Vision™ OPLC™
The Unitronics V350-35-TR34 offers the following onboard I/Os:
22 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder Inputs
8 Relay Outputs, 4 high-speed npn Transistor Outputs
General Description
V350 OPLCs are micro-OPLCs, rugged programmable logic controllers that comprise:
On-board I/O configuration
Built-in operating panel containing a 3.5″ Color Touchscreen and programmable function keys
Communications
I/O Options
Information Mode
Programming
Software,
& Utilities
Unitronics
1 built-in serial port: RS232/RS485
Optional: the user may order and install
one or both of the following modules:
— RS232/RS485/Ethernet
— CANbus
Communication Function Blocks
include: SMS, GPRS, MODBUS
serial/IP. Protocol FB enables PLC to
communicate with almost any external
device, via serial or Ethernet
communications
V350 supports digital, high-speed, analog,
weight and temperature measurement I/Os via:
On-board I/O configuration
Model-dependent
I/O Expansion Modules
Local or remote I/Os may be added via
expansion port or CANbus.
This mode enables you to:
View & Edit operand values, COM port settings, RTC and screen
contrast/brightness settings
Calibrate the touchscreen
Stop, initialize, and reset the PLC
To enter Information Mode, press the <i> button for several seconds.
The Unitronics Setup CD contains VisiLogic software and other utilities
VisiLogic
Easily configure hardware and write both HMI and Ladder control
applications; the Function Block library simplifies complex tasks
such as PID. Write your application, and then download it to the
controller via the programming cable included in the kit.
Utilities
Includes UniOPC server, Remote Access for remote programming
and diagnostics, and DataXport for run-time data logging.
To learn how to use and program the controller, as well as use utilities such
as Remote Access, refer to the VisiLogic Help system.
V350-35-TR34
Installation Guide
1
Unitronics V350-35-RA22: List of Available Documents
Note for Owners:
Guidesimo.com webproject is not a service center of Unitronics trademark and does not carries out works for diagnosis and repair of faulty Unitronics V350-35-RA22 equipment. For quality services, please contact an official service center of Unitronics company. On our website you can read and download documentation for your Unitronics V350-35-RA22 device for free and familiarize yourself with the technical specifications of device.
More Network Router Devices:
-
SECO-LARM Mini Timer Module SA-026
The ENFORCER SA-026 is a low-voltage miniature delay timer module which operates on 12 to 24 volts AC or DC. This timer module will extend the activation time of a momentary contact switch for 1~60 seconds via a field-adjustable rotary pot. It is ideal for electrical locks which do not have a built-in time delay function. Its compact size makes it small enough to fit in a single-gang box or ins …
Mini Timer Module SA-026 Network Router, 1
-
Cisco Nexus 9000 Series
Cisco Nexus 9000 Series NX-OS Quality of Service Configuration Guide,Release 7.xFirst Published: 2015-01-31Last Modified: 2020-08-31Americas HeadquartersCisco Systems, Inc.170 West Tasman DriveSan Jose, CA 95134-1706USAhttp://www.cisco.comTel: 408 526-4000800 553-NETS (6387)Fax: 408 527-0883 …
Nexus 9000 Series Switch, 216
-
ORiNG IES-3242GC
Open-VisionOpen-VisionBack ViewFeaturesProduct InterfaceInstallationRack-mounted Install StepAC 100-240V PowerPower SwitchAC100-240V50-60HZONOFFWorld’s fastest Redundant Ethernet Ring: O-Ring(Recovery time < 10ms over 250 units connection)Managed Layer 2+ Switch with 24 10/100Mbps Ports and 2 ComboGigabit Copper/SFP PortsSupport ACLs, 802.1x User Authentication for SecurityManagement through …
IES-3242GC Network Router, 2
-
Maipu SM3300-28FX
Installation Manual SM3300-28FX Installation Manual Maipu Communication Technology Co., Ltd No. 16, Jiuxing Avenue Hi-tech Park Chengdu, Sichuan Province People’s Republic of China — 610041 Tel: (86) 28-85148850, 85148041 Fax: (86) 28-85148948, 85148139 URL: http:// www.maipu.com Email: [email protected] …
SM3300-28FX Network Router, 22
Recommended Documentation:
Vision™ OPLC™
i4 Automation Ltd — 01480 395256
Analog input wiring, current (2/3 wire)
Shields should be connected at the signal’s source.
The 0V signal of the analog input and output must be connected to the controller’s 0V.
Thermocouple
Thermocouple 0: use Input 9 as
negative input and 10 as positive.
Thermocouple 1: use Input 7 as
negative input and 8 as positive.
RTD
Unitronics
Analog Input Wiring
Analog input wiring, current/voltage (4-wire)
Type Temp. Range
mV
-5 to 56mV
200 to 1820PC
B
(300 to 3276PF)
-200 to 750PC
E
(-328 to 1382PF)
-200 to 760PC
J
(-328 to 1400PF)
-200 to 1250PC
K
(-328 to 2282PF)
-200 to 1300PC
N
(-328 to 2372PF)
0 to 1768PC
R
(32 to 3214PF)
0 to 1768PC
S
(32 to 3214PF)
-200 to 400PC
T
(-328 to 752PF)
PT100 (Sensor 0): use Input 9 and 10, related
to CM signal.
PT100 (Sensor 1): use Input 7 and 8, related to
CM signal.
4 wire PT100 can be used by leaving one of
the sensor leads unconnected.
Wire Color
ANSI (USA) BS1843 (UK)
+Grey
+None
-Red
-Blue
+Violet
+Brown
-Red
-Blue
+White
+Yellow
-Red
-Blue
+Yellow
+Brown
-Red
-Blue
+Orange
+Orange
-Red
-Blue
+Black
+White
-Red
-Blue
+Black
+White
-Red
-Blue
+Blue
+White
-Red
-Blue
7
Table of Contents for Unitronics V350-35-RA22:
-
V350-35-RA22 Installation Guide 2 Unitronics Removable Memory Storage Micro SD card: store datalogs, Alarms, Trends, Data Tables; export to Excel; backup Ladder, HMI & OS and use this data to ‘clone’ PLCs. For more data, refer to the SD topics in the VisiLogic Help system. Data Tables Data tables enable you to set recipe parameters and create datalogs. Additional product documentation is in the Technical Library, located at www.unitronics.com , and on the Unitronics’ Setup CD. Technical support is av
-
V350-35-RA22 Installation Guide 6 Unitronics I/O Wiring I/O Configuration ] npn Input Wiring Input wiring npn (sink) HSC input wiring, npn (sink) pnp Input Wiring Input wiring pnp (source) HSC input wiring, pnp (source) Shaft-encoder i4 Automation Ltd — 01480 395256
-
Unitronics 1 Vision™ OPLC™ V350-35-RA22 Installation Guide The Unitronics V350-35-RA22 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include 2 Analog, 2 PT100/TC, and 1 HSC/Shaft-encoder Input 8 Relay Outputs, 2 Analog Outputs General Description V350 OPLCs are micro-OPLCs, rugged programmable logic controllers that comprise: On-board I/O configuration Built-in operating panel containing a 3.5” Color Touchscreen and programmable function keys Communications 1 buil
-
Vision™ OPLC™ Unitronics 3 Mounting Dimensions Panel Mounting Before you begin, note that the mounting panel cannot be more than 5 mm thick. 1. Make a panel cut-out measuring 92×92 mm (3.622”x3.622”). 2. Slide the controller into the cut-out, ensuring that the rubber seal is in place. 3. Push the 2 mounting brackets into their slots on the sides of the controller as shown in the figure to the right. 4. Tighten the bracket screws against the panel. Hold the bracket securely against the unit while tightening the screw. 5. When properly mounte
-
Vision™ OPLC™ Unitronics 7 Analog Input Wiring Analog input wiring, current (2/3 wire) Analog input wiring, current/voltage (4-wire) Shields should be connected at the signal’s source. The 0V signal of the analog input and output must be connected to the controller’s 0V. Thermocouple Thermocouple 0: use Input 9 as negative input and 10 as positive. Thermocouple 1: use Input 7 as negative input and 8 as positive. RTD Type
-
Vision™ OPLC™ Unitronics 5 I/Os This model comprises a total of 12 inputs and 8 relays, 2 analog outputs. Input functionality can be adapted as follows: 1. All 12 inputs may be used as digital inputs. They may be wired in a group via a single jumper as either npn or pnp. In addition, according to jumper settings and appropriate wiring: — Inputs 5 a
-
V350-35-RA22 Installation Guide 8 Unitronics Analog Outputs Relay Outputs The 0V signal of the analog input and output must be connected to the controller’s 0V. Increasing Contact Life Span To increase the life span of the relay output contacts and protect the device from potential damage by reverse EMF, connect: A clamping diode in parallel with each inductive DC load An RC snubber circuit in parallel with each inductive AC
-
Vision™ OPLC™ Unitronics 9 Communication Port Turn off power before making communications connections. Caution Signals are related to the controller’s 0V; the same 0V is used by the power supply. Always use the appropriate port adapters. The serial port is not isolated. If the controller is used with a non-isolated external device, avoid potential voltage that exceeds ± 10V. Port 1 is type RJ-11 and may be set to either RS232 or RS485 via jum
-
V350-35-RA22 Installation Guide 10 Unitronics Opening the Controller Before performing these actions, touch a grounded object to discharge any electrostatic charge. Avoid touching the PCB board directly. Hold the PCB board by its connectors. 1. Turn off the power supply, disconnect, and dismount the controller. 2. The back cover of the controller comprises 4 screws, located in the corners. Remove the screws, and pull off the back cover. Changing I/O Settings 1. The I/O board of the controller is now exposed,
Questions, Opinions and Exploitation Impressions:
You can ask a question, express your opinion or share our experience of Unitronics V350-35-RA22 device using right now.