Тепловизор fluke ti20 инструкция по эксплуатации

Fluke Ti20 User Manual

  • Contents

  • Table of Contents

  • Bookmarks

Quick Links

®

Ti20

Thermal Imager

Users Manual

January 2006

© 2006 Fluke Corporation, All rights reserved.

All product names are trademarks of their respective companies.

loading

Related Manuals for Fluke Ti20

Summary of Contents for Fluke Ti20

  • Page 1
    ® Ti20 Thermal Imager Users Manual January 2006 © 2006 Fluke Corporation, All rights reserved. All product names are trademarks of their respective companies.
  • Page 2
    Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price.
  • Page 3: Table Of Contents

    Chapter Getting Started … 1-1 Introduction… 1-1 Contacting Fluke… 1-1 Safety Information … 1-2 Laser Warning Labels … 1-3 Unpacking the Imager… 1-4 Features and Controls … 1-6 Operating the Controls… 1-7 Focusing the Imager … 1-7 Understanding the Trigger… 1-8 Using the AC Power Adapter …

  • Page 4
    Ti20 Users Manual Environmental Conditions … 2-11 Ambient Temperature Derating and Thermal Shock … 2-11 Emissivity … 2-12 Reflected Temperature Compensation… 2-13 Advanced Imager Operation… 3-1 Data Management and Storage … 3-1 Viewing Stored Images … 3-1 Deleting Images… 3-2 Selecting a Palette …
  • Page 5
    Table 1-1. Symbols… 1-2 1-1. Standard Accessories … 1-5 1-3. Features and Controls… 1-7 2-1. Contents of the Home Display … 2-3 C-1. Emissivity Values for Metals … C-2 C-2. Emissivity Values for Non-Metals… C-4 List of Tables Title Page…
  • Page 6
    Ti20 Users Manual…
  • Page 7
    Figure 1-1. Laser Warning Labels … 1-3 1-2. Standard Accessories … 1-4 1-3. Ti20 Thermal Imager Features and Controls … 1-6 1-4. Focusing the Imager … 1-8 1-5. Using the AC Power Adapter… 1-9 1-6. Using the Battery Charger… 1-10 1-7.
  • Page 8
    Ti20 Users Manual…
  • Page 9: Getting Started

    Introduction The Fluke Ti20 Imager (hereafter, “the Imager”) is a state-of-the-art, lightweight, pistol- grip style thermal imaging unit. Using the Imager, you can obtain instant and accurate thermal images and radiometric readings from distant targets. The Imager is ergonomically designed for right-hand or left-hand use, and captures thermal images and data with a simple trigger press.

  • Page 10: Safety Information

    Ti20 Users Manual Safety Information Use the Imager only as specified in this manual. See Table 1 for a list of symbols used on the Imager and in this manual. A W Warning identifies hazardous conditions and actions that could cause bodily harm or death.

  • Page 11: Laser Warning Labels

    Laser Warning Labels Euro/US < 1mW/630-670nm EN 60825/01 CAUTION Ti 20 THERMAL IMAGER Japanese CAUTION Ti 20 THERMAL IMAGER Figure 1-1. Laser Warning Labels Getting Started Laser Warning Labels Chinese CAUTION Ti20 THERMAL IMAGER dag133f.eps…

  • Page 12: Unpacking The Imager

    Ti20 Users Manual Unpacking the Imager Begin by opening the shipping box. Be sure to save the box and shipping materials in case you need to ship the Imager. Inside the shipping box, you will find a hard carrying case containing the standard accessories shown in Figure 1-2 and described in Table 1-2.

  • Page 13: Standard Accessories

    PN 2455818 Soft Case with Shoulder Strap PN 2446641 Rechargeable Battery Pack (2) PN 2492146 CD-ROM with InsideIR software and Users Manual and PN 2492154 Ti20 Training Material PN 2492228 Quick Reference Guide PN 2444076 International AC Adapter PN 2518704 Hard Case…

  • Page 14: Features And Controls

    Ti20 Users Manual Features and Controls Imager features and controls are shown in Figure 1-3 and described in Table 1-3. Figure 1-3. Ti20 Thermal Imager Features and Controls dag01f.eps…

  • Page 15: Operating The Controls

    Number Focus control Optical channel Laser aperture Wrist strap and attachment clip Trigger. The trigger is used to freeze a thermal image. Press the trigger one time to freeze the image for evaluation. You can save the image or press and release the trigger again to delete the image.

  • Page 16: Understanding The Trigger

    Ti20 Users Manual Optical Channel Understanding the Trigger The trigger is located in the standard trigger position for a pistol-grip device. The primary function of the trigger is to freeze a thermal image for possible storage to memory by the user.

  • Page 17: Using The Ac Power Adapter

    Getting Started Using the AC Power Adapter Using the AC Power Adapter dag007f.eps Figure 1-5. Using the AC Power Adapter…

  • Page 18: Charging And Replacing The Batteries

    Users Manual Charging and Replacing the Batteries With the Ti20, you have the option of using six AA batteries or a rechargeable NiMH pack. The use of both options is described in the following pages. Battery charger use is shown is Figure 1-6 and battery placement in Figure 1-7 .

  • Page 19: Installing Or Replacing The Batteries

    Installing or Replacing the Batteries Replace the batteries with six AA batteries (NEDA 15A or IEC LR6). Install or Replace the AA battery cartridge as described below and shown in Figure 1-7. 1. Unlock the battery compartment by using a standard screwdriver to turn the battery door screw one-quarter turn counterclockwise.

  • Page 20: Attaching The Wrist Strap

    Ti20 Users Manual Attaching the Wrist Strap A wrist strap is included with your Imager. You can attach the wrist strap by clipping the strap to the attachment clip on the Imager housing. 1-12 Figure 1-8. Attaching the Wrist Strap…

  • Page 21: Inputs And Connections

    Inputs and Connections Connecting the USB Cable The included USB cable can be used to either download or upload data from a PC to the Imager. To connect the USB cable, insert the smaller USB connector into the Imager port and the larger connector into the PC USB port as shown in Figure 1-9.

  • Page 22: Mounting The Imager On A Tripod

    Ti20 Users Manual Mounting the Imager on a Tripod A tripod mount is provided on the bottom side of the Imager. Rotate or screw the Imager onto a tripod using the tripod mount as shown in Figure 1-10. Ti 20…

  • Page 23: Cleaning The Lens

    Cleaning the Lens Although the lens is coated with a durable, erosion resistant coating (according to MIL standards), cleaning dust, sand, and other particles might scratch the coating and impair the performance of the lens. To avoid damage, do not use tools or sharp objects when cleaning the lens.

  • Page 24
    Ti20 Users Manual 1-16…
  • Page 25: Basic Operation

    After approximately 5 seconds, the Imager loads the Home display. The Imager splash screen is shown in Figure 2-1 and displays the following information: Date and Time Fluke and MicroIR logos Model Number Serial Number Firmware Version…

  • Page 26: Understanding The Home Display

    Ti20 Users Manual Understanding the Home Display The Imager returns to the Home display when you complete a menu operation, escape or cancel an operation using the G soft key, or the by pressing the trigger. Figure 2-2 illustrates the Home display zones.

  • Page 27: Contents Of The Home Display

    The contents of the Home display is described in Table 2-1. Table 2-1. Contents of the Home Display Displayed Number Zone Information Manual Calibrating Capture Review Delete or Delete Date and Time Header Thermal Image Description Auto Imager is in automatic imaging mode Imager is in manual imaging mode Indicates the Imager is calibrating and is temporarily incapable of measuring…

  • Page 28: Aiming And Activating The Laser

    Ti20 Users Manual Number Zone Information Aiming and Activating the Laser The laser is a sighting aid and is not required to take measurements. The laser is not coaxial with the infrared channel, and the laser dot is offset from the center of the thermal image (the crosshatch at the center of the display).

  • Page 29: Capturing Images

    The Japanese model of the Ti20 requires you to press and hold F to turn on the laser and keep it on. When you release F, the laser turns off. Capturing Images Recording images is a simple process but before starting you should note the current image location number.

  • Page 30: Adjusting The Backlight

    Ti20 Users Manual If no image is stored at the current memory location, the right side of the display is black. 3. Press G ( image location. Adjusting the Backlight Backlight ON is recommended for indoor use set the backlight OFF for outdoor applications and to save battery life.

  • Page 31: Setting The Temperature Scale

    Setting the Temperature Scale The Imager displays temperatures using either the Celsius or Fahrenheit temperature scales. The default temperature scale is Celsius. 1. Press G ( MENU scale function. 2. Press H (TEMPSCALE Celsius. Setting the Level In Manual mode, you can define Level and Span values manually. Manual mode allows you to bring both MIN and MAX values to the desired cut-off levels and to adjust the temperature interval to a minimum to maximizing color resolution.

  • Page 32
    Ti20 Users Manual 3. Press F 4. Press F (4) to move the window to the left (lower) or H (5) to move the window to the right (higher). 5. Press G ) to access the set Level function. (LEVEL ) two times to return to the Home display.
  • Page 33: Adjusting The Span

    Using Distance to Spot Size Ratio (D:S) The Ti20 imager views a portion of the scene that is 15 º high by 20 º wide (the Field-Of- View (FOV), of the Imager) as shown in Figure 2-3. This scene is displayed on the LCD on the back of the Imager.

  • Page 34
    Ti20 Users Manual Measurement Spot (S = Diameter of the Spot) dag135f.eps Figure 2-3. Relationship Between FOV and Measurement Spot and Reticle 2-10…
  • Page 35: Environmental Conditions

    Environmental Conditions Watch for environmental conditions in the working area. steam, dust, smoke, etc., can prevent accurate measurement by obstructing the path between the target and the Imager optics. Noise, electromagnetic fields, or vibration are other conditions that can interfere with temperature measurements, and should be considered before starting temperature measurements.

  • Page 36: Emissivity

    Ti20 Users Manual Emissivity Emissivity is the measure of an object’s ability to emit infrared energy. The hotter an object, the more infrared energy it will emit. Emissivity can have a value from 0 (shiny mirror, perfect reflector) to 1.0 (blackbody, perfect emitter). Most organic, painted, or oxidized surfaces have emissivity values close to 0.95.

  • Page 37: Reflected Temperature Compensation

    Reflected Temperature Compensation Targets that have low emissivities will reflect energy from nearby objects. This additional reflected energy is added to target’s own emitted energy and may result in inaccurate readings. In some situations objects near the target (machines, furnaces, or other heat sources) have a temperature much higher than that of the target.

  • Page 38
    Ti20 Users Manual 2-14…
  • Page 39: Advanced Imager Operation

    Advanced Imager Operation Data Management and Storage Viewing Stored Images 1. From the Home display, press G ( 2. Press F ( REVIEW 3. Press F (2) to view the next image or F3 (1) to view the previous image. 4.

  • Page 40: Deleting Images

    Ti20 Users Manual Deleting Images Deleting an image deletes the image in the active memory location but retains location description, any notes, emissivity, and RTC setting. The delete all selection completely erases the Imager flash memory including all images, notes, emissivity values, and RTC settings.

  • Page 41: Selecting A Palette

    5. The Delete ALL Images Press F ( ) to delete all the stored images or G ( Home display. 6. After deleting all images you will return to the Home display. Selecting a Palette Palettes are used to change the color of live thermal images or the palette of the temperature color bar.

  • Page 42: Adjusting Emissivity

    Ti20 Users Manual 3. Press F (4) to move the selection to the left or H (5) to move the selection to the right. 4. Press G ( Adjusting Emissivity The amount of infrared energy radiated by an object depends on emissivity and temperature.

  • Page 43
    2. Press F ( )to access the Adjust Emissivity 3. Press F (2) to increase the emissivity value or H (1) to decrease the emissivity value. 4. Press G ( ) to return to the Home display. DONE Advanced Imager Operation Adjusting Emissivity display.
  • Page 44: Adjusting Reflected Temperature Compensation Values

    Ti20 Users Manual Adjusting Reflected Temperature Compensation Values As the RTC value changes, the live thermal image will also change as the displayed temperature changes. The default RTC setting is 100 C (212 F)and the adjustment range is from -50 C to 600 C (-58 F to 1112 F). RTC is OFF in the factory default state.

  • Page 45: Setting Alarm Limits

    4. In the Adjust RTC to decrease the RTC value. 5. Press G ( DONE Setting Alarm Limits When you adjust alarm limits, the lower alarm limit appears in blue text in the information zone and upper alarm limit appears in red text in the information zone. The low alarm indicator ( ) and high alarm indicator ( ) also move on the temperature scale.

  • Page 46
    Ti20 Users Manual 2. Press F ( 3. Press F ( alarm limit. 4. Press F (2) to increase the alarm limit or H (1) to decrease the alarm limit. 5. Press G( ) to access the Adjust Alarms display.
  • Page 47: Adjusting Sleep Mode

    Adjusting Sleep Mode Sleep mode is used to conserve battery life if the Imager is turned on but not being used. If you turn Sleep mode mode is enabled, the Imager will automatically power down after the specified time period.The default Sleep mode time period is 15 minutes. 1.

  • Page 48
    Ti20 Users Manual 3-10…
  • Page 49: Appendices

    Appendices Appendix Contents Page Glossary …A-1 Basics of Infrared Measurement…B-1 Typical Emissivity Values …C-1 Specifications …D-1…

  • Page 51: A Glossary

    Appendix A Glossary Absolute Zero The temperature (0 degrees Kelvin) of an object defined by the theoretical condition where the object has zero energy. Accuracy Maximum deviation, expressed in temperature units, or as a percentage of the temperature reading, or as a percentage of the full scale temperature value, or as a percentage of the target temperature, indicating the difference between a temperature reading given by an instrument under ideal operating conditions, and the temperature of a calibration source (per the ASTM standard test method E 1256-88).

  • Page 52
    Ti20 Users Manual Blackbody A perfect emitter; an object that absorbs all the radiant energy incident on it at all wavelengths and reflects and transmits none. A surface with emissivity of unity (1.00). Calibration A methodical measurement procedure to determine all the parameters significantly affecting an instrument’s performance.
  • Page 53
    Appendices Glossary Field of View (FOV) The region, at the target, measured by the IR thermometer. Typically presented by giving the spot diameter as a function of distance from the instrument. Also presented as the angular size of the spot at the focus point. See Optical Resolution.
  • Page 54
    Ti20 Users Manual Level Level is the median point of a given temperature scale. For example, if the unit is currently in Automatic mode, and there is a given thermal scene with MIN and MAX temperature limits, the moment you switch the unit to Manual mode, the Level value is set by the unit according to the following formula: Micron (or µm)
  • Page 55
    95 percent of full scale temperature indication (per the ASTM standard test method E 1256-88). The specification for Fluke instruments also includes the average time required for software computations. Scatter (Size of Source Effect) An undesirable increase in temperature reading caused by IR energy outside the spot reaching the detector.
  • Page 56
    Ti20 Users Manual Stare A saturation effect caused by aiming a sensor at a hot target for an extended period of time and then quickly aiming at a target at a lower temperature. The increase in time (beyond the normal system response) for the sensor to return to within 5 % of the lower temperature is defined as the stare time.
  • Page 57: Basics Of Infrared Measurement

    Appendix B Basics of Infrared Measurement Q. Why use non-contact infrared thermometers? Non-contact infrared (IR) thermometers use infrared technology to quickly and conveniently measure the surface temperature of objects. They provide fast temperature readings without physically touching the object. The temperature is shown on the LCD display.

  • Page 58
    Ti20 Users Manual Gamma X-Rays Ultraviolet Rays 0.1 A 1 UA 100 A Q. How to assure accurate temperature measurement? A. A solid understanding of infrared technology and its principles lies behind accurate temperature measurement. When the temperature is measured by a non-contact device the IR energy emitted from the measured object passes through the optical system of the thermometer or thermal imager and is converted to an electrical signal at the detector.
  • Page 59
    Food Service & Safety: Scan holding, serving, and storage temperatures. Process Control & Monitoring: check process temperature of steel, glass, plastics, cement, paper, food & beverage For additional information on applications for non-contact IR thermometers visit our website at www.fluke.com/thermography. Appendices Basics of Infrared Measurement…
  • Page 60
    Ti20 Users Manual…
  • Page 61: Typical Emissivity Values

    Typical Emissivity Values The following tables provide references for estimating emissivity and can be used when the user does not have the means or the time to determine the emissivity value experimentally. Emissivity values shown in the tables are only approximate. Any or all of the following parameters can affect the emissivity of an object: Temperature Angle of measurement…

  • Page 62: C-1. Emissivity Values For Metals

    Ti20 Users Manual Material Aluminum Unoxidized Oxidized Alloy A3003, Oxidized Roughened Polished Brass Polished Burnished Oxidized Chromium Copper Polished Roughened Oxidized Electrical Terminal Blocks Gold Haynes Alloy Inconel Oxidized Sandblasted Electropolished Iron Oxidized Unoxidized Rusted Molten Table C-1. Emissivity Values for Metals 1.0 µm…

  • Page 63
    Table C-1. Emissivity Values for Metals (cont) Material Iron, Cast Oxidized Unoxidized Molten Iron, Wrought Dull Lead Polished Rough Oxidized Magnesium Mercury Molybdenum Oxidized Unoxidized Monel (Ni-Cu) Nickel Oxidized Electrolytic Platinum Black Silver Steel Cold-Rolled Ground Sheet Polished Sheet Molten Oxidized Stainless Emissivity…
  • Page 64: C-2. Emissivity Values For Non-Metals

    Ti20 Users Manual Material Tin (Unoxidized) Titanium Polished Oxidized Tungsten Polished Zinc Oxidized Polished Material Asbestos Asphalt Basalt Carbon Unoxidized Graphite Carborundum Ceramic Clay Concrete Cloth Glass Plate “Gob” Gravel Gypsum Table C-1. Emissivity Values for Metals (cont) 1.0 µm 0.25…

  • Page 65
    Table C-2. Emissivity Values for Non-Metals (cont) Material Limestone Paint (non-Al.) Paper (any color) Plastic (opaque, over 20 mils) Rubber Sand Snow Soil Water Wood, Natural To optimize surface temperature measurement accuracy consider the following: Determine the object emissivity for the spectral range of the instrument to be used for the measurement.
  • Page 66
    Ti20 Users Manual…
  • Page 67: Specifications

    Appendix D Specifications Thermal Temperature Range… -10 to 350 C (14 to 662 F) Detector Type … 80 x 60 thermal element focal plane array (FPA) Accuracy … 2 C or 2 % (whichever is greater) Repeatability … 1 % or 1 C ( 2 F) whichever is greater NETD (Thermal Sensitivity) …

  • Page 68
    Ti20 Users Manual Other Weight… 1.2 kg (2.65 lb) Shock … Half-sine, 11 ms, 30 g peak per MIL-PRF-28800F Vibration… Random EMC … EN 61326-1 Sinusoidal MIL-PRF-28800, paragraph 4.5.5.3.1, Class 2…

®

Ti20

Thermal Imager

Users Manual

January 2006

© 2006 Fluke Corporation, All rights reserved.
All product names are trademarks of their respective companies.

LIMITED WARRANTY AND LIMITATION OF LIABILITY

Each Fluke product is warranted to be free from defects in material and workmanship under normal use and
service. The warranty period is one year and begins on the date of shipment. Parts, product repairs, and
services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of
a Fluke authorized reseller, and does not apply to fuses, disposable batteries, or to any product which, in
Fluke’s opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnor mal
conditions of operation or handling. Fluke warrants that software will operate substantially in accordance
with its functional specifications for 90 days and that it has been properly recorded on non-defective media.
Fluke does not warrant that software will be error free or operate without interruption.

Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers
only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is
available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the
applicable international price. Fluke reserves the right to invoice Buyer for importation costs of
repair/replacement parts when product purchased in one country is submitted for repair in another country.

Fluke’s warranty obligation is limited, at Fluke’s option, to refund of the purchase price, free of charge repair,
or replacement of a defective product which is returned to a Fluke authorized service center within the
warranty period.

To obtain warranty service, contact your nearest Fluke authorized service center to obtain return
authorization information, then send the product to that service center, with a description of the difficulty,
postage and insurance prepaid (FOB Destination). Fluke assumes no risk for damage in transit. Following
warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke
determines that failure was caused by neglect, misuse, contamination, alteration, accident, or abnormal
condition of operation or handling, including overvoltage failures caused by use outside the product’s
specified rating, or normal wear and tear of mechanical components, Fluke will provide an estimate of repair
costs and obtain authorization before commencing the work. Following repair, the product will be returned to
the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges
(FOB Shipping Point).

THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE
FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR LOSSES,
INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY.

Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or
limitation of incidental or consequential damages, the limitations and exclu sions of this warranty may not
apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court or other
decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any other
provision.

Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
U.S.A.

Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands

11/99

Table of Contents

Chapter Title Page

1 Getting Started ………………………………………………………………………… 1-1

Introduction………………………………………………………………………………………….. 1-1

Contacting Fluke…………………………………………………………………………………… 1-1

Safety Information ………………………………………………………………………………… 1-2

Laser Warning Labels……………………………………………………………………………. 1-3

Unpacking the Imager……………………………………………………………………………. 1-4

Features and Controls ……………………………………………………………………………. 1-6

Operating the Controls…………………………………………………………………………… 1-7

Focusing the Imager ………………………………………………………………………….. 1-7

Understanding the Trigger………………………………………………………………….. 1-8

Using the AC Power Adapter …………………………………………………………………. 1-9

Charging and Replacing the Batteries………………………………………………………. 1-10

Using the Battery Charger ………………………………………………………………….. 1-10

Installing or Replacing the Batteries ……………………………………………………. 1-11

Attaching the Wrist Strap ………………………………………………………………………. 1-12

Inputs and Connections………………………………………………………………………….. 1-13

Connecting the USB Cable…………………………………………………………………. 1-13

Mounting the Imager on a Tripod………………………………………………………… 1-14

Cleaning………………………………………………………………………………………………. 1-14

Cleaning the Case ……………………………………………………………………………… 1-14

Cleaning the Lens ……………………………………………………………………………… 1-15

2 Basic Operation……………………………………………………………………….. 2-1

Turning the Imager On and Off ………………………………………………………………. 2-1

Understanding the Home Display……………………………………………………………. 2-2

Aiming and Activating the Laser…………………………………………………………….. 2-4

Capturing Images………………………………………………………………………………….. 2-5

Comparing Frozen Images to Stored Images…………………………………………….. 2-5

Adjusting the Backlight …………………………………………………………………………. 2-6

Setting the Temperature Scale ………………………………………………………………… 2-7

Setting the Level …………………………………………………………………………………… 2-7

Adjusting the Span………………………………………………………………………………… 2-9

Manually Activating the Calibration Flag ………………………………………………… 2-9

Using Distance to Spot Size Ratio (D:S) ………………………………………………….. 2-9

i

Ti20

Users Manual

Environmental Conditions ……………………………………………………………………… 2-11

Ambient Temperature Derating and Thermal Shock………………………………….. 2-11

Emissivity ……………………………………………………………………………………………. 2-12

Reflected Temperature Compensation……………………………………………………… 2-13

3 Advanced Imager Operation……………………………………………………… 3-1

Data Management and Storage ……………………………………………………………….. 3-1

Viewing Stored Images ……………………………………………………………………… 3-1

Deleting Images………………………………………………………………………………… 3-2

Selecting a Palette…………………………………………………………………………………. 3-3

Adjusting Emissivity……………………………………………………………………………… 3-4

Adjusting Reflected Temperature Compensation Values……………………………. 3-6

Setting Alarm Limits …………………………………………………………………………….. 3-7

Adjusting Sleep Mode …………………………………………………………………………… 3-9

Appendices

A Glossary…………………………………………………………………………………………. A-1

B Basics of Infrared Measurement………………………………………………………… B-1

C Typical Emissivity Values………………………………………………………………… C-1

D Specifications …………………………………………………………………………………. D-1

ii

List of Tables

Table Title Page

1-1. Symbols…………………………………………………………………………………………………… 1-2

1-1. Standard Accessories ………………………………………………………………………………… 1-5

1-3. Features and Controls………………………………………………………………………………… 1-7

2-1. Contents of the Home Display ……………………………………………………………………. 2-3

C-1. Emissivity Values for Metals ……………………………………………………………………… C-2

C-2. Emissivity Values for Non-Metals………………………………………………………………. C-4

iii

Ti20

Users Manual

iv

List of Figures

Figure Title Page

1-1. Laser Warning Labels ……………………………………………………………………………….. 1-3

1-2. Standard Accessories ………………………………………………………………………………… 1-4

1-3. Ti20 Thermal Imager Features and Controls ………………………………………………… 1-6

1-4. Focusing the Imager………………………………………………………………………………….. 1-8

1-5. Using the AC Power Adapter……………………………………………………………………… 1-9

1-6. Using the Battery Charger………………………………………………………………………….. 1-10

1-7. Replacing the Battery Pack ………………………………………………………………………… 1-11

1-8. Attaching the Wrist Strap…………………………………………………………………………… 1-12

1-9. Connecting Using the USB Cable……………………………………………………………….. 1-13

1-10. Mounting the Imager on a Tripod ……………………………………………………………….. 1-14

2-1. Imager Splash Screen………………………………………………………………………………… 2-1

2-2. Imager home Display Zones ………………………………………………………………………. 2-2

2-3. Relationship Between FOV and Measurement Spot and Reticle……………………… 2-10

2-4. Correct Field of View………………………………………………………………………………… 2-11

2-5. Reflected Temperature Compensation …………………………………………………………. 2-14

B-1. Infrared Measurement Region…………………………………………………………………….. B-2

v

Ti20

Users Manual

vi

Introduction

The Fluke Ti20 Imager (hereafter, “the Imager”) is a state-of-the-art, lightweight, pistol­grip style thermal imaging unit. Using the Imager, you can obtain instant and accurate
thermal images and radiometric readings from distant targets. The Imager is
ergonomically designed for right-hand or left-hand use, and captures thermal images and
data with a simple trigger press. The Imager can store up to 50 images that can be
downloaded to your personal computer for storage, analysis, and report preparation.

The InsideIR companion software application, lets you display, examine, and analyze
your images and data to determine qualitative and quantitative trends associated with the
target equipment. You can also use InsideIR to define maintenance databases based on
your equipment conditions, monitoring, and asset management needs.

The Imager provides high performance thermal imaging and is designed for industrial
use. The Ti20:

Uses new detection technology to provide a clear thermal image with accurate

temperature measurements up to 350 °C (662 °F).

Chapter 1

Getting Started

Is protected against dust and moisture (IP54 rated) for use in harsh industrial

environments.

Provides a minimum of 3 hours of continuous battery life.

Contacting Fluke

To contact Fluke, call:

1-888-993-5853 in USA
1-800-363-5853 in Canada
+31-402-675-200 in Europe
+81-3-3434-0181 in Japan
+65-738-5655 in Singapore
+1-425-446-5500 from anywhere in the world

Or, visit Fluke’s Web site at www.fluke.com

To register your product, visit register.fluke.com

1-1

Ti20

Users Manual

Safety Information

Use the Imager only as specified in this manual. See Table 1 for a list of symbols used on
the Imager and in this manual.

A W Warning identifies hazardous conditions and actions that could cause bodily harm

or death.

A W Caution identifies conditions and actions that could damage the Imager or cause

permanent loss of data.

W Warning

* To avoid eye damage, do not point laser directly at

eye or indirectly off reflective surfaces.

Use of controls or adjustments or performance or

procedures other than those specified herein may result
in hazardous laser radiation exposure.

To avoid a burn hazard, remember that highly reflective

objects will result in lower than actual temperature
measurements. See Emissivity information later in this
manual for more information.

Do not use in a manner not specified in this manual or

the protection provided by the equipment may be
impaired.

Table 1-1. Symbols

* Warning. Laser. P

Do not mix with solid waste stream.

~

Dispose using a qualified recycler or
hazardous material handler.

W Important information: see manual

Conforms to requirements of European
Union and European Free Trade
Association

1-2

Getting Started

Laser Warning Labels 1

Laser Warning Labels

Euro/US Japanese Chinese

<

1mW/630-670nm

EN 60825/01

CAUTION

CAUTION

CAUTION

Ti20

THERMAL IMAGER

Ti20

THERMAL IMAGER

Figure 1-1. Laser Warning Labels

Ti20

THERMAL IMAGER

dag133f.eps

1-3

Ti20

Users Manual

Unpacking the Imager

Begin by opening the shipping box. Be sure to save the box and shipping materials in
case you need to ship the Imager. Inside the shipping box, you will find a hard carrying
case containing the standard accessories shown in Figure 1-2 and described in Table 1-2.

2

1

3

6

10

9

4

5

7

11

8

1-4

Figure 1-2. Standard Accessories

dag134f.eps

Getting Started

Table 1-2. Standard Accessories

A PN 1671807 USB Cable B PN 2444076 International AC Adapter

Unpacking the Imager 1

PN 2507729 External Charger for

C

Rechargeable Battery Pack

D PN 2518704 Hard Case

E PN 2455818 Soft Case with Shoulder Strap F PN 2443380 Wrist Strap
G PN 2446641 Rechargeable Battery Pack (2) H PN 2455807 AA Battery Tray

PN 2492146 CD-ROM with InsideIR
software and Users Manual and

I

PN 2492154 Ti20 Training Material

J PN 2492168 Getting Started Guide

K PN 2492228 Quick Reference Guide

1-5

Ti20

Users Manual

Features and Controls

Imager features and controls are shown in Figure 1-3 and described in Table 1-3.

1

Ti20

THERMAL IMAGER

2

3

CAUTION

AVOID EXPOSU

RE
LASER RADIATION
IS EMITTED

FR

OM

THIS APER

TUR

E

DO NO

T ST

ARE

INTO BEAM

OUTPUT <

1mW

WAVELENGTH:

630 — 670

nm

CLASS II

LASER

PRODUCT

COMPLIES

WITH

CFR 1040.

10

Ti20

T

HE

RM

A

L I

MAGE

R

7

5

6

8

9

ER

Ti20

AG

MAL IM
ER

H

T

10

4

11

1-6

dag01f.eps

Figure 1-3. Ti20 Thermal Imager Features and Controls

Getting Started

Table 1-3. Features and Controls

Number Description

A Focus control
B Optical channel
C Laser aperture
D Wrist strap and attachment clip
E Trigger. The trigger is used to freeze a thermal image. Press the trigger one time to freeze

the image for evaluation. You can save the image or press and release the trigger again to
delete the image.

F USB port
G AC adapter terminal
H Display
I The three soft keys (F, G, and H) are used to navigate the menu structure of the

Imager, access all functions, and select values for the various adjustable parameters. The

Operating the Controls 1

G soft key is also used to turn the Imager On and Off. Press and hold G for two

seconds to turn off the Imager.

J Battery compartment
K Threaded tripod mount

Operating the Controls

The following sections describe the purpose and function of the two Imager controls,
focus and trigger.

Focusing the Imager

Proper focus is critically important in radiometric imaging applications. The correct focus
ensures that the infrared energy is being properly directed onto the pixels of the detector.
Without the correct focus, the thermal image appears blurry and the radiometric data will
be inaccurate. Correct focus is necessary to accurately capture a thermal image.

Focus the Imager by turning the focus control in a clockwise or counterclockwise
direction (similar to the operation of a single lens reflex 35 mm photographic camera).
The Imager is designed to focus at a minimum distance of 61 cm (24 in) or less (rotated
fully clockwise as viewed from the rear of the instrument) and to a maximum of infinity
(rotated fully counterclockwise).

As you turn the focus control, you will see a changing, live, thermal image on the display.
When your target comes into focus, it will appear sharper. When the target moves out of
focus, it becomes blurry. One way to verify proper focus is to find what focus adjustment
produces the highest temperature indication on the display (keeping emissivity and
Reflected Temperature Compensation (RTC) values constant, preferably with emissivity
set at 1.0 and RTC disabled). See Figure 1-4 for an illustration of focusing the Imager.

1-7

Ti20

Users Manual

Optical Channel

Understanding the Trigger

The trigger is located in the standard trigger position for a pistol-grip device. The primary
function of the trigger is to freeze a thermal image for possible storage to memory by the
user. The trigger freezes an image in the following modes:

Ti20

THERMAL IMAGER

Figure 1-4. Focusing the Imager

Focus Ring

dag02f.eps

In automatic temperature level and span adjustment mode

In manual temperature level and span adjustment mode

When scrolling through the menu levels (without entering a menu selection)

1-8

Getting Started

Using the AC Power Adapter 1

Using the AC Power Adapter

Ti20

THERMAL IMAGER

Ti20

R

E

G

L IMA

A

M

R

E

TH

dag007f.eps

Figure 1-5. Using the AC Power Adapter

1-9

Ti20

Users Manual

Charging and Replacing the Batteries

With the Ti20, you have the option of using six AA batteries or a rechargeable NiMH
pack. The use of both options is described in the following pages. Battery charger use is
shown is Figure 1-6 and battery placement in Figure 1-7 .

Using the Battery Charger

.

1-10

Figure 1-6. Using the Battery Charger

dag008f.eps

Getting Started

Charging and Replacing the Batteries 1

Installing or Replacing the Batteries

Replace the batteries with six AA batteries (NEDA 15A or IEC LR6). Install or Replace
the AA battery cartridge as described below and shown in Figure 1-7.

1. Unlock the battery compartment by using a standard screwdriver to turn the

battery door screw one-quarter turn counterclockwise.

2. Slide the battery compartment door off the grip.

3. Uncouple the battery connector and remove the rechargeable battery (or battery

pack).

4. Change the rechargeable battery (or battery pack with fresh batteries).

5. Replace and reconnect the rechargeable battery (or battery pack.

6. Replace the battery door. Secure the door by turning the screw one-quarter turn

clockwise.

Ti20

1

R

E

AG
IM
L

A
M

R

Ti20

E
TH

2

3

THERMAL IMA GER

OR

dag03f.eps

Figure 1-7. Replacing the Battery Pack

1-11

Ti20

Users Manual

Attaching the Wrist Strap

A wrist strap is included with your Imager. You can attach the wrist strap by clipping the
strap to the attachment clip on the Imager housing.

IMAGER

20

AL

Ti

RM

HE

T

R

E

MAG

I

20

L

Ti

RMA

HE

T

1-12

Figure 1-8. Attaching the Wrist Strap

dag131f.eps

Getting Started

Inputs and Connections 1

Inputs and Connections

Connecting the USB Cable

The included USB cable can be used to either download or upload data from a PC to the
Imager. To connect the USB cable, insert the smaller USB connector into the Imager port
and the larger connector into the PC USB port as shown in Figure 1-9. Communications
begin automatically, and a USB symbol (I) appears in the header area of the Imager
display when communications are established.

Ti20

Ti20

THERMAL IMAGER

THERMAL IMAGER

Figure 1-9. Connecting Using the USB Cable

1-13

dag009f.eps

Loading…

Измерительные приборы Fluke TI20 — инструкция пользователя по применению, эксплуатации и установке на русском языке. Мы надеемся, она поможет вам решить возникшие у вас вопросы при эксплуатации техники.

Вы можете скачать инструкцию к Fluke TI20 по ссылке ниже, если не хотите ждать загрузки. Если остались вопросы, задайте их в комментариях после инструкции.

«Загружаем инструкцию», означает, что нужно подождать пока файл загрузится и можно будет его читать онлайн. Некоторые инструкции очень большие и время их появления зависит от вашей скорости интернета.

Остались вопросы?

Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)

Часто задаваемые вопросы

Как посмотреть инструкцию к Fluke TI20?

Необходимо подождать полной загрузки инструкции в сером окне на данной странице или скачать кликнув по специальной кнопке.

Руководство на русском языке?

Все наши руководства представлены на русском языке или схематично, поэтому вы без труда сможете разобраться с вашей моделью

Как можно распечатать инструкцию?

Скачайте ее по специальной кнопке над формой чтения на ваше устройства и отправьте на печать.

Понравилась статья? Поделить с друзьями:
  • Лего майнкрафт дом свинья инструкция по сборке
  • Tp link tl mr6400 инструкция на русском
  • Блок управления sk 13a stavrolit инструкция как настроить
  • Внешний фильтр тетра ех 600 инструкция
  • Руководство по хранению вис рхбз в воинских частях