-
Contents
-
Table of Contents
-
Bookmarks
Quick Links
SIWAREX WP321
Weighing systems
Electronic weighing system
SIWAREX WP321
Manual
07/2014
A5E33715669A-02
___________________
Introduction
___________________
Safety notes
___________________
Description
___________________
Application planning
___________________
Mounting
___________________
Connection
___________________
Commissioning
___________________
Scale parameters and
functions
___________________
Messages
___________________
Command lists
___________________
Communication in SIMATIC
S7-300/1200/1500
___________________
Technical data
___________________
Accessories
___________________
Appendix
___________________
ESD guidelines
___________________
List of abbreviations
1
2
3
4
5
6
7
8
9
10
11
12
13
A
B
C
Summary of Contents for Siemens SIWAREX WP321
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will be
used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property
damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified
personnel are those who, based on their training and experience, are capable of identifying risks and avoiding
potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended or
approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software described.
Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this
publication is reviewed regularly and any necessary corrections are included in subsequent editions.
Siemens AG
Division Process Industries and Drives
Postfach 48 48
90026 NÜRNBERG
GERMANY
Document order number: A5E33715669A
Ⓟ 08/2019 Subject to change
Copyright © Siemens AG 2014 — 2019.
All rights reserved
Table of Contents for Siemens SIWAREX WP321:
-
SIWAREX WP321 Manual, 07/2014, A5E33715669A-02 45 Scale parameters and functions 8 8.1 Parameters and functions All parameters are set to default values in the factory. You can restore the configuration to factory settings using the «Load factory settings» command. The scales are ready for operation with the default parameter settings. You do not need to re-enter all parameters. The advantage of this solution is that you can decide the default values to be retain and th
-
Technical data 12.3 Approvals SIWAREX WP321 114 Manual, 07/2014, A5E33715669A-02 12.3 Approvals Note The current approvals for SIWAREX WP321 can be found on the module rating plate. Guidelines • 2004/108/EC «Electromagnetic Compatibility» In preparation In preparation 94/9/EC ATEX, type of protection II 3 G Ex nA IIC T4 Gc NOTICE Applications in hazardous areas For applicatio
-
Scale parameters and functions 8.3 DR 3 calibration parameters SIWAREX WP321 50 Manual, 07/2014, A5E33715669A-02 8.3.10 Maximum negative zeroing limit Zeroing defines the current weight of the scales as zero. You can limit the effect of the zeroing function. The limitation is based not on the current gross weight, but rather on the weight which the scales would display had there been no zeroing (time of scale calibration). 8.3.11 Maximum positive zeroing limit You can limit the effect of the zeroing
-
Scale parameters and functions 8.10 DR 13 RS485 parameters SIWAREX WP321 70 Manual, 07/2014, A5E33715669A-02 8.10.1 RS485 protocol This parameter defines the protocol for communication via the RS485 interface. The SIWATOOL program does not require any presettings. Value Protocol 0 No communication/protocol 2 SIEBERT display 8.10.2 RS485 baud rate This parameter defines the baud rate for the RS485 interface. Value Baud rate 0 9 600 bps 1 19 200 bps 2 38 400 bps 3 57 600 bps 4 115 000 bps 8.10.3
-
Scale parameters and functions 8.3 DR 3 calibration parameters SIWAREX WP321 46 Manual, 07/2014, A5E33715669A-02 8.3 DR 3 calibration parameters The calibration parameters need to be checked and if necessary modified for all scales. The scale is basically defined by calibration parameters and calibration operation. Procedure ● Check all parameters and modify them as required. ● Transfer the DR 3 data record from SIWATOOL to the scale. ● Calibrate the scale. ● Transfer the DR 3 d
-
Mounting 5.4 Configuration of the hardware in SIMATIC SIWAREX WP321 24 Manual, 07/2014, A5E33715669A-02 5.4 Configuration of the hardware in SIMATIC A station has a maximum width of 1 m, and you can use up to 64 modules depending on the type of PN head-end, or up to 15 modules with the Profibus version. Observe the system conditions when planning the configuration. Each SIWAREX electronic weighing system requires
-
Scale parameters and functions 8.9 DR 10 load cell parameters SIWAREX WP321 68 Manual, 07/2014, A5E33715669A-02 8.9.1 50/60 Hz toggling To improve the suppression of faults caused by the supply network, you can specify the network frequency for signal filtering. The measuring rate is 100 Hz for the 50 Hz setting, and 120 Hz for the 60 Hz setting. 8.9.2 Number of support points If no anchor po
-
Mounting 5.2 EMC-compliant setup SIWAREX WP321 20 Manual, 07/2014, A5E33715669A-02 5.2 EMC-compliant setup 5.2.1 Introduction The electronic weighing system described here was developed for use in industrial environments and complies with high EMC requirements. It ensures safe operation even in harsh environmental conditions. Nevertheless, you should still carry out EMC planning before installing your devices in order to determine any sources of interference and include them in your considerations. EMC EMC (electromagnetic com
-
Commissioning 7.3 5-minute quick start with the operator panel and the Ready-for-Use software SIWAREX WP321 32 Manual, 07/2014, A5E33715669A-02 7.3 5-minute quick start with the operator panel and the Ready-for-Use software 7.3.1 Start The 5-minute quick start is carried out in this example using a TP700 Comfort Panel connected to the SIMATIC CPU. The panel communicates with the SIWAREX module via the SIMATIC CPU. To carry o
-
Siemens AG Division Digital Factory Postfach 48 48 90026 NÜRNBERG GERMANY Order number: A5E33715669A Ⓟ 12/2014 Subject to change Copyright © Siemens AG 2014. All rights reserved Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol
-
Commissioning 7.5 Service with the SIWATOOL program SIWAREX WP321 Manual, 07/2014, A5E33715669A-02 43 7.5.2 Offline parameter assignment All scale parameters can be edited and saved without an electronic weighing system. This reduces the setup time. You can thus prepare the parameters for several scales in your office, and subsequently transfer them to the electronic weighing system during setup. Data from one scale currently in operation can be exported and used to set up another scale. 7.5.3 Online parameter assignment To swit
Questions, Opinions and Exploitation Impressions:
You can ask a question, express your opinion or share our experience of Siemens SIWAREX WP321 device using right now.
Detail Specifications: 987/987119-siwarex_wp321.pdf file (08 Apr 2023) |
Accompanying Data:
Siemens SIWAREX WP321 Kitchen Appliances PDF Manual (Updated: Saturday 8th of April 2023 07:34:14 AM)
Rating: 4.6 (rated by 82 users)
Compatible devices: HR745.25N, SIMATIC VS120, enlighted SU-5i-USB, AP 257/41, HX74W.30Y, HFPO-11, 2200 Series, GAMMA instabus 5WG1 211-2DB01.
Recommended Documentation:
Text Version of Manual
(Ocr-Read Summary of Contents, UPD: 08 April 2023)
-
107, Siemens SIWAREX WP321 SIWAREX WP321 Manual, 07/2014, A5E33715669A-02 107 Technical data 12 12.1 Technical specifications 24 V power supply Note A protective extra-low voltage (to EN 60204-1) is to be ensured by system power supply. Rated voltage 24 V DC Static low / high limits 19.2 V DC / 28.8 V DC Dynamic low / high limits 18.5 V DC / 30.2 V DC N…
-
13, SIWAREX WP321 Manual, 07/2014, A5E33715669A-02 13 Description 3 3.1 Product overview SIWAREX WP321 is a versatile and flexible weighing module that can be operated as a static weighing instrument. The electronic weighing system can be used in SIMATIC ET 200SP and uses all features of a modern automation system, such as integrated communication…
-
78, Scale parameters and functions 8.14 DR 31 advanced current process values SIWAREX WP321 78 Manual, 07/2014, A5E33715669A-02 8.14.3 Refresh counter for process values Measured values are calculated every 10 ms in the SIWAREX module. A counter is incremented by 1 each time. Once the counter reaches the value 65536, it starts again from zero. The counter can be used as …
-
2, Siemens AG Division Digital Factory Postfach 48 48 90026 NÜRNBERG GERMANY Order number: A5E33715669A Ⓟ 12/2014 Subject to change Copyright © Siemens AG 2014. All rights reserved Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to pr…
-
57, Scale parameters and functions 8.4 Calibration procedure SIWAREX WP321 Manual, 07/2014, A5E33715669A-02 57 8.4.2 Automatic calibration Scales can be rapidly commissioned with automatic calibration. The accuracy of the scale greatly depends on the entered parameters and the mechanical properties of the scale. However, you achieve the best level of accuracy f…
-
85, Siemens SIWAREX WP321 SIWAREX WP321 Manual, 07/2014, A5E33715669A-02 85 Messages 9 9.1 Message types The messages in the electronic weighing system described here are divided into three types. System status messages System status messages can be generated spontaneously at any time by an unexpected event. They include internal and external hardware problems w…
-
52, Scale parameters and functions 8.3 DR 3 calibration parameters SIWAREX WP321 52 Manual, 07/2014, A5E33715669A-02 8.3.14 Standstill waiting time Standstill waiting time is a maximum waiting time for standstill on execution of a command which depends on standstill (taring, zeroing). A technology message is generated if the command cannot be executed during…
-
116, Siemens SIWAREX WP321 Accessories SIWAREX WP321 116 Manual, 07/2014, A5E33715669A-02 Ordering data Description Order No. Digital remote display The digital remote displays can be connected directly to the SIWAREX WP321 through the RS485 interface. Suitable remote display: S102 Siebert Industrieelektronik GmbH Postfach 1180 D-66565 Eppelborn, Germany Tel.: 06806/980-0 Fax: 06806/980-9…
-
24, Mounting 5.4 Configuration of the hardware in SIMATIC SIWAREX WP321 24 Manual, 07/2014, A5E33715669A-02 5.4 Configuration of the hardware in SIMATIC A station has a maximum width of 1 m, and you can use up to 64 modules depending on the type of PN head-end, or up to 15 modules with the Profibus version. Observe the system conditions when planning the configuration. …
-
28, Connection 6.3 Shield connection SIWAREX WP321 28 Manual, 07/2014, A5E33715669A-02 6.3 Shield connection Make sure you observe the correct design of the shield support for the shielded cables. It is the only way to ensure immunity of the system. A cable is shielded to attenuate the effects of magnetic, electrical and electromagnetic interference …
-
84, Scale parameters and functions 8.16 DR 34 ASCII main display value SIWAREX WP321 84 Manual, 07/2014, A5E33715669A-02
…
Recommended Instructions:
VIRTUOSO MULTI-MODE SIMULATION, VT-58, iPAQ, Laser IRT, MXP144, XI41DU
-
Installation & CalibrationED2-AT Series SkidWeigh System Lift Truck On-board Check Weighing With Accumulative Load Weight Total ED2-AT Series SkidWeigh V.1.1 Integrated Visual Data Technology Inc. 3439 Whilabout Terrace, Oakville, Ontario, Canada L6L 0A7 …
SkidWeigh ED2-AT Series 11
-
14-01-2020 9060148 & 9060149 DK/N: Frugtpresser, hydraulisk S: Fruktpress — Hydropress D: Hydraulische Obst-/Saftpresse GB: Hydraulic Fruit Press 20/40 L www.p-lindberg.dk www.p-lindberg.no www.p-lindberg.se www.p-lindberg.de Original Manual DK S D GB …
9060148 23
-
ORIGINAL INSTRUCTIONSAHE00053EN 1904 9460163197EN-1Alfa Laval Alfa-V VDDInstruction manual• Product description• Product labels• Transport & lifting• Installation• Maintenance• Spare parts …
Alfa-V VDD Series 20
-
RECHARGING RAZORPLUSConnect the included recharging cable to your RAZORPLUS and to a power source – wall, computer, or car. Your RAZORPLUS is built with technology that maximizes the amount of available power going into your charger so you can rest assured that it’s recharging at the fastest rate allowed.As your RAZORPLUS recharges, the LED lights will illum …
RAZORPLUS 2
Additional Information:
Popular Right Now:
Operating Impressions, Questions and Answers:
Download Manual of Siemens SIWAREX WP321 Kitchen Appliances for Free or View it Online on All-Guides.com.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
Electronic weighing system
SIWAREX WP321
Scale parameters and
functions
Communication in SIMATIC
S7—300/1200/1500