Remove and replace batteries if monitor is not used for more than six months. PRECAUTIONS The UA-774 is designed to be used at home, by those who are eighteen (18) years and older, to monitor blood pressure (systolic and diastolic) and pulse rate. It is not designed for ambulatory use.
-
Page 3
Congratulations on purchasing a state-of-the-art LifeSource blood pressure monitor—one of the most technologically advanced monitors available today. Designed for ease of use and accuracy, this monitor will facilitate your daily blood pressure regimen. Physicians agree that daily self-monitoring of blood… -
Page 4: Table Of Contents
MONITOR COMPONENTS ……E-3 HOW UA-774 WORKS ……E-4 BEFORE YOU START .
-
Page 5: What Display Symbols Mean
WHAT DISPLAY SYMBOLS MEAN Display Condition/Cause Symbol The indicator while measurement is in progress. It blinks while detecting the pulse. An irregular heartbeat or body movement may have occurred. Refer to page E-10 for more information on irregular heartbeats. Previous measurement stored in MEMORY.
-
Page 6: Monitor Components
MONITOR COMPONENTS AC ADAPTER JACK PULSE DISPLAY SYSTOLIC DISPLAY DIASTOLIC DISPLAY START BUTTONS AIR CONNECTOR AIR SOCKET CUFF TUBE BATTERY COMPARTMENT In Canada (Toll-Free): 1-800-463-5414…
-
Page 7: How Ua-774 Works
HOW UA-774 WORKS LifeSource™ Blood Pressure Monitors are easy to use, accurate and digitally display full measurement readouts. Our technology is based on the “oscillometric method” — a noninvasive blood pressure determination. The term “oscillation” refers to any measure of vibrations caused by the arterial pulse. Our monitor examines the pulsatile pressure generated by the arterial wall as it expands and contracts against the cuff with each heartbeat.
-
Page 8: Selecting The Correct Cuff Size
SELECTING THE CORRECT CUFF SIZE Using the correct cuff size is important for an accurate reading. A cuff that is too large will produce a reading that is lower than the correct blood pressure; a cuff that is too small will produce a reading that is higher than the correct blood pressure.
-
Page 9: Taking Your Blood Pressure
TAKING YOUR BLOOD PRESSURE The UA-774 has several modes available to fit your blood pressure monitoring needs. Normal Measurement with Readings Stored in Memory Press the START 1 or START 2 button. Your blood pressure is measured and the reading is stored into memory. Each START button can store up to 30 readings in memory.
-
Page 10
TAKING YOUR BLOOD PRESSURE Now you are ready. Follow these simple steps: Sit comfortably with your left arm resting on a flat surface so that the center of your upper arm is at the same height as your heart. Lay left arm on the table, palm up and thread cuff end through metal loop, smooth side against arm. -
Page 11
TAKING YOUR BLOOD PRESSURE NOTE: If you wish to stop inflation at any time, press either START button again. NOTE: The maximum cuff pressure is set at 280 mmHg. If it reaches 280 mmHg, the auto exhaust will be triggered and cuff pressure will deflate to 0. -
Page 12: About Average Reading
MEASUREMENTS STORED IN MEMORY ABOUT MEMORY The memory function on the UA-774 blood pressure monitor is designed for two people. For each START button, the monitor can store up to 30 readings in memory. To keep track of previous measurements accurately, we recommend that you use the same START button each time you take a blood pressure reading.
-
Page 13: What Is An Irregular Heartbeat
WHAT IS AN IRREGULAR HEARTBEAT The UA-774 Blood Pressure Monitor provides a blood pressure and pulse rate measurement even when an irregular heartbeat occurs. An irregular heartbeat is defined as a heartbeat that varies by 25% from the average of all heartbeat intervals during the blood pressure measurement.
-
Page 14: Using The Monitor With Ac Adapter
USING THE MONITOR WITH AC ADAPTER The UA-774 has an AC adapter jack to allow you to supply power from an outlet in your home. We recommend you use only the exclusive AC adapter (Model TB:181) to avoid potential damage to the monitor.
-
Page 15: About Blood Pressure
ABOUT BLOOD PRESSURE ❤ What Is Blood Pressure? Blood pressure is the force exerted by blood against the walls of the arteries. Systolic pressure occurs when the heart contracts; diastolic pressure occurs when the heart expands. Blood pressure is measured in millimeters of mercury (mmHg).
-
Page 16: What Is Hypertension
Assessing High Blood Pressure The following standards for assessing high blood pressure (without regard to age) have been established as a guideline. BP Classification Normal Prehypertension Stage 1 Hypertension Stage 2 Hypertension SOURCE: The Seventh Report of the Joint National Committee on Prevention, Evaluation and Treatment of High Blood Pressure.
-
Page 17: Blood Pressure Record
ABOUT BLOOD PRESSURE ❤ Why Measure Blood Pressure at Home? It is now well known that, for many individuals, blood pressure readings taken in a doctor’ s office or hospital setting might be elevated as a result of apprehension and anxiety. This response is commonly called “white coat hypertension.”…
-
Page 18
In Canada (Toll-Free): 1-800-463-5414 ❤ E-15… -
Page 19: Troubleshooting
✓ TROUBLESHOOTING Problem Nothing appears in the display, even when the power is turned on. The cuff does not inflate. The unit does not measure. Readings are too high or too low. Other NOTE: If the actions described above do not solve the problem, contact A&D Medical or Auto Control Medical at the numbers listed at the bottom of these pages.
-
Page 20: Specifications
Model ….UA-774 Type …..Oscillometric Display .
-
Page 21: Contact Information
This LifeSource blood pressure product is covered by a Lifetime Warranty. See warranty card for details. Visit our web site at www.LifeSourceOnline.com For more information regarding use, care or servicing of your blood pressure monitor, contact: A&D Medical A division of A&D Engineering, Inc. 1555 McCandless Drive…
-
Page 22
CONTACT INFORMATION IMPORTANT! If You Need Assistance with the Set-Up or Operation We Can Help! Please call us FIRST before contacting your retailer at LifeSource Health Line 1-888-726-9966 — Toll Free 1-800-463-5414 — In Canada A specially trained representative will assist you A division of A&D Engineering, Inc.
Скачать файл PDF «A&D UA-774 Инструкция по эксплуатации» (394 Kb)
Популярность:
12931 просмотры
Подсчет страниц:
22 страницы
Тип файла:
Размер файла:
394 Kb
Trilingual Instruction Guide – UA-774
Dual Memory Auto-Inflate
Blood Pressure Monitor
Please read this important information before using your monitor.
☞ Please remember that only a medical practitioner is qualified
to interpret your blood pressure measurements. Use of this
device should not replace regular medical examinations.
☞ Have your physician review your procedure for using this
device. He or she will want to verify blood pressure
measurements before prescribing or adjusting medications.
☞ Consult your physician if you have any doubt about your
readings. Should a mechanical problem occur, contact
A&D Medical.
☞ Do not attempt to service, calibrate, or repair this device.
☞ Because your UA-774 monitor contains delicate, high-
precision parts, avoid exposing it to extremes in temperature
or humidity or to direct sunlight, shock and dust. A&D
Medical guarantees the accuracy of this device only when it is
stored and used within the temperature and humidity ranges
noted on page E-17.
☞ Clean the monitor and cuff with a dry, soft cloth or a cloth
dampened with water and a mild detergent. Never use alcohol,
benzene, thinner or other harsh chemicals to clean monitor or
cuff.
☞ Remove and replace batteries if monitor is not used for more
than six months
.
PRECAUTIONS
The UA-774 is designed to be used at home, by those who
are eighteen (18) years and older, to monitor blood pressure
(systolic and diastolic) and pulse rate. It is not designed for
ambulatory use.
IMPORTANT INFORMATION
✓
-
A&D UA-774 — page 1
Instruction Guide – UA-774 Dual Memor y Auto-Inflate Blood Pressur e Monitor …
-
A&D UA-774 — page 2
Please r ead this important information befor e using your monitor . ☞ Please r emember that only a medical practitioner is qualified to interpr et your blood pr essure measur ements. Use of this device should not r eplace r egular medical examinations. ☞ Have your physician r eview your pr ocedure for using this device. He or she will want to …
-
A&D UA-774 — page 3
TM Congratulations on pur chasing a state-of-the-art LifeSour ce blood pr essur e monitor—one of the most technologically advanced monitors available today . Designed for ease of use and accuracy , this monitor will facilitate your daily blood pr essur e r egimen. Physicians agr ee that daily self-monitoring of blood pr essur e is an important st …
-
A&D UA-774 — page 4
WHA T DISPLA Y SYMBOLS MEAN . . . . . . . . . . . . . . . . . . . E-2 MONITOR COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . E-3 HOW UA-774 WORKS . . . . . . . . . . . . . . . . . . . . . . . . . . E-4 BEFORE YOU ST ART . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-4 SELECTING THE CORRECT CUFF SIZE . . . . . . . . . . . . . …
-
A&D UA-774 — page 5
LifeSource Health Line (T oll-Free): 1-888-726-9966 Display Symbol Recommended Action Measur ement is in progr ess, r emain as still as possible. T ake measurement again and consult with your physician. Replace all batteries with new ones when the indicator blinks. T ry the measurement again. Remain very still during the measur ement. Fasten the cu …
-
A&D UA-774 — page 6
E-3 MONITOR COMPONENTS ? ? In Canada (T oll-Free): 1-800-463-5414 ST ART BUTTONS TUBE AC ADAPTER JACK SYSTOLIC DISPLA Y AIR CONNECTOR AIR SOCKET CUFF BA TTERY COMP ARTMENT DIASTOLIC DISPLA Y PULSE DISPLA Y …
-
A&D UA-774 — page 7
LifeSource Health Line (T oll-Free): 1-888-726-9966 Y ou must install 4 type AA (1.5 volt) batteries, or use the AC Adapter (see page E-11 for using the Monitor with AC Adapter) and attach the cuff to the monitor befor e using it. T o install batteries (or r eplace them if the “Low Battery” symbol appears on display), pr oceed as follows: 1. Re …
-
A&D UA-774 — page 8
In Canada (T oll-Free): 1-800-463-5414 E- 5 USE SMALL CUFF USE LARGE CUFF PROPER FIT RANGE INDEX Using the corr ect cuff size is impor tant for an accurate reading. A cuff that is too lar ge will produce a r eading that is lower than the corr ect blood pr essure; a cuf f that is too small will pr oduce a r eading that is higher than the corr ect bl …
-
A&D UA-774 — page 9
LifeSource Health Line (T oll-Free): 1-888-726-9966 T AKING YOUR BLOOD PRESSURE The UA-774 has several modes available to fit your blood pr essur e monitoring needs. Nor mal Measurement with Readings Stor ed in Memory Pr ess the ST AR T 1 or ST AR T 2 button. Y our blood pressur e is measur ed and the r eading is stored into memory . Each ST AR T b …
-
A&D UA-774 — page 10
E- 7 Now you ar e r eady . Follow these simple steps: 1. Sit comfortably with your left arm r esting on a flat surface so that the center of your upper arm is at the same height as your heart. 2. Lay left arm on the table, palm up and thr ead cuff end thr ough metal loop, smooth side against arm. Then position the tube off-center towar d the inner …
-
A&D UA-774 — page 11
LifeSource Health Line (T oll-Free): 1-888-726-9966 E-8 T AKING YOUR BLOOD PRESSURE NOTE: If you wish to stop inflation at any time, press either ST ART button again. NOTE: The maximum cuff pressure is set at 280 mmHg. If it reaches 280 mmHg, the auto exhaust will be triggered and cuff pressure will deflate to 0. 6. When the inflation is complete, …
-
A&D UA-774 — page 12
E-9 The memory function on the UA-774 blood pr essur e monitor is designed for two people. For each ST AR T button, the monitor can stor e up to 30 r eadings in memory . T o keep track of previous measur ements accurately , we recommend that you use the same ST AR T button each time you take a blood pressur e r eading. T o recall pr evious measur e …
-
A&D UA-774 — page 13
LifeSource Health Line (T oll-Free): 1-888-726-9966 E- 1 0 The UA-774 Blood Pr essur e Monitor provides a blood pr essure and pulse rate measur ement even when an irr egular heartbeat occurs. An irr egular heartbeat is defined as a hear tbeat that varies by 25% fr om the average of all heartbeat intervals during the blood pr essur e measurement. It …
-
A&D UA-774 — page 14
USING THE MONITOR WITH AC ADAPTER The UA-774 has an AC adapter jack to allow you to supply power fr om an outlet in your home. W e recommend you use only the exclusive AC adapter (Model TB:181) to avoid potential damage to the monitor . Connecting the AC adapter to the monitor: 1. Connect the AC adapter plug into the jack on the back of the monitor …
-
A&D UA-774 — page 15
LifeSource Health Line (T oll-Free): 1-888-726-9966 LifeSource Health Line (T oll-Free): 1-888-726-9966 ABOUT BLOOD PRESSURE ❤ E- 1 2 ❤ What Is Blood Pressure? Blood pr essur e is the for ce exerted by blood against the walls of the arteries. Systolic pr essure occurs when the hear t contracts; diastolic pr essur e occurs when the heart expands …
-
A&D UA-774 — page 16
E- 1 3 ❤ ABOUT BLOOD PRESSURE ❤ In Canada (T oll-Free): 1-800-463-5414 Assessing High Blood Pressure The following standar ds for assessing high blood pr essur e (without r egar d to age) have been established as a guideline. BP Classification Systolic (mmHg) Diastolic (mmHg) Normal <120 and <80 Pr ehypertension 120-139 or 80-89 Stage 1 H …
-
A&D UA-774 — page 17
LifeSource Health Line (T oll-Free): 1-888-726-9966 LifeSource Health Line (T oll-Free): 1-888-726-9966 E- 1 4 ❤ ABOUT BLOOD PRESSURE ❤ Why Measure Blood Pressure at Home? It is now well known that, for many individuals, blood pr essur e r eadings taken in a doctor’ s office or hospital setting might be elevated as a r esult of appr ehension …
-
A&D UA-774 — page 18
E- 1 5 ❤ TM In Canada (T oll-Free): 1-800-463-5414 …
-
A&D UA-774 — page 19
LifeSource Health Line (T oll-Free): 1-888-726-9966 TROUBLESHOOTING ✓ Problem Nothing appears in the display , even when the power is turned on. The cuff does not inflate. The unit does not measur e. Readings ar e too high or too low . Other Probable cause Batteries ar e drained. Battery terminals ar e not in the corr ect position. Battery voltag …
-
A&D UA-774 — page 20
E- 1 7 Model . . . . . . . . . . . . . . . . . . .UA-774 T ype . . . . . . . . . . . . . . . . . . . . .Oscillometric Display . . . . . . . . . . . . . . . . . .Digital character height . . . . . . . . . . . . . . . . . . . . . . .Pr essur e (16.0 mm)/ pulse (10.0 mm) . . . . . . . . . . . . . . . . . . . . . . .displayed simultaneously Memor y . . …
-
A&D UA-774 — page 21
CONT ACT INFORMA TION E- 1 8 Our pr oducts ar e designed and manufactured using the latest scientific and technological methods, and offer accurate, easy to use, home monitoring and tr eatment options. Our full pr oduct line includes: Aner oid Blood Pressure Kits Blood Pressure Cuffs Digital Blood Pressure Monitors Digital Thermometers Hear t Rate …
-
A&D UA-774 — page 22
CONT ACT INFORMA TION A division of A&D Engineering, Inc. 1555 McCandless Drive Milpitas, CA 95035 www .LifeSourceOnline.com LifeSour ce is a trademark of A&D Medical. ©2003 A&D Medical. All rights reserved. Specifications subject to change without notice. I-MAN:774 Printed in China 11/03 IMPORT ANT! If Y ou Need Assistance with the Se …
Информация о лекарственных препаратах, размещенная на AptekaMos.ru, не должна использоваться неспециалистами для самостоятельного принятия решения об их покупке и применении без консультации врача.
Свидетельство о регистрации средства массовой информации ЭЛ № ФС77-44705 выдано Федеральной службой по надзору в сфере связи, информационных технологий и массовых коммуникаций (Роскомнадзор) 21 апреля 2011 года.
Скачать
Instruction Guide – UA-774
Dual Memory Auto-Inflate
Blood Pressure Monitor