group F6: Program Operation Control (PLC) No. Function Range Unit Default Type F6-00 Program Operation Mode Ones place: Options of speed program oper…

[Page 62] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 62 F6-08 Operation Time T1 0.0~6000.0 S/min 30.0 ● F6-09 Operation Time T2 0.0~6000.0 S/min 30.0 ● F6-10 Operation Time T3 0.0~6000.0 S/min 30.0 ● F6-11 Operation Time T4 0.0~600…

[Page 63] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 63 6.2.10 Group F7: Advanced Parameters of Operation No. Function Ran g e Unit Default T yp e F7-00 Overload Alarm Control Ones place: Overload alarm detection 0: Detect all the time …

[Page 64] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 64 6.2.11 Group F8: Input/Output Bias No. Function Range Unit Default Type F8-00 Voltage /Current Input Options Ones place: VS voltage options 0: 0~10V 1: 2~10V Tens place: VF vol…

[Page 65] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 65 F8-02 VP Bias Options 0: Input / output bias 0 1: Input / output bias 1 2: Input / output bias 2 2 〇 F8-03 VP Filter Time 0.00~60.00 S 0.10 ● F8-04 VS Filter Time 0.00~60.00 …

[Page 66] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 66 6.2.12 Group F9: Speed Setting Options No. Function Range Unit Default Type F9-00 Function of STOP Button 0: Stop in keypad start/stop mode 1: Stop in all start/stop modes 2: Stop in …

[Page 67] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 67 1: Jog numeric speed setting mode + primary speed setting mode 2:Jog numeric speed setting mode + auxiliary speed setting mode Hundreds place: Auxiliary speed setting direction 0: Primar…

[Page 68] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 68 Thousands place: Process PID Output mode options 0: PID output 1: VS* PID output 2: VF* PID output 3: IS* PID output 4: IF* PID output 5: Auxiliary frequency* PID output F9-09 Detecti…

[Page 69] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 69 6.2.13 Group FA: Advanced Parameters of Vector Control No. Function Range Unit Default Type FA-00 Torque Current Setting Mode Ones place: Primary torque setting mode 0: Regular …

[Page 70] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 70 FA-06 Regular Torque Options Special Torque Options Auxiliary Torque Options Ones place: Regular torque options 0: Regular torque input 1: VS* Regular torque input 2: VF* Regular torque in…

[Page 71] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 71 6.2.14 Group Fb: Advanced Parameters of PID No. Function Ran g e Unit Default T yp e F b -00 PID Settin g Mode 0: General m ode 1: S p ecial m ode 0 〇 Fb-01 Special …

[Page 72] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 72 6.2.15 Group FC: Operation Control Parameters No. Function Range Unit Default Type FC-00 Acceleration/ Deceleration Mode 0:Linear Mode 1:Not Used 0 〇 FC-01~FC-02 Not Used …

[Page 73] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 73 Stall Control 0:Dynamic brake+Stall protection 1:Dynamic brake Tens place: Dynamic brake options 0:Enabled at power-on 1:Enabled at running 2:Enabled at deceleration Hundred…

[Page 74] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 74 6.2.16 Group Fd: Auxiliary Parameters No. Function Range Unit Default Type Fd-00 Frequency Base Fbase:20.00~600.00/20.0~6000.0 Hz 50.00 〇 Fd-01 Voltage 1 0.00~100.00 % 1.00 ● …

[Page 75] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 75 6.2.17 Group FE: Terminal Function User Defined Parameters No. Function Range Unit Default Type FE-00 Numeric Input Filter Times 0~100; 1=0.50mS 5 〇 FE-01 Terminal Input Posi…

[Page 76] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 76 Hundreds place: R1 output type 0: Level signal 1: Pulse signal FE-07 Terminal Output Logic Control Ones place: Y1 output logic control 0: Y1 is on in positive logic 1: Y1 is off at neg…

[Page 77] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 77 7 Parameter Description 7.1 Group F0: General Parameters No. Function Range Unit Default Type F0-00 Speed Reference Input Monitoring Torque Reference Input Monitoring Frequency:0.00…

[Page 78] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 78 Remarks: This mode is only applied to speed control mode, not for torque control. ▲ F0-02=3 SVC1: Vector control mode 1 without speed feedback (torque control). It not only estimates s…

[Page 79] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 79 No. Function Range Unit Default Type F0-04 Start/Stop Control Options 0: Keypad 1: Terminal 2: RS485 0 〇 F0-05 Terminal Start/Stop Control Options 0:RUN-Run, F/R-Forward/Rever…

[Page 80] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 80 Two terminal control modes: 2-wire sequence and 3-wire sequence 2-wire sequence: F0-05=0 ON/OFF of terminal RUN controls start/stop of inverter, and OFF/ON of terminal F/R controls forward…

[Page 81] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 81 3-wire sequence: F0-05=2 RUN is NO forward running button, F/R is NO reverse running button, Xi is NC stop button, all of them will be on at pulse edge. In running status, press Xi button…

[Page 82] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 82 Use the buttons and switches correctly by following the mode illustrated in the above diagrams of EM303A 3-wire sequences, otherwise, malfunctions may occur. No. Function Range Unit D…

[Page 83] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 83 No. Function Range Unit Default Type F0-07 Primary Numeric Frequency Setting 0.00~Fmax/0.0~Fmax Hz 0.00 ● F0-08 Motor Running Direction 0:Forward 1:Reverse 0 ● F0-07 T…

[Page 84] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 84 In JOG running mode, inverter runs at the frequency set by F0-11, the acceleration/deceleration time taken for running to Fmax is set by F0-12/F0-13. ★ Jog acceleration time is the time tak…

[Page 85] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 85 No. Function Range Unit Default Type F0-16 Maximum Frequency Fmax: 20.00~600.00/20.0~6000.0 Hz 50.00 〇 F0-17 Upper Limit Frequency Fup: Fdown ~Fmax Hz 50.00 〇 F0-18 Lo…

[Page 86] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 86 Before inverter starts, the motor may be running at low speed or in opposite rotation status. If inverter starts immediately at mean time, overcurrent may occur. In order to avoid such fault, …

[Page 87] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 87 No. Function Range Unit Default Type F0-24 Forward/Reverse Control 0: Forward/Reverse Permitted 1: Forward/Reverse Prohibited 0 〇 F0-25 F/R Deadband 0.00~600.00 S 0.00 ● Pe…

[Page 88] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 88 No. Function Range Unit Default Type F0-28 Default Control 0: Disabled 1: Defaults Reset 0 〇 F0-29 Parameter Setting Control 0: Parameter setting permitted 1: Parameter lock 0 2: …

[Page 89] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 89 F1-03 Motor Rated Current 0.1~1500.0 A XXXX 〇 F1-04 Motor Rated Frequency 20.00~600.00 Hz XXXX 〇 F1-05 Motor Rated Speed 1~30000 rpm XXXX 〇 F1-06 Motor Wiring Mode 0:Y W…

[Page 90] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 90 z After parameters autotuning completed, F9-15=0 will be set automatically. z When slip compensation is active, autotune motor parameter first, so that the motor will obtain the optimum perf…

[Page 91] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 91 sent by master inverter received through F0-07 or F9-06 will be the setting numeric frequency of slave inverter. Remarks: See the Appendix for EM303A ModBus communication protocol and exam…

[Page 92] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 92 control mode is in terminal control mode, when terminal X1 is on, inverter runs. Xi=0 No function This function can be used to block the terminal when its hardware breaks down. Xi=1 RUN Wh…

[Page 93] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 93 Xi=15 UP/DOWN clearing If taking stepping mode in operation, UP or DOWN is enabled and UP/DOWN clearing is active, input frequency returns the value of F0-07. Xi=16 Acceleration/Decele…

[Page 94] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 94 selection. Xi=24 Switch input control mode to speed control mode When the terminal is on, the present input control mode is switched to the speed control mode, and its function is equivalent …

[Page 95] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 95 In torque control mode, if the function terminal is on, then the special torque setting is switched to auxiliary torque setting mode. Its function is equivalent to setting the one’s placeof …

[Page 96] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 96 ON ON OFF Preset PID Setting 6 Fb-25 ON ON ON Preset PID Setting 7 Fb-26 Xi=41 Preset torque current terminal 1 Xi=42 Preset torque current terminal 2 Xi=43 Preset torque current ter…

[Page 97] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 97 Wobbulation operation mode starts. Xi=48 Not used Xi=49 Program operation reset When program operation (PLC) is active, if the input signal of this terminal is on, and then program o…

[Page 98] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 98 Relay output is provided by the internal relay of inverter. Relay has 1 set of NO contacts and 1 set of NC contacts. When selected program code is disabled, EB-EC is NC, and EA-EC is NO. Whe…

[Page 99] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 99 7.4 Group F3: Preset Speed Parameters No. Function Range Unit Default Type F3-00 Preset Speed 1 0.00~Fmax/0.0~Fmax Hz 0.00 ● F3-01 Preset Speed 2 0.00~Fmax/0.0~Fmax Hz 5.00 �…

[Page 100] Sinee EM303A-1R1-1CB

User Manual EM303A General Purpose Inverter 100 9 ON OFF OFF OFF Preset Speed 8 F3-07 10 ON OFF OFF ON Preset Speed 9 F3-08 11 ON OFF ON OFF Preset Speed 10 F3-09 12 ON OFF ON ON Preset Speed 11 F3-10 13 ON ON …